Search NASA⌕ Search

SEARCH · Search NASA

Results for “LPM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Performance of pumped counterflow virtual impactors to study aerosol interactions with laboratory generated warm clouds

Pumped Counterflow Virtual Impactors (PCVI) are designed to separate aerosols based on aerodynamic diameter, which is particularly useful for isolating cloud droplets and ice crystals from smaller particles. However, the PCVI transmission efficiency (TE) values reported in the literature show considerable variability, and little information is available on the TEs for cloud liquid droplets. Here, we determined the optimal flow conditions for PCVI sampling for different activation ratios from the MTU Pi-cloud chamber, highlighting the conditions that maximize droplet residual sampling while minimizing interstitial transmission. Even for a lower limit cloud activation ratio = 1:10, an add flow of 1.5 LPM achieves a residual fraction greater than 0.80, with a droplet TE of ∼15% for typical Pi-Chamber droplets with diameters between 3.5 to 10 µm. This framework can be adapted for field cloud measurements based on the cloud conditions of interest. TE for cloud droplets under flow conditions at which ∼99% of the unactivated submicron particles were removed was substantially lower between 8 and 16% than for supermicron dry particles (∼30 to 40% for 3 µm polystyrene latex spheres). In addition, we conducted a comparison of the performances of three similar PCVI units to assess repeatability for dry aerosols and cloud droplets. All three PCVIs performed similarly in rejecting submicron particles smaller than the desired cutoff diameter. One of the units showed lower TEs due to a misalignment of the internal orifice. We discuss a procedure that improved alignment and performance.

54 ENVIRONMENTAL SCIENCES↗

Computational Fluid Dynamics Analysis of the Molten Salt Tritium Transport Experiment Test Section

Tritium, a radionuclide produced through neutron capture by lithium and other elements (beryllium and fluoride) in molten salts, presents unique challenges to radionuclide release. This is true for both fusion energy breeder blankets and molten salt fission reactors. The fundamental understanding of tritium transport is crucial to the safe design and operation of these reactors. The Molten Salt Tritium Transport Experiment (MSTTE), currently under construction at Idaho National Laboratory, aims to investigate tritium transport phenomena using a forced-convection fluoride salt loop. This loop is designed to study various transport mechanisms, such as permeation through metals and gas-liquid interactions, and is intended to support future research on tritium extraction units. A critical aspect of the MSTTE loop design is ensuring a fully developed velocity profile before the fluid reaches the permeation test section where measurements are made. This study employs computational fluid dynamics to model the salt flow behavior within the MSTTE permeation test section. A realizable k-ε turbulent model with enhanced wall treatment is used to simulate the single-phase, vertical upward flow of molten salt FLiNaK under isothermal conditions. The simulation results indicated flow distortion and underdeveloped profiles at all planned flow rates within the test section due to the 85-deg sharp bend. To address this issue, a reduced diameter with a reducer and expander and a flow conditioner are investigated to achieve fully developed flow. The analysis showed that the flow conditioner successfully corrected the flow profile, achieving fully developed behavior at a flow rate of 50 liters per minute (LPM). In conclusion, this research enhances our understanding of flow dynamics in molten salt systems and contributes to optimizing tritium transport control technologies.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photon bremsstrahlung and diffusive broadening of a hard jet

The photon bremsstrahlung rate from a quark jet produced in deep-inelastic scattering (DIS) off a large nucleus is studied in the collinear limit. The leading medium-enhanced higher twist corrections that describe the multiple scattering of the jet in the nucleus are re-summed to all orders of twist. The propagation of the jet in the absence of further radiative energy loss is shown to be governed by a transverse momentum diffusion equation. We compute the final photon spectrum in the limit of soft photons, taking into account the leading and next-to-leading terms in the photon momentum fraction y. In this limit, the photon spectrum in a physical gauge is shown to arise from two interfering sources: one where the initial hard scattering produces an off-shell quark, which immediately radiates the photon and then undergoes subsequent soft rescattering, and an alternative in which the quark is produced on-shell and propagates through the medium until it is driven off-shell by rescattering and radiates the photon. Our result has a simple formal structure as a product of the photon splitting function, the quark transverse momentum distribution coming from a diffusion equation, and a dimensionless factor that encodes the effect of the interferences encountered by the propagating quark over the length of the medium. The destructive nature of such interferences in the small-y limit is responsible for the origin of the Landau-Pomeranchuck-Migdal (LPM) effect. Along the way we also discuss possible implications for quark jets in hot nuclear matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Drag of heavy quarks in quark gluon plasma at energies available at the CERN Large Hadron Collider (LHC)

The drag and diffusion coefficients of charm and bottom quarks propagating through quark gluon plasma (QGP) have been evaluated for conditions relevant to nuclear collisions at the Large Hadron Collider (LHC). The dead cone and Landau-Pomeronchuk-Migdal (LPM) effects on radiative energy loss of heavy quarks have been considered. Both radiative and collisional processes of energy loss are included in the effective drag and diffusion coefficients. With these effective transport coefficients, we solve the Fokker-Plank (FP) equation for the heavy quarks executing Brownian motion in the QGP. The solution of the FP equation has been used to evaluate the nuclear suppression factor, R{sub AA}, for the nonphotonic single-electron spectra resulting from the semileptonic decays of hadrons containing charm and bottom quarks. The effects of mass on R{sub AA} have also been highlighted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy loss in a partonic transport model including bremsstrahlung processes

A detailed investigation of the energy loss of gluons that traverse a thermal gluonic medium simulated within the perturbative QCD-based transport model BAMPS (a Boltzmann approach to multiparton scatterings) is presented in the first part of this work. For simplicity the medium response is neglected in these calculations. The energy loss from purely elastic interactions is compared with the case where radiative processes are consistently included based on the matrix element by Gunion and Bertsch. From this comparison, gluon multiplication processes gg{yields}ggg are found to be the dominant source of energy loss within the approach employed here. The consequences for the quenching of gluons with high transverse momentum in fully dynamic simulations of Au+Au collisions at the BNL Relativistic Heavy Ion Collider (RHIC) energy of {radical}(s)=200A GeV are discussed in the second major part of this work. The results for central collisions as discussed in a previous publication are revisited, and first results on the nuclear modification factor R{sub AA} for noncentral Au+Au collisions are presented. They show a decreased quenching compared to central collisions while retaining the same shape. The investigation of the elliptic flow v{sub 2} is extended up to nonthermal transverse momenta of 10 GeV, exhibiting a maximum v{sub 2} at roughly 4 to 5 GeV and a subsequent decrease. Finally the sensitivity of the aforementioned results on the specific implementation of the effective modeling of the Landau-Pomeranchuk-Migdal (LPM) effect via a formation-time-based cutoff is explored.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lattice QCD estimates of thermal photon production from the QGP

Thermal photons produced in heavy-ion collision experiments are an important observable for understanding quark-gluon plasma (QGP). The thermal photon rate from the QGP at a given temperature can be calculated from the spectral function of the vector current correlator. Extraction of the spectral function from the lattice correlator is known to be an ill-conditioned problem, as there is no unique solution for a spectral function for a given lattice correlator with statistical errors. The vector current correlator, on the other hand, receives a large ultraviolet contribution from the vacuum, which makes the extraction of the thermal photon rate difficult from this channel. We therefore consider the difference between the transverse and longitudinal part of the spectral function, only capturing the thermal contribution to the current correlator, simplifying the reconstruction significantly. The lattice correlator is calculated for light quarks in quenched QCD at T = 470 MeV ( ∼ 1.5 T c ), as well as in 2 + 1 flavor QCD at T = 220 MeV ( ∼ 1.2 T p c ) with m π = 320 MeV . In order to quantify the nonperturbative effects, the lattice correlator is compared with the corresponding NLO + LPM LO estimate of correlator. The reconstruction of the spectral function is performed in several different frameworks, ranging from physics-informed models of the spectral function to more general models in the Backus-Gilbert method and Gaussian process regression. We find that the resulting photon rates agree within errors. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

High Temperature Sodium Submersible Flowmeter Design and Analysis

This work details the design and analysis of a permanent magnet flowmeter designed to be submerged in a pool type sodium fast reactor environment. Recently developed Samarium Cobalt rare earth magnets were utilized that have demonstrated resilience to temperature and neutron flux up to 550 °C and 10 18 n/cm 2 , respectively. This paper will discuss the theory, design, calibration and uncertainty quantification of the flowmeter. The flowmeter was calibrated over a flowrate range of 11.4 - 90.9 LPM at temperatures of 220 and 400 °C, yielding an uncertainty in calibration of 2-3.6%. Here, a finite element model was developed and validated experimentally, yielding <; 3.2% error.

47 OTHER INSTRUMENTATION↗

River-Induced Flow Dynamics in Long-Screen Wells and Impact on Aqueous Samples

Previously published field investigations and modeling studies have demonstrated the potential for sample bias associated with vertical wellbore flow in conventional monitoring wells constructed with long-screened intervals. This paper builds on the existing body of literature by 1) demonstrating the utility of continuous (i.e., hourly measurements for ~ one month) ambient wellbore flow monitoring and 2) presenting results from a field experiment where relatively large wellbore flows (up to 4 LPM) were induced by aquifer hydrodynamics associated with a fluctuating river boundary located approximately 250 m from the test well. The observed vertical wellbore flows were strongly correlated with fluctuations in river stage, alternating between upward and downward flow throughout the monitoring period in response to changes in river stage. Continuous monitoring of ambient wellbore flows using an Electromagnetic Borehole Flowmeter (EBF) allowed these effects to be evaluated in concert with continuously monitored river-stage elevations (hourly) and aqueous uranium concentrations (daily) in a long-screen well and an adjacent multi-level well cluster. This study demonstrates that when contaminant concentrations within the aquifer vary significantly over the depth interval interrogated, even for screen lengths as small as 7.6 m, river-induced vertical wellbore flow can result in variations in measured concentration that nearly encompass the full range of variation in aquifer contaminant concentration with depth. An approach to mitigate these effects based on increasing hydraulic resistance within the wellbore by installing an inflatable packer was evaluated and was demonstrated to reduce vertical wellbore flows.

54 ENVIRONMENTAL SCIENCES↗

Photon emission from bare quark stars

We investigate the photon emission from the electrosphere of a quark star. We show that at temperatures T Almost-Equal-To 0.1-1 MeV, the dominating mechanism is the bremsstrahlung due to bending of electron trajectories in the mean Coulomb field of the electrosphere. The radiated energy for this mechanism is much larger than that for the Bethe-Heitler bremsstrahlung. The energy flux from the mean field bremsstrahlung also exceeds the one from the tunnel e{sup +}e{sup -} pair creation. We demonstrate that the LPM suppression of the photon emission is negligible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A simple novel device for air sampling by electrokinetic capture

A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

47 OTHER INSTRUMENTATION↗

Condensation Particle Counter (CPC) Instrument Handbook

The Model 3772 CPC is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high concentration measurements, such as basic aerosol research, filter and air-cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Condensation Particle Counter (CPC) Instrument Handbook - Airborne Version

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Model 3772 condensation particle counter (CPC) is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high-concentration measurements, such as basic aerosol research, filter and air cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.

54 ENVIRONMENTAL SCIENCES↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation Testing of Hydrogen Generation Technology

This report describes the results of testing performed by ORNL for Photech Energies, Inc. The objective of the testing was to evaluate the efficacy of Photech's hydrogen generation reactor technology, which produces gaseous hydrogen through electrolysis. Photech provided several prototypes of their proprietary reactor for testing and the ancillary equipment, such as power supplies and electrolyte solutions, required for proper operation of the reactors. ORNL measured the production of hydrogen gas (volumetric flow of hydrogen at atmospheric pressure) as a function of input power and analyzed the composition of the output stream to determine the purity of the hydrogen content. ORNL attempted measurements on two basic versions of the prototype reactors-one version had a clear plastic outer cylinder, while another version had a stainless steel outer cylinder-but was only able to complete measurements on reactors in the plastic version. The problem observed in the stainless steel reactors was that in these reactors most of the hydrogen was produced near the anodes along with oxygen and the mixed gases made it impossible to determine the amount of hydrogen produced. In the plastic reactors the production of hydrogen gas increased monotonically with input power, and the flow rates increased faster at low input powers than they did at higher input powers. The maximum flow rate from the cathode port measured during the tests was 0.85 LPM at an input power of about 1100 W, an electrolyte concentration of 20%. The composition of the flow from the cathode port was primarily hydrogen and water vapor, with some oxygen and trace amounts of carbon dioxide. An operational mode that occurs briefly during certain operating conditions, and is characterized by flashes of light and violent bubbling near the cathode, might be attributable to the combustion of hydrogen and oxygen in the electrolyte solution.

08 HYDROGEN↗

CPC_ACEENA

The condensation particle counter (CPC 3772 or 3010, TSI) measures the number concentration of aerosols from 10 nm to 3 microns. On the G1, it was operated using an external pump and maintained at 1 LPM using a critical orifice. CPC_CVI was installed after CVI inlet, and CVI inlet was operated between two modes: under-kinetic mode and CVI mode. CPC_Isok (3772) and CPC3025 were installed after iso-kinetic inlet and CPC_TD was after the thermal denuder (TD). The infomation about the TD can be found from FIMS dataset.

54 ENVIRONMENTAL SCIENCES↗

Size_resolved_ice_nucleating_particle_INP_concentrations_from_the_INPOP_campaign

Ground-based immersion mode ice nucleation measurements were conducted on samples collected at the US DOE ARM AMF3 in Oliktok Point, AK from 1 Mar to 31 May 2017. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D, had particle size cuts at 2.96, 1.21, 0.34, and 0.15 &micro;m in particle diameter. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank is created on the PFA to separate daily samples. The pump typically pulled 25 lpm at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 36,000 total L of air per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and changed to a new disc. Discs were stored frozen after collection. Following collection and transport from AMF3 to PI Creamean's laboratory in Boulder, CO, strips were removed from the discs and cut up to separate daily samples. Each daily portion of the strip was stored in separate sterile bags and stored in a standard commercial freezer until analysis (approximately 4 &ndash; 5 months after collection). Drop freezing assays (DFAs) were conducted on one daily sample per week of the study for all four stages, with daily samples analyzed from 22 - 29 May 2017. Immediately after removal from the freezer, 2 mL of ultrapure water was added with a single-use sterile syringe directly to the bags, then mixed using a vortex mixer for 2 hours at 500 rpm to resuspend particles from the PFA into the ultrapure water. Following sample preparation, another single-use syringe was used to create 100 aliquots on a 3-inch diameter copper plate, then covered with a transparent plastic dome. The drops were approximately the same volume (2.5 &micro;L each), though careful inspection. The plate was cooled at approximately 3 &ndash; 10 K min-1 from room temperature until all drops froze on the plate. Temperature was measured by an Omega thermocouple probes and meter. Drop freezing was visually detected, but recorded through monitoring software to provide the time frozen, channel of the meter used, temperature, and cooling rate for each drop. Not all 100 drops were always detected; the total number of rows in each data file equals the number of drops recorded, which typically was > 80 %. Each sample was tested three times (i.e., a new set of 100 drops was created for each test). Data provided are files containing these parameters. From the freezing temperatures recorded, the fraction frozen can be calculated as can the estimated INP concentration per L of air using the equation from Vali (1971): [INPs] = &minus;(ln(f)/Valiquot)*(Vsuspension/Vair) where f is the proportion of droplets not frozen, Valiquot is the volume of each aliquot (i.e., 2.5e-6 L), Vsuspension is the volume of the suspension (i.e., 0.002 L), and Vair is the volume of air per sample (i.e., 36000 L). Vali, G.: Quantitative Evaluation of Experimental Results an the Heterogeneous Freezing Nucleation of Supercooled Liquids, Journal of the Atmospheric Sciences, 28, 402-409, 1971.

4-stage DRUM aerosol collector (DA400),Aerosol imp↗

TAP Absorption Coefficients

The data set of aerosol light absorption coefficients were collected by two tricolor absorption photometers (TAP; Brechtel Model 2901) in July and August, 2022 during the TRACER field campaign at the AMF1 site in La Porte, Texas. One of the TAPs at the La Porte site was an RGB model measuring aerosol light absorption at 652, 528, 467 nm, and the other was an UV model measuring absorption at the same red and green wavelengths but at an additional UV wavelength at 365 nm. Since TAP is a filter-based optical instrument using 47-mm glass fiber filters, the output absorption coefficients are corrected for filter loading and scattering effects based on a correction scheme developed in "Comment on ‘Calibration and Intercomparison of Filter-Based Measurements of Visible Light Absorption by Aerosols’" by John A. Ogren 2010. This uploaded dataset contains both the Ogren corrected absorption coefficients (column header with “ Ogren”) and the raw absorption coefficients without the correction scheme (column header with “_ Raw”). During the field campaign, the two TAPs operated side by side with a shared inlet at a flow rate of 2 lpm. In July, no inlet impactors/cyclones were installed; however, beginning in August, a PM2.5 cyclone inlet was installed.

54 ENVIRONMENTAL SCIENCES↗

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗