Search NASA⌕ Search

SEARCH · Search NASA

Results for “KeV X-rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The X-ray spectrum of NGC 5128.

Evaluation of the X-ray spectrum of NGC 5128 (Cen A) obtained by sounding rocket and balloon observations in the range from 1 to 180 keV. NGC 5128 may be fitted by a power law with a photon index -2 less than or equal to n less than or equal to -1.45. Inverse Compton models are presented, and constraints on their parameters are discussed. In all such models, the electrons and magnetic field have not yet equilibrated. Alternatively, the X rays may originate in a compact central core source.

Lampton, M.↗

SuperHERO X-ray Telescope Balloon Mission

The SuperHERO hard X-ray telescope will observe extended sources at unprecedented imaging resolution, revealing the origins of non-thermal emission in extreme astrophysical environments. Employing NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon platform, SuperHERO consists of seven identical, co-aligned telescopes with a combined effective area of 45 cm² at 30 keV. SuperHERO was selected in the APRA 2023 call as a five-year mission, with an inaugural two-day flight scheduled from Fort Sumner, New Mexico, in the fall of 2028. For its initial target, SuperHERO will observe the Crab pulsar wind nebula, localizing hard X-ray emission. Mission development is currently underway, with updates and status to be provided in this presentation.

Nick Thomas↗

A new transient source observed by Uhuru.

A strong X-ray source appeared sometime between March 25 and August 17, 1971. On August 23, its intensity, as observed by the Uhuru satellite, was about twice that of the Crab Nebula, corresponding to about 3 times 10 to the -8th power ergs per sq cm per sec, in the range 2-6 keV. On December 20, 1971, its intensity had declined to one-tenth of that value in the same energy range. Its spectrum was quite steep, and fit a power law with an average energy spectral index of 3.0. The variation of X-ray intensity over a 5-month period shows qualitative differences from the previously observed transient X-ray sources, Cen XR-2 and Cen XR-4.

Matilsky, T. A.↗

X-ray emission from the Magellanic Clouds observed by Uhuru.

Description of three sources in the Large Magellanic Cloud and one in the Small Cloud which have been discovered by Uhuru. These sources each emit about 10 to the 38th erg/sec in the 2- to 7-keV band, and they account for more than 90% of the total emission from the Clouds. The source in the Small Cloud shows time variability on time scales of hours.

Leong, C.↗

A Satellite Borne Cadmium Sulfide Total Corpuscular Energy Detector

The properties of single crystals of cadmium sulfide as radiation detectors are described. It has been found possible to select crystals such that: (a) The ratio of increase of conductivity under irradiation to the rate of absorption of energy in the crystal is substantially independent of particle energy (over the examined ranges of 500 ev to 80 kev for electrons and 5 kev to 180 kev for protons) and of the magnitude of energy flux (over the range from.005 to 10 ergs/cm(sup 2 -sec); and (b) The above ration is substantially the same for protons, electrons, alpha particles, x-rays, and gamma-rays. For a driving voltage of 100 volts, typical crystal yield currents of 10(sup -7) to 10(sup- 6) amperes for each erg/cm(sup 2-sec) of energy absorbed by the crystal. The threshold of such crystal detectors (resulting from dark currents of the order of 10(sup 10 amp) is typically 10(sup -3) ergs/cm(sup 2- sec). For the selected crystals a response-temperature coefficient of -0.25% per degree centigrade is found for the temperature range -50 deg C to + 50 deg C. A description is given of a complete CdS total corpuscular energy detector for the study of geomagnetically trapped radiation by means of a satellite. The detector described has a dynamic range great than 10(sup 4), a solid angle of 10(exp -3) steradian, and a detection threshold of approximately 1 erg/cm(sup 2-sec-sterad). A similar detector employing a small magnet for the selective exclusion of electrons is also described. Noteworthy practical features of these detectors for satellite and space probe experiments are: (a) Use of bare crystals, without covering foils, in order to detect charged particles having energies as low as hundreds of electron volts. (b) Simplicity of electronic auxiliaries. (c) Compactness, lightweight and nechanical ruggedness. (d) Low electrical power requirements; and (e) Conversion of conduction current to the rate of a twostate relaxation oscillator in order to facilitate telemetric transmission of data. A pair of such detectors was flown as part of the s-46 satellite payload on March 23, 1960, but due to vehicular failure an orbit was not achieved and the operation of the CdS detectors was observed for only, six minutes of flight.

Freeman, John W.↗

Long term temporal variations of the hard X-ray flux from the Centaurus region

The X-ray telescope aboard the third Orbiting Solar Observatory (OSO-3) observed the Centaurus region daily from 1967 October to 1968 February, and also for five days in 1968 June. A stable minimum flux of 0.33 + or - 0.03 photons (sq cm sec)/1 between 7.7 and 38 keV from a source around l = 305 deg is derived. Several single days show enhanced fluxes, and two extensive flaring episodes, one with a soft and the other a very hard spectrum, lasting at least ten days.

Schwartz, D. A.↗

The HEROIX Broadband X-Ray Space Telescope Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept envisions a next-generation broadband X-ray observatory designed to meet the astrophysics community’s need for high-angular-resolution studies of the Cosmic X-ray Background. Building on the science legacy of NASA’s NuSTAR mission and more than 30 years of advances in replicated NiCo shell technology at NASA Marshall, HEROIX proposes a space observatory comprising four co-aligned telescopes achieving 5 arcsecond half-power diameter (HPD) angular resolution. This capability, approached by the resolution demonstrated in the FOXSI-4 sounding rocket mission and under development through the SuperHERO balloon mission, will be extended to energies up to 80 keV through multilayer coatings. Marshall’s inhouse precision optics manufacturing enables an integrated effective area of 380 cm² at 30 keV, which, combined with high-resolution optics, opens new windows into extreme astrophysical non-thermal processes.

Nick Thomas↗

Direct observations of low-energy solar electrons associated with a type 3 solar radio burst

On 6 April 1971 a solar X-ray flare and a type 3 solar radio noise burst were observed with instrumentation on the eccentric-orbiting satellite IMP 6. The type 3 solar radio noise burst was detected down to a frequency of 31 kHz. A highly anisotropic packet of low-energy solar electron intensities arrived at the satellite approximately 6000 seconds after the onset of the solar flare. This packet of solar electron intensities was observed for 4200 seconds. Maximum differential intensities of the solar electrons were in the energy range of one to several keV. The frequency drift rate of the type 3 radio noise at frequencies below 178 kHz also indicated an average particle speed corresponding to that of a 3-keV electron. The simultaneous observations of these solar electron intensities and of the type 3 solar radio burst are presented, and their interrelationships are explored.

Frank, L. A.↗

Electron beam parallel X-ray generator

Broad X ray source produces a highly collimated beam of low energy X rays - a beam with 2 to 5 arc minutes of divergence at energies between 1 and 6 keV in less than 5 feet. The X ray beam is generated by electron bombardment of a target from a large area electron gun.

Payne, P.↗

A Bragg spectrometer for stellar X-ray astronomy.

Poor energy resolution and the steeply varying continuum spectrum make it impossible to obtain with proportional counters an unambiguous identification of certain emission features of Sco X-1. For this reason a Bragg crystal spectrometer was constructed. The instrument, flown successfully aboard an Aerobee-170 rocket, scanned the spectral range from 2.4 to 2.9 keV. The spectrometer consists of two large reflecting crystals of synthetic graphite. The results obtained during the flight of the instrument clearly indicate that the Bragg method can yield much higher sensitivity to line emission than can proportional counter methods.

Kestenbaum, H.↗

Design of the solar X-ray instrument for OSO-H.

The OSO-H solar X-ray instrument monitors X rays from the sun in the energy range 1-300 keV, as well as the charged particle background. The electronics provide accurate logarithmic pulse-height analysis at the high counting rates expected under flare conditions. A high time resolution mode enables tudy the temporal development of a solar flare.

Harrington, T. M.↗

Anomalous minima in Cen X-3.

Report of an observation made with a rocket-borne argon-methane proportional counter, which was equipped with a 'Mylar' window and was sensitive to X rays in the range from 0.2 to 10 keV. During a scan of the galactic plane, the detector passed directly over the location of Cen X-3 at a roll rate of 1 deg per second. An extended minimum of X-ray flux was observed. It is concluded that the anomalous effect is intrinsic to the source.

Margon, B.↗