Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser drill”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Martian Chlorobenzene Identified by Curiosity in Yellowknife Bay: Evidence for the Preservation of Organics in a Mudstone on Mars

The Sample Analysis at Mars (SAM) instrument on the Curiosity rover is designed to determine the inventory of organic and inorganic volatiles thermally evolved from solid samples using a combination of evolved gas analysis (EGA), gas chromatography mass spectrometry (GCMS), and tunable laser spectroscopy. The first sample analyzed by SAM at the Rocknest (RN) aeolian deposit revealed chlorohydrocarbons derived primarily from reactions between a martian oxychlorine phase (e.g. perchlorate) and terrestrial carbon from N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) vapor present in the SAM instrument background. No conclusive evidence for martian chlorohydrocarbons in the RN sand was found. After RN, Curiosity traveled to Yellowknife Bay and drilled two holes separated by 2.75 m designated John Klein (JK) and Cumberland (CB). Analyses of JK and CB by both SAM and the CheMin x-ray diffraction instrument revealed a mudstone (called Sheepbed) consisting of approx.20 wt% smectite clays, which on Earth are known to aid the concentration and preservation of organic matter. Last year at LPSC we reported elevated abundances of chlorobenzene (CBZ) and a more diverse suite of chlorinated hydrocarbons including dichloroalkanes in CB compared to RN, suggesting that martian or meteoritic organic compounds may be preserved in the mudstone. Here we present SAM data from additional analyses of the CB sample and of Confidence Hills (CH), another drill sample collected at the base of Mt. Sharp. This new SAM data along with supporting laboratory analog experiments indicate that most of the chlorobenzene detected in CB is derived from martian organic matter preserved in the mudstone.

Glavin, D.↗

Martian Chlorobenzene Identified by Curiosity in Yellowknife Bay: Evidence for the Preservation of Organics in a Mudstone on Mars

The Sample Analysis at Mars (SAM) instrument on the Curiosity rover is designed to determine the inventory of organic and inorganic volatiles thermally evolved from solid samples using a combination of evolved gas analysis (EGA), gas chromatography mass spectrometry (GCMS), and tunable laser spectroscopy. The first sample analyzed by SAM at the Rocknest (RN) aeolian deposit revealed chlorohydrocarbons derived primarily from reactions between a martian oxychlorine phase (e.g. perchlorate) and terrestrial carbon from N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) vapor present in the SAM instrument background. No conclusive evidence for martian chlorohydrocarbons in the RN sand was found. After RN, Curiosity traveled to Yellowknife Bay and drilled two holes separated by 2.75 m designated John Klein (JK) and Cumberland (CB). Analyses of JK and CB by both SAM and the CheMin x-ray diffraction instrument revealed a mudstone (called Sheepbed) consisting of approx.20 wt% smectite clays, which on Earth are known to aid the concentration and preservation of organic matter. Last year at LPSC we reported elevated abundances of chlorobenzene (CBZ) and a more diverse suite of chlorinated hydrocarbons including dichloroalkanes in CB compared to RN, suggesting that martian or meteoritic organic compounds may be preserved in the mudstone. Here we present SAM data from additional analyses of the CB sample and of Confidence Hills (CH), another drill sample collected at the base of Mt. Sharp. This new SAM data along with supporting laboratory analog experiments indicate that most of the chlorobenzene detected in CB is derived from martian organic matter preserved in the mudstone.

Curiosity in Yellowknife↗

NASA Technologies that Benefit Society

Applications developed on Earth of technology needed for space flight have produced thousands of spinoffs that contribute to improving national security, the economy, productivity and lifestyle. Over the course of it s history, NASA has nurtured partnerships with the private sector to facilitate the transfer of NASA-developed technology. For every dollar spent on research and development in the space program, it receives back $7 back in the form of corporate and personal income taxes from increased jobs and economic growth. A new technology, known as Liquid-metal alloy, is the result of a project funded by NASA s Jet Propulsion Lab. The unique technology is a blend of titanium, zirconium, nickel, copper and beryllium that achieves a strength greater than titanium. NASA plans to use this metal in the construction of a drill that will help for the search of water beneath the surface of Mars. Many other applications include opportunities in aerospace, defense, military, automotive, medical instrumentation and sporting goods.Developed in the 1980 s, the original Sun Tigers Inc sunlight-filtering lens has withstood the test of time. This technology was first reported in 1987 by NASA s JPL. Two scientists from JPL were later tasked with studying the harmful effects of radiation produced during laser and welding work. They came up with a transparent welding curtain that absorbs, filters and scatters light to maximize protection of human eyes. The two scientists then began doing business as Eagle Eye Optics. Each pair of sunglasses comes complete with ultraviolet protection, dual layer scratch resistant coating, polarized filters for maximum protection against glare and high visual clarity. Sufficient evidence shows that damage to the eye, especially to the retina, starts much earlier than most people realize. Sun filtering sunglasses are important. Winglets seen at the tips of airplane wings are among aviations most visible fuel-saving, performance enhancing technology. Aerodynamics centers on two majors forces-lift and drag. Lift enables the plane to fly and drag is the resistance encountered while moving through the air. The air coming off the end of a standard wing, in a vortex, causes significant drag and turbulence, forcing the spacing between takeoffs. A Langley engineer for NASA published finding in 1976 and verified by test in 1977 that winglets produce a 7 percent increase in lift-drag ratio with a 20 percent decrease in drag. This configuration reduces emissions, allows for greater range and carry more payload and the planes fly more quietly. Winglet technology has saved 2 billion gallons of jet fuel worldwide in 2010. Aerogel represents what technology experts believe to be the best insulation material ever invented. It is very light, flexible and can withstand temperatures of minus 3000 deg F. Aerogel products will be found in everything from clothing, to building insulation to space vehicles. Corpo Nove incorporated the Spaceloft version of the NASA-developed aerogel material into this jacket which was test during an Antarctic expedition.

Griffin, Amanda↗

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

Towards Accurate Prediction of Turbulent, Three-Dimensional, Recirculating Flows with the NCC

The National Combustion Code (NCC) was used to calculate the steady state, nonreacting flow field of a prototype Lean Direct Injection (LDI) swirler. This configuration used nine groups of eight holes drilled at a thirty-five degree angle to induce swirl. These nine groups created swirl in the same direction, or a corotating pattern. The static pressure drop across the holes was fixed at approximately four percent. Computations were performed on one quarter of the geometry, because the geometry is considered rotationally periodic every ninety degrees. The final computational grid used was approximately 2.26 million tetrahedral cells, and a cubic nonlinear k - epsilon model was used to model turbulence. The NCC results were then compared to time averaged Laser Doppler Velocimetry (LDV) data. The LDV measurements were performed on the full geometry, but four ninths of the geometry was measured. One-, two-, and three-dimensional representations of both flow fields are presented. The NCC computations compare both qualitatively and quantitatively well to the LDV data, but differences exist downstream. The comparison is encouraging, and shows that NCC can be used for future injector design studies. To improve the flow prediction accuracy of turbulent, three-dimensional, recirculating flow fields with the NCC, recommendations are given.

Iannetti, A.↗

Origin of Chlorobenzene Detected by the Curiosity Rover in Yellowknife Bay: Evidence for Martian Organics in the Sheepbed Mudstone?

The Sample Analysis at Mars (SAM) instrument on the Curiosity rover is designed to determine the inventory of organic and inorganic volatiles thermally evolved from solid samples using a combination of evolved gas analysis (EGA), gas chromatography mass spectrometry (GCMS), and tunable laser spectroscopy. The first solid samples analyzed by SAM, a scoop of windblown dust and sand at Rocknest (RN), revealed chlorinated hydrocarbons derived primarily from reactions between a martian oxychlorine phase (e.g. perchlorate) and terrestrial carbon from N-methyl-N-(tert-butyldimethylsilyl)-trifluoroacetamide (MTBSTFA) vapor present in the SAM instrument background. Chlorobenzene (CBZ) was also identified by SAM GCMS at RN at trace levels (approx.0.007 nmol) and was attributed to the reaction of chlorine with the Tenax polymers used in the hydrocarbon traps. After the RN analyses, Curiosity traveled to Yellowknife Bay and drilled two separate holes designated John Klein (JK) and Cumberland (CB). Analyses of JK and CB by both SAM and the CheMin x-ray diffraction instrument revealed a mudstone consisting of approx.20 wt% smectite clays, which on Earth are known to aid the concentration and preservation of organic matter. In addition, higher abundances and a more diverse suite of chlorinated hydrocarbons in CB compared to RN suggests that martian or meteoritic organic sources may be preserved in the mudstone. Here we discuss the SAM EGA and GCMS measurements of volatiles released from the Sheepbed mudstone. We focus primarily on the elevated CBZ detections at CB and laboratory analog experiments conducted to help determine if CBZ is derived from primarily terrestrial, martian, or a combination of sources.

origin of↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Mars Immunoassay Life Detection Instrument (MILDI)

The direct detection of organic biomarkers for living or fossil microbes on Mars by an in situ instrument is a worthy goal for future lander missions. We have proposed an instrument based on immunological reactions to specific antibodies to cause activation of fluorescent stains. Antibodies are raised or acquired to a variety of general and specific substances that might be in Mars soil. These antibodies are then combined with various fluorescent stains and applied to small numbered spots on a small (two to three centimeters) test plate where they become firmly attached after drying. On Mars, a sample of soil from a trench or drill core is extracted with water and/or an organic solvent that is then applied to the test plate. Any substance, which has an antibody on the test plate, will react with its antibody and activate its fluorescent stain. A small ultraviolet light source will illuminate the test plate, which is observed with a small CCD camera. The numbered spots that fluoresce indicate the presence of the tested-for substance, and the intensity indicates relative amounts. The entire instrument can be quite small and light, on the order of ten cm in each dimension. A possible choice for light source may be small UV lasers at several wavelengths. Up to 1000 different sample spots can be placed on a plate 3 cm on a side, but a more practical number might be 100. Each antibody can have a redundant position for independent verification of reaction. Some of the wells or spots can contain simply standard fluorescent stains used to detect live cells, dead cells, DNA, etc. These the stains in these spots may be directly activated; no antibodies are necessary.

McKay, David↗

Changes in Black Carbon Deposition to Antarctica from Two Ice Core Records, A.D. 1850-2000

Continuous flow analysis was based on a steady sample flow and in-line detection of BC and other chemical substances as described in McConnell et al. (2007). In the cold room, previously cut one meter ice core sticks of 3x3cm, are melted continuously on a heated melter head specifically designed to eliminate contamination from the atmosphere or by the external parts of the ice. The melted ice from the most inner part of the ice stick is continuously pumped by a peristaltic pump and carried to a clean lab by Teflon lines. The recorded signal is continuous, integrating a sample volume of about 0.05 mL, for which the temporal resolution depends on the speed of melting, ice density and snow accumulation rate at the ice core drilling site. For annual accumulation derived from the WAIS and Law Dome ice cores, we assumed ~3.1 cm water equivalent uncertainty in each year's accumulation from short scale spatial variability (glaciological noise) which was determined from several measurements of annual accumulation in multiple parallel ice cores notably from the WAIS Divide ice core site (Banta et al., 2008) and from South Pole site (McConnell et al., 1997; McConnell et al., 2000). Refractory black carbon (rBC) concentrations were determined using the same method as in (Bisiaux et al., 2011) and adapted to continuous flow measurements as described by (McConnell et al., 2007). The technique uses a single particle intracavity laser induced incandescence photometer (SP2, Droplet Measurement Technologies, Boulder, Colorado) coupled to an ultrasonic nebulizer/desolvation (CETAC UT5000) Flow Injection Analysis (FIA). All analyses, sample preparation etc, were performed in a class 100 cleanroom using anti contamination "clean techniques". The samples were not acidified.

Bisiaux, Marion M.↗

Comparison of atomized mass and crater volume in laser ablation

The extent and dynamics of laser ablation are typically studied using crater imaging or by invoking the relationship between atomic emission and the mass removed. The former is a static view of a dynamic process and requires the accumulation of multiple shots in one location. The latter is complex and not absolute without calibration of the optical system with a standard of spectral radiance. We measure the mass of the atomized plume by laser atomic-absorption spectroscopy at 2 µs without external mass calibration; mass uncertainty in laser-ablation atomic absorption spectroscopy (LA-AAS) results from uncertainties in line area fitting, tabulated oscillator strengths, and partition functions as well as a <10% underrepresentation of the mass due to treating the plasma as a single thermodynamic equilibrium. The LA-AAS-measured mass pertains to the atoms in the probed charge states and does not include condensed or molecular species. The ablation efficiency at 300 mbar of helium varies significantly between the two focusing conditions used. A comparison of crater-derived masses and LA-AAS masses suggests that more defocused ablation may result in significant redeposition of material in the crater, distorting the conclusions from drilling studies and crater imaging. More focused ablation conditions result in crater-derived masses that exceed those measured with LA-AAS and suggest melt expulsion or phase explosion.

Merten, Jonathan [Arkansas State University, Jones↗

Mineralogy, Provenance, and Diagenesis of a Potassic Basaltic Sandstone on Mars: CheMin X-Ray Diffraction of the Windjana Sample (Kimberley Area, Gale Crater)

The Windjana drill sample, a sandstone of the Dillinger member (Kimberley formation, Gale Crater, Mars), was analyzed by CheMin X-ray diffraction (XRD) in the MSL Curiosity rover. From Rietveld refinements of its XRD pattern, Windjana contains the following: sanidine (21% weight, approximately Or(sub 95)); augite (20%); magnetite (12%); pigeonite; olivine; plagioclase; amorphous and smectitic material (approximately 25%); and percent levels of others including ilmenite, fluorapatite, and bassanite. From mass balance on the Alpha Proton X-ray Spectrometer (APXS) chemical analysis, the amorphous material is Fe rich with nearly no other cations-like ferrihydrite. The Windjana sample shows little alteration and was likely cemented by its magnetite and ferrihydrite. From ChemCam Laser-Induced Breakdown Spectrometer (LIBS) chemical analyses, Windjana is representative of the Dillinger and Mount Remarkable members of the Kimberley formation. LIBS data suggest that the Kimberley sediments include at least three chemical components. The most K-rich targets have 5.6% K2O, approximately 1.8 times that of Windjana, implying a sediment component with greater than 40% sanidine, e.g., a trachyte. A second component is rich in mafic minerals, with little feldspar (like a shergottite). A third component is richer in plagioclase and in Na2O, and is likely to be basaltic. The K-rich sediment component is consistent with APXS and ChemCam observations of K-rich rocks elsewhere in Gale Crater. The source of this sediment component was likely volcanic. The presence of sediment from many igneous sources, in concert with Curiosity's identifications of other igneous materials (e.g.,mugearite), implies that the northern rim of Gale Crater exposes a diverse igneous complex, at least as diverse as that found in similar-age terranes on Earth.

Treiman, Allan H.↗

Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

Mora, Maria F.↗

Calibration of the Fluorine, Chlorine and Hydrogen Content of Apatites With the ChemCam LIBS Instrument

Determining the composition of apatites is important to understand the behavior of volatiles during planetary differentiation. Apatite is an ubiquitous magmatic mineral in the SNC meteorites. It is a significant reservoir of halogens in these meteorites and has been used to estimate the halogen budget of Mars. Apatites have been identified in sandstones and pebbles at Gale crater by ChemCam, a Laser-Induced Breakdown Spectroscometer (LIBS) instrument onboard the Curiosity rover. Their presence was inferred from correlations between calcium, fluorine (using the CaF molecular band centered near 603 nm, whose detection limit is much lower that atomic or ionic lines and, in some cases, phosphorus (whose detection limit is much larger). An initial quantification of fluorine, based on fluorite (CaF2)/basalt mixtures and obtained at the LANL laboratory, indicated that the excess of F/Ca (compared to the stoichiometry of pure fluorapatites) found on Mars in some cases could be explained by the presence of fluorite. Chlorine was not detected in these targets, at least above a detection limit of 0.6 wt% estimated from. Fluorapatite was later also detected by X-ray diffraction (with CheMin) at a level of approx.1wt% in the Windjana drill sample (Kimberley area), and several points analyzed by ChemCam in this area also revealed a correlation between Ca and F. The in situ detection of F-rich, Cl-poor apatites contrasts with the Cl-rich, F-poor compositions of apatites found in basaltic shergottites and in gabbroic clasts from the martian meteorite NWA 7034, which were also found to be more Cl-rich than apatites from basalts on Earth, the Moon, or Vesta. The in situ observations could call into question one of the few possible explanations brought forward to explain the SNC results, namely that Mars may be highly depleted in fluorine. The purpose of the present study is to refine the calibration of the F, Cl, OH and P signals measured by the ChemCam LIBS instrument, initiated for F, for Cl in soils, for P, and estimate their limit of detection. For this purpose, different types of apatites and mixtures of basalt powder and apatites were analyzed using ChemCam Engineering Qualification Model (EQM) at IRAP, Toulouse. The present abstract presents the initial results from the laboratory analyses. Differences between the response function of the EQM and the Flight Model of ChemCam are still to be refined to apply these new results to the Martian dataset.

Meslin, P.-Y.↗

Biotechnology Approaches to Life Detection

The direct detection of organic biomarkers for living or fossil microbes on Mars by an in situ instrument is a worthy goal for future lander missions. Several new and innovative biotechnology approaches are being explored. Firstly we have proposed an instrument based on immunological reactions to specific antibodies to cause activation of fluorescent stains. Antibodies are raised or acquired to a variety of general and specific substances that might be in Mars soil. These antibodies are then combined with various fluorescent stains and applied to micron sized numbered spots on a small (2-3 cm) test plate where they become firmly attached after freeze drying. Using technology that has been developed for gene mining in DNA technology up to 10,000 tests per square inch can now be applied to a test plate. On Mars or the planet/moon of interest, a sample of soil from a trench or drill core is extracted with water and/or an organic solvent and ultrasonication and then applied to the test plate. Any substance, which has an antibody on the test plate, will react with its antibody and activate its fluorescent stain. At the moment a small UV light source will illuminate the test plate, which is observed with a small CCD camera, although other detection systems will be applied. The numbered spots that fluoresce indicate the presence of the tested-for substance, and the intensity indicates relative amounts. Furthermore with up to a thousand test plates available false positives and several variations of antibody can also be screened for. The entire instrument can be quite small and light, on the order of 10 cm in each dimension. A possible choice for light source may be small UV lasers at several wavelengths. Some of the wells or spots can contain simply standard fluorescent stains used to detect live cells, dead cells, DNA, etc. The stains in these spots may be directly activated, with no antibodies being necessary. The proposed system will look for three classes of biomarkers: those from extant life, such as DNA, those from extinct life such as hopanes, and those from organic compounds not necessarily associated with life such as PAHs, rocket exhaust contamination and other a/pre-biotic chemicals. Both monoclonal and polyclonal antibodies can be used. Monoclonal antibodies react with a very specific compound, but polyclonal antibodies may react to any of a whole family of compounds. Furthermore the technique of phage display to raise antibodies against classically non-antigenic molecules is also being considered. Additional information is contained in the original extended abstract.

Steele, Andrew↗

Terrain Physical Properties Derived from Orbital Data and the First 360 Sols of Mars Science Laboratory Curiosity Rover Observations in Gale Crater

Physical properties of terrains encountered by the Curiosity rover during the rst 360 sols of operations have been inferred from analysis of the scour zones produced by Sky Crane Landing System engine plumes, wheel touch down dynamics, pits produced by Chemical Camera (ChemCam) laser shots, rover wheel traverses over rocks, the extent of sinkage into soils, and the magnitude and sign of rover-based slippage during drives. Results have been integrated with morphologic, mineralogic, and thermophysical properties derived from orbital data, and Curiosity-based measurements, to understand the nature and origin of physical properties of traversed terrains. The hummocky plains (HP) landing site and traverse locations consist ofmoderately to well-consolidated bedrock of alluvial origin variably covered by slightly cohesive, hard-packedbasaltic sand and dust, with both embedded and surface-strewn rock clasts. Rock clasts have been addedthrough local bedrock weathering and impact ejecta emplacement and form a pavement-like surface in whichonly small clasts (5 to 10 cm wide) have been pressed into the soil during wheel passages. The beddedfractured (BF) unit, site of Curiositys rst drilling activity, exposes several alluvial-lacustrine bedrock unitswith little to no soil cover and varying degrees of lithication. Small wheel sinkage values (1 cm) for both HPand BF surfaces demonstrate that compaction resistance countering driven-wheel thrust has been minimaland that rover slippage while traversing across horizontal surfaces or going uphill, and skid going downhill,have been dominated by terrain tilts and wheel-surface material shear modulus values.

Mars Science Laboratory Curiosity Gale Crater↗

High-Pressure Synthesis of Bulk Cobalt Cementite, Co 3 C

Transition metal carbides find use in a wide range of advanced high-resilience applications including high-strength steels, heat shields, and deep-earth drills. However, carbides of the mid-to-late transition metals remain difficult to isolate and characterize on account of their metastability, which precludes the preparation of high-quality bulk single crystal samples using traditional solid-state methods. Herein, we report a combined computational and experimental survey of the cobalt-carbon binary system under high pressures and demonstrate that pressure offers a route toward the bulk synthesis of the metastable cementite-type cobalt carbide, Co 3 C, which under ambient conditions can only be prepared in low-dimensional thin film or nanoparticle forms. First-principles calculations reveal two competitive low-energy stoichiometric phases under ambient pressures - Pnnm-Co 2 C (Fe 2 C-type) and Pnma-Co 3 C (Fe 3 Ctype) - consistent with the known low-dimensional phases that have been studied for their promising magnetic properties. However, the calculated formation enthalpy of Pnma-Co 3 C decreases steadily with the applied pressure, while that of Pnnm-Co 2 C increases. Here, we pursue these results using high-pressure laser-heated synthesis methods coupled with in situ X-ray diffraction and observe the formation of Pnma-Co 3 C above 4.8 GPa. We determine the experimental bulk modulus of Co 3 C to be K o = 237 GPa (K p = 4.0). First-principles calculations of the phonon modes in Co 3 C reveal dynamical instabilities at ambient pressure that are absent under compression. These results offer a promising new route for the synthesis of rare-earth-free magnets.

36 MATERIALS SCIENCE↗

Fiber optic system for direct detection of CO 2 leakage in carbon storage wells (Abbreviated Final Report)

The feasibility study focused on the development of new fiber for distributed chemical sensing that will allow direct detection of CO2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CSS), which can provide early warning for an incoming well failure and potential CO2 leaking through it. We proposed Raman or IR interrogation within gas-filled Holey Fibers (HoFs) interleaved with Fiber Bragg Grating (FBG) sections, so that the location and concentration of the gases would be provided simultaneously. The methodology would overcome current roadblocks to using fiber optics for CO2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure. We were able to assess commercially available IR/Raman hollow core fiber and demonstrated detection of CO2 through them in our controlled environment setups at various pressure conditions. We have also established the ability of drilling precisely with fs-lases side holes to enable penetration of CO2 into the hollow core fiber and reduce diffusion rates. Open joint collars were also explored with double functionality: to obtain splice to solid core fiber critical for field deployment and create gas ingress locations. Both diffusion-only and pressurized fiber system have been constructed following COMSOL based semi-hybrid optical /fluidodynamics models. FBGs have been identified and procured and characterized. Along the work we leveraged internal modeling/design, photonics/laser characterization, optical fiber fabrication, and AM lab capabilities to design, develop and test in-house components or assemblies. Our results indicate the potential of HoF for CO2 downhole direct detection.

25 ENERGY STORAGE↗