Search NASA⌕ Search

SEARCH · Search NASA

Results for “LANGMUIR PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Area influences and floating potentials in Langmuir probe measurements.

Analysis of the influence of a relatively small reference electrode on a Langmuir probe measurement of plasma density and temperature. The analysis employs the collisionless theory of Laframboise for spherical and cylindrical probes and in a completely general way includes a broad range of electron densities and temperatures, as well as all possible values of ion mass and multiplicity of ionization. It is shown that a ratio alpha of reference-electrode area to probe area of 10,000 will guarantee no distortion of the measurement as a result of a shifting reference-electrode potential. It is further shown that the constraint on alpha can be relaxed by approximately two orders of magnitude when the charge-normalized ion mass is decreased from 200 to 1 amu and the ratio of reference-electrode radius to Debye length is decreased from 100 to 0. An additional result of the analysis is the dependence of a probe's floating potential on its geometry and radius, as well as on the properties of the plasma. A discussion of the latter result reveals in a striking manner the significant differences between the ion-current responses of spherical and cylindrical probes.

Szuszczewicz, E. P.↗

A statistical study of the subauroral electron temperature enhancement using dynamics Explorer 2 Langmuir probe observations

A statistical study of the subauroral electron temperature enhancement was undertaken using Langmuir probe observations during 488 traversals of the midlatitude plasmapause region by the DE-2 satellite. The subauroral electron temperature enhancement on the nightside is a quasi-permanent feature at all altitudes between 350 and 1000 km with an occurrence frequency that depends on altitude. The occurrence frequency of the subauroral electron temperature peak has a strong altitude dependence on the dayside. The position of the subauroral Te peak decreases with increasing magnetic activity in a manner similar to that of the equatorial plasmapause and other midlatitude plasmapause signatures.

Kozyra, J. U.↗

Overview of the Langmuir probe system on the Mega Ampere Spherical Tokamak (MAST) Upgrade

A detailed description of the Langmuir probe system on Mega Ampere Spherical Tokamak Upgrade is presented. The system features 850 tile-embedded probes and 40 bespoke electronic modules that each have the capability to drive and acquire data from up to 16 probes in a time-multiplexed manner. The system provides spatiotemporal-resolved measurements (1 cm and ~1 ms, respectively) in the divertor region of ion saturation current, electron temperature, and floating potential. The standard interpretation of current-voltage (IV) characteristics is to apply a four-parameter fit, based on unmagnetized probe theory, which includes a linear model for the ion saturation region. In conclusion, to mitigate the effect of the magnetic field, analysis is restricted to the region of the IV characteristic, which is sensitive to only the tail of the electron energy distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Langmuir probe system in the Wendelstein 7-X test divertor

Here, the design and evaluation of the Langmuir probe system used in the first divertor operation phase of Wendelstein 7-X is described. The probes are integrated into the target plates and have individually facetted surfaces to keep the angle of incidence of the magnetic field within an appropriate range for different magnetic configurations. Multiple models for the derivation of plasma parameters from current–voltage characteristics are introduced. These are analyzed with regard to their assumptions and limitations, generalized, and adapted to our use case. A detailed comparison is made to determine the most suitable model. It is found that the choice of model has a large impact, for example, resulting in a change in the inferred temperatures of up to a factor two. This evaluation is implemented in a Bayesian modeling framework and automated to allow for joint analysis with other diagnostics and a replacement of ad hoc assumptions. We rigorously treat parameter uncertainties, revealing strong correlations between them. General and flexible model formulations permit an expansion to additional effects.

47 OTHER INSTRUMENTATION↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

We report for the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I–V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I–V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field($\widetilde{f}$ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

47 OTHER INSTRUMENTATION↗

Langmuir-Probe Measurements in Flowing-Afterglow Plasmas

The validity of the orbital-motion theory for cylindrical Langmuir probes immersed in flowing- afterglow plasmas is investigated experimentally. It is found that the probe currents scale linearly with probe area only for electron-collecting but not for ion-collecting probes. In general, no agreement is found between the ion and electron densities derived from the probe currents. Measurements in recombining plasmas support the conclusion that only the electron densities derived from probe measurements can be trusted to be of acceptable accuracy. This paper also includes a brief derivation of the orbital-motion theory, a discussion of perturbations of the plasma by the probe current, and the interpretation of plasma velocities obtained from probe measurements.

Johnsen, R.↗

The Fixed-Bias Langmuir Probe on the Communication-Navigation Outage Forecast System Satellite: Calibration and Validation

A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasma density is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future fixed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.

Vector Electric Field Instrument↗

Solar EUV index for aeronomical studies at earth from Langmuir probe photoelectron measurements on the Pioneer Venus orbiter

A solar EUV index for aeronomical studies at earth, obtained from the Langmuir probe measurement of photoelectron current on the Pioneer Venus orbiter, is presented. To examine the potential of E sub EUV as a solar EUV flux index, the behavior of ionospheric parameters f sub 0 E, f sub 0 F1, and f sub 0 F2 are studied at midlatitude stations, and their relationship with E sub EUV and with the 10.7-cm solar radio flux is compared. f sub 0 F1 and f sub 0 F2 are found to be better correlated with E sub EUV than with the 10.7-cm flux. F sub 0 E is better correlated with the 10.7-cm flux, because the 10.7-cm flux is also a proxy for soft X-rays, which are an important ionizing source in the E region. A table is also presented for the EUV index, E sub EUV, for the period February 12, 1979, through most of 1991.

Hoegy, W. R.↗

Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft Particle Spectrometer, Langmuir Probe, and Data Analysis for Aerospace Magnetospheric/Thermospheric Coupling Rocket Program

Under this grant two instruments, a soft particle spectrometer and a Langmuir probe, were refurbished and calibrated, and flown on three instrumented rocket payloads as part of the Magnetosphere/Thermosphere Coupling program. The flights took place at the Poker Flat Research Range on February 12, 1994 (T(sub o) = 1316:00 UT), February 2, 1995 (T(sub o) = 1527:20 UT), and November 27, 1995 (T(sub o) = 0807:24 UT). In this report the observations of the particle instrumentation flown on all three of the flights are described, and brief descriptions of relevant geophysical activity for each flight are provided. Calibrations of the particle instrumentation for all ARIA flights are also provided.

Sharber, J. R.↗