Search NASA⌕ Search

SEARCH · Search NASA

Results for “Incentive Programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

THE CO2 ABATEMENT POTENTIAL OF CALIFORNIA'S MID-SIZED COMMERCIAL BUILDINGS

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) todetermine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e. ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site?s annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB?s assumed utilization is far higher than is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed-in tariff proves ineffective at stimulating CHP deployment, while the SGIP buy down is more powerful. The attractiveness of CHP varies widely by climate zone and service territory, but in general, hotter inlandareas and San Diego are the more attractive regions because high cooling loads achieve higher equipment utilization. Additionally, large office buildings are surprisingly good hosts for CHP, so large office buildings in San Diego and hotter urban centers emerge as promising target hosts. Overall the effect on CO2 emissions is limited, never exceeding 27 percent of the CARB target. Nonetheless, results suggest that the CO2 emissions abatement potential of CHP in mid-sized CA buildings is significant, and much more promising than is typically assumed.

03 NATURAL GAS↗

The CO2 Reduction Potential of Combined Heat and Power in California's Commercial Buildings

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e., ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site's annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities plus a natural gas company, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB's assumed utilization is far higherthan is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed-in tariff proves ineffective at stimulating CHP deployment, while the SGIP buy down is more powerful. The attractiveness of CHP varies widely by climate zone and service territory, but in general, hotter inland areas and San Diego are the more attractive regions because high cooling loads achieve higher equipment utilization. Additionally, large office buildings are surprisingly good hosts for CHP, so large office buildings in San Diego and hotter urban centers emerge as promising target hosts. Overall the effect on CO2 emissions is limited, never exceeding 27percent of the CARB target. Nonetheless, results suggest that the CO2 emissions abatement potential of CHP in mid-sized CA buildings is significant, and much more promising than is typically assumed.

03 NATURAL GAS↗

Post-Retrofit Residential Assessments

This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be assessed but did not account for weather variation. From this statistical analysis, 18 study participants were selected and interviewed. The participants completed an in-home interview covering a range of topics, including changes in occupancy and additional changes to the homes that may have affected energy use. The goal of the interviews was to identify factors that may have contributed to unusual energy performance. These factors were identified by their frequency of occurrence in outperforming or underperforming homes, or simply by identifying factors that had the largest impact on overall savings. The motivations and levels of satisfaction with the outcomes of the upgrades were covered in detail, as well as extensive discussions of behaviors pertaining to thermal control, lighting, water, and appliance use. Most of cases studied achieved substantial energy savings, although it was more common for the projected savings to be greater than the demonstrated savings. Two factors that played a very large role in savings variation were 1) changes in occupancy and 2) fenestration improvements outside of the incentive programs. Motivation for pursuing the upgrades (e.g., environmental sustainability vs. comfort or cost savings) did not seem to play any role in achieving savings. Participants generally were more concerned with maintaining aesthetics through lighting than comfort through heating or cooling. They also seemed more likely to turn the lights off when leaving a room than to turn the heat off when leaving the home.

high performance homes↗

Mobilizing mine lands for biobased decarbonization strategies

Over 163 000 ha of mine lands in Pennsylvania (PA) have the potential to produce willow as a feedstock for renewable energy generation. Each year these lands could produce between 454 000 and 907 000 dry Mg of willow, which can be a feedstock for bioenergy (i.e., biopower) with carbon capture and sequestration (BECCS) or sustainable aviation fuel (SAF) production. We used a spatially explicit model to explore cost-minimized allocation of willow biomass from abandoned mine lands (AML) to be used for BECCS or SAF production and to abate carbon dioxide. The results suggest that between 454 000 and 907 000 dry Mg of biomass can be produced on AML in PA at costs from $94 to $250 per dry Mg. This AML willow biomass could be combined with other available biomass and aggregated to ten facilities to produce 17.9 TWh of power; alternatively, it could produce 958 million liters of jet fuel, 638 million liters of renewable diesel, and 1.289 billion liters of naphtha, along with 0.735 TWh of electricity. From this analysis, in PA, under the BECCS pathway, up to 36 million Mg per year of CO2 could be abated at costs of up to $134 per Mg; under the SAF pathway, up to 17.5 million Mg per year of CO2 could be abated at costs up to $150 per Mg of CO2. The use of mine land willow as a supplemental feedstock for SAF and BECCS would need strong incentive programs if costs of production are to be comparable with production on agricultural land.

Wahlstrom, Mallory [Pennsylvania State University]↗

Advances in shrub-willow crops for bioenergy, renewable products, and environmental benefits

Short-rotation coppice systems like shrub willow are projected to be an important source of biomass in the United States for the production of bioenergy, biofuels, and renewable bio-based products, with the potential for auxiliary environmental benefits and multifunctional systems. Almost three decades of research has focused on the development of shrub willow crops for biomass and ecosystem services. The current expansion of willow in New York State (about 500 ha) for the production of renewable power and heat has been possible because of incentive programs offered by the federal government, commitments by end users, the development of reliable harvesting systems, and extension services offered to growers. Improvements in the economics of the system are expected as willow production expands further, which should help lower establishment costs, enhance crop management options and increase efficiencies in harvesting and logistics. As a result, deploying willow in multifunctional value-added systems provides opportunities for both potential producers and end users to learn about the system and the quality of the biomass feedstock, which in turn will help overcome barriers to expansion.

09 BIOMASS FUELS↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experience curve development and cost reduction disaggregation for fuel cell markets in Japan and the US

Technology learning rates can be dynamic quantities as a technology moves from early development to piloting and from low volume manufacturing to high volume manufacturing. This work describes a generalizable technology analysis approach for disaggregating observed technology cost reductions and presents results of this approach for one specific case study (micro-combined heat and power fuel cell systems in Japan). We build upon earlier reports that combine discussion of fuel cell experience curves and qualitative discussion of cost components by providing greater detail on the contributing mechanisms to observed cost reductions, which were not quantified in earlier reports. Greater standardization is added to the analysis approach, which can be applied to other technologies. This paper thus provides a key linkage that has been missing from earlier literature on energy-related technologies by integrating the output of earlier manufacturing cost studies with observed learning rates to quantitatively estimate the different components of cost reduction including economies of scale and cost reductions due to product performance and product design improvements. This work also provides updated fuel cell technology price versus volume trends from the California Self-Generation Incentive Program, including extensive data for solid-oxide fuel cells (SOFC) reported here for the first time. The Japanese micro-CHP market is found to have a learning rate of 18% from 2005 to 2015, while larger SOFC fuel cell systems (200 kW and above) in the California market are found to have a flat (near-zero) learning rate, and these are attributed to a combination of exogenous, market, and policy factors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advancing Ethanol-to-Jet cost Effectiveness via direct conversion to n -Butene-Rich olefins and Co-Product Valorization

Ethanol is a promising feedstock for sustainable aviation fuel production; however, conventional routes face significant energy and cost challenges, particularly due to the ethanol dehydration step to ethylene. Here, this study leverages breakthrough experimental data to perform comprehensive techno-economic and life-cycle assessments of an innovative ethanol-to-jet process. The process employs a single-step catalytic conversion, enabled by multifunctional Cu-ZrO 2 /SBA-16 catalyst, to directly upgrade ethanol into a mixed olefin stream rich in n-butene. The single-step conversion eliminates the costly ethanol dehydration step in the conventional process. High selectivity toward n-butene offers key advantages: it simplifies downstream oligomerization into jet-range hydrocarbons and enables the co-production of renewable n-butene alongside sustainable aviation fuel. The analysis estimates a minimum fuel selling price as low as $\$$2.50 per gallon, whether using corn ethanol or cellulosic ethanol from corn stover. Life cycle CO 2 equivalent emissions are projected to be as low as 10.6 g CO 2 eq/MJ sustainable aviation fuel, representing over 70% reduction compared to conventional petroleum-based jet fuel. This one-step ethanol upgrading approach not only facilitates SAF and n-butene co-production but also provides operational flexibility. The ability to tailor product outputs allows the ethanol-to-jet process to adapt to varying feedstocks, incentive programs, and market dynamics, ultimately enhancing the economic viability of sustainable aviation fuel production.

Xu, Yiling [Pacific Northwest National Laboratory ↗

Energy-efficient multimodal mobility networks in transportation digital twins: Strategies and optimization

The study proposes a comprehensive Transportation Mobility (TransitMo) framework covering conceptual design, model formulation, optimization, simulation, and impact analysis of the transportation mobility system. TransitMo is composed of a transportation digital twin developed in Simulation of Urban MObility (SUMO) and an Intelligent Traffic Management and Control Center (ITMCC) that identifies the best ways to improve the movement of people within urban areas using various modes of transportation. This study encompasses advanced modeling techniques, algorithms, and strategic testing to optimize energy efficiency and mobility in a multimodal shared mobility network. TransitMo’s practical applications are exemplified through a city-scaled simulation network in Chattanooga, TN, employing demographic data to analyze historical traffic patterns and forecast future demands. Central to this methodology are three models: the User Preference Model (UP), the Energy Consumption Model (EC), and the System Optimization Model (SO). These models work in concert to iteratively devise the optimal travel incentives and minimize the total system cost in a real-time manner. In conclusion, test results verified that the proposed adaptive incentive program and optimized bus scheduling can improve network performance by increasing public transit ridership.

42 ENGINEERING↗

How do the research and public communities view biofuel development?

Understanding how public and research view biofuel development, especially the unsynchronized views, can explain the gaps between the actual biofuel production and consumption and the government mandates in the US. Applying a comparative text mining technique, these views are explored using 9924 news articles and 57,849 research abstracts. It is found both the public and research communities respond actively to major policy and incentive programs and market conditions and the public has been closely following important research advances. However, research and practice should be coordinated to achieve economies of scale for regular and alternative biofuels. Priority is particularly needed for policy research to support legislation and enforcement and remove technical barriers to commercialization; meanwhile, greater attention is needed to prompt the commercialization of mature technologies. In addition, sentiment analysis shows positive public perceptions in general and negative perceptions primarily stemming from fraud in biofuel tax-credit programs with minor concerns on unintended negative impacts of biofuel development and policy implementation issues. This study contributes to methodology by using cutting-edge text-mining techniques to the largest and most up-to-date datasets of public news articles and research publication abstracts so as to compare public and academic views on biofuel development. As a result, this study also contributes to knowledge discovery by providing new perspectives on biofuel development, which will support policy design and identify future research directions.

09 BIOMASS FUELS↗

Aqueous Bromide Discharges from U.S. Coal-Fired Power Plants: Points of Origin, Concentration Ranges, and Effluent Treatment Costs

Bromide discharges from coal-fired power plants have received increased attention from regulatory bodies due to their contribution to the formation of disinfection byproducts (DBPs) in downstream drinking water treatment plants. Here, this paper characterizes the relative contributions of bromide from coal feedstocks and bromine-based mercury control processes, estimates the distribution of bromide concentrations at 85 active coal-fired power plants across the United States (U.S.) with wet flue gas desulfurization units, and estimates the cost of bromide removal from wastewater discharge using year 2020 data. Bromide discharges are estimated at the plant level using a combination of the reported coal rank and composition combusted, estimates of bromide addition in mercury control techniques under multiple halogen addition scenarios, and the estimated flue gas desulfurization (FGD) wastewater flow rate. The median, simulated plant-level estimation of total FGD wastewater flow is 18.3 gallons/min at a bromide concentration of 319 mg/L, equivalent to ~11.6 tonnes/year of bromide discharges to the environment. Next, we evaluated the expected cost of employing the best available technology (BAT) to control bromide discharges in FGD wastewater to prevent contributions to DBP formation. Treatment would need to remove more than 99.8% of bromide to reach the 0.2 mg/L voluntary incentive program (VIP) limit. The total cost of treatment depends on whether disposal is on- or off-site; the average costs for all plants combined come to an average of $110 million ($95.2/kgal) in 2021 U.S. dollars for on-site disposal, or $134 million ($115/kgal) for off-site disposal.

01 COAL, LIGNITE, AND PEAT↗

Evaluating opportunity for distributed wind energy in rural and agricultural areas

Wind energy is among the most mature renewable energy technologies, accounting for 11% of the current US electricity generation in 2024, with the lowest average levelized cost. While it is known that substantial opportunity exists for further development, a key question has been where wind energy is best suited compared to other technologies. This study leverages an immense dataset of parcel-resolved technoeconomic potential for the contiguous United States, focusing on distributed wind (DW) energy—a configuration where one or more turbines, typically 30–60 m in height are used to satisfy nearby energy needs. The analysis is conducted at multiple spatial scales and considers land use, crop land, census, and incentive program data to determine the most opportune areas for market development. The results show that rural, agricultural and residential areas are most suited to DW. Connection type (in front of, or behind the meter) and regulations determine the best application, while siting constraints, economics, demand and the wind resource determines the optimal size of turbine.

17 WIND ENERGY↗

Calculating Behind-the-Meter Energy Storage Incentives on an Avoided Cost Basis

Behind-the-meter (BTM) energy storage offers the potential for shared investment by utilities and their customers, in which both parties share in the costs and benefits of battery investment. Several utilities and a handful of states have begun providing incentives to help customers purchase BTM energy storage, and in exchange, operate that battery on behalf of the customer to realize grid benefits such as meeting peak capacity needs. But there is wide variation in the value and structure of these incentives, suggesting a lack of clarity on the value of BTM storage to the grid and to non-participating customers who fund the incentives for participating customers. This paper provides an objective framework for establishing BTM energy storage incentives based on the avoided cost of generation from a marginal, gas-fired peaking plant. It also conducts several sensitivity analyses to see how those avoided costs vary with emissions pricing, gas prices, plant heat rates, and utility capital structures. This work may be of use to utilities, regulators, and energy system stakeholders in providing a value-based framework for BTM incentive programs that can be used in the absence of policy guidance.

Twitchell, Jeremy B.↗

Review of Power System Support Functions for Inverter-Based Distributed Energy Resources - Standards, Control Algorithms, and Trends

Penetration of renewable energy in power systems has been increasing in the past decades in response to increased global electricity demand and concerns for the environment. Distributed energy resources (DERs) based on renewables have experienced rapid growth thanks to the incentive programs and broad-based participation. With the growing prevalence of DERs, the risk of grid instability and vulnerability increases due to the intermittent nature of renewable energy. At the same time, the voltage and frequency deviation problems emerge more often when the reverse power flow occurs under supply-demand imbalance in distributed power systems. Standards and grid codes have been issued for DER inverters to interconnect with the distribution grid. The updated standard and grid codes expect DERs to provide a variety of power system support functions in order to incorporate higher DER penetration and to maximize DER value to the grid. This paper provides an overview of the power system support functions from renewable DER inverters, which are categorized as: voltage regulation by active/reactive power control, frequency regulation by active power control, voltage ride-through, and frequency ride-through. The benefits and drawbacks of each algorithm are presented and compared with its predecessor, manifesting the logic in the evolution of the algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Solar Energy Aggregation Under Various Billing Mechanisms

Ongoing reductions in the cost of solar photovoltaic (PV) systems are driving increased installations by residential households. Various incentive programs such as feed-in tariff, net metering, net purchase, and sale that allow the prosumers to sell their generated electricity to the grid are also powering this trend. In this paper, we investigate sharing of PV systems among a community of households, who can also benefit further by pooling their production. Using cooperative game theory, we find conditions under which such sharing decreases their net total cost. We also develop allocation rules such that the joint net electricity consumption cost is allocated to the participants. These cost allocations are based on the cost causation principle. The allocations also satisfy the standalone cost principle and promote PV solar aggregation. Here, we also perform a comparative analytical study on the benefit of sharing under the mechanisms favorable for sharing, namely net metering, and net purchase and sale. The results are illustrated in a case study using real consumption data from a residential community in Austin, TX, USA.

14 SOLAR ENERGY↗

Bringing Automated Fault Detection and Diagnostics Tools for HVAC&R Into the Mainstream

Heating, ventilation, and air-conditioning (HVAC) systems consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. commercial buildings. Additionally, commercial refrigeration (R) systems add about 1 quad to commercial buildings energy consumption. Most HVAC systems operate with one or more faults that result in increased energy consumption. Fault detection and diagnostics (FDD) tools have been developed to address this national issue, and many tools are commercially available. FDD tools have the potential to save considerable energy for an existing commercial rooftop unit (RTU) and refrigeration systems. These devices can be used for both retro commissioning and, when faults are addressed, continuous commissioning. However, there appears to be multiple market barriers for this technology. Although there are efforts to develop FDD tool standards, currently there are no standards and methods to define functions, capabilities, accuracy, and reliability of FDD tools in the field. Moreover, most of the commercial FDD tools have not been verified in the field independently. This paper presents a comprehensive approach for bringing HVAC FDD tools into the mainstream. The approach involves demonstrating ten commercially available FDD tools installed at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying and assessing market barriers, creating a process evaluation methodology, and assisting utility companies in developing incentive programs. Furthermore, the preliminary baseline results from the case study demonstrate how the use of an independent monitoring system (IMS) can be used for ground-truth in evaluating FDD tools in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AN APPROACH TO BRINGING AUTOMATED FAULT DETECTION AND DIAGNOSIS (AFDD) TOOLS FOR HVAC&R INTO THE MAINSTREAM

Heating, ventilation and air-conditioning (HVAC) systems can consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. in commercial buildings. Additionally, commercial refrigeration (R) systems add about 2 quads to commercial buildings energy consumption. Most HVAC systems have one or more faults (low/high refrigerant charge, valve leakage, condenser/evaporator fouling, filter/dryer restriction, economizer faults, controls faults) that result in increased energy consumption. Automated fault detection and diagnosis (AFDD) tools have been developed to address this national issue and many tools are commercially available. AFDD tools have the potential to save considerable energy for existing commercial RTUs, chillers and refrigeration systems. These devices can be used for both retro commissioning, and, when faults are addressed, continuous commissioning as well. However, there appears to be multiple market barriers for this technology. A key market barrier for this technology is the lack of awareness of AFDD products among potential customers. Most HVAC contractors are not familiar with the latest AFDD technologies and HVAC technicians lack skills regarding these technologies. Quantifying potential benefits to building owners is difficult since there are several FDD tools with varying capabilities. For instance, there are several FDD products ranging from handling just economizer faults to those that also handle full-blown refrigerant-side and air-side faults. Methods/algorithms used in FDD vary significantly. Even though there are efforts to develop standards, currently there are no standards/methods to define functions, capabilities, accuracy, and reliability of FDD tools. Moreover, most of the commercial AFDD tools have not been verified in the field independently. This paper presents a comprehensive approach to bringing HVAC AFDD tools into the mainstream. The approach involves demonstrating ten commercially available tools at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying market barriers, and assisting utility companies in developing incentive programs. This paper presents selection of AFDD tools, ite identification, and field testing and evaluation method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Manufacturing Readiness and Cost Impacts for PEM Stack and Balance of Plant

The results of two Manufacturing Readiness Assessments of PEM fuel cell stacks and material handling equipment (MHE) and backup power (BUP) PEM fuel cell systems are given. Design modifications of fuel cell systems were made because the initial, 2008 designs did not fully meet the operational requirements of the markets. This situation indicates the 2008 risk elements were overstated.For 2010 BUP and MHE fuel cell systems, manufacturers had not reached the Low Rate Initial Production (LRIP) defined in the 2008 MRA Report at 1,000 units per year per manufacturer.For fuel cell stacks, LRIP was demonstrated by more than one manufacturer.The federal tax incentive program has compensated for the initial high cost of fuel cell systems.The Balance-of-Plant (BOP) has not evolved as rapidly as the PEM fuel cell stack manufacturing readiness.The BOP in 2014 is as costly as the fuel cell stack for MHE applications.

30 DIRECT ENERGY CONVERSION↗