Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOAD DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toucan: A performance portable, scalable implementation of the DECA algorithm

In the field of additive manufacturing (AM), cellular automata (CA) is extensively used to simulate microstructural evolution during solidification. However, while traditional CA approaches are relatively fast, they still require a substantial number of time steps, are limited to moderate volumes, and are relatively difficult to improve through parallelism due to the highly localized nature of the solidification front. Here, to address these issues of time to solution and load balancing, we introduce Toucan, a parallel, performance-portable, and scalable code written in C++ with the Kokkos library that leverages the discrete event inspired cellular automata (DECA) algorithm to perform parallel-in-time (PinT) grain growth simulations. Toucan effectively mitigates load balancing issues by distributing the computational workload more evenly across processors, enhancing scalability and efficiency. We conduct both strong and weak scaling studies on up to 64 GPUs on the Frontier supercomputer, demonstrating that Toucan significantly outperforms the current state-of-the-art, time-stepped CA code, ExaCA, on both single and multi-GPU simulations. Even in AM-specific weak scaling scenarios, Toucan maintains near-ideal scaling, in contrast to the linear increase observed with ExaCA due to the moving laser raster pattern. This study highlights Toucan’s potential to transform microstructural simulations in AM by radically improving both efficiency and scalability over existing methods.

36 MATERIALS SCIENCE↗

Study of eVTOL Charging Impact on Airport Electrical Grids

Growth in commercial air traffic has increased the aviation industry's contribution to global emissions. Aircraft electrification can reduce greenhouse gas emissions along with being efficient and reliable. Advanced air mobility introduces the idea of an advanced and more efficient air transportation system. Electric and hybrid aircraft designs, such as electric vertical takeoff and landing (eVTOL), are being considered for a number of applications, such as urban air mobility, cargo delivery, and medical emergencies. Although the electrification of aircraft provides environmental benefits, their charging needs will place significant demand on the electrical grid. This work presents a grid impact study and infrastructure upgrade requirements analysis of eVTOL charging on a realistic distribution grid through power flow simulation analysis. The case study results show that the eVTOL charging can lead to power quality issues, such as undervoltage and equipment capacity overloading. Grid infrastructure, such as lines and transformers, would need to be upgraded, and voltage management strategies would need to be deployed to accommodate eVTOL charging at an existing airport.

advanced air mobility (AAM)↗

CalTestBed - Lucent Optics (CRADA Final Report)

The CRADA partner was developing a window film aimed at improving the control of the solar radiation that arrives at a building’s windows, ultimately reducing cooling loads and improving the distribution of daylight. The efforts under this CRADA were aimed at better understanding the performance of one or more prototypes of this film, with the aim of helping to narrow down the film design parameters to values more likely to achieve better performance. The technical means of achieving this project’s goals used LBNL’s world-class test facilities and expertise. These technical means included: (a) measurements of the bidirectional scattering distribution function (BSDF) of film samples, and (b) full-scale measurement of the energy (HVAC, lighting) and comfort (visual, thermal) impacts of at least one film prototype, for two solar angle “seasons” (“high” and “low” solar angle).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status of the Fuel Fragment Dispersal Studies at Oak Ridge National Laboratory

During a loss-of-coolant accident, a nuclear fuel rods undergo balloon and burst. High burnup fuel is known to fragment and pulverize leading to the potential for the fuel to disperse through the burst opening either during the initial burst or following the burst during the reflood event. This milestone summarizes the design and assembly of a system to study dispersal in a postburst event. Surrogate fuel material (HfO2, tungsten, and yttria-stabilized zirconia [YSZ]) dispersing from as-burst loss-of-coolant accident (LOCA) test specimens was extensively investigated, along with dispersal of actual nuclear fuel following a LOCA Severe Accident Test Station (SATS) test. Surrogate material tests spanned a variety of burst geometries, particle types, particle size distributions, and rod oscillation loadings (frequency and amplitude combinations).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Size-Resolved Chemical Composition of Particles Collected Using STAC at the Ground Site During the SAIL Campaign in Gunnison, Colorado

Aerosol particles were collected using a four-stage Size and Time-resolved Aerosol Collector (STAC) during the SAIL field campaign. Each stage of STAC separates particles into distinct aerodynamic size fractions with 50% cut-off diameters: Stage A: 2.27 µm Stage B: 0.615 µm Stage C: 0.421 µm Stage D: 0.119 µm Each stage provides both size- and time-resolved sampling, enabling investigation of particle composition across different atmospheric regimes. Only a subset of samples was selected for analysis based on prevailing meteorological conditions (e.g., temperature, humidity, and air-mass influence) to capture representative aerosol types under distinct weather patterns. Collected substrates were first examined under Scanning Electron Microscopy (SEM) to evaluate particle loading, morphology, and spatial distribution. Subsequently, Computer-Controlled Scanning Electron Microscopy with Energy-Dispersive X-ray Spectroscopy (CCSEM/EDX) was performed to obtain size-resolved elemental composition of individual particles. A rule-based classification scheme was applied to categorize particles into major compositional groups (e.g., biological, carbonaceous, dust, sulfate, Na-rich, and mixed types). This dataset provides high-resolution morphological and chemical information on atmospheric particles collected during the SAIL campaign, offering insights into the influence of meteorology on aerosol composition and mixing state.

Size and Time-resolved Aerosol Collector↗

Scheduler Modeling of Distributed Energy Resources for Providing Ancillary Services

Distribution energy resources (DERs) have been integral components of modern power systems, and their capability to provide grid services has been widely studied. To promote the deployment of these resources in providing grid services in real-world utility operations, this paper proposes a day-ahead scheduler model for a distribution system connected DER plant. A certain amount of generation capacity of this DER plant is reserved for frequency services, and some ancillary services for the distribution system-including peak load reduction, voltage regulation, and power factor control-are integrated into the model. The model is tested on a real-world distribution system. From the simulation results, the energy and reserve schedule of the solar photovoltaic (PV) unit and battery energy storage system (BESS) can be determined, and voltage and power factor are well maintained. Additionally, in order to demonstrate the specific characteristics of the co-located and hybrid operation modes for the PV and BESS, these two modes are analyzed both theoretically and through real-time simulation. Simulation results show that most of PV's variability is transferred to the net power in the co-located mode, whereas it is transferred to the BESS in the hybrid mode. This proposed scheduler model and the comparison of co-located and hybrid modes can provide practical guidance for the applications of DER plant in the real-world utility.

14 SOLAR ENERGY↗

Cloud-based Testbed for Adaptive Under-Frequency Load Shedding with High DER Penetration

Increasing penetration of distributed energy resources and behind-the-meter renewables may soon disrupt the efficacy of critical protection schemes, such as under-frequency load shedding (UFLS). Improved data exchange and coordination across the transmission-distribution boundary will be required to maintain reliability of bulk electric system. Standards-based data integration platforms using agreed-upon semantic vocabularies, such as the Common Information Model, will be key to enabling adaptive protection schemes requiring synthesized data from both the bulk power system and behind-the-meter resources. This paper introduces a cloud-based open-source data integration environment and UFLS clustering algorithm being developed to enable adaptive relay coordination between transmission and distribution utilities in the state of Vermont.

Anderson, Alexander A.↗

Low-Jitter Clock Receivers for Fast Timing Applications

Precision timing is a key requirement for emerging 4D particle tracking, Positron Emission Tomography (PET), beam and fusion plasma diagnostics, and other systems. Time-to-Digital Converters (TDCs) are commonly used to provide digital estimates of the relative timing between events, but the jitter performance of a TDC can be no better than the performance of the circuits that acquire the pulses and deliver them to the TDC. Several clock receiver and distribution circuits were evaluated, and a differential amplifier with resistive loads driving a pseudo-differential clock distribution network, developed using design guidelines for radiation tolerance and cryogenic compatibility, was fabricated as part of three prototypes: an analog front-end testbed chip for high-precision timing pixel readout, a dedicated TDC evaluation chip, and a Low-Gain Avalanche Detector (LGAD) readout circuit. Based on TDC measurements of the prototypes, we infer that the jitter added by the clock receiver and distribution circuits is less than 2.25 ps-rms. This performance meets the requirements of many future precision timing systems. The clock receiver and on-chip pseudo-differential driver were fabricated in commercial 28-nm CMOS technology and occupy 2288 µm 2 .

47 OTHER INSTRUMENTATION↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Distribution Grid Model Publication Investigation

Interest in the external exchange of distribution grid model data is growing around the world, driven largely by the challenges and opportunities presented by the increasing amount of generation, storage, and flexible load being embedded within the distribution grid. This report provides an overview of the current state of distribution grid model data sharing, with a focus on the industry-leading activities currently underway in Great Britain (GB). A second report will explore opportunities for external distribution grid model sharing in the United States.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

High compressive energy absorption and shape recovery behavior of additively manufactured textile-inspired cylindrical braided metamaterials

Mechanical metamaterials (MMs) are engineered structures with unique mechanical properties that arise from their unique spatial arrangement or lattice-like structure. The most commonly designed MMs such as honeycomb and re-entrant auxetics are prone to failure at the sharp corners and weak joints due to the increased stress concentration under deformation. To mitigate this challenge, braided MM structures involving intertwining threads of nylon—forming curved unit cells—have been studied. These textile-inspired cylindrical braided metamaterials (CBMMs) with contrasting unit cells, namely diamond and regular CBMMs, were fabricated by 3D printing. The layer-by-layer deposited structure built by fused filament fabrication delivered an assembly of overlapped threads that are fused at the contact point. To understand deformation behavior of these MMs, finite element models were developed for various load scenarios including quasi-static compression, cyclic and creep loads at room temperature. Stress distribution, deformation mechanisms, and failure modes were analyzed and validated by experiments to analyze the geometries and associated performance. The diamond CBMMs showed stress softening at 30 % compressive strain, withstanding a load of ∼440 N, whereas the regular CBMMs at 50 % strain experienced ∼250 N. The diamond CBMMs delivered higher creep resistance under sustained load and better energy absorption under cyclic loading than the regular CBMMs. The latter, however, exhibited 94 % shape recovery in contrast to 88 % recovery in former prototype during their first cyclic load. In conclusion, this study helps design mechanical lightweight devices that endure significant sustained load and exhibit enhanced energy absorption and shape recovery characteristics in cyclic loading.

Creep↗

Least-cost Optimal Distribution Grid Expansion (LODGE): Utility Pilots

The Least-cost Optimal Distribution Grid Expansion (LODGE) model provides the optimal portfolio of distribution system upgrades—e.g., voltage regulators, feeder reconductoring, transformer upgrades and non-wires alternatives (NWA), such as strategic siting of storage and distributed generation—to interconnect distributed energy resources (DERs) and enable load growth. It can be used to assess grid infrastructure costs and explore policy and regulatory solutions for distribution planning and DER valuation.In 2025, Berkeley Lab conducted three pilot analyses to validate LODGE results with empirical utility data before the model’s first release in 2026. The pilots, done with utilities in Washington, Colorado, and New Mexico, provide examples that illustrate how the model works, what it can do, and the value of the analysis.

Heleno, Miguel↗

Controlling Air Conditioners for Frequency Regulation: A Real-World Example

Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. Here, we argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Distributed Frequency Regulation of Renewable Generators under Communication Interruptions

Modern power systems (MPSs) face significant challenges due to the high penetration of renewable energy sources (RESs) and new types of loads such as electric vehicles (EVs). Traditional load frequency control (LFC) methods struggle with the intermittent, stochastic nature of RESs, the near-zero inertia of power-electronics-based generators, and the mobility of controllable loads and battery systems. This paper introduces a novel resilient distributed frequency regulation method to address these issues. The proposed method employs a state space model to represent the dynamic behavior of participating power sources while accounting for stochastic switching processes to model structural and parameter variations caused by disruptions such as generator connection/disconnection, communication interruptions, and physical faults. By integrating these dynamic and stochastic components, the method treats power grids as a comprehensive stochastic hybrid system. Our method enhances conventional frequency control by incorporating local stability control, neighborhood control decoupling, and coordination feedback. Theoretical analyses establish the stability, convergence, and resilience of the proposed method, and its effectiveness is validated through case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Architecture for Web-Based Visualization of Large-Scale Energy Domains: Preprint

With the growing penetration of inverter-based distributed energy resources and increased loads through electrification, power systems analyses are becoming more important and more complex. Moreover, these analyses increasingly involve the combination of interconnected energy domains with data that are spatially and temporally increasing in scale by orders of magnitude, surpassing the capabilities of many existing analysis and decision-support systems. We present the architectural design, development, and application of a high-resolution web-based visualization environment capable of cross-domain analysis of tens of millions of energy assets, focusing on scalability and performance. Our system supports the exploration, navigation, and analysis of large data from diverse domains such as electrical transmission and distribution systems, mobility and electric vehicle charging networks, communications networks, cyber assets, and other supporting infrastructure. We evaluate this system across multiple use cases, describing the capabilities and limitations of a web-based approach for high-resolution energy system visualizations.

grid modernization↗