Search NASA⌕ Search

SEARCH · Search NASA

Results for “Large Scale Heating Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

Measurements of micrometeorological parameters for testing large scale models

This annual report discusses work accomplished on the FIFE (First International Satellite Land-Surface Climatology) Project. It contains manuscripts and reports during the past year of Grant NAG 5-389. Of its six chapters, three treat soil heat flux, and two deal with information about the FIFE sites. The first chapter on net radiation and the fourth chapter are to be presented at the Agricultural and Forest Meteorology Conference to be held in March 1989 in Charleston, South Carolina.

Kanemasu, E. T.↗

Non-Venting Thermal and Humidity Control for EVA Suits

Future EVA suits need processes and systems to control internal temperature and humidity without venting water to the environment. This paper describes an absorption-based cooling and dehumidification system as well as laboratory demonstrations of the key processes. There are two main components in the system: an evaporation cooling and dehumidification garment (ECDG) that removes both sensible heat and latent heat from the pressure garment, and an absorber radiator that absorbs moisture and rejects heat to space by thermal radiation. This paper discusses the overall design of both components, and presents recent data demonstrating their operation. We developed a design and fabrication approach to produce prototypical heat/water absorbing elements for the ECDG, and demonstrated by test that these elements could absorb heat and moisture at a high flux. Proof-of-concept tests showed that an ECDG prototype absorbs heat and moisture at a rate of 85 W/ft under conditions that simulate operation in an EVA suit. The heat absorption was primarily due to direct absorption of water vapor. It is possible to construct large, flexible, durable cooling patches that can be incorporated into a cooling garment with this system. The proof-of-concept test data was scaled to calculate area needed for full metabolic loads, thus showing that it is feasible to use this technology in an EVA suit. Full-scale, lightweight absorber/radiator modules have also been built and tested. They can reject heat at a flux of 33 W/ft while maintaining ECDG operation at conditions that will provide a cool and dry environment inside the EVA suit.

Izenson, Mike↗

Large-Scale Hybrid Motor Testing

Hybrid rocket motors can be successfully demonstrated at a small scale virtually anywhere. There have been many suitcase sized portable test stands assembled for demonstration of hybrids. They show the safety of hybrid rockets to the audiences. These small show motors and small laboratory scale motors can give comparative burn rate data for development of different fuel/oxidizer combinations, however questions that are always asked when hybrids are mentioned for large scale applications are - how do they scale and has it been shown in a large motor? To answer those questions, large scale motor testing is required to verify the hybrid motor at its true size. The necessity to conduct large-scale hybrid rocket motor tests to validate the burn rate from the small motors to application size has been documented in several place^'^^.^. Comparison of small scale hybrid data to that of larger scale data indicates that the fuel burn rate goes down with increasing port size, even with the same oxidizer flux. This trend holds for conventional hybrid motors with forward oxidizer injection and HTPB based fuels. While the reason this is occurring would make a great paper or study or thesis, it is not thoroughly understood at this time. Potential causes include the fact that since hybrid combustion is boundary layer driven, the larger port sizes reduce the interaction (radiation, mixing and heat transfer) from the core region of the port. This chapter focuses on some of the large, prototype sized testing of hybrid motors. The largest motors tested have been AMROC s 250K-lbf thrust motor at Edwards Air Force Base and the Hybrid Propulsion Demonstration Program s 250K-lbf thrust motor at Stennis Space Center. Numerous smaller tests were performed to support the burn rate, stability and scaling concepts that went into the development of those large motors.

Story, George↗

Implications of post-processing induced microstructural changes on the deformation and fracture response of additively manufactured Ti–6Al–4V

Ti–6Al–4V parts fabricated via electron beam melting (EBM) powder bed fusion are often subjected to hot isostatic pressing below the β-transus temperature to mitigate defects. During which the pressure aids in pore closure and the thermal exposure results in coarsening of α phase while retaining the columnar prior-β phase grain morphology present in the as-fabricated condition. The same post-processing treatment can also be carried out above β-transus temperature which is an effective way to modify both the grain morphology and the associated α textures. Here, the objective of this work is to correlate thermally induced microstructural changes to the deformation and fracture response of the EBM processed Ti–6Al–4V. To this end, we have carried out both sub-transus and super-transus heat-treatments of the as-fabricated material. The mechanical response of the as-fabricated and all heat-treated materials are characterized by in-situ tensile tests under a high-resolution digital optical microscope. This enabled us to capture large-scale panoramic images of the deforming microstructure, and overcome the trade-off between the image resolution and the field of view during in-situ experiments. The series of images captured throughout the imposed deformation are subsequently used to perform microstructure-based digital image correlation to measure microstructural-scale strains over a large area. The results of the in-situ tests together with detailed fractographic analyses are then used to elucidate how the heterogeneous deformation spanning over multiple microstructural length-scales, for example, at the scale of lamellae, colonies of lamellae and grain boundaries, affect the overall deformation and fracture response of the post-processed materials.

36 MATERIALS SCIENCE↗

Ames T-3 fire test facility - Aircraft crash fire simulation

There is a need to characterize the thermal response of materials exposed to aircraft fuel fires. Large scale open fire tests are costly and pollute the local environment. This paper describes the construction and operation of a subscale fire test that simulates the heat flux levels and thermochemistry of typical open pool fires. It has been termed the Ames T-3 Test and has been used extensively by NASA since 1969 to observe the behavior of materials exposed to JP-4 fuel fires.

Fish, R. H.↗

Aura MLS Cloud Measurements: First-Year Results

Aura MLS provides the first vertical upper tropospheric cloud profiling from space, enabling global survey of the vertical structure of cloud systems, with seasonal and geographical variations, needed to evaluate the way clouds are parameterized in global models, thereby contributing to the understanding of cloud-climate feedbacks, and improved weather and climate predictions. The vertical structure of cloud systems is fundamentally important for understanding how clouds affect both their regional and large-scale atmospheric and radiative environments. The regional cloud profiles provide a critical tests of important parameterizations that enable the calculation of radiative flux profiles and heating rates throughout the atmospheric column, which in turn also regulates the water and energy cycles in the upper troposphere

Microwave Limb Sounder (MLS)↗

Lap Shear Testing of Candidate Radiator Panel Adhesives

During testing of a subscale radiator section used to develop manufacturing techniques for a full-scale radiator panel, the adhesive bonds between the titanium heat pipes and the aluminum face sheets failed during installation and operation. Analysis revealed that the thermal expansion mismatch between the two metals resulted in relatively large shear stresses being developed even when operating the radiator at moderate temperatures. Lap shear testing of the adhesive used in the original joints demonstrated that the two-part epoxy adhesive fell far short of the strength required. A literature review resulted in several candidate adhesives being selected for lap shear joint testing at room temperature and 398 K, the nominal radiator operating temperature. The results showed that two-part epoxies cured at room and elevated temperatures generally did not perform well. Epoxy film adhesives cured at elevated temperatures, on the other hand, did very well with most being sufficiently strong to cause yielding in the titanium sheet used for the joints. The use of an epoxy primer generally improved the strength of the joint. Based upon these results, a new adhesive was selected for the second subscale radiator section.

Ellis, David↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Identification of Aircraft by Rockwell Test

A large number of tests were made on tubes of 1025 and 4130X steel, in various diameters and wall thicknesses, and after diverse heat treatments. The Rockwell B scale was employed, as being the best suited to the ranges of hardness encountered. Only satisfactory chrome molybdenum tubes were found to show a hardness in excess of 90-B after normalizing. The method therefore provided the desired means of identification of chrome molybdenum steel. It is a qualitative test only. The conditions of a satisfactory test are as follows. 1) The tubing must be normalized. 2) It must be clean inside and out at the point where the test is to be made. 3) The tube must be held in correct alignment with the penetrator and must not move during the test. 4) For thin-walled tubes, the anvil must extend within the tube so as to support the wall.

Knerr, Horace↗

The modification and application of Kuo's parameterization of cumulus convection in middle latitudes

An evaluation to reveal physical insight into the involved mechanisms through a combination of the large scale heat and moisture budgets and formulation of the latent heat released was performed. To improve upon the treatment of the interaction of deep convection with the environment, modifications consisting of considerations of the large scale moisture supply and of the vertical transport of moisture and of dry static energy inside the cloud are made. Also, a two layer cloud ensemble model is combined with the modified scheme. An examination of the modified scheme is performed by combining the large scale heat and moisture budgets and the modified formulation of the latent heat released. The modified parameterization procedures are compared with the original scheme, and the results of tests of both schemes are discussed. A variational optimization scheme is developed to analyze the wind field such that the integrated continuity equation and the global boundary condition are satisfied.

Liang, W. J.↗

Development, fabrication and test of a high purity silica heat shield

A highly reflective hyperpure ( 25 ppm ion impurities) slip cast fused silica heat shield material developed for planetary entry probes was successfully scaled up. Process development activities for slip casting large parts included green strength improvements, casting slip preparation, aggregate casting, strength, reflectance, and subscale fabrication. Successful fabrication of a one-half scale Saturn probe (shape and size) heat shield was accomplished while maintaining the silica high purity and reflectance through the scale-up process. However, stress analysis of this original aggregate slip cast material indicated a small margin of safety (MS. = +4%) using a factor of safety of 1.25. An alternate hyperpure material formulation to increase the strength and toughness for a greater safety margin was evaluated. The alternate material incorporates short hyperpure silica fibers into the casting slip. The best formulation evaluated has a 50% by weight fiber addition resulting in an 80% increase in flexural strength and a 170% increase in toughness over the original aggregate slip cast materials with comparable reflectance.

Rusert, E. L.↗

Macro-micro multiscale modeling to assist the design of HPDC Al castings microstructure and alloys for EV super-large body structures (Phase 1)

Implementation of High Pressure Die Casting (HPDC) Aluminum (Al) body structures for high volume electrified vehicles (EV) to improve electric efficiency remains a key strategy within many original equipment manufacturer (OEM)s. In addition to high strength for safety requirements, superior Self-Piercing Riveting (SPR) performance is demanded for HPDC Al alloys to be compatible with high volume SPR joining. In this work, it is proposed to extend and validate an existing Contractor finite element multiscale macro-micro modeling approach to quantify the influence of the microstructure of HPDC alloys on the fracture strain/displacement under 3-point bend and clinch testing. The success of this work will allow to replace solution treatment stage with low energy consumption heat treatment (HT) processes, or to design new non heat treatable (NHT) HPDC Al alloys to eliminate HT requirements. Ultimately, this project will facilitate the application of HPDC Al alloys for super-large vehicle structures to significantly reduce vehicle weight, and thus improving energy efficiency. The purpose of this project is to extend and validate an existing finite element code, which is based on the Contractor developed macro-micro multi-scale modeling approach, to numerically simulate the three-point bending and clinch test and study the influences of material microstructural characteristics and phase properties on the rivetability. The macro-micro modeling approach begins with a sample scale model and identify the location, which is mostly prone to failure, the deformation history of the boundaries of that location calculated will be used to drive a microstructure-based sub-models where the material microstructure and microscale properties are considered. Using this approach, the wrap-bending failure for two Al alloys are correctly predicted for the first time. This will start with phase I effort of building a framework of macro-micro three point bending test and clinch test of Al10SiMgMn HPDC alloy in the as-cast and T7 heat treated conditions. Those results will then be validated with experimental test results. The phase II effort will involve the utilization of the knowledge learned in phase I to establish the quantitative correlation between the microstructure characteristics and the riveting performance, which will be further used to guide the optimization of HPDC Al alloy microstructure using heat treatment process to achieve sufficient rivetability to join large thin-wall HPDC alloys.

36 MATERIALS SCIENCE↗

Short Duration Base Heating Test Improvements

Significant improvements have been made to a short duration space launch vehicle base heating test technique. This technique was first developed during the 1960's to investigate launch vehicle plume induced convective environments. Recent improvements include the use of coiled nitrogen buffer gas lines upstream of the hydrogen / oxygen propellant charge tubes, fast acting solenoid valves, stand alone gas delivery and data acquisition systems, and an integrated model design code. Technique improvements were successfully demonstrated during a 2.25% scale X-33 base heating test conducted in the NASA/MSFC Nozzle Test Facility in early 1999. Cost savings of approximately an order of magnitude over previous tests were realized due in large part to these improvements.

Bender, Robert L.↗

Mechanisms of Diurnal Precipitation over the United States Great Plains: A Cloud-Resolving Model Simulation

The mechanisms of summertime diurnal precipitation in the US Great Plains were examined with the two-dimensional (2D) Goddard Cumulus Ensemble (GCE) cloud-resolving model (CRM). The model was constrained by the observed large-scale background state and surface flux derived from the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Program s Intensive Observing Period (IOP) data at the Southern Great Plains (SGP). The model, when continuously-forced by realistic surface flux and large-scale advection, simulates reasonably well the temporal evolution of the observed rainfall episodes, particularly for the strongly forced precipitation events. However, the model exhibits a deficiency for the weakly forced events driven by diurnal convection. Additional tests were run with the GCE model in order to discriminate between the mechanisms that determine daytime and nighttime convection. In these tests, the model was constrained with the same repeating diurnal variation in the large-scale advection and/or surface flux. The results indicate that it is primarily the surface heat and moisture flux that is responsible for the development of deep convection in the afternoon, whereas the large-scale upward motion and associated moisture advection play an important role in preconditioning nocturnal convection. In the nighttime, high clouds are continuously built up through their interaction and feedback with long-wave radiation, eventually initiating deep convection from the boundary layer. Without these upper-level destabilization processes, the model tends to produce only daytime convection in response to boundary layer heating. This study suggests that the correct simulation of the diurnal variation in precipitation requires that the free-atmospheric destabilization mechanisms resolved in the CRM simulation must be adequately parameterized in current general circulation models (GCMs) many of which are overly sensitive to the parameterized boundary layer heating.

Lee, M.-I.↗

Detailed Velocity, Temperature, and Heat Flux Measurements on a Large Scale Film Cooling Model

To investigate the flow physics of turbine film cooling, detailed mean and fluctuating velocity and temperature surveys were made in the turbulent jet flow field behind a row of large scale film cooling holes. Additionally, surface heat transfer, film effectiveness, and turbulent heat flux values were determined. Measurements were made in the NASA Engine Research Building (ERB) SW-6 test facility, which consists of an 8.15-in2 open-inlet wind tunnel with a temperature-controlled secondary flow system. The film-cooling test plate fit into the wind tunnel such that the heat transfer surface formed the wind tunnel floor. This plate consisted of a three-hole array of film cooling holes that were fed from a plenum of different temperature.

Fluid Mechanics↗

Development and Experimental Validation of a Heat Transfer Model for Spilled Molten Salt Pools

A spill of radionuclide-bearing molten salt is one of the major postulated events that needs to be analyzed for liquid fluorine salt-cooled high-temperature reactor (FHR) or molten salt reactor licensing purposes. In this postulated event, radioactive source term materials (RSTMs) in the molten salt are discharged from the reactor vessel to the reactor building. The release of RSTMs from the spilled salt pool to the gas space in the reactor building is expected to be controlled by the cooling behavior of the spilled salt, including the growth and shrinkage of the solid crust on the surface of the spilled salt pool. This paper presents a simulation model for spilled salt pool heat transfer and validation efforts. The validation data come from two molten salt spill tests that were performed recently: the PELE2 test by the Rapid Experimental Laboratory of Kairos Power LLC (KP) and the Argonne salt cooling test conducted by Argonne National Laboratory. The former was a large-scale test involving kilograms of molten spilled FLiNaK salt, and the latter was a relatively smaller-scale test targeting various processes associated with a salt spill event. Both tests generated valuable data sets that can be used to assess salt cooling and validate evaluation models. This paper provides a new one-dimensional model that can simulate the cooling process of a spilled salt pool as well as the thermal responses of heat structures, such as the stainless steel liner and the concrete below the salt. The model has been implemented as part of KP-SAM code, which is a branch of the systems code SAM specific to KP FHR. In conclusion, the simulation results of the model are compared with the data of the PELE2 and Argonne tests, and reasonable agreements are observed between the model and test data.

heat transfer model↗

Large Vehicle Lunar Landing Surface Interaction and In-Situ Resource Based Risk Mitigation: Landing & Launch Pads

A key capability required for the exploration of planetary bodies is the ability to land on the surface. Previous work performed by NASA and other institutions has primarily focused on landing small spacecraft on planetary surfaces and the associated small-to-medium thrusters required for the soft landing. In the case of human exploration—particularly the establishment of long duration exploration and habitation outposts—the ability to land large landers, such as the SpaceX Starship, is necessary. These larger landing systems require the use of more powerful engines, with higher engine exhaust temperatures and higher landing loads. Understanding the excavation of material by the engines, as well as the potential for the landing legs to sink into the subsurface, is key in ensuring reliable and safe landings. A further improvement in landing reliability can be achieved by constructing landing / launch pads, especially with in-situ resources. Some material excavation by the plume is inevitable, leaving at least a portion of the surface scoured and uneven under the lander and ejecting regolith particles and rocks at very high velocities. One possible solution would be to robotically build landing / launch pads (ideally autonomously) at the destination using in-situ materials. In this case, the first one or few landers will need to land on unimproved surfaces at higher risk; however, they would bring the required equipment to build the landing pads with mostly local resources, thus increasing the reliability of safe landing for subsequent larger landers. A number of methods to build in-situ landing and launch pads have already been developed. These methods include no or some addition of required binder additives to the local regolith material, different processing approaches and result in varying landing pad strengths. A sub-scale rocket engine plume, was used to simulate some of the conditions of a landing on the Moon to assess the effectiveness of various materials for an in-situ built landing pad, The GO2/GCH4 rocket engine fired on 1m2 area coupons of representative pad materials. The results will allow continued development towards materials that satisfy the landing pad properties required for the effective risk reduction and increased reliability for landing people and equipment on the lunar surface. This work contained two parts: (1) computer modeling of a large rocket engine plume interacting with regolith on the Moon, using the Granular Gas Flow Solver (GGFS) provided by CFD Research Corporation as well as other computational fluid dynamics codes (CFD) such as Loci/CHEM. (2) Developing landing/launch pad materials that could be used for in-situ construction on the lunar surface in the future, to mitigate the calculated effects of a large vehicle rocket engine landing and launching on the Moon. The resulting computed values of plume impingement surface temperature, stagnation pressure, gas velocity, shear stress and heat flux were then matched as closely as possible in the Earth’s atmosphere in a sub-scale rocket engine GO2/CH4 test which was provided by Masten Space Systems in Mojave, California. The rocket engine was mounted on a test stand with vertical translation capabilities so that the landing operations of a lander could be simulated (Figure 1).The pad materials test coupons were placed at the surface of a large bin containing simulated lunar basalt regolith and subjected to a test firing as shown in Figure 2. The results of this testing will be presented with related findings, analysis and discussion.

Plume Surface Interaction↗