Search NASA⌕ Search

SEARCH · Search NASA

Results for “K-alpha”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

75 records · Page 5

Simultaneous NuSTAR and XMM-Newton 0.5-80 KeV Spectroscopy of the Narrow-Line Seyfert 1 Galaxy SWIFT J2127.4+5654

We present a broad-band spectral analysis of the joint XMM-Newton and Nuclear Spectroscopic Telescope Array observational campaign of the narrow-line Seyfert 1 SWIFT J2127.4+5654, consisting of 300 kiloseconds performed during three XMM-Newton orbits. We detect a relativistic broadened iron K-alpha line originating from the innermost regions of the accretion disc surrounding the central black hole, from which we infer an intermediate spin of a = 0.58 (sup +0.11) (sub −0.17). The intrinsic spectrum is steep (gamma = 2.08 plus or minus 0.01) as commonly found in narrow-line Seyfert 1 galaxies, while the cutoff energy (E (sub c) = 108 (sup +11) (sub −10) kiloelectronvolts) falls within the range observed in broad-line Seyfert 1 galaxies. We measure a low-frequency lag that increases steadily with energy, while at high frequencies, there is a clear lag following the shape of the broad Fe K emission line. Interestingly, the observed Fe K lag in SWIFT J2127.4+5654 is not as broad as in other sources that have maximally spinning black holes. The lag amplitude suggests a continuum-to-reprocessor distance of about 10-20 radius of gyration. These timing results independently support an intermediate black hole spin and a compact corona.

Nuclear Spectroscopic Telescope Array↗

Spectrally Resolving High Redshift Dual AGNs with the Line Emission Mapper

The Line Emission Mapper (LEM) is an X-ray Probe-class Mission concept which combines 1-2 eV spectral resolution in the soft X-ray band (0.2-2 keV) with an effective area of ~2600 cm^2 at 1 keV, and 10’’ HPD over a large 30'x30' field of view. The mission will directly address the Astro2020 Decadal Report’s Priority Area of Unveiling the Drivers of Galaxy Growth through the study of merging galaxies, which offer one of the most dramatic channels for galaxy growth and evolution and can potentially trigger both star formation and supermassive black hole (SMBH) growth. Dual and binary AGNs in late-stage mergers are predicted to be a critical stage of merger-induced SMBH growth and coincide with the most transformative period for the host galaxies. Thus, dual and binary AGNs represent ideal laboratories for studying examples of SMBH-galaxy co-evolution. Recent discoveries of dual AGNs at redshifts of z~>2 have been made via optical observations, but such dual AGNs are inaccessible to current X-ray observatories due to a lack of instrumental capabilities, including sensitivity, spectral and spatial resolution. LEM will be uniquely suited to study AGNs at z > 3, where the intrinsic X-ray power law continuum and Iron K alpha emission line - a nearly ubiquitous signpost for AGN accretion – are redshifted into the LEM bandpass. In this poster, we present a simulation-based study on LEM’s ability to discern dual, binary, and/or clustered AGNs at high redshift. We demonstrate the unique capabilities of LEM to spectrally resolve Iron K-alpha lines emitted by distinct AGNs with sufficient line-of-sight velocity differences, even in cases of convolved point sources. Using a suite of simulations probing a range of velocity differences, line strengths, and column densities, we demonstrate LEM’s ability to constrain the spectral properties of dual AGNs at z>3 for a variety of physically realistic pairings. LEM will uniquely provide crucial constraints on dual AGN environments and activity as a function of redshift and will complement optical and infrared observations from upcoming Extremely Large Telescopes.

Ryan W Pfeifle↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗