Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity-based voltage constraints for optimal power flow in low-voltage distribution feeders

The optimal power flow (OPF) problem for distribution systems can include network details down to the low-voltage (LV) points of interconnection of individual customers. This paper addresses the implementation of voltage magnitude constraints, and sets forth a practicable approach for capturing the effects on voltage from the switching behavior of loads (e.g., heat pumps, air conditioners, water heaters, or pool pumps) and from the variability of renewable generation (e.g., rooftop solar). The proposed method adjusts the OPF voltage constraints based on forecasts of load and generation upper and lower bounds, in conjunction with sensitivity factors derived from the power flow equations. An illustrative OPF formulation is also provided, which incorporates transformer models that include core loss. We demonstrate that accurate modeling of these LV network components is critical to avoid voltage violations at customer points of interconnection. Furthermore, the ideas are validated through numerical case studies on a realistic distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Van de Graaff Irradiation Studies of Oxygen Sensor and Hydrated Zirconia Sorbent

Commercial-scale production of Mo-99 demands a facility-wide assessment of radiation-induced degradation across process equipment, instrumentation, and purification media. Key factors— total ionizing dose, dose rate, radiolysis-driven chemistry, thermal loads, activation, and any neutron-related effects—should inform material selection, shielding, and component layout. Purification materials (sorbents, resins, filters, seals, housing) require particular attention to ensure that irradiation does not alter selectivity or capacity, generate fines, or introduce leachables that could compromise Mo-99 purity or downstream Tc-99m generator performance. Dose mapping, accelerated irradiation testing, and studies of extractables/leachables together provide the basis for setting maintenance, calibration, and replacement intervals and for qualifying materials that retain mechanical integrity, chemical compatibility, and radiopurity over their service life.

36 MATERIALS SCIENCE↗

Interaction of HOMs in periodic accelerating structures

The paper discusses the HOM interaction effect in a 5-cell 650 MHz HB cavity prototype for the PIP-II project. This effect may lead to flat HOM passbands. In the presence of misalignments, this passband disintegrates into individual cell resonances that are not coupled to the beam pipes and, therefore, have a high-quality factor and R/Q ratio. These resonances can lead to excessive cryogenic loading, increased emittance, and beam instabilities. An analytical theory has been developed to explain this effect, as well as special methods for eliminating it.

Yakovlev, V. [Fermilab]↗

Predicted Fracture Tendency of Naturally Occurring Aluminum Surface Coatings under Tensile Loading

Naturally occurring coatings on aluminum metal, such as its oxide or hydroxide, serve to protect the material from corrosion. Understanding the conditions under which these coatings mechanically fail is therefore expected to be an important aspect of predictive models for aluminum component lifetimes. To this end, we develop and apply a molecular dynamics (MD) modeling framework for conducting tension tests that is capable of isolating factors governing the mechanical strength as a function of coating chemistry, defect morphology, and variables associated with the loading path. We consider two representative materials, including γ-Al 2 O 3 and γ-Al(OH) 3 (i.e., oxide and hydroxide), both of which form readily as aluminum surface coatings. Our results indicate that defects have a significant bearing on the strength of aluminum oxide, with grain boundaries serving to reduce the strain at failure from ε zz = 0.300 to 0.219, relative to perfect single crystal. Our simulations also predict that porosity lowers the elastic stiffness and yield strength of the oxide. Relative to perfect crystal, we find porosity factors of 5%, 10% and 20% decrease the yield stress by 26%, 36% and 53%, respectively. MD predicts that perfect hydroxide and oxide single crystal have respective strains at failure of 0.08 and 0.31 under tensile uniaxial strain loading, and that the corresponding yield stresses are respectively 1.6 and 11.1 GPa. These data indicate that the hydroxide is substantially more susceptible to mechanical failure than the oxide. Our results, coupled with literature findings that indicate hot and humid conditions favor formation of hydroxide and defective oxide coatings, indicate the potential for a complicated dependence of aluminum corrosion susceptibility and stress corrosion cracking on aging history.

36 MATERIALS SCIENCE↗

Urban wash-off of tire wear particles

Tire wear particles (TWPs) are an important class of microplastics due to their toxicity and abundance. Because most TWPs are generated on impervious road surfaces, urban wash-off is the critical first phase of waterborne transport from their zone of production to stormwater drainage. However, little is known about the driving factors behind their mobilization. In this study, we use a rainfall simulator to investigate how surface roughness, rainfall intensity, and surface slope affect wash-off behaviors of TWPs. We also analyze how the size and shape of mobilized TWPs change over the course of simulated storm events. We found that low surface roughness, high rainfall intensity (most significant factor), and low slope result in the most rapid conveyance of TWP load. On average, large particles (>1000 µm) travelled faster than small particles (<125 µm). Particle shape explained a very small amount of variance in TWP wash-off velocity but was found to be more important under higher surface roughness conditions. In addition to wash-off velocity, we found similar conditions controlled the percent mobilization of TWPs. Low surface roughness and high rainfall intensity resulting in higher TWP wash-off rates is consistent with mineral sediment wash-off behavior. Conversely, low surface slope and large particle size leading to faster conveyance is directly opposed to mineral sediment wash-off. Our findings suggest drag-dominated flow and that sufficient runoff depth is the most important parameter governing TWP wash-off. These findings are important first steps to understanding wash-off behaviors of TWPs and informing future modeling efforts and mitigation strategies.

13 HYDRO ENERGY↗

Understanding early HIV-1 rebound dynamics following antiretroviral therapy interruption: The importance of effector cell expansion

Most people living with HIV-1 experience rapid viral rebound once antiretroviral therapy is interrupted; however, a small fraction remain in viral remission for an extended duration. Understanding the factors that determine whether viral rebound is likely after treatment interruption can enable the development of optimal treatment regimens and therapeutic interventions to potentially achieve a functional cure for HIV-1. We built upon the theoretical framework proposed by Conway and Perelson to construct dynamic models of virus-immune interactions to study factors that influence viral rebound dynamics. We evaluated these models using viral load data from 24 individuals following antiretroviral therapy interruption. The best-performing model accurately captures the heterogeneity of viral dynamics and highlights the importance of the effector cell expansion rate. Our results show that post-treatment controllers and non-controllers can be distinguished based on the effector cell expansion rate in our models. Furthermore, these results demonstrate the potential of using dynamic models incorporating an effector cell response to understand early viral rebound dynamics post-antiretroviral therapy interruption.

60 APPLIED LIFE SCIENCES↗

Studies of optical and chemical properties of aged and fresh biomass burning absorbing aerosols for climate models

Particulate emissions from burning fuels from sub-Saharan Africa is currently poorly characterized. With increasing population and industrialization, emissions are expected to grow. Optical methods for measuring light absorption in the ultraviolet (UV) and visible (vis) regions of the spectrum are crucial for understanding the optical properties of BB aerosols (Bond and Bergstrom, 2006; Lack and Cappa, 2010; Moschos et al., 2021). One such instrument is the dual-spot AE33 model aethalometer is a common filter-based instrument that can be used to measure aerosol absorption properties (Hansen et al., 1984). This instrument has many figures of merit; however, the method's limitations include potential biases from scattering within the filter material, multiple scattering effects of the particles, filter loading (i.e. particle shadowing), and the need for wavelength-specific correction factors (Cλ), which depend on accurate intercomparison with other in situ techniques (Bond et al., 1999; Collaud Coen et al., 2010). This work aims to: 1. Optically characterize BB aerosol generated from African fuel 2. Correct the aethalometer at multiple wavelengths 3. Parametrize these correction factors. 4. Combusting the same fuels with two difference tube furnace systems assess the general applicability of this flexible means of producing BB aerosol. This was accomplished by conducting laboratory studies at Los Alamos National Laboratory (LANL) and North Carolina A&T State University (NCA&T), where aethalometer measurements were compared to in situ optical measurements. Mass cross sections of BB aerosol from these under-studied fuels will be determined along with their wavelength dependence.

09 BIOMASS FUELS↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Assessing Geospatial and Seasonal Influences on Energy and Cost-Efficiency of Drayage Trucks

The electrification of heavy-duty vehicles is a critical pathway toward improved energy efficiency in the freight sector. The current battery electric truck technology poses several challenges to commercial vehicle operations, such as limited driving range, sensitivity to climate conditions, and long recharging times. Estimating the energy consumption of heavy-duty electric trucks is crucial to assessing the feasibility of fleet electrification and its impact on the electric grid. This article focuses on developing a model-based simulation approach to predict and analyze the energy consumption of electric trucks by considering the impact of weather and geographical conditions on vehicle road load and auxiliary components power consumption, as well as the impact these factors have on driving range. Specifically, drayage trucks employed in logistics around maritime ports are used as a case study, with consideration of seasonal climate variations and geographical characteristics at different locations. The article includes results for three major container ports within the United States, providing region-specific insights into the energy requirements and driving range of the electric drayage trucks in these regions, which will inform decision-makers in integrating electric trucks into the existing drayage operations and plan investments for electric grid development.

Sujan, Vivek [ORNL] (ORCID:0000000269882342)↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Self‐Standing Chiral Covalent Organic Framework Thin Films with Full‐Color Tunable Guest‐Induced Circularly Polarized Luminescence

Abstract Exploring self‐standing chiral covalent organic framework (COF) thin films with controllable circularly polarized luminescence (CPL) is of paramount significance but remains a challenging task. Herein, we demonstrate the first example of self‐standing chiral COF films employing a polymerization‐dispersion‐filtration strategy. Pristine, low‐quality chiral COF films were produced by interfacial polymerization and then re‐dispersed into COF colloidal solutions. Via vacuum assisted assembly, these COF colloids were densely stacked and assembled into self‐standing, pure chiral COF films ( L‐ / D‐ CCOF‐F) that were transparent, smooth, crack‐free and highly crystalline. These films were tunable in thicknesses, areas, and roughness, along with strong diffuse reflectance circular dichroism (DRCD) and cyan CPL signals, showing an intrinsic luminescence asymmetric factor ( g lum ) of ~4.3×10 −3 . Furthermore, these COF films served as host adsorbents to load various achiral organic dye guests through adsorption. The effective chiral transfer and energy transfer between CCOF‐F and achiral fluorescent dyes endowed the dyes with strong chirality and tunable DRCD, resulting in intense, full‐color‐tunable solid‐state CPL. Notably, the ordered arrangement of dye guest molecules within the preferentially oriented chiral pores of CCOF‐F contributed to an amplified | g lum | factor of up to 7.2×10 −2 , which is state‐of‐the‐art for COF‐based CPL materials. This work provides new insights into the design and fabrication of self‐standing chiral COF films, demonstrating their great potential for chiroptical applications.

Tang, Xihao↗

Direct ink writing of shear exfoliated two-dimensional nanomaterial- elastomeric multifunctional nanocomposite

Direct ink writing (DIW) of polymer nanocomposites with high loadings of two-dimensional (2D) nanofillers (graphene and hexagonal boron nitride (hBN)) is challenging because of potential clogging, use of hazardous solvents, and agglomeration. Here, in this work, a shear exfoliation and sieving method to prepare DIW ink with high loading of nanofillers produced from low-cost bulk layered materials such as graphite and bulk hBN powder for successful DIW printing without the use of any solvents, binders, or plasticizers. The single-step exfoliation technique resulted in a composite with substantial layer reduction along the c-axis, as confirmed by SEM, TEM, XRD, and Raman analysis. Incorporating exfoliated graphene (40 wt%) increased viscosity by ∼6 orders of magnitude due to enhanced particle–matrix interactions, leading to pronounced yield stress behavior and a yield stress of approximately 1598 Pa, which enabled excellent shape retention during extrusion. Using the DIW technique, porous structures such as desalination membranes, self-sensing bone scaffolds, thermal management coating, and serpentine strain sensors were fabricated. When tested in a direct contact membrane distillation setup, the fabricated membrane demonstrated a promising permeate flux of 21.85 Lm −2 h −1 and a salt rejection of 74.3 %. The fabricated serpentine sensor exhibited stable signal variations under cyclic tensile loading, with a working range of 0–200 % strain and a maximum gauge factor of 43,735. A cell culture test using the printed bone scaffold demonstrated promising cell attachment and proliferation. The DIW printed hBN nanocomposite exhibited reversible shape change under heat, demonstrating potential 4D printing capability and efficient thermal management when exposed to high heat or flame.

Desalination↗

Best Practices in Integrated Resource Planning: A guide for planners developing the electricity resource mix of the future

Most states today require regulated electric utilities to file an IRP every 1 to 5 years, and some utilities voluntarily prepare these plans. Planning needs have changed in recent years due to emerging load growth, plant retirements, rising costs, and more extreme weather events – among other factors. In response, Synapse Energy Economics and Lawrence Berkeley National Laboratory produced a joint report, Best Practices in Integrated Resource Planning: A guide for planners developing the electricity resource mix of the future. The guide offers best planning practices for electricity systems undergoing a major transition, but also contains a wealth of practical guidance to develop technically sophisticated, clearer, more effective, and state-of-the-art electric utility resource plans. The guide is for resource planning professionals and stakeholders involved in resource planning processes. This diverse group includes utility personnel tasked with conducting resource planning and making investment decisions, state regulatory commissions that develop planning guidance and oversee the resource planning process, and stakeholders that represent a wide range of interests—utility consumer advocates, environmental groups, industrial customers, local governments, independent power producers, and many other

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fitness-for-Service Analysis of Reactor Components under Flexible Load-Following Operating Conditions

Conventional power-generation plants, including nuclear plants, have been traditionally designed to provide a steady baseload energy capacity, optimizing output efficiency while minimizing variable costs. However, the growing adoption of large-scale renewable energy-generation systems, which rely on intermittent sources such as solar and wind, has introduced more variability into the energy supply in interconnected electricity grids. As a result, the next generation of power plants needs to operate in what is known as the load-following mode, requiring flexible adjustments in electricity production to align with the energy demand on the grid. This transition from the steady baseload operation to load-following operating conditions can significantly increase the number of times various plant components are exposed to transient stresses. This increased thermo-mechanical cycling can lead to accelerated material degradation, thereby elevating the risk of premature failure of a component. It becomes imperative to conduct a comprehensive analysis of fatigue, creep-fatigue, and stress corrosion cracking life, to assess the resilience of the various engineering components under these flexible load-following operating conditions. This study aims to develop a comprehensive numerical model of a light-water reactor pressure vessel (RPV) to investigate its degradation under various operating scenarios. This coupled thermo-mechanical finite element analysis evaluated the stress response of the RPV caused by considering fluctuations in thermal and mechanical loads caused by the varying pressure and temperature occurring during the load-following operation. Critical locations on the RPV are subsequently identified based on the stress response. The stress intensity factors for the postulated flaws at those locations are then calculated, followed by an evaluation of the reactor's life in accordance with the ASME Boiler and Pressure Vessel Code Section XI. This comprehensive life assessment covers a number of transients expected during the flexible load-following operation, providing invaluable insights into the RPV's structural integrity. Moreover, the development methodology can be adapted to other reactor components, as well as components of conventional power stations that are affected by varying operating conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Performance of Silicon Anodes through Hybrid Surface Engineering

Silicon (Si) is a promising anode material for nextgeneration lithium-ion batteries (LIBs) due to its high theoretical capacity. However, Si-containing anodes typically suffer from unacceptably short lives because of the unrestricted growth of the solid electrolyte interphase (SEI). Here, in this study, hybrid surface coatings are developed to stabilize the SEI in high loading pure Si anodes using atomic and molecular layer deposition. The coatings, consisting of LiF paired with lithicone, create an ionically conductive surface that enhances the capacity retention, rate performance, and longevity. Careful binder selection helps demonstrate the full utility of the coatings by enabling high loading electrodes to cycle continuously at current densities of 1200 mA/g Si . Uncoated controls, in comparison, fail within just 10 cycles at lower loadings. X-ray photoelectron spectroscopy and electrochemical impedance spectroscopy are used to provide supporting evidence of the coating composition and efficacy. The data indicate that our lithicone coating is converted to Li 2 CO 3 upon cycling contributing to favorable LiF/Li 2 CO 3 interfaces that enhance the space-charge effect at the active material’s surface. When applied to electrodes made with thermally stable binders and increasingly higher loadings (approaching 5 mAh/cm 2 ), ion transport through the bulk electrode, rather than SEI growth, is shown to be the limiting factor. Furthermore, data suggests a favorable interaction between lithicone precursors and poly(acrylic acid) binders mitigates thermal decomposition at higher temperatures. The work presented here represents the successful realization of composite coatings containing LiF/Li 2 CO 3 components to stabilize high-loading Si anodes. This work helps inform advanced surface engineering strategies to achieve highly reversible, high-capacity Si anodes capable of fast charging for high-performance LIBs.

atomic layer deposition↗

Cracked Gridline Wear Out Follows a Power Law

Cracks can form in Silicon solar cells in photovoltaic modules due to mechanical stresses arising from various extrinsic factors like handling and weather. While the immediate performance degradation may be minor, continuous loading overtime will degrade module performance. One probable reason is gridline surface wear across the cracked silicon with increased cyclic loading. In this work we propose a method to correlate gridline wear to module electrical degradation. We begin by conducting cyclic four-point bending tests on laminated silicon solar cells with a single crack and 22 intact gridlines for 10,000 cycles. We measure the progressive change in resistance during each loading cycle. We correlate it to a length scale called critical crack opening displacement (CCOD) that signifies failure of individual gridlines. By employing Weibull analysis, we determine the characteristic CCOD for all cycles and fit this data to a modified version of a wear power law. We observe that this i ts the data well. We also propose to study the effect of individual parameters in the power law equation and extend the equation to include material properties.

bending↗