Search NASA⌕ Search

SEARCH · Search NASA

Results for “LArTPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Search for Heavy Neutral Leptons in the MicroBooNE LArTPC

aHeavy Neutral Leptons (HNLs) offer a possible extension of the Standard Model via mixing with the three active neutrino flavours. HNLs with masses between 1 and 493 MeV can be produced from kaon and pion decays in the high-intensity Booster Neutrino Beam. These particles would then travel to the MicroBooNE detector where some fraction would decay in-flight to detectable Standard Model particles. This poster presents work to perform the first search for these particles in a liquid argon TPC. A number of methods are used to distinguish the HNL decays from the neutrino and cosmic ray background including utilising the time of flight of the massive HNL with respect to the active neutrinos. As the first search of its kind in a LArTPC this work pioneers techniques applicable for future large scale searches in the both the full Short Baseline Neutrino program and DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

$\nu_e$ CC Event Identification Based on Shower Energy Profiles in LArTPCs

• Neutrino oscillations → Neutrinos have mass. Insight into physics beyond the Standard Model. • Liquid Argon Time Projection Chamber (LArTPC): - Distinguish between $e^-$ and $\gamma$ electromagnetic showers. - Exceptional calorimetry and tracking capabilities. • Weak interaction: - Neutral current (NC): $\nu_e \eta \to \nu_e \eta$ - Charged current (CC): $\nu_e \eta \to e^- p$ • Goal: Identify and select $e^-$ showers to do $\nu_e$ CC analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elimination LArTPC Simulation Uncertainty

Liquid Argon Time Projection Chambers (LArTPC) are crucial for measuring muons and neutrinos by capturing the paths of fast-moving particles through argon gas. However, these detectors face challenges such as electron-ion recombination, diffusion, and attenuation, which introduce uncertainties in simulation models. This study, conducted by Ka ren Mkrtchyan at FERMILAB, aims to reduce these uncertainties by adjusting the amplitude and width of signals detected by the TPC wires. Initial findings indicate that the current modification algorithm requires further refinement to better align simulations with observed data. Ongoing work focuses on correcting computational bugs and enhancing the simulation model for improved accuracy and statistical confidence.

Mkrtchyan, Ka'ren↗

Optimizing ICEBERG LArTPC Run Configuration for Data Collection

To ensure accurate data collection and diagnostics of the ICEBERG electronics, simulation runs were completed using a pulser to mimic charge deposition on the LArTPC wires and collect data for analysis and calibration. This analysis is essential for optimizing the detector's performance by identifying the optimal range of DAC values that avoid saturation zones and provide the best experimental results for real non-pulser runs.

Ganguly, Neil↗

Testing, Operation, and Analysis of a Photosensitive LArTPC

TinyTPC, a compact LArTPC with a pixelated readout system (LArPix), aims to improve energy measurements for low-energy events by enhancing ionization charge collection. It explores the effects of photosensitive dopants and xenon in liquid argon. An initial look at adding photosensitive dopant isobutylene found a 5% charge enhancement.

McCright, Hannah↗

Elimination LArTPC Simulation Uncertainty With Modifcations to TPC Wire Waveforms

This paper introduces a novel approach to reducing systematic uncertainties in LArTPC detector simulations, which arise from known detector effects that are challenging and computationally intensive to model. The proposed method involves modifying simulated waveforms based on observed discrepancies in ionization signals from the TPC between actual data and simulations. This approach reduces the sensitivity to detailed detector modeling and decreases the computational resources required for accurate simulations.

Mktchyan, Karen↗

Optimization and Analysis of ICEBERG LArTPC Run Configuration for Data Collection

This paper presents the findings from the ICEBERG project at Fermilab, focusing on the development and optimization of Liquid Argon Time Projection Chamber (LArTPC) detectors for the DUNE project. Various parameters, including Vref, gain, and peak time, were systematically varied to ensure accurate data collection and diagnostics. The analysis revealed optimal settings that enhance the detector's performance, paving the way for improved neutrino detection and research.

Ganguly, Neil↗

LAr1-ND: Testing Neutrino Anomalies with Multiple LArTPC Detectors at Fermilab

This white paper describes LAr1-ND and the compelling physics it brings first in Phase 1 and next towards the full LAr1 program. In addition, LAr1-ND serves as a key step in the development toward large-scale LArTPC detectors. Its development goals will encompass testing existing and possibly innovative designs for LBNE while at the same time providing a training ground for teams working towards LBNE combining timely neutrino physics with experience in detector development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis and Validation of PMT s Waveforms in ICARUS LArTPC Using Monte Carlo Simulations

ICARUS (Imaging Cosmic and Rare Underground Signals) serves as the Far Detector in the Short Baseline Neutrino (SBN) program at Fermilab, playing a central role in investigating the potential existence of sterile neutrinos in the eV squared mass range. The detector consists of two large Liquid Argon Time Projection Chambers (LArTPCs) with a total capacity of 760 tons of liquid Argon. A key component of the system is its array of 360 Photo-Multiplier Tubes (PMTs), which detect the scintillation light produced by charged particles in liquid Argon; the fast scintillation signal enables accurate event timing, triggering, and reconstruction. Together with the TPC and CRT systems, the PMTs ensure precise interaction time measurements, which are crucial for distinguishing neutrino interactions from cosmic-ray backgrounds. ICARUS uses Hamamatsu R5912-MOD PMTs, optimized for cryogenic temperatures, with high quantum efficiency, excellent timing resolution, low dark current (around 10 nA at 1500 V), and broad spectral sensitivity (300–650 nm). These characteristics are crucial for the efficient detection of scintillation light. Analyzing the waveforms of PMT signals allows for a detailed comparison between experimental data and Monte Carlo simulations. This analysis is fundamental for improving the accuracy of neutrino event reconstruction, enhancing detector calibration, and optimizing the detector's performance for current and future operations.

Brio, V. [Catania U.] (ORCID:0009000088807391)↗

Muon momentum reconstruction in ICARUS-T600 LArTPC via Multiple Scattering

The SBN program at Fermilab investigates the possible existence of eV-scale sterile neutrinos. This work focuses on reconstructing muon momentum in $\nu$-Ar interactions within the ICARUS-T600 LArTPC detector using Multiple Coulomb Scattering (MCS), the only viable method for non-contained muons. Two algorithms are evaluated: the Gran Sasso algorithm (2D, Collection view) and the MicroBooNE algorithm (3D angles), applied to 2391 simulated and 2255 real stopping muon tracks (0.4-1 GeV/c). Performance is assessed via bias and resolution, using range-based momentum as a reference. Two enhanced versions of the Gran Sasso algorithm are also developed: one combining all three wire plane views, and one using 3D angles. Results show that the MicroBooNE algorithm performs slightly better, with resolution down to 14\% in simulation and 16\% in real data. These improvements significantly boost $\nu_\mu$ CC statistics, enhancing sensitivity to $\nu_\mu$ disappearance and 3+1 oscillation signals.

Chiello, Giovanni [Pisa U.] (ORCID:000900064571071↗

Measurement of cosmic-ray reconstruction efficiencies in the MicroBooNE LArTPC using a small external cosmic-ray counter

The MicroBooNE detector is a liquid argon time projection chamber at Fermilab designed to study short-baseline neutrino oscillations and neutrino-argon interaction cross-section. Due to its location near the surface, a good understanding of cosmic muons as a source of backgrounds is of fundamental importance for the experiment. We present a method of using an external 0.5 m (L) x 0.5 m (W) muon counter stack, installed above the main detector, to determine the cosmic-ray reconstruction efficiency in MicroBooNE. Data are acquired with this external muon counter stack placed in three different positions, corresponding to cosmic rays intersecting different parts of the detector. The data reconstruction efficiency of tracks in the detector is found to be $\epsilon_{\mathrm{data}}=(97.1\pm0.1~(\mathrm{stat}) \pm 1.4~(\mathrm{sys}))\%$, in good agreement with the Monte Carlo reconstruction efficiency $\epsilon_{\mathrm{MC}} = (97.4\pm0.1)\%$. This analysis represents a small-scale demonstration of the method that can be used with future data coming from a recently installed cosmic-ray tagger system, which will be able to tag $\approx80\%$ of the cosmic rays passing through the MicroBooNE detector.

47 OTHER INSTRUMENTATION↗

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The 3×1×1 m3 demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performance of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wire-cell 3D pattern recognition techniques for neutrino event reconstruction in large LArTPCs: algorithm description and quantitative evaluation with MicroBooNE simulation

Wire-Cell is a 3D event reconstruction package for liquid argon time projection chambers. Through geometry, time, and drifted charge from multiple readout wire planes, 3D space points with associated charge are reconstructed prior to the pattern recognition stage. Pattern recognition techniques, including track trajectory and dQ/dx (ionization charge per unit length) fitting, 3D neutrino vertex fitting, track and shower separation, particle-level clustering, and particle identification are then applied on these 3D space points as well as the original 2D projection measurements. A deep neural network is developed to enhance the reconstruction of the neutrino interaction vertex. Compared to traditional algorithms, the deep neural network boosts the vertex efficiency by a relative 30% for charged-current ν e interactions. Therefore, this pattern recognition achieves 80–90% reconstruction efficiencies for primary leptons, after a 65.8% (72.9%) vertex efficiency for charged-current ν e (ν μ ) interactions. Based on the resulting reconstructed particles and their kinematics, we also achieve 15-20% energy reconstruction resolutions for charged-current neutrino interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of Muon Neutrino Charged Current Single Neutral Pion Production on Argon with the MicroBooNE LArTPC

We report the first measurement of the absolute flux-integrated cross section of νµ charged current single π 0 6 production on argon. This measurement was performed with the MicroBooNE 7 detector, a liquid argon time projection chamber, utilizing neutrinos produced by the Fermilab 8 Booster Neutrino Beam. The analysis uses the first fully automated electromagnetic shower 9 reconstruction employed to analyze data from a liquid argon time projection chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-neutrino selection and reconstruction in the MicroBooNE LArTPC using the Pandora multi-algorithm pattern recognition

MicroBooNE (the Micro Booster Neutrino Experiment) is a liquid argon time-projection chamber experiment designed for short-baseline neutrino physics, currently running at Fermilab. It aims to address the anomalous excess of low-energy events observed by the MiniBooNE experiment. In this note we present a fully automated event selection algorithm to identify charged-current electron neutrino event candidates with no pions and at least one proton in the final state (ν e CC0π-Np). The efficiency of the current selection algorithm is (46.5±0.3) %. We also show some cuts on kinematic and geometric variables which reject background events. These cuts have been validated by analyzing two event samples orthogonal to our signal. Future improvements have been identified which will improve the reconstruction efficiency, especially at low energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗