Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Classified library critical in Lab’s Annual Assessment of weapons to U.S. President. National Security Resource Center’s collections are the foundation to stockpile confidence

One of the most important accomplishments every year at LANL is a letter sent by the Laboratory Director that ultimately reaches the President of the United States. The subject is the current state of the weapons for which the Lab is responsible. Known as the Annual Assessment letter, it is a culmination of nearly 14 months’ worth of work and the contributions of more than 1,000 Lab staff members. Its classified contents come from the Lab’s Annual Assessment, which is an approximately 100-page document evaluating the safety, security and effectiveness of the stockpile.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

This St. Patrick’s Day, take a look at “lucky” Lab artifacts from the Manhattan Project

What luck! Tucked inside J. Robert Oppenheimer’s book Bhagavad-Gita is a four-leaf clover. The famed physicist and first Lab director regularly quoted the Hindu scripture, most notably upon witnessing the Trinity test, which was the successful detonation of the first-ever Los Alamos created atomic bomb. Oppenheimer was said to have recalled the line, “Now I am become Death, the destroyer of worlds.” (The quote, though, has been widely misinterpreted.) The clover is taped to what appears to be a calling card from his spouse Kitty and was found inside his copy of the Bhagavad Gita, which was donated to the Lab’s Bradbury Science Museum by private donors Ben and Sara Beck Svetitsky in early 2020. Kitty Oppenheimer was educated as a botanist and biologist, and accompanied her husband to Los Alamos, along with their two children. The family was here in 1943 through the end of World War II in 1945. The book, with the card found inside, makes up one of two of J. Robert Oppenheimer’s personal effects within the Lab’s collections.

99 GENERAL AND MISCELLANEOUS↗

Short video provides broad overview of the Lab’s 80-year history

In celebration of the Lab’s 80th anniversary this month, join National Security Research Center Senior Historian, Alan Carr (NSRCMS), as he provides a six-and-a-half-minute overview of the Lab’s history. The video, co-produced by Brian Clayton (CEA-MP) and Howard Coe (CEA-MP), covers three phases of the Lab’s evolution, from a nuclear weapons laboratory, then a nuclear science laboratory, to its manifestation today as a multidisciplinary laboratory.

99 GENERAL AND MISCELLANEOUS↗

A VXS [VITA41] Trigger Processor for the 12GEV Experimental Programs at Jefferson Lab

The VXS_Trigger_Processor [VTP] was developed and commissioned for CLAS12 in the fall of 2016. This board is a VITA41 switch card and it collects data from a variety of front-end TDC and Flash ADC modules. The VTP has since been used in several experiments at Jefferson Lab serving as the L1 trigger module for a variety of detector types, such as stacked calorimeters, strip calorimeters, time-of-flight, Cerenkov, hodoscopes, drift chambers, and silicon strips. Trigger algorithms implemented include cluster finding (1D, 2D), drift chamber segment and road finding, geometry matching between various detectors, particle counting, and general global trigger bit processing. The VTP is also capable of reading out each front-end crate with up to 40Gbps Ethernet which is an enormous increase compared to the currently used 200MB/s VME bus. Recent progress has been made to show that a firmware and software upgrade can enable existing Jefferson Lab front-end crates to operate in a streaming DAQ mode. In February 2020, tests will be performed on a full calorimeter and matched hodoscope which are components of the CLAS12 Forward Tagger detector system with beam in Hall B. This paper details the hardware performance, triggered, and streaming applications that have been implemented using the VTP for several experiments at Jefferson Lab.

ABBOTT, David↗

Technical Learning and Integration of Interns in Advanced Protection Lab Space: Enhancements to Testbed and Experiments to Improve Workflows for Producing Datasets

This report presents a successful technical learning integration of student interns in the Advanced Protection Laboratory space, located in the Grid Research Integration and Deployment Center (GRID-C) at the Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL). The Advanced Protection Laboratory was created for the primary goal of supporting DOE’s research projects and technical staff at ORNL. As a secondary goal, the space was used for collaborating with ORNL’s intern programs, providing support to the lab’s mentors and student interns. In 2024, three student interns spent a summer in the Advanced Protection lab space and were involved in the DarkNet Distributed Ledger Technology (DLT) project. The students had a great opportunity to gain hands-on experience with communication and protective relay equipment focused on information technology, data analytics, and cybersecurity. Experiences in the lab space with real equipment and software integration offer education and professional development for students, which is especially important because of a need in the energy industry to recruit highly skilled power and communication engineers.

42 ENGINEERING↗

Recent developments and operation of polarized photocathodes at Jefferson Lab

Spin-polarized electron sources are critical to a wide range of accelerator-based applications for nuclear and particle physics. At Thomas Jefferson National Accelerator Facility, they play a central role in delivering high-quality polarized beams for precision nuclear physics experiments and next-generation parity-violation measurements, where stringent control of systematic uncertainties is essential. These sources are also expected to be key components of other initiatives, including the Electron-Ion Collider and the potential future positron capabilities at Jefferson Lab. In this talk, I will present ongoing research and development efforts at Jefferson Lab focused on the design, fabrication and optimization of spin-polarized photocathodes. This includes growth using molecular beam epitaxy (MBE) or metal-organic chemical vapor deposition (MOCVD), along with detailed characterization of their performance metrics, such as quantum efficiency (QE), electron spin polarization and QE anisotropy, all of which are increasingly important metrics for polarized electron sources at Jefferson Lab and the Electron-Ion Collider. Strategies to mitigate QE anisotropy, which is critical for reducing helicity-correlated beam asymmetries in precision experiments such as MOLLER will be highlighted. Finally, I will present recent efforts aimed at improving the operational lifetime of spin-polarized photocathodes in injector environments, particularly under high-voltage conditions in DC electron guns. These developments are essential for enabling reliable, high-performance operation of polarized sources for current and future accelerator programs.

Kachwala, Alimohammed [Thomas Jefferson National A↗

μRWELL detector developments at Jefferson Lab for high luminosity experiments

One of the future plans at Jefferson Lab is running electron scattering experiments with large acceptance detectors at luminosities > 10^37 cm^−2 s^−1. These experiments allow the measurements of the Double Deeply Virtual Compton Scattering (DDVCS) reaction, an important physics process in the formalism of Generalized Parton Distributions, which has never been measured because of its small cross-section. The luminosity upgrade of CLAS12 or the SOLID detector makes Jefferson Lab a unique place to measure DDVCS. One of the important components of these high luminosity detectors is a tracking system that can withstand high rates of ≈ 1MHz/cm2. The recently developed Micro-Resistive Well (𝜇RWELL) detector technology is a promising option for such a tracking detector by combining good position resolutions, low material budget with simple mechanical construction, and low production costs. In this proceeding, we will discuss recent developments and studies with 𝜇RWELL detectors at Jefferson Lab for future upgrades of the CLAS12 detector to study the DDVCS reaction.

Hauenstein, Florian↗

Using hypermedia to develop an intelligent tutorial/diagnostic system for the Space Shuttle Main Engine Controller Lab

This is a tutorial/diagnostic system for training personnel in the use of the Space Shuttle Main Engine Controller (SSMEC) Simulation Lab. It also provides a diagnostic capable of isolating lab failures at least to the major lab component. The system was implemented using Hypercard, which is an program of hypermedia running on Apple Macintosh computers. Hypercard proved to be a viable platform for the development and use of sophisticated tutorial systems and moderately capable diagnostic systems. This tutorial/diagnostic system uses the basic Hypercard tools to provide the tutorial. The diagnostic part of the system uses a simple interpreter written in the Hypercard language (Hypertalk) to implement the backward chaining rule based logic commonly found in diagnostic systems using Prolog. Some of the advantages of Hypercard in developing this type of system include sophisticated graphics, animation, sound and voice capabilities, its ability as a hypermedia tool, and its ability to include digitized pictures. The major disadvantage is the slow execution time for evaluation of rules (due to the interpretive processing of the language). Other disadvantages include the limitation on the size of the cards, that color is not supported, that it does not support grey scale graphics, and its lack of selectable fonts for text fields.

Oreilly, Daniel↗

An update on Lab Rover: A hospital material transporter

The development of a hospital material transporter, 'Lab Rover', is described. Conventional material transport now utilizes people power, push carts, pneumatic tubes and tracked vehicles. Hospitals are faced with enormous pressure to reduce operating costs. Cyberotics, Inc. developed an Autonomous Intelligent Vehicle (AIV). This battery operated service robot was designed specifically for health care institutions. Applications for the AIV include distribution of clinical lab samples, pharmacy drugs, administrative records, x-ray distribution, meal tray delivery, and certain emergency room applications. The first AIV was installed at Lahey Clinic in Burlington, Mass. Lab Rover was beta tested for one year and has been 'on line' for an additional 2 years.

Mattaboni, Paul↗

The NASA Langley Isolator Dynamics Research Lab

The Isolator Dynamics Research Lab (IDRL) is under construction at the NASA Langley Research Center in Hampton, Virginia. A unique test apparatus is being fabricated to support both wall and in-stream measurements for investigating the internal flow of a dual-mode scramjet isolator model. The test section is 24 inches long with a 1-inch by 2-inch cross sectional area and is supplied with unheated, dry air through a Mach 2.5 converging-diverging nozzle. The test section is being fabricated with two sets (glass and metallic) of interchangeable sidewalls to support flow visualization and laser-based measurement techniques as well as static pressure, wall temperature, and high frequency pressure measurements. During 2010, a CFD code validation experiment will be conducted in the lab in support of NASA s Fundamental Aerodynamics Program. This paper describes the mechanical design of the Isolator Dynamics Research Lab test apparatus and presents a summary of the measurement techniques planned for investigating the internal flow field of a scramjet isolator model.

Middleton, Troy F.↗

The Development of MSFC Usability Lab

This conference poster reviews the development of the usability lab at Marshall Space Flight Center. The purpose of the lab was to integrate a fully functioning usability laboratory to provide a resource for future human factor assessments. and to implement preliminary usability testing on a MSFC website to validate the functionality of the lab.

Cheng, Yiwei↗

Narrowing lab–to–market gaps: Device innovations in fuel generation, solar–cell, and photodetection

Academic translational research efforts to industry are often an underlying sought–after goal among various researchers. Through the interchanges of research endeavors between academia–industry, great innovations can/has been achieved that cater to the real–world application by bridging “industrially relevant” problem solving with pursuing fundamental studies. It is pertinent that most of the studies from university–level research works may not translate into demonstrable market products due to various reasons. Funding support, individual researcher goals, socioeconomic factors, and most importantly the technical know–how of generating revenue strategies for startups, are a few of the factors that have slowed the pace of collaborative efforts. However, we believe that the most crucial component is the identification of the critical parameters that solve long–standing problems that hinder the scale–up of the lab scale research into marketable products considering the techno–economic analysis. Here, to illustrate this, we take the three most relevant examples of devices for fuel generation, devices to utilize solar radiation, and devices for detection and other related applications. In this perspective, we provide an in–depth case study of each of these critical parameters to comment on the direction of research avenues that can serve as step–stones for the commercialization of university–level lab research studies.

42 ENGINEERING↗

Evaluation of Exterior Shades at PNNL Lab Homes and Occupied Field Sites (Final Report)

In residential applications, heat transfer through windows accounts for a significant portion of a home’s cooling load. Exterior shades are window attachments that can be applied on the exterior-side of windows in a home. Exterior shades can reduce solar heat gain, reduce glare through a window, and improve comfort in the home. To assess the performance of residential exterior shades, the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (BTO) commissioned a series of field studies for exterior fabric shades to be performed by Pacific Northwest National Laboratory (PNNL) during the cooling seasons of 2019 and 2020. This report describes the experimental setup and results of these exterior shade field studies. PNNL, in collaboration with Lawrence Berkeley National Laboratory (LBNL), evaluated exterior shades at the PNNL Lab Homes and three occupied field sites in Richland, Washington. At the Lab Homes, the energy performance of exterior shades was evaluated in a controlled side-by-side environment. At the occupied field sites, exterior shades were characterized by measuring shade usage, documenting installation practices, and surveying customer perspectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LABS: Los Alamos Benchmark Suite - Current status and planning [Slides]

The LABS repository now has over 500 verified and revised input files with about 600 input files left to get up to speed with what we currently use. After that there are many, many more to go. We're in the process of building code infrastructure, moving to template output files, automating input file generation, outputting file data mining for calculation results, and benchmarking selection on sensitivity and other benchmark characteristics. We intend to open source LABS. We'll most likely release the input files sooner rather than later. The associated tool will probably be open sourced later.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine Learning for Optimized Polarization at Jefferson Lab

Polarized cryo-targets and polarized photon beams are widely used in experiments at Jefferson Lab. Traditional methods for maintaining the optimal polarization involve manual adjustments throughout data taking by human shift takers. This may introduce some level of inconsistency simply due to the wide variety of experience and expertise of the shift takers themselves. Implementing machine learning-based control systems can improve the stability of the polarization without relying on human intervention. The cryo-target polarization is influenced by temperature, microwave energy, the distribution of paramagnetic radicals, as well as operational conditions including the radiation dose. Diamond radiators are used to generate linearly polarized photons from a primary electron beam. The energy spectrum of these photons can drift over time due to changes in the primary electron beam conditions and diamond degradation. As a first step towards automating the continuous optimization and control processes, uncertainty aware surrogate models have been developed to predict the polarization based on historical data. This talk will provide an overview of the use cases and models developed, highlighting the collaboration between data scientists and physicists at Jefferson Lab.

Jeske, Torri [Thomas Jefferson National Accelerato↗

Dynamic thermal behavior of polycrystalline LaB 6 hollow cathodes

Lanthanum hexaboride (LaB6) hollow cathodes have demonstrated a capability for long life operation, which is critical to many space exploration missions. Thermal characterization of LaB6 hollow cathodes has revealed lower than expected electron emitter temperatures when the cathode reaches a steady state. This phenomenon is observed at discharge currents ranging from 5 to 35 A and xenon mass flow rates of 5–25 SCCM in cathodes with three different orifice diameters. Thus, the currently accepted value of the work function for polycrystalline LaB 6 , 2.67 eV, does not describe well the emission characteristics of LaB6 hollow cathodes operating with internal gas discharges at a steady state. We use empirically measured temperatures combined with a model of the hollow cathode emitter and xenon discharge to estimate the value of the work function, yielding a value ranging from 2.1 to 2.44 eV. This lower work function value implies that LaB6 hollow cathodes are expected to have even longer lifetimes than previously anticipated, further establishing them as a more suited alternative to other conventional cathode technologies for the task of long duration travel. Direct measurements of the work function as a function of depth on a hollow cathode emitter using x-ray photoelectron spectroscopy and ion beam milling indicate that the work function decreases with depth. We postulate several mechanisms that could explain the observed work function enhancement. Altogether, our results have important implications to the design, study approach, and operation of LaB 6 cathodes and potentially other cathodes with hollow configuration. Finally, our work opens the question of why the work function is reduced upon interaction with Xe plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using AI to predict calibration constants for the central drift chamber in GlueX at Jefferson Lab

The AI for Experimental Controls project team at Jefferson Lab has developed an AI system to control and calibrate a large drift chamber system in near-real time. The AI system will monitor environmental and experimental variables to recommend voltage settings that maintain consistent dE/dx gain and optimal resolution throughout the experiment. At present, calibrations are performed after data have been recorded and require a considerable amount of time and attention from experts. The calibrations currently require multiple iterations and depend on accurate tracking information. Our approach uses environmental data, such as atmospheric pressure and gas temperature, and beam conditions, such as the flux of incident particles, as inputs to a Gaussian Process Regression (GPR) model. For the data taken during the GlueX 2020 run period, the GPR is able to predict the existing gain correction factors to within 3.5%. This talk will briefly describe the development, testing, and future plans for this system at Jefferson Lab.

Jeske, Torri↗

Commissioning of a replacement subatmospheric cold box for Jefferson Lab’s Central Helium Liquefier

Jefferson Lab’s Cryogenics Department has designed, fabricated, installed, and commissioned a new subatmospheric cold box to replace one of the two existing units within our Central Helium Liquefier (CHL). The replacement cold box, dubbed SC1R, pumps saturated helium vapor at 0.0385 atm from Jefferson Lab’s continuous electron beam accelerator facility (CEBAF) cryomodules to maintain an operating temperature of nominally 2.1 K. This is accomplished using a five-stage cryogenic centrifugal compressor (cold compressor) system and a brazed aluminum plate-fin heat exchanger operating between 2.1 K and 4.5 K. In this paper we will describe our experience commissioning the SC1R cold box. We will discuss pump-down of the system to 2.1 K and steady-state operation at the cold compressor design flow rates of 170, 200, and 250 g/s. Performance of the heat exchanger and cold compressors has been mapped across a range of flow rates and optimized for CEBAF operations. This commissioning data will be used to monitor future performance and adapt to changing load requirements.

Mastracci, B.↗