Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIFT FAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cold air performance of a tip turbine designed to drive a lift fan. 2: Partial admission

Partial admission performance was obtained for a 0.4 linear scale version of the LF460 lift fan turbine over a range of speed from 40 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratio from 2.2 to 5.0. The investigation was conducted in two parts, with each part using a different side of the turbine scroll to simulate loss of a gas generator. Each side had an arc of admission of 180. Results are presented in terms of specific work, torque, mass flow, and efficiency.

Haas, J. E.↗

Static performance of a 13.97 cm (5.5 inch) diameter model VTOL lift fan

A tip-turbine-driven fan of the type currently being used in wind tunnel tests of VTOL lift fan models was tested. Values of thrust, weight flow, exit total and static pressure, exit swirl angle, and turbine temperature drop were measured as a function of fan speed for several inlet and exit configurations. A standard fan performance map was also obtained.

Lowe, W. H.↗

Cold-air performance of a tip turbine designed to drive a lift fan. 3: Effect of simulated fan leakage on turbine performance

Performance data were obtained experimentally for a 0.4 linear scale version of the LF460 lift fan turbine for a range of scroll inlet total to diffuser exit static pressure ratios at design equivalent speed with simulated fan leakage air. Tests were conducted for full and partial admission operation with three separate combinations of rotor inlet and rotor exit leakage air. Data were compared to the results obtained from previous investigations in which no leakage air was present. Results are presented in terms of mass flow, torque, and efficiency.

Haas, J. E.↗

Labyrinth seal testing for lift fan engines

An abradable buffered labyrinth seal for the control of turbine gas path leakage in a tip-turbine driven lift fan was designed, tested, and analyzed. The seal configuration was not designed to operate in any specific location but was sized to be evaluated in an existing test rig. The final sealing diameter selected was 28 inches. Results of testing indicate that the flow equations predicted seal air flows consistent with measured values. Excellent sealing characteristics of the abradable coating on the stator land were demonstrated when a substantial seal penetration of .030 inch into the land surface was encountered without appreciable wear on the labyrinth knife edges.

Dobek, L. J.↗

Performance characteristics of a model VTOL lift fan in crossflow.

This paper presents a summary of principal results obtained from crossflow tests of a model 15-in.-diam lift fan installed in a wing in the NASA Lewis Research Center, 9 by 15 ft V/STOL Propulsion Wind Tunnel. Tests were run with and without exit louvers over a range of tunnel air speeds, fan speeds, and wing angle of attack. Fan thrust in crossflow was influenced by two principal factors: the effects of inflow distortion on blade-row performance, and changes in fan stage operating point brought about by changes in back pressure ratio. In this particular fan, flow separation on the inlet bellmouth did not appear to be a serious problem for crossflow operation.

Lieblein, S.↗

Cold-air performance of a tip turbine designed to drive a lift fan

Performance was obtained over a range of speeds and pressure ratios for a 0.4 linear scale version of the LF460 lift fan turbine with the rotor radial tip clearance reduced to about 2.5 percent of the rotor blade height. These tests covered a range of speeds from 60 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratios from 2.6 to 4.2. Results are presented in terms of equivalent mass flow, equivalent torque, equivalent specific work, and efficiency.

Haas, J. E.↗

Large-scale wind-tunnel investigation of a V/STOL transport model with podded lift fans forward and aft of a low mounted wing

A configuration with outboard pod mounted front fans and rear fans located in the wing trailing-edge and fuselage juncture might have superior induced lift and variation of moment with airspeed. A large scale investigation of this type of configuration was conducted in 40- by 80-foot wind tunnel. The model used was a low wing transport representative of currently operating aircraft. Two lift fans were placed in pods forward of and below the wing with the fan centerline near mid semi-span. Two rear fans were mounted at the wing trailing-edge close to the fuselage with the fan rotor in the wing chord plane. Fan performance was measured statically and with forward speed, and longitudinal aerodynamic characteristics were obtained with the fans operating at various tip-speed ratios.

Hall, L. P.↗

Aerodynamics model for a generic ASTOVL lift-fan aircraft

This report describes the aerodynamics model used in a simulation model of an advanced short takeoff and vertical landing (ASTOVL) lift-fan fighter aircraft. The simulation model was developed for use in piloted evaluations of transition and hover flight regimes, so that only low speed (M approximately 0.2) aerodynamics are included in the mathematical model. The aerodynamic model includes the power-off aerodynamic forces and moments and the propulsion system induced aerodynamic effects, including ground effects. The power-off aerodynamics data were generated using the U.S. Air Force Stability and Control Digital DATCOM program and a NASA Ames in-house graphics program called VORVIEW which allows the user to easily analyze arbitrary conceptual aircraft configurations using the VORLAX program. The jet-induced data were generated using the prediction methods of R. E. Kuhn et al., as referenced in this report.

Birckelbaw, Lourdes G.↗

Aerodynamic Characteristics of a Large-Scale Model with a High Disk-Loading Lifting Fan Mounted in the Fuselage

An investigation was conducted to determine the longitudinal characteristics during low-speed flight of a large-scale VTOL airplane model with a direct lifting fan enclosed in the fuselage. The model had a shoulder-mounted unswept wing of aspect ratio 5. The effect on longitudinal characteristics of fan operation, propulsion by means of deflecting the fan efflux, trailing-edge flap deflection, and horizontal-tail height were studied.

Aoyagi, Kiyoshi↗

Study of the application of an implicit model-following flight controller to lift-fan VTOL aircraft

An implicit model-following flight controller is proposed. This controller is relatively simple in concept: it provides an input/output relationship that is approximately that of any selected second order system; it provides good gust alleviation; and it is self-trimming. The flight controller was applied to all axes of a comprehensive mathematical model of a lift-fan V/STOL transport. Power management controls and displays were designed to match the various modes of control provided by the flight controller. A piloted simulation was performed using a six degree of freedom simulator. The fixed-operating-point handling qualities throughout the powered lift flight envelope received pilot ratings of 3-1/2 or better. Approaches and vertical landings in IFR zero-zero conditions received pilot ratings varying from 2-1/2 to 4 depending on the type of approach and weather conditions.

Merrick, V. K.↗

V/STOL lift fan commercial short haul transports: Continuing conceptual design study

A design study of commercial V/STOL transport airplanes for a 1985 operational time period has been made. The baseline mission considered was 400 nmi at a cruise speed of M = 0.75 and a 100-passenger payload with VTOL. Variations from the baseline included mission distance, payload, cruise speed, and propulsion system failure philosophy. All designs used propulsion systems consisting of multiple gas generators driving remote tip turbine lift and lift/cruise fans. By considering the fan to be designed for operational reliability, significant simplication of the airplane systems and reduction in airplane size and cost can be achieved.

Zabinsky, J. M.↗

Aerodynamic effects of five lift-fan pod arrangements on an unpowered V/STOL transport model

An investigation was conducted in the Langley V/STOL tunnel to determine the effect of longitudinally oriented wing-mounted pods on the longitudinal and lateral aerodynamic characteristics in the cruise flight condition of a high-wing V/STOL transport model. Five pod arrangements were tested - three configurations with in-line pods at 20, 40, or 60 percent semispan and two split pod configurations with rear pods at 20 percent semispan and front pods at 40 or 60 percent semispan. In general, addition of the pods to the model decreased the stability, increased the lift-curve slope, and alleviated the abrupt stall of the basic model. The configuration with pods at 20 percent semispan had an abrupt instability at 10 deg angle of attack, All the configurations had lateral stability at sideslip angles from 5 to -5 deg. Very little difference in results existed between the configurations with pods at 40 and 60 percent semispan. Of the split pod configurations, the configuration with front pods at 40 percent semispan offered the best trimmed lift and lift-induced drag characteristics at high angles of attack. The configuration with in-line pods at 40 or 60 percent semispan provided the best cruise characteristics of all the pod configurations.

Thomas, J. L.↗

Effect of crossflow velocity on the generation of lift fan jet noise in VTOL aircraft

Analytical studies based on a turbulent mixing noise prediction technique indicate that jet noise power levels are increased when a jet is situated in a crossflow. V/STOL model transport acoustic test data obtained in the NASA Ames 40 ft. x 80 ft. wind tunnel confirmed this jet noise power level increase due to crossflow. Increases up to 6 db at a Strouhal number of 2.5 and crossflow velocity to jet velocity ratio of 0.58 were observed. The power level increases observed in the experimental data confirm the predicted power level increases.

Stimpert, D. L.↗

Analytical Lift Fan Noise Study

Based on reasonable estimates of flow conditions occurring in an axial fan, acoustic radiation from various noise sources is evaluated. Results of computations on two specific fans are presented, and relative significance of the various sources is examined.

Rao, G. V. R.↗