At least 91 records · Page 5

Predicting radiative heat transfer in thermochemical nonequilibrium flow fields. Theory and user's manual for the LORAN code

The theory for radiation emission, absorption, and transfer in a thermochemical nonequilibrium flow is presented. The expressions developed reduce correctly to the limit at equilibrium. To implement the theory in a practical computer code, some approximations are used, particularly the smearing of molecular radiation. Details of these approximations are presented and helpful information is included concerning the use of the computer code. This user's manual should benefit both occasional users of the Langley Optimized Radiative Nonequilibrium (LORAN) code and those who wish to use it to experiment with improved models or properties.

Chambers, Lin Hartung↗

Comparison of upper tropospheric water vapor from GOES, Raman lidar, and Cross-chain Loran Atmospheric Sounding System measurements

Observations of upper tropospheric relative humidity obtained from Raman lidar and Cross-chain Loran Atmospheric Sounding System (CLASS) sonde instruments obtained during the First ISCCP Regional Experiment (FIRE) Cirrus-II field program are compared with satellite measurements from the GOES 6.7-micron channel. The 6.7-micron channel is sensitive to water vapor integrated over a broad layer in the upper troposphere (roughly 500-200 mbar). Instantaneous measurements of the upper tropospheric relative humidity from GOES are shown to agree to within roughly 6% of the nearest lidar observations and 9% of the nearest CLASS observations. The CLASS data exhibit a slight yet systematic dry bias in upper tropospheric humidity, a result which is consistent with previous radiosonde intercomparisons. Temporal stratification of the CLASS data indicates that the magnitude of the bias is dependent upon the time of day, suggesting a solar heating effect in the radiosonde sensor. Using CLASS profiles, the impact of vertical variability in relative humidity upon the GOES upper tropospheric humidity measurements is also examined. The upper tropospheric humidity inferred from the GOES 6.7-micron channel is demonstrated to agree to within roughly 5% of the relative humidity vertically averaged over the depth of atmosphere to which the 6.7-micron channel is sensitive. The results of this study encourage the use of satellite measurements in the 6.7-micron channel to quantitatively describe the distribution and temporal evolution of the upper tropospheric humidity field.

Soden, B. J.↗

Loran-C flight test software

The software package developed for the KIM-1 Micro-System and the Mini-L PLL receiver to simplify taking flight test data is described along with the address and data bus buffers used in the KIM-1 Micro-system. The interface hardware and timing are also presented to describe completely the software programs.

Nickum, J. D.↗

A Loran-C prototype navigation receiver for general aviation

Prototype equipment was developed for flight evaluation which provides enroute navigation in both latitude-longitude and rho-theta coordinates. The nonprecision approach capabilities of this equipment was evaluated. The antenna/preamplifier coupler, the RF processor, tracking loop hardware, tracking loop software, and the video output are discussed. Laboratory and flight test results are evaluated.

Lilley, R. W.↗

Probabilistic Modeling of Loran-C for nonprecision approaches

The overall idea of the research was to predict the errors to be encountered during an approach using available data from the U.S. Coast Guard and standard normal distribution probability analysis for a number of airports in the North East CONUS. The research consists of two parts: an analytical model that predicts the probability of an approach falling within a given standard, and a series of flight tests designed to test the validity of the model.

Einhorn, John K.↗

Enhanced character sizes for the VDM-1 video display board

Use of a microprocessor for providing navigation information from the inherent hyperbolic geometries of Loran-C was discussed. The advantages Loran-C offers over VOR/DME as a primary navigation aid are identified. These advantages include long range coverage by several stations, coverage at low altitudes, and the capability to have nonprecision approaches at airports not already served by landing aids. Modern digital electronic technology is used to produce a device to convert Loran-C data to useful pilot information using simple software algorithms and low cost microprocessor devices. The cost and lack of availability of suitable processors to execute these algorithms have prevented a Loran-C navigator from being developed. Results indicate that the microprocessor based Loran-C navigator has an accuracy of 1.0 nm or less over an area typically covered by a triad of Loran-C stations and can execute a position update in less than 0.2 seconds.

Novacki, S. M., III↗

Investigation of air transportation technology at Massachusetts Institute of Technology, 1984

Three projects sponsored by the Joint University Program at MIT are summarized. Two projects were focussed on the potential application of Loran-C in flying nonprecision approaches to general aviation runways, and the third project involved research on aircraft icing. In one Loran-C project, Aircraft Approach Guidance Using Relative Loran-C Navigation, the concept was flight tested. It used the difference in TD's from those of the touchdown point to simplify and speed navigation computer processing and took advantage of the short term accuracy of less than 100 feet for Loran-C. The goal of the project, Probabilistic Modelling of Loran-C Error for Nonprecision Approaches, was to develop a mathematical model which would predict the probability that an approach flown to a runway with a particular Loran-C receiver would fall within a given standard. The Aircraft Icing project focussed on measurement of droplet trajectories and droplet impingement/runback characteristics and measurement of real time ice accretion using ultrasonic pulse echo techniques.

Simpson, Robert W.↗

Experimental loop antennas for 60 KHz to 200 KHz

The design and design data for broadband loop antenna systems are presented. An investigation of some simple systems for possible Loran C receivers which require a bandwidth of greater than 20 KHz is discussed. Designs are presented for a 60 KHz WWVB antenna, several Loran C variations, and some 1750 meter band antennas. Signals received on all these, including one airborne experiment where a Loran C receiver gave the correct time difference reading within 1 microsecond while flying on a straightline course are examined. The phase reversal in the Loran C when the direction of travel changes 180 degrees is discussed and possible corrections are studied.

Burhans, R. W.↗

Commutated automatic gain control system

A commutated automatic gain control system (AGC) was designed and constructed for the prototype Loran C receiver. The AGC is designed to improve the signal-to-signal ratio of the received Loran signals. The AGC design does not require any analog to digital conversion and it utilizes commonly available components. The AGC consists of: (1) a circuit which samples the peak of the envelope of the Loran signal to obtain an AGC voltage for each of three Loran stations, (2) a dc gain circuit to control the overall gain of the AGC system, and (3) an AGC amplification of the input RF signal. The performance of the AGC system was observed in bench and flight tests; it has improved the overall accuracy of the receiver. Improvements in the accuracy of the time difference calculations to within approx. + or - 1.5 microseconds of the observed time differnces for a given position are reported.

Yost, S. R.↗

Investigation of air transportation technology at Ohio University, 1981

The increased availability of Loran signals in the United States encouraged consideration of Loran for airborne applications. High quality signal processing to obtain effective signal-to-noise ratios which permit good reliability in position determination consistent with airborne applications is considered. Techniques for deriving air navigation quality information from Loran-C were investigated.

Mcfarland, R. H.↗

RF front end interface and AGC modification

Preliminary results indicate that the new front end automatic gain control (AGC) combination perform satisfactorily. Side by side bench tests with Trimble 10A and Texas Instruments 9900 LORAN-C receivers have proven that the proper time differences are being obtained. Further optimization of the AGC circuit will occur as software to track all of the stations in a LORAN-C chain is developed. The AGC circuit was designed to sample up to six separate LORAN-C stations. Along with expanded station tracking software, a more sophisticated search routine is also under development. A printed circuit board for the AGC is planned and will be enclosed with the RF front end in a sealed enclosure to reduce interference from the other digital circuits of the microcomputer.

Yost, S. R.↗

Investigation of air transport technology at Massachusetts Institute of Technology, 1983

The limitations in providing both centerline and altitude guidance for runways in good Loran-C signal coverage were determined. The high data rate (10/sec) and good repeatable accuracy of Loran-C indicate that it will be possible to provide the pilot with continuous, cross pointer display of guidance information similar to that provided by ILS/MLS, at least when good signal-to-noise ratios and good geometry from Loran-C Lines of Position (LOP) exist at the airport.

Simpson, Robert W.↗

Low cost automated precise time measurement system

The Aerospace Guidance and Metrology Center (AGMC) has the responsibility for the dissemination of Precise Time and Time Interval (PTTI) to Air Force timing systems requiring microsecond time. In order to maintain traceability to the USNO Master Clock in Washington D.C., and accomplish efficient logging of time and frequency data on individual precision clocks, a simple automatic means of acquiring precise time has been devised. The Automatic Time Interval Measurement System (ATIMS) consists of a minicomputer (8K Memory), teletype terminal, electronic counter, Loran C receiver, time base generator and locally-manufactured relay matrix panel. During the measurement process, the computer controls the relay matrix which selects for comparison 13 atomic clocks against a reference clock and the reference versus Loran C. Through use of the system teletype, the operator is able to set the system clock (hours, minutes and seconds), examine and/or modify all clock data and constants, and set measurement intervals. This is done in a conversational manner. A logic flow diagram, system schematic, source listing and software components are included in the presentation.

Alpert, A.↗

An evaluation of differential Omega for general aviation area navigation

This paper reports on a study which compared the expected cost and performance of Differential Omega with that of Loran-C and VORTAC for general aviation area navigation. Analysis is directed toward a comparison of the systems with respect to specified performance parameters and the cost-effectiveness of each system in relation to the specifications. Loran-C offers the highest performance with respect to accuracy. Differential Omega requires the least expenditure. It was found cost ineffective to attempt to obtain complete coverage by expanding the existing VORTAC system.

Hollister, W. M.↗