Search NASA⌕ Search

SEARCH · Search NASA

Results for “Langmuir Probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Fixed-Bias Langmuir Probe on the Communication-Navigation Outage Forecast System Satellite: Calibration and Validation

A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasma density is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future fixed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.

Vector Electric Field Instrument↗

Solar EUV index for aeronomical studies at earth from Langmuir probe photoelectron measurements on the Pioneer Venus orbiter

A solar EUV index for aeronomical studies at earth, obtained from the Langmuir probe measurement of photoelectron current on the Pioneer Venus orbiter, is presented. To examine the potential of E sub EUV as a solar EUV flux index, the behavior of ionospheric parameters f sub 0 E, f sub 0 F1, and f sub 0 F2 are studied at midlatitude stations, and their relationship with E sub EUV and with the 10.7-cm solar radio flux is compared. f sub 0 F1 and f sub 0 F2 are found to be better correlated with E sub EUV than with the 10.7-cm flux. F sub 0 E is better correlated with the 10.7-cm flux, because the 10.7-cm flux is also a proxy for soft X-rays, which are an important ionizing source in the E region. A table is also presented for the EUV index, E sub EUV, for the period February 12, 1979, through most of 1991.

Hoegy, W. R.↗

Soft Particle Spectrometer, Langmuir Probe, and Data Analysis for Aerospace Magnetospheric/Thermospheric Coupling Rocket Program

Under this grant two instruments, a soft particle spectrometer and a Langmuir probe, were refurbished and calibrated, and flown on three instrumented rocket payloads as part of the Magnetosphere/Thermosphere Coupling program. The flights took place at the Poker Flat Research Range on February 12, 1994 (T(sub o) = 1316:00 UT), February 2, 1995 (T(sub o) = 1527:20 UT), and November 27, 1995 (T(sub o) = 0807:24 UT). In this report the observations of the particle instrumentation flown on all three of the flights are described, and brief descriptions of relevant geophysical activity for each flight are provided. Calibrations of the particle instrumentation for all ARIA flights are also provided.

Sharber, J. R.↗

Temporal study of the current collected by a Langmuir probe biased to high voltages in the wake behind a conducting body

The temporal evolution of the voltage-current characteristic of a spherical Langmuir probe in the near-wake region of a conducting body is investigated in a pulsed plasma device. Measurements of the current collected by a sphere placed on axis behind a conducting disk are presented as a function of the bias voltage and time. The bias voltage on the collecting sphere is large enough, ranging from +500 to -3000 V, to attract ions or electrons across the wake region. In addition, plasma potential profiles as a function of sphere bias voltage and time throughout the nearwake and midwake region are presented. It is found that for a negative sphere bias a threshold voltage exists for current collection. This threshold voltage decreases during the formation of the wake behind the conducting disk. Potential measurements indicate that the sheath region around the negatively biased sphere contracts as the wake region establishes itself. This contraction of the sheath region increases the electric field attracting ions to the sphere and decreases the threshold voltage for current collection. For positive sphere bias voltage the current collected by the sphere does not exhibit a threshold voltage but is monotonically increasing.

Meassick, S.↗

Langmuir Probe Measurements of Inductively Coupled Plasmas in CF4/Ar/O2 Mixtures

Fluorocarbon gases, such as CF4, and their mixtures are widely used in contemporary low-pressure and high-density plasma processing techniques. In such plasmas Langmuir probe is one of the most commonly employed diagnostic techniques to obtain electron number density (ne), electron temperature (Te), electron energy distribution function (EEDF), mean electron energy (Ee), ion number density (ni), and plasma potential (Vp). In this paper we report probe data for planar inductively coupled plasmas in CF4/O2/Ar mixtures. By varying the relative concentrations in the mixture, radial profiles of ne, ni, Te, Ee, Vp, EEDF were measured in the mid-plane of the plasma at 10 mTorr and 20 mTorr of gas pressures, and 200 W and 300 W of RF powers. Data show that ne and ni decrease with increase of CF4 content and decrease of gas-pressure but they increase with increase of RF-power, whereas Vp increases with decrease of gas-pressure and remains independent of RF-power. However, they all peak at the center of the plasma and decrease towards the edge while Te follows the other way and increases a little with increase of power. The measured EEDFs exhibit Druyvesteyn-like distribution at all pressures and powers. Data are analyzed and will be presented.

Rao, M. V. V. S.↗

Langmuir Probe Measurements of Inductively Coupled CHF3/Ar and Ar/CHF3/O2 Plasmas

Plasma parameters, such as, electron number density (ne), electron temperature (Te), y electron energy distribution function (EEDF), mean electron energy (Ee), ion number density (ni), and plasma potential (Vp), have been measured by using Langmuir probe in low-pressure (10-50 mTorr) inductively coupled CHF3/Ar and CHF3/Ar/O2 plasmas generated in the GEC cell. The measurements were made at the center of the plasma, keeping the lower electrode grounded, for various CHF3/Ar and Ar/CHF3/O2 mixtures operating at 10-50 mTorr pressures and two input RF power levels, 200 and 300 W. EEDF data show a strong Druyvesteyn distribution with relatively lower number of low energy electrons as compared to a Maxwell distribution and a large electron population with energies higher than the plasma potential. The results further show that at low CHF3 concentrations (less than 50%) the electron number density remains nearly constant with increase in pressure. At higher CHF3 concentrations, however, it decreases with increase in pressure. Plasma potential and electron temperature increase with decrease in pressure and with increase in CHF3 concentration. An analysis of the above observations and mechanisms will be presented.

Sharma, S. P.↗

Magnetic and Langmuir Probe Measurements on the Plasmoid Thruster Experiment (PTX)

The Plasmoid Thruster Experiment (PTX) operates by inductively producing plasmoids in a conical theta-pinch coil and subsequently ejecting them at high velocity. An overview of PTX is described in a companion paper. The shape and magnetic field structure of the translating plasmoids will be measured with of an array of inductive magnetic field probes. Six sets of two B-dot probes (for a total of twelve probes) have been constructed for measuring B(sub z) and B(sub theta), the axial and azimuthal components of the magnetic field. The probes were calibrated with a Helmholtz coil, driven alternately by a high-voltage pulser or a signal generator. The probes are wound on a G-10 form, and have an average (calibrated) NA of 9.37 x 10(exp -5) square meters, where N is the number of turns and A is cross-sectional area. The frequency response of the probes was measured over the range from 1 kHz to 10 MHZ. The electron number density n(sub e), electron temperature T(sub e) and velocity v will be determined from measurements taken with a quadruple Langmuir probe, situated in the exhaust chamber. Three of the four probes on the quadruple probe sample the current-voltage characteristic, and from this yield measurements of T(sub e) and n(sub e). The fourth probe provides a measurement of plasma flow velocity. A 6-inch long alumina rod, hollowed with four holes to house the probe wires, is being used to construct the quadruple probe. A variety of propellants will be used, including hydrogen, nitrogen and argon. From the measurements of the plasmoid mass, density, temperature, and velocity, the basic propulsion characteristics of PTX will be evaluated.

Koelfgen, Syri J.↗

Langmuir Probe Measurements in an Inductively Coupled Ar/CF4 Plasmas

Technological advancement in the microelectronics industry requires an understanding of the physical and chemical processes occurring in plasmas of fluorocarbon gases, such as carbon tetrafluoride (CF4) which is commonly used as an etchant, and their mixtures to optimize various operating parameters. In this paper we report data on electron number density (ne), electron temperature'(Te), electron energy distribution function (EEDF), mean electron energy, ion number density (ni), and plasma potential (Vp) measured by using Langmuir probe in an inductively coupled 13.56 MHz radio frequency plasmas generated in 50%Ar:50%CF4 mixture in the GEC cell. The probe data were recorded at various radial positions providing radial profiles of these plasma parameters at 10-50 mTorr pressures and 200 W and 300 W of RF power. Present measurements indicate that the electron and ion number densities increase with increase in pressure and power. Whereas the plasma potential and electron temperature decrease with increase in pressure, and they weakly depend on RF power. The radial profiles exhibit that the electron and ion number densities and the plasma potential peak at the center of the plasma with an exponential fall away from it, while the electron temperature has a minimum at the center and it increases steadily towards the electrode edge. The EEDFs have a characteristic drop near the low energy end at all pressures and pressures and their shapes represent non-Maxwellian plasma and exhibit more like Druyvesteyn energy distribution.v

Rao, M. V. V. S.↗

Langmuir Probe and Mass Spectroscopic Measurements in Inductively Coupled CF4 Plasmas

Abstract Electron and ion energy distribution functions and other plasma parameters such as plasma potential (V(sub p)) , electron temperature (T(sub e)), and electron and ion number densities (n (sub e) and n(sub i)) in low pressure CF4 plasmas have been measured. The experiments were conducted in a GEC cell using an inductively coupled plasma (ICP) device powered by a 13.56 MHz radio-frequency (rf) power source. The measurements were made at 300 W of input rf power at 10, 30 and 50 mTorr gas pressures. Langmuir probe measurements suggest that n(sub e), n(sub i) and V(sub p) remain constant over 60% of the central electrode area, beyond which they decrease. Within the limits of experimental error (+/- 0.25 eV), T(sub e) remains nearly constant over the electrode area. T(sub e) and V(sub p) increase with a decrease in pressure. n(sub e) and n(sub i) are not affected as significantly as T(sub e) or V(sub p) by variation in the gas pressure. The electron energy distribution function (EEDF) measurements indicate a highly non-Maxwellian plasma. CF3+ is the most dominant ion product of the plasma, followed by CF2+ and CF+. The concentrations of CF2+ and CF+ are much larger than that is possible from direct electron impact ionization of the parent gas. The cross-section data suggest that the direct electron impact ionization of fragment neutrals and negative ion production by electron attachment may be responsible for increase of the minor ions.

Rao, M. V. V. S.↗

Observed Coupling Between the International Space Station PCU Plasma and a FPMU Langmuir Probe Facilitated by the Geomagnetic Field

Electrical charging of the International Space Station (ISS) is a matter of serious concern resulting from the possibility of vehicle arcing and electrical shock hazard to crew during extravehicular activity (EVA). A Plasma Contactor Unit (PCU) was developed and integrated into ISS in order to control the ISS floating potential, thereby, minimize vehicle charging and associated hazards. One of the principle factors affecting ISS electrical charging is the ionosphere plasma state (i.e., electron temperature and density). To support ISS electrical charging studies a Floating Potential Monitoring Unit (FPMU) is also integrated into ISS in order to measure the ionosphere properties using Langmuir probes (LP). The FPMU was located on the Starboard side of ISS. The PCU is located near the center of ISS with its plasma exhaust pointed to port. From its integration on ISS in 2006 through November of 2009, the FPMU data exhibited nominal characteristics during PCU operation. On November 21, 2009 the FPMU was relocated from the Starboard location to a new Port location. After relocation significant enhanced noise was observed in both the LP current-voltage sweeps and the derived electron temperature data. The enhanced noise only occurred when the PCU was in discharge and at unique and repeatable locations of the ISS orbit. The cause of this enhanced noise was investigated. It was found that there is coupling occurring between the PCU plasma and the FPMU LP. In this paper we shall 1) present the on-orbit data and the presence of enhanced noise, 2) demonstrate that the coupling of the PCU plasma and the FPMU measurements is geomagnetically organized, 3) show that coupling of the PCU plasma and the FPMU is primarily due to and driven by particle-wave interaction and 4) show that the ionosphere conditions are adequate for Alfven waves to be generated by the PCU plasma.

Hartman, William↗

Mass Spectrometric and Langmuir Probe Measurements in Inductively Coupled Plasmas in Ar, CHF3/Ar and CHF3/Ar/O2 Mixtures

Absolute fluxes and energy distributions of ions in inductively coupled plasmas of Ar, CHF3/Ar, and CHF3/Ar/O2 have been measured. These plasmas were generated in a Gaseous Electronics Conference (GEC) cell modified for inductive coupling at pressures 10-50 mTorr and 100-300 W of 13.56 MHz radio frequency (RF) power in various feedgas mixtures. In pure Ar plasmas, the Ar(+) flux increases linearly with pressure as well as RF-power. Total ion flux in CHF3 mixtures decreases with increase in pressure and also CHF3 concentration. Relative ion fluxes observed in the present studies are analyzed with the help of available cross sections for electron impact ionization and charge-exchange ion-molecule reactions. Measurements of plasma potential, electron and ion number densities, electron energy distribution function, and mean electron energy have also been made in the center of the plasma with a RF compensated Langmuir probe. Plasma potential values are compared with the mean ion energies determined from the measured ion energy distributions and are consistent. Electron temperature, plasma potential, and mean ion energy vary inversely with pressure, but increase with CHF3 content in the mixture.

Kim, J. S.↗