Search NASA⌕ Search

SEARCH · Search NASA

Results for “LINER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

77 records · Page 5

Assessment of Vibration and Shock Loading Environments on Steels Used in Railroad Applications Considering Hydrogen Embrittlement

Studies that examine the combined effects of hydrogen and rail loading environments in the context of hydrogen embrittlement of steels have not been performed. Large-scale hydrogen storage requires either gaseous hydrogen stored in pressure vessels and tubing or liquid hydrogen in cryogenic, insulated tanks. Since the focus of this study is on steels, we examine the influence of hydrogen on stainless steel used for high pressure tubing and cryogenic tanks and Cr-Mo steel liners used in gaseous pressure vessels. Literature studies show that despite hydrogen degradation, these steels can be used effectively and safely if the stresses are managed. The shock and vibration environment on railcars present unique environments where stresses and loading rates can be high. A literature review was conducted to understand the accelerations experienced in rail by examining instrumented railcars of nuclear fuel casks. Hydrogen studies were examined that focused on steel pressure hardware with an emphasis on fatigue, fast loading rates, and low temperatures. A simplified fatigue assessment was performed to examine design cycles for three different hydrogen components: stainless steel tubing, stainless steel cryogenic tanks, and gaseous pressure vessels. The assessments were idealized and used bounding cases of accelerations in both normal rail conditions and coupling events. In normal shock and vibration environments when accelerations were less than 2 g, infinite design life was calculated. In extreme shock or coupling environments, finite design life was calculated which was shown to be dependent on unsupported lengths of pressure components. It was shown that adjusting the unsupported length can reduce the bending stress thereby increasing design life.

36 MATERIALS SCIENCE↗

Corrosion Testing of Refractory in Contact with Molten Glasses Designed for Waste Vitrification – VSL Touchpoint Matrix Glasses (Revision 1)

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF).[1] The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

The Intrinsic Sizes of Odd Radio Circles

Abstract A new class of sources, the so-called odd radio circles (ORCs), have been discovered by recent sensitive, large-area radio continuum surveys. The distances of these sources have so far relied on photometric redshifts of optical galaxies found at the centers of or near ORCs. Here we present Gemini rest-frame optical spectroscopy of six galaxies at the centers of, or potentially associated with, the first five ORC discoveries. We supplement this with Legacy Survey imaging and Prospector fits to theirgriz+W1/W2 photometry. Of the three ORCs with central galaxies, all lie at distances (z= 0.27–0.55) that confirm the large intrinsic diameters of the radio circles (300–500 kpc). The central galaxies are massive (M * ∼ 10 11 M ☉ ), red, unobscured ellipticals with old (≳1 Gyr) stellar populations. They have LINER spectral types that are shock-powered or active galactic nucleus (AGN)-powered. All three host low-luminosity, radio-quiet AGN. The similarity of their central galaxies is consistent with a common origin, perhaps as a blast wave from an ancient starburst. The other two ORCs are adjacent and have no prominent central galaxies. However, thez= 0.25 disk galaxy that lies between them hosts a Type 2, moderate-luminosity AGN. They may instead be the lobes of a radio jet from this AGN.

Astronomy & Astrophysics↗

SPC-70731 Rev 0 MARVEL Reactor Project ASME BPVC Section III Division 5 Design Specification

This specification establishes the requirements for the design of the MARVEL Primary Coolant System (PCS) Boundary, Guard Vessel System (GVS) Boundary, Core Support Structure (CSS), and Internal Heat Exchanger (IHX) Liner to provide a complete basis for ASME BPVC Section III Division 5 construction. All information in this section is generic and applicable to all metallic components unless otherwise specified.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗