Extraterrestrial life detection based on oxygen isotope exchange reactions.
Extraterrestrial life detection method based on catalysis of isotopic oxygen exchange between water and oxygen-containing anions
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Extraterrestrial life detection method based on catalysis of isotopic oxygen exchange between water and oxygen-containing anions
Pyrolysis gas chromatography method for life detection and chemical identification of microorganisms
Detector cell concept for signal response evaluation for culturable earth microorganisms including nutrient and environmental factors
The maximum likelihood procedure is developed for estimating the three spectral parameters of an assumed broken power law energy spectrum from simulated detector responses and their statistical properties investigated. The estimation procedure is then generalized for application to real cosmic-ray data. To illustrate the procedure and its utility, analytical methods were developed in conjunction with a Monte Carlo simulation to explore the combination of the expected cosmic-ray environment with a generic space-based detector and its planned life cycle, allowing us to explore various detector features and their subsequent influence on estimating the spectral parameters. This study permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.
Low energy proton damage effects on useful life of silicon surface barrier detectors operated in geomagnetically trapped radiation belts
The scientific throughput of a particular observing facility has been demonstrated to be multiplied with the operation of a data archive and its corresponding retrieval system. A requisite to achieve such an exploitation is a well structured observations catalog, i.e. a catalog that includes all information necessary to reduce and analyze the data even many years after its acquisition. At the same time, an information system is required that allow users to browse through the catalog at different levels of detail, adapting the amount of information presented to the actual needs of the user. Archiving data acquired with ground-based telescopes is particularly difficult because of the relative short life-time of instruments and detectors in comparison to the expected life-time of the archive. This feature differentiates ground-based originated archives radically from its spaceborne counterparts. The organization of the observations catalog becomes highly dependent on the capability of the archive to deal with new instrumental configurations. We introduce in this paper, the concept of a catalog database as opposed to the static catalog design currently in use in many archiving facilities, as a method to deal with this problem. We also present a brief review of activities currently in progress in this area.
The Nonscanning Climate Sensor represents a new instrument for climate research and global monitoring of the earth radiation budget. It contains a mosaic of array of detectors which measures the outgoing radiation of the earth in all directions without the need for mechanical scanning. The goal is to eliminate all moving parts and obtain highly calibrated measurements for up to one solar cycle (11 years) without being susceptible to mechanical failure. Over set intervals of time, the angular measurements are integrated up to produce total reflected and emitted flux values from each target area on the Earth. To achieve the require sensitivity while maintaining a flat spectral response, an improved dual cavity detector with digital control loop was developed. The detector is self calibrating to maintain high precision over the life of the instrument. Prototype detectors and a complete set of electronics with a microprocessor controller were fabricated and tested. Measurements show that the new detectors are more than an order of magnitude more sensitive than previous versions.
The MOD (Mars Organic Detector) instrument which has selected for the definition phase of the BEDS package on the 2005 Mars Explorer Program spacecraft is designed to simply detect the presence of amino acids in Martian surface samples at a sensitivity of a few parts per billion (ppb). An additional important aspect of amino acid analyses of Martian samples is identifying and quantifying which compounds are present, and also distinguishing those produced abiotically from those synthesized by either extinct or extant life. Amino acid homochirality provides an unambiguous way of distinguishing between abiotic vs. biotic origins. Proteins made up of mixed D- and L-amino acids would not likely have been efficient catalysts in early organisms because they could not fold into bioactive configurations such as the a-helix. However, enzymes made up of all D-amino acids function just as well as those made up of only L-amino acids, but the two enzymes use the opposite stereoisomeric substrates. There are no biochemical reasons why L-amino acids would be favored over Damino acids. On Earth, the use of only L-amino acids in proteins by life is probably simply a matter of chance. We assume that if proteins and enzymes were a component of extinct or extant life on Mars, then amino acid homochirality would have been a requirement. However, the possibility that Martian life was (or is) based on D-amino acids would be equal to that based on L-amino acids. The detection of a nonracemic mixture of amino acids in a Martian sample would be strong evidence for the presence of an extinct or extant biota on Mars. The finding of an excess of D-amino acids would provide irrefutable evidence of unique Martian life that could not have been derived from seeding the planet with terrestrial life (or the seeding of the Earth with Martian life). In contrast, the presence of racemic amino acids, along with non-protein amino acids such as alpha-aminoisobutyric acid and isovaline, would be indicative of an abiotic origin, although we have to consider the possibility that the racemic amino acids were generated from the racemization of biotically produced amino acids.
The method of Maximum Likelihood (ML) is used to estimate the spectral parameters of an assumed broken power law energy spectrum from simulated detector responses. This methodology, which requires the complete specificity of all cosmic-ray detector design parameters, is shown to provide approximately unbiased, minimum variance, and normally distributed spectra information for events detected by an instrument having a wide range of commonly used detector response functions. The ML procedure, coupled with the simulated performance of a proposed space-based detector and its planned life cycle, has proved to be of significant value in the design phase of a new science instrument. The procedure helped make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope. This ML methodology is then generalized to estimate broken power law spectral parameters from real cosmic-ray data sets.
Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.
This article provides an overview of several software control applications developed for NASA using LabVIEW. The applications covered here include (1) an Ultrasonic Measurement System for nondestructive evaluation of advanced structural materials, an Xray Spectral Mapping System for characterizing the quality and uniformity of developing photon detector materials, (2) a Life Testing System for these same materials, (3) and the instrument panel for an aircraft mounted Cloud Absorption Radiometer that measures the light scattered by clouds in multiple spectral bands. Many of the software interface concepts employed are explained. Panel layout and block diagram (code) strategies for each application are described. In particular, some of the more unique features of the applications' interfaces and source code are highlighted. This article assumes that the reader has a beginner-to-intermediate understanding of LabVIEW methods.
The fluence of high-LET particles (HLP) with LET infinity H2O greater than 15 keV micrometers-1 in selected organs and tissues were measured with plastic nuclear track detectors using a life-size human phantom on the 9th Shuttle-Mir Mission (STS-91). The planar-track fluence of HLP during the 9.8-day mission ranged from 1.9 x 10(3) n cm-2 (bladder) to 5.1 x 10(3) n cm-2 (brain) by a factor of 2.7. Based on these data, a probability of HLP hits to a matured cell of each organ or tissue was roughly estimated for a 90-day ISS mission. In the calculation, all cells were assumed to be spheres with a geometric cross-sectional area of 500 micrometers2 and the cell-hit frequency from isotropic space radiation can be described by the Poisson-distribution function. As results, the probability of one or more than 1 hit to a single cell by HLP for 90 days ranged from 17% to 38%; that of two or more than 2 hits was estimated to be 1.3-8.2%. c2002 COSPAR. Published by Elsevier Science Ltd. All rights reserved.
In the photo, Fire Chief Jay Stout of Safety Harbor, Florida, is explaining to young Richard Davis the workings of the Honeywell smoke and fire detector which probably saved Richard's life and that of his teen-age brother. Alerted by the detector's warning, the pair were able to escape their burning home. The detector in the Davis home was one of 1,500 installed in Safety Harbor residences in a cooperative program conducted by the city and Honeywell Inc.
The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.
The CloudSat spacecraft, scheduled for launch in 2004, will carry the 94 GHz Cloud Profiling Radar (CPR) instrument. The design, assembly and test of the flight Radio Frequency Electronics Subsystem (RFES) for this instrument has been completed and is presented here. The RFES consists of an Upconverter (which includes an Exciter and two Drive Amplifiers (DA's)), a Receiver, and a Transmitter Calibrator assembly. Some key performance parameters of the RFES are as follows: dual 100 mW pulse-modulated drive outputs at 94 GHz, overall Receiver noise figure < 5.0 dB, a highly stable W-band noise source to provide knowledge accuracy of Receiver gain of < 0.4 dB over the 2 year mission life, and a W-band peak power detector to monitor the transmitter output power to within 0.5 dB over life. Some recent monolithic microwave integrated circuit (MMIC) designs were utilized which implement the DA's in 0.1 micron GaAs high electron-mobility transistor (HEMT) technology and the Receiver low-noise amplifier (LNA) in 0.1 micron InP HEMT technology.
In this study, mathematical-based models for fatigue life were developed for Resistance Temperature Detectors (RTDs)/thermo-wells in high-pressure, cryogenic flow environments. A literature review that identified bench-scale stainless steel fatigue data at cryogenic temperatures that can be used to validate fatigue life mathematical models was pursued. Developing the ability to predict the fatigue life of RTDs/thermo-wells in high-pressure, cryogenic flow environments, especially liquid oxygen (LOX), will lead to a lower incidence of RTD damage and failure during propulsion test activities. During this performance period, the project was transitioned to a computational RTD/thermos-well fatigue modeling effort rather than the previously proposed experimental fatigue testing in FY19 since the computational modeling approach will provide a better fundamental understanding of fatigue behavior at cryogenic temperatures prior to pursuing potentially costly experimental tests. Due to COVID-19 issues impairing access to some needed university partnerships, tools and lab facilities, FY20efforts are continuing into FY21 and will be reported upon in greater detail in the FY21 report
The initial goal was to grow and characterize HgZnTe and determine if it indeed had the advantageous properties that were predicted. Researchers grew both bulk and liquid phase epitaxial HgZnTe. It was determined that HgZnTe had the following properties: (1) microhardness at least 50 percent greater than HgCdTe of equivalent bandgap; (2) Hg annealing rates of at least 2 to 4 times longer than HgCdTe; and (3) higher Hg vacancy formation energies. This early work did not focus on one specific composition (x-value) of HgZnTe since NASA was interested in HgZnTe's potential for a variety of applications. Since the beginning of 1989, researchers have been concentrating, however, on the liquid phase growth of very long wavelength infrared (VLWIR) HgZnTe (cutoff approx. equals 17 microns at 65K) to address the requirements of the Earth Observing System (EOS). Since there are no device models to predict the advantages in reliability one can gain with increased microhardness, surface stability, etc., one must fabricate HgZnTe detectors and assess their relative bake stability (accelerated life test behavior) compared with HgCdTe devices fabricated in the same manner. Researchers chose to fabricate HIT detectors as a development vehicle for this program because high performance in the VLWIR has been demonstrated with HgCdTe HIT detectors and the HgCdTe HIT process should be applicable to HgZnTe. HIT detectors have a significant advantage for satellite applications since these devices dissipate much less power than conventional photoconductors to achieve the same responsivity.