At least 91 records · Page 5

Dynamic response of shock waves in transonic diffuser and supersonic inlet - An analysis with the Navier-Stokes equations and adaptive grid

An existing method which solves the multi-dimensional ensemble-averaged compressible time-dependent Navier-Stokes equations in conjunction with mixing length turbulence model and shock capturing technique has been extended to include the shock-tracking adaptive grid systems. The numerical scheme for solving the governing equations is based on a linearized block implicit approach. The effects of grid-motion and grid-distribution on the calculated flow solutions have been studied in relative detail and this is carried out in the context of physically steady, shocked flows computed with non-stationary grids. Subsequently, the unsteady dynamics of the flows occurring in a supercritically operated transonic diffuser and a mixed compression supersonic inlet have been investigated with the adaptive grid systems by solving the Navier-Stokes equations.

Liu, N.-S.↗

Performance and boundary-layer data from 12 degree and 23 degree conical diffusers of area ratio 2.0 at Mach numbers up to choking and Reynolds numbers up to 7.5 x 10(6)

For each of two inlet-boundary-layer thicknesses, performance and boundary-layer characteristics have been determined for a 12 degree, 10-inch-inlet-diameter diffuser, a 12 degree, 21-inch-inlet-diameter diffuser, and a 23 degree, 21-inch-inlet-diameter diffuser. The investigation covered an inlet Mach number range from about 0.10 to coking. The corresponding inlet Reynolds number, based on inlet diameter, varied from about 0.5 x 10(6) to 7.5 x 10(6).

Little, B H , Jr↗

Investigation at Mach Number 1.88 of Half of a Conical-spike Diffuser Mounted as a Side Inlet with Boundary-layer Control / H. Fred Goelzer and Edgar M. Cortright, Jr

Experimental investigation was conducted at Mach number 1.88 to determine performance characteristics of half a 50 degree-conical-spike inlet mounted on a flat plate. Initial boundary layer was removed up-stream of inlet by a ram-type scoop of variable height. Initial boundary-layer thickness was also varied. With complete removal of initial boundary layer, total-pressure recovery of approximately 70 percent. Several alternative boundary-layer-removal systems were investigated which decreased the adverse effect of operating the ram scoop sub-critically.

BOUNDARY LAYER CONTROL-INTERNAL AERODYNAMICS↗

Experimental investigation of water injection in subsonic diffuser of a conical inlet operation at free-stream Mach number of 2.5

A spike-type nose inlet with sharp-lip cowl was investigated at a free-stream Mach number of 2.5 with water injection in its 16-inch diameter, 11-foot-long subsonic diffuser section. Inlet total temperature of exit with liquid-air ratios of about 0.04 with no apparent change in the critical pressure recovery. The observed temperature drops were less than the theoretically predicted values, and the amount of water evaporated was 35 to 50 percent less than that theoretically possible.

Beke, Andrew↗

An analytical and experimental study of a short s-shaped subsonic diffuser of a supersonic inlet

A subscale HiMAT forebody and inlet was investigated over a range of Mach numbers to 1.4. The inlet exhibited a transitory separation within the diffuser but steady state data indicated reattachment at the diffuser exit. A finite difference procedure for turbulent compressible flow in axisymmetric ducts was used to successfully model the HiMAT duct flow. The analysis technique was further used to estimate the initiation of separation and delineate the steady and unsteady flow regimes in similar S-shaped ducts.

Neumann, H. E.↗

An analytical and experimental study of a short S-shaped subsonic diffuser of a supersonic inlet

An experimental investigation of a subscale HiMat forebody and inlet was conducted over a range of Mach numbers to 1.4. The inlet exhibited a transitory separation within the diffuser but steady state data indicated reattachment at the diffuser exit. A finite difference procedure for turbulent compressible flow in axisymmetric ducts was used to successfully model the HiMAT duct flow. The analysis technique was further used to estimate the initiation of separation and delineate the steady and unsteady flow regimes in similar S-shaped ducts.

Neumann, H. E.↗

Analytical and experimental studies of a short compact subsonic diffuser for a two-dimensional supersonic inlet

An experimental study of a two-dimensional supersonic inlet with a short compact subsonic diffuser, length to exit diameter (dl/d) ratio of 1.25, was conducted to investigate the impact of the short diffuser on inlet performance at low speeds and to assess the diffuser subsonic performance for a simulated diffuser flow corresponding to high-speed inlet conditions near the design flight Mach number of 2.2. For the low-speed testing, a drooped lip was employed to improve the inlet performance at a high angle of attack. For the simulated high-speed testing, air was blown through slots or discrete nozzles as an active boundary-layer control. The results from the low-speed performance test were compared with the results from a previous test program on the same inlet with a long subsonic diffuser (dl/d = 4.5). The comparison indicates that inlet recovery was not affected by the use of the short diffuser for either the baseline (no droop) or the drooped cowl lip configuration. However, the inlet baseline distortion for the short diffuser configuration was substantially higher than for the long diffuser. A comparison of the two configurations with a 70 deg drooped lip showed no significant difference in distortion. For the portion of the experimental program in which diffuser conditions for high-speed flight were simulated, diffuser-induced flow separation occurred. This separation was predicted from an analytical study that used the Hess potential flow panel method and the Herring two-dimensional boundary-layer analysis computer codes. The flow separated mainly on the diffuser ramp. Subsequent tests in which boundary-control systems were utilized showed that blowing with either slots or discrete nozzles could suppress the flow separation in the short subsonic diffuser, thereby substantially improving the diffuser performance.

Iek, Chanthy↗

Comparative study of subsynchronous rotating flow patterns in centrifugal compressors with vaneless diffusers

A comparative experimental investigation of the unstable operating modes of a centrifugal compressor was made. Impeller and/or diffuser rotating stall was observed, depending on the flow conditions. The measured relative rotational speed of this perturbation is cross checked with other experimental data and it is shown that the rotational speed is strongly dependent on the type of rotating stall. The diffuser absolute inlet flow angle at the onset of diffuser rotating stall agrees well with the value predicted by an existing stability criterion.

Frigne, P.↗

Performance of a short annular dump diffuser using suction-stabilized vortices at inlet Mach numbers to 0.41

A short, annular dump diffuser was designed to use suction to establish stabilized vortices on both walls for improved flow expansion in the region of an abrupt area change. The diffuser was tested at near ambient inlet pressure and temperature. The overall diffuser area ratio was 4.0. The inlet height was 2.54 cm and the exit pitot-static rakes were located at a distance from the vortex fence equal to two or six times the inlet height. Performance data were taken at near ambient temperature and pressure for nominal inlet Mach numbers of 0.18 to 0.41 with suction rates of 0 to 18 percent of the total inlet airflow. The exit velocity profile could be shifted toward either wall by adjusting the inner- or outer-wall suction rate. Symmetrical exit velocity profiles were unstable, with a tendency to shift back to hub- or tip-weighted profile. Diffuser effectiveness was increased from about 47 percent without suction to over 85 percent at a total suction rate of about 14 percent. The diffuser total pressure losses at inlet Mach numbers of 0.18 and 0.41 decreased from 1.1 and 5.6 percent without suction to 0.48 and 5.2 percent at total suction rates of 14.4 and 5.6 percent, respectively.

Smith, J. M.↗