Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverter Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Faster-Than-Real-Time Framework for Reliability-Oriented Simulation of PV Inverters

Physics-of-Failure (PoF) based reliability assessment for photovoltaic (PV) inverters requires long-duration electrical and electrothermal stress histories, yet generating such stress histories with high-fidelity switching models over year long mission profiles is computationally prohibitive. Conventional methods either sacrifice modeling fidelity for speed or require runtimes that are impractical for design iteration and uncertainty studies. To address this bottleneck, this paper presents a High-Performance Computing (HPC) based simulation frame work for faster-than-real-time reliability-oriented simulation. The proposed framework integrates the Average-to-Switching (A2S) method with parallel computing techniques to accelerate switching-level waveform reconstruction. We further introduce optimization strategies, including cluster merging and sensitivity based mission profile screening, to reduce the computational burden. Evaluated using real-world mission profile inputs and a MATLAB/Simulink switching-model reference, the framework reduces the simulation time for a one-year mission from an intractable multi-year duration to approximately 7.3 minutes while maintaining low waveform error. This acceleration provides a practical reliability-oriented simulation engine that can be coupled with component-specific aging models for subsequent PV inverter PoF assessment.

High-performance Computing↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to subhourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

accuracy↗

Towards a data-driven model of hadronization using normalizing flows

We introduce a model of hadronization based on invertible neural networks that faithfully reproduces a simplified version of the Lund string model for meson hadronization. Additionally, we introduce a new training method for normalizing flows, termed MAGIC, that improves the agreement between simulated and experimental distributions of high-level (macroscopic) observables by adjusting single-emission (microscopic) dynamics. Our results constitute an important step toward realizing a machine-learning based model of hadronization that utilizes experimental data during training. Finally, we demonstrate how a Bayesian extension to this normalizing-flow architecture can be used to provide analysis of statistical and modeling uncertainties on the generated observable distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep Learning-enhanced Block-Diagram Modeling of Solar Power Systems

Data-driven models of power system inverter-based resources are desired to run simulations faster than with detailed electromagnetic transient models, to hide proprietary design details, to support control system design applications, and to aggregate the effects of distributed energy resources. This paper applies a customized Hammerstein Wiener framework to train block diagram models from thousands of electromagnetic transient simulations or experimental test records. The block diagram models integrate with larger grid simulations as voltagecontrolled current sources or current-controlled voltage sources for several simulators. Guidelines for block architecture and training are presented. Three-phase balanced, three-phase unbalanced, and single-phase examples all achieve an acceptable root mean square error of no more than 0.05 per-unit.

Mcdermott, Thomas E. [Private consulting company]↗

On the Source of Conductivity in Alkaline Zn Anodes: Zn Percolation and ZnO Bridging

Alkaline Zn anodes are fundamental to commercial Zn-MnO 2 batteries as well as emerging rechargeable designs. In these electrodes, Zn particles are both the active material and source of electronic conduction. However, there are known cases in which electronic connectivity between Zn particles or the current collecting pin is lost even though the battery continues to function. Here we use X-ray computed tomography (CT) of AA batteries to demonstrate several examples of Zn particle-to-particle connectivity breakdown, which is observed even in cases at relatively high discharge rate. This indicates maintenance of the electronic network through the less-conductive ZnO discharge product. We introduce a new equation for electronic conductivity maintained through bridges of ZnO formed between percolating Zn particles. This necessitates discarding the Bruggeman correlation and instead redefining effective electronic conductivity using percolation theory. We demonstrate that such a model for conduction enables prediction of an inverted reaction zone, which is an experimentally observed case in which significant Zn dissolution and ZnO formation occurs heavily near the current collecting pin. Current computational Zn-MnO 2 models never predict an inverted reaction zone, and thus the updated conductivity enables models to accurately explain a wider range of experimental conditions.

Guida, Dominick P. [Northeastern Univ., Boston, MA↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to sub-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗

Visibility-enhanced model-free deep reinforcement learning algorithm for voltage control in realistic distribution systems using smart inverters

Increasing integration of distributed solar photovoltaic (PV) into distribution networks could result in adverse effects on grid operation. Traditional model-based control algorithms require accurate model information that is difficult to acquire and thus are challenging to implement in practice. Here, this paper proposes a surrogate model-enabled grid visibility scheme to empower deep reinforcement learning (DRL) approach for distribution network voltage regulation using PV inverters with minimal system knowledge. In contrast to existing DRL methods, this paper presents and corroborates the adverse impact of missing load information on DRL performance and, based on this finding, proposes a surrogate model methodology to impute load information utilizing observable data. Additionally, a multi-fidelity neural network is utilized to construct the DRL training environment, chosen for its efficient data utilization and enhanced robustness to data uncertainty. The feasibility and effectiveness of the proposed algorithm are assessed by considering DRL testing across varying degrees of observable load information and diverse training environments on a realistic power system.

14 SOLAR ENERGY↗

Side-by-Side Comparison of Subhourly Clipping Models: Preprint

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to inter-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of said approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating two different clipping correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons will be performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The models can improve accuracy up to 3% in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

clipping↗

Selecting Appropriate Model Complexity: An Example of Tracer Inversion for Thermal Prediction in Enhanced Geothermal Systems

Abstract A major challenge in the inversion of subsurface parameters is the ill‐posedness issue caused by the inherent subsurface complexities and the generally spatially sparse data. Appropriate simplifications of inversion models are thus necessary to make the inversion process tractable and meanwhile preserve the predictive ability of the inversion results. In this study, we investigate the effect of model complexity on fracture aperture inversion and thermal performance prediction in a field‐scale EGS model. Principal component analysis was used to map the aperture field to a low‐dimensional latent space. The complexity of the inversion model was quantitatively represented by the percentage of total variance in the original aperture fields preserved by the latent space. Tracer, pressure and flow rate data were used to invert for fracture aperture through an ensemble‐based inversion method, and the inferred aperture field was used to predict thermal performance. With an over‐simplified aperture model, ensemble collapse occurred. The inverted aperture models failed to resolve necessary flow and transport features, leading to a biased thermal performance prediction. A complex aperture model involved excessive features and was prone to overinterpreting the inversion data. Both the tracer/pressure/flow rate data reproduction and thermal prediction showed significant uncertainties, making it difficult to properly estimate long‐term thermal performance. Fortunately, our results indicate that there exists an appropriate model complexity which can simultaneously match inversion data and predict thermal performance with an acceptable uncertainty. The quality of the fit of tracer data appears to be a useful indicator of such an appropriate model complexity.

15 GEOTHERMAL ENERGY↗

Machine Learning-Driven Reliability Estimation of PV Inverters Considering Alert-Ambient Variability

Weather-induced spatio-temporal degradation limits outdoor PV inverter lifetime and reliability, necessitating advanced data analysis. This study employs a top-down, data-driven approach utilizing multiple machine learning (ML) algorithms to estimate inverter reliability in a 1.4 MW PV power plant, considering factors such as irradiance, humidity, temperature, time of day, and weather conditions. An extensive alert dataset from 17 identical inverters, including alert types, propagation, and frequency, reveals significant correlations with environmental factors and inverter output power, enabling the construction of a performance reliability model. Dual-stage supervised-ML models are evaluated for accuracy, with the ‘classification-regression’ model by an artificial neural network (ANN) tested on the averaged “Alert-Ambient” dataset, which is outperformed by ‘clustering-regression’ models using random forest (RF) and K-Nearest Neighbors (KNN) on individual inverter datasets. K-means clustering applies principal component analysis to reduce dimensions, achieving improved accuracy beyond the 80% achieved by ANN on the averaged dataset. Second-stage regression estimates inverter reliability with a mean square error of 0.0195 on the averaged dataset and as low as 0.002 on individual inverter datasets using RF. Furthermore, these findings highlight the method's suitability for estimating PV inverter output reliability under ambient conditions, essential for digital twin development and related applications.

14 SOLAR ENERGY↗

Large-Scale Inverter Integration in Bulk Power Grids Using Heterogeneous Grid-Forming Control Strategies

The conventional generation within the grid is gradually being replaced by inverter based resources. However, the integration of inverters into realistic transmission grid models has not been thoroughly explored. To address this gap, this work develops an automation framework aimed at facilitating the integration of a large number of inverter-based resources into a large-scale grid. Two types of grid-forming controlled inverters—namely droop-controlled inverters and virtual synchronous machine-controlled inverters—are developed for use in positive-sequence simulation packages. Various penetration levels ranging from 23% to 100% of grid-forming inverters are tested in a grid setup in the US Western Interconnection. The dynamic performance of inverters under different control schemes is compared in response to various disturbances.

Lyu, Xue [BATTELLE (PACIFIC NW LAB)]↗

IBR Bulk System Protection Issues and Modeling Challenges

Issue to be Address: Difficulty in predicting Inverter (IBR) generation dynamic response characteristics. Main challenges are unavailability of proprietary control details for modeling and the aggregate mixed IBRs with different dynamic response characteristics all contributing during system faults. Framework for Discussion: Identifying issues by sharing experience Reviewing options to improve IBR modeling accuracy, computation speed, use of test results. Presenting related research by EPRI and PG&E (DOE project) Desired Outcomes: Provide technical update for participants Get feedback and suggestions for ongoing research Improve research collaboration

IBR, Protection Challenges, dynamic response, IBR ↗

(SPT-)LSM theorems from projective non-invertible symmetries

Projective symmetries are ubiquitous in quantum lattice models and can be leveraged to constrain their phase diagram and entanglement structure. In this paper, we investigate the consequences of projective algebras formed by non-invertible symmetries and lattice translations in a generalized 1+1 1 + 1 D quantum XY model based on group-valued qudits. This model is specified by a finite group G G and enjoys a projective \mathsf{Rep}(G)× Z(G) 𝖱 𝖾 𝗉 ( G ) × Z ( G ) and translation symmetry, where symmetry operators obey a projective algebra in the presence of symmetry defects. For invertible symmetries, such projective algebras imply Lieb-Schultz-Mattis (LSM) anomalies. However, this is not generally true for non-invertible symmetries, and we derive a condition on G G for the existence of an LSM anomaly. When this condition is not met, we prove an SPT-LSM theorem: any unique and gapped ground state is necessarily a non-invertible weak symmetry protected topological (SPT) state with non-trivial entanglement, for which we construct an example fixed-point Hamiltonian. The projectivity also affects the dual symmetries after gauging \mathsf{Rep}(G)× Z(G) 𝖱 𝖾 𝗉 ( G ) × Z ( G ) sub-symmetries, giving rise to non-Abelian and non-invertible dipole symmetries, as well as non-invertible translations. We complement our analysis with the SymTFT, where the projectivity causes it to be a topological order non-trivially enriched by translations. Throughout the paper, we develop techniques for gauging \mathsf{Rep}(G) 𝖱 𝖾 𝗉 ( G ) symmetry and inserting its symmetry defects on the lattice, which are applicable to other non-invertible symmetries.

Pace, Salvatore D. (ORCID:0000000306093335)↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Transient Stability Analysis of Direct Droop-Controlled Grid-Forming Inverter with Current Clipping as Current Limiting Control

This paper investigates the transient stability of the direct droop-controlled grid-forming (GFM) inverter which employs the current clipping-based approach for overcurrent limitation. An equivalent circuit model of the direct-droop GFM inverter with current clipping is developed for this purpose. It is shown that during overcurrent conditions, the GFM inverter with current clipping acts as a voltage source with a virtual resistance behind the inverter filters. To compute the parameters of this virtual resistance an analytical expression is given in the paper. Then utilizing the developed circuit, a criteria to exit current limiting during post-fault conditions is given. The developed analytical approaches are then validated through electromagnetic transient (EMT) simulation results in PSCAD software and finally concluding remarks are drawn.

Mohiuddin, Sheik Mohammad↗

Search for the production of a Higgs boson in association with a single top quark in pp collisions at $\sqrt{s}=13$ TeV with the ATLAS detector

A search for the production of a Higgs boson in association with a single top quark, tH, is presented. The analysis uses proton-proton collision data corresponding to an integrated luminosity of 140 fb −1 at a centre-of-mass energy of 13 TeV, collected by the ATLAS detector at the LHC. The search targets Higgs-boson decays into $b\bar{b}$, WW * , ZZ * , and ττ, accompanied by an isolated lepton (electron or muon) from the top-quark decay. Multivariate techniques are employed to enhance the separation between signal and background processes. The observed signal strength, μ tH , defined as the ratio between the measured cross-section and the predicted Standard Model value, is μ tH = 8.1 ± 2.6 (stat.) ± 2.0 (syst.). The significance of the observed (expected) signal above the background-only expectation is 2.8 (0.4) standard deviations. The corresponding observed (expected) upper limit at the 95% confidence level on the tH cross-section is found to be 13.9 (6.1) times the value predicted by the Standard Model. An interpretation with an inverted sign of the top-quark Yukawa coupling is performed, and the signal strength and corresponding limit are reported.

Hadron-Hadron Scattering↗

Electromagnetic Transient Simulation of Large-Scale Inverter-Based Resources With High-Granularity

The power grid is undergoing a significant transformation with the rapid increase in inverter-based resources (IBRs), including large-scale photovoltaic (PV) plants. Ensuring reliable and resilient grid operation in this new paradigm necessitates high-granularity electromagnetic transient (EMT) modeling that accurately captures the behavior of individual inverters and their interactions within IBR plants. Central to this approach is the detailed representation of both the IBR plant’s collector system and the dynamics of individual inverters. To achieve this, a high-granularity EMT model of a large-scale PV plant has been developed using advanced simulation algorithms, including matrix splitting and the Schur complement. These proposed techniques significantly enhance simulation speed, numerical stability, and accuracy while improving the modularity and efficiency of the collector system’s representation. The effectiveness of the proposed methods is validated through simulations of a representative large-scale PV plant consisting of 125 individual PV inverters, 25 IBR unit transformers, and a 52-bus collector system.

Choi, Jongchan [Oak Ridge National Laboratory (ORN↗