Search NASA⌕ Search

SEARCH · Search NASA

Results for “Library”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Constructing a Tandem Mass Spectral Library for Forensic Ricin Identification

Ricin, a protein found in castor seeds, is a lethal toxin that is designated as a category 2 select agent. Because castor seeds are easy to obtain and the toxin can be easily extracted, cases of attempted ricin poisoning are relatively common. A shotgun proteomics method for ricin identification has recently been developed (manuscript in preparation), in which ricin peptides are identified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) followed by proteomics database search, and peptide-spectrum matches are verified and compared to standard spectra by a human expert. To make this process more reproducible, objective, and high-throughput, we have created a ricin spectral library for peptide identification to supplement the human review step. To construct these spectral libraries, two pure ricin samples (from a proposed standard reference material) and crude castor seed extracts were digested with trypsin and analyzed using a standard shotgun LC-MS/MS protocol. Spectral libraries were created from the filtered search results from four database search tools. The library was then used in a search using SpectraST on samples from castor seeds. Analysis showed that the spectral library search resulted in more peptides identified from crude castor seed samples compared to MS-GF+ and Sequest plus Percolator. These results suggest that computational comparison of putative ricin peptide spectra to library spectra can be an effective method of confirming the presence of ricin, and that spectral library search may be suitable to augment the more manual and subjective aspects of the currently recommended human expert review.

Spectral Library, Ricin, forensic, proteomic↗

SU-G-BRB-02: An Open-Source Software Analysis Library for Linear Accelerator Quality Assurance

Purpose: Routine linac quality assurance (QA) tests have become complex enough to require automation of most test analyses. A new data analysis software library was built that allows physicists to automate routine linear accelerator quality assurance tests. The package is open source, code tested, and benchmarked. Methods: Images and data were generated on a TrueBeam linac for the following routine QA tests: VMAT, starshot, CBCT, machine logs, Winston Lutz, and picket fence. The analysis library was built using the general programming language Python. Each test was analyzed with the library algorithms and compared to manual measurements taken at the time of acquisition. Results: VMAT QA results agreed within 0.1% between the library and manual measurements. Machine logs (dynalogs & trajectory logs) were successfully parsed; mechanical axis positions were verified for accuracy and MLC fluence agreed well with EPID measurements. CBCT QA measurements were within 10 HU and 0.2mm where applicable. Winston Lutz isocenter size measurements were within 0.2mm of TrueBeam’s Machine Performance Check. Starshot analysis was within 0.2mm of the Winston Lutz results for the same conditions. Picket fence images with and without a known error showed that the library was capable of detecting MLC offsets within 0.02mm. Conclusion: A new routine QA software library has been benchmarked and is available for use by the community. The library is open-source and extensible for use in larger systems.

43 PARTICLE ACCELERATORS↗

The Extended IRTF Spectral Library: Expanded Coverage in Metallicity, Temperature, and Surface Gravity

We present a 0.7–2.5 μm spectral library of 284 stars observed with the medium-resolution infrared spectrograph, SpeX, at the 3.0 m NASA Infrared Telescope Facility (IRTF) on Maunakea, Hawaii. This library extends the metallicity range of the IRTF Cool Star library beyond solar metallicity to −1.7 < [Fe/H] < 0.6. All of the observed stars are also in the MILES optical stellar library, providing continuous spectral coverage for each star from 0.35 to 2.5 μm. The spectra are absolute flux calibrated using Two Micron All Sky Survey photometry, and the continuum shape of the spectra is preserved during the data reduction process. Synthesized JHK {sub S} colors agree with observed colors at the 1%–2% level, on average. We also present a spectral interpolator that uses the library to create a data-driven model of spectra as a function of T{sub eff}, log g, and [Fe/H]. We use the library and interpolator to compare empirical trends with theoretical predictions of spectral feature behavior as a function of stellar parameters. These comparisons extend to the previously difficult to access low-metallicity and cool dwarf regimes, as well as the previously poorly sampled super-solar metallicity regime. The library and interpolator are publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainties of responses calculated with a 'tuned' library - Geometrical and algebraic insights

The standard American evaluated nuclear data library ENDF/B-VII was 'tuned' based on simple measured critical assemblies. This tuning was not done according to a fully defined mathematical algorithm, such as the adjustment algorithm. In this work, we investigate how tuning affects the uncertainties (covariances) of the cross-section libraries. First, we analyze what happens to cross-section uncertainties as a result of adjustment. The effect of adjustment on the uncertainties is geometrically demonstrated for simple cases. For those parts of the sensitivities of the assembly to be calculated that are parallel to the sensitivities of the assemblies on which adjustment was based, there is significant reduction in the uncertainties. For orthogonal parts, there is no change in the uncertainties. These findings are algebraically proven based on the adjustment algorithm. Then we analyze the differences between tuned libraries and adjusted libraries. We conclude that for tuned libraries, the uncertainties in the direction of sensitivities on which adjustment or tuning were based are improved, similar to the improvement for an adjusted library. However, the displacement of the nominal values of the library parameters to their tuned value, instead of their adjusted value, adds an additional uncertainty. This additional uncertainty is typically small in the direction that was improved by adjustment. The magnitude of the additional uncertainty in perpendicular directions depends on the particular details of the tuning performed. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IAEA Photonuclear Data Library 2019

Here, photo-induced reaction cross section data are of importance for a variety of current or emerging applications, such as radiation shielding design and radiation transport analyses, calculations of absorbed dose in the human body during radiotherapy, physics and technology of fission reactors (influence of photo-reactions on neutron balance) and fusion reactors (plasma diagnostics and shielding), activation analyses, safeguards and inspection technologies, nuclear waste transmutation, medical isotope production and astrophysical applications. To address these data needs the IAEA Photonuclear Data library was produced in 1999, containing evaluated photo-induced cross sections and neutron spectra for 164 nuclides which were deemed relevant for the applications. Since the release of the IAEA Photonuclear Data Library however, new experimental data as well as new methods to assess the reliability of experimental cross sections have become available. Theoretical models and input parameters used to evaluate photo-induced reactions have improved significantly over the years. In addition, new measurements of partial photoneutron cross sections using mono-energetic photon beams and advanced neutron detection systems have been performed allowing for the validation of the evaluations and assessments of the experimental data. Furthermore, technological advances have led to the construction of new and more powerful gamma-beam facilities, therefore new data needs are emerging. We report our coordinated efforts to address these data needs and present the results of the new up-to-date evaluations included in the new updated IAEA Photonuclear Data Library consisting of 219 nuclides. The new library includes 188 new evaluations produced by the CRP evaluators, and one evaluation taken from the JENDL/PD-2016 library, while 20 evaluations were retained from the previous 1999 IAEA Photonuclear Data Library. In most of the cases, the photon energy goes up to 200 MeV. A total of 55 nuclides are new in this library reflecting the progress in measurements but also the developing data needs. In this paper we discuss the new assessment method and make recommendations to the user community in cases where the experimental data are discrepant and the assessments disagree. In addition, in the absence of experimental data, we present model predictions for photo-induced reaction cross section on nuclides of potential interest to medical radioisotope production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A comprehensive spectral assay library to quantify the Halobacterium salinarum NRC-1 proteome by DIA/SWATH-MS

Data-Independent Acquisition (DIA) is a mass spectrometry-based method to reliably identify and reproducibly quantify large fractions of a target proteome. The peptide-centric data analysis strategy employed in DIA requires a priori generated spectral assay libraries. Such assay libraries allow to extract quantitative data in a targeted approach and have been generated for human, mouse, zebrafish, E. coli and few other organisms. However, a spectral assay library for the extreme halophilic archaeon Halobacterium salinarum NRC-1, a model organism that contributed to several notable discoveries, is not publicly available yet. Here, we report a comprehensive spectral assay library to measure 2,563 of 2,646 annotated H. salinarum NRC-1 proteins. We demonstrate the utility of this library by measuring global protein abundances over time under standard growth conditions. The H. salinarum NRC-1 library includes 21,074 distinct peptides representing 97% of the predicted proteome and provides a new, valuable resource to confidently measure and quantify any protein of this archaeon. Data and spectral assay libraries are available via ProteomeXchange (PXD042770, PXD042774) and SWATHAtlas (SAL00312-SAL00319).

59 BASIC BIOLOGICAL SCIENCES↗

A local-view array library for partitioned global address space C++programs

Multidimensional arrays are an important data structure in many scientific applications. Unfortunately, built-in support for such arrays is inadequate in C++, particularly in the distributed setting where bulk communication operations are required for good performance. In this paper, we present a multidimensional library for partitioned global address space (PGAS) programs, supporting the one-sided remote access and bulk operations of the PGAS model. The library is based on Titanium arrays, which have proven to provide good productivity and performance. These arrays provide a local view of data, where each rank constructs its own portion of a global data structure, matching the local view of execution common to PGAS programs and providing maximum flexibility in structuring global data. Unlike Titanium, which has its own compiler with array-specific analyses, optimizations, and code generation, we implement multidimensional arrays solely through a C++library. The main goal of this effort is to provide a library-based implementation that can match the productivity and performance of a compiler-based approach. We implement the array library as an extension to UPC++, a C++library for PGAS programs, and we extend Titanium arrays with specializations to improve performance. We evaluate the array library by porting four Titanium benchmarks to UPC++, demonstrating that it can achieve up to 25% better performance than Titanium without a significant increase in programmer effort..

Kamil, A↗

Dimensionality Reduction Library v 0.2

Dimensionality Reduction Library is a C++ library for dimensionality reduction. In the context of this library, dimensionality reduction is considered to consist of 1)estimation of the intrinsic dimensionality using sampled data, 2) Finding maps that reduce the dimensionality of data (forward map) or increase the dimensionality of data (reverse map) and 3) mapping arbitray coordinates to high and low dimensionalities. The library is intended to provide a consistent interface to multiple dimensionality reduction algorithms with an efficient C++ interface that runs efficiently on multicore architectures. A few routines have been optimized with an option for GPU acceleration or distributed computation. Currently the library offers intrinsic dimensionality estimation using point-PCA reconstruction error and/ residual variance. The following dimensionality reduction methods have been implemented: Principal Component Analysis Multidimensional Scaling Locally Linear Embedding IsoMap Autoencoder Neutral Networks An executable is also supplied that can be built to allow for command-line access to the library routines. A description for an application of the library for molecular structure analysis has been published.

BROWN, WILLIAM↗

Hermes Utility Libraries and Tools

This software is a set of utility libraries and tools developed in support of multiple scientific simulation projects. These libraries provide many general-purpose capabilities, such as a compact, extensible, machine-independent binary file format for various forms of scientific data, a Fortran-callable command parser that supports symbolic variables, looping, and conditional constructs, a Fortran-callable interface to ITT Corporation's callable IDL graphics and data analysis, a multi-block, 2D electrostatic solver, a machine-independent Fortran interface to standard system services, and various Fortran-callable dynamic memory services. In some cases, C interfaces are also provided. In addition, some tools that use these various libraries are available. A brief description of each library/tool follows: PFF library - PFF is a compact, extensible, machine-independent binary file format for various forms of scientific data. Two libraries are provided: one designed to be called from Fortran 77, and the other designed to be called from C or C++. Dataset types for several varieties of scientific data are built into the library, and new dataset types can be added. The libraries provide support for reading/writing these datasets from/to PFF files, as well as functionality for interactive processing of PFF files and the data they contain. Tools for manipulating, converting, and comparing PFF data are also available.

Seidel, DavidB.↗

SCALE MG Cross Section Processing for High Void BWR Using the AMPX 1,597-group Library

The CASL VERA neutronic simulator MPACT has been developed by Oak Ridge National Laboratory (ORNL) and University of Michigan for the pressurized water reactor applications. The MPACT capability is being extended for the boiling water reactor (BWR) analysis. Recent investigation showed that the MPACT multigroup (MG) library has limitations for high void BWR fuels because of the very coarse group structure. Since the MPACT MG library is generated with the AMPX/SCALE code package developed at ORNL, enhancement of the AMPX/SCALE code package and its MG library must be preceded to improve the accuracy of the MPACT MG library. Therefore, a new 1597-group structure was developed and an AMPX 1597-group library was generated. This ultra-fine group (UFG) library resulted in significant improvements in accuracy for fast spectrum systems compared to the AMPX 252-group results. However, the use of the AMPX 1597-group library requires significantly increased burden on memory and computing time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmarking of ENDF/B-VIII.1 Thermal Scattering Library for Hydrogen

In correctly characterizing the energy and momentum transfer at thermal and cold energies between neutrons and its interacting medium, thermal scattering libraries, which details energy states due to the intra- and inter-molecular bond effects for the medium materials, are applied in place of free-gas cross section libraries in a particle transport simulation code. They are essential to the neutron performance of a neutron facility like SNS, where thermalized neutrons from 20 K liquid hydrogen and ambient (~300 K) water are transported to the beamlines for neutron scattering experiments in studying materials. Recently, a new version of thermal scattering library for parahydrogen and orthohydrogen at 14-20 K was developed and to be released in ENDF/B-VIII.1. It is, therefore, important to benchmark its impacts on the prediction of moderator performance due to the updates in the thermal scattering library. In this study, the recent ENDF/B-VIII.1 thermal scattering library was compared to the current ENDF/B-VII.1 one in the neutron performance calculations for the decoupled and coupled hydrogen moderators at SNS under theorized and real working conditions. In addition, the predictions using both thermal scattering libraries were benchmarked to the measurements of moderator performance. The consistency between the libraries was observed mostly for parahydrogen and the difference in orthohydrogen at cold neutron energies was noted.

Lu, Wei↗

Selecting Minimal Motion Primitive Libraries with Genetic Algorithms

Motion primitives allow for application of discrete search algorithms to rapidly produce trajectories in complex continuous space. The maneuver automaton (MA) provides an elegant formulation for creating a primitive library based on trims and maneuvers. However, performance is fundamentally limited by the contents of the primitive library. If the library is too sparse, performance can be poor in terms of path cost, whereas a library that is too large can increase run time. This work outlines new methods for using genetic algorithms to prune a primitive library. The proposed methods balance the path cost and planning time while maintaining the reachability of the MA. The genetic algorithm in this paper evaluates and mutates populations of motion primitive libraries to optimize both objectives. Here, we illustrate the performance of these methods with a simulated study using a nonlinear medium-fidelity F-16 model. We optimize a library with the presented algorithm for obstacle-free navigation and a nap-of-the-Earth navigation task. In the obstacle-free navigation task, we show a tradeoff of a 10.16% higher planning cost for a 96.63% improvement in run time. In the nap-of-the-Earth task, we show a tradeoff of a 9.712% higher planning cost for a 92.06% improvement in run time.

42 ENGINEERING↗

Illumina Unamplified Indexed Library Construction: An Automated Approach

Manual library construction is a limiting factor in Illumina sequencing. Constructing libraries by hand is costly, time-consuming, low-throughput, and ergonomically hazardous, and constructing multiple libraries introduces risk of library failure due to pipetting errors. The ability to construct multiple libraries simultaneously in automated fashion represents significant cost and time savings. Here we present a strategy to construct up to 96 unamplified indexed libraries using Illumina TruSeq reagents and a Biomek FX robotic platform. We also present data to indicate that this library construction method has little or no risk of cross-contamination between samples.

59 BASIC BIOLOGICAL SCIENCES↗

Dimensionality Reduction Library v 0.2

Dimensionality Reduction Library is a C++ library for dimensionality reduction. In the context of this library, dimensionality reduction is considered to consist of 1)estimation of the intrinsic dimensionality using sampled data, 2) Finding maps that reduce the diemsionality of data (forward map) or increase the dimensionality of data (reverse map) and 3) mapping arbitray coordiantes to high and low dimensionalities. The library is intended toprovide a consistent interface to multiple dimensionality reduction algorithms with an efficient C++ interface that runs efficiently on multicore architectures. A few routines have been optimized with an option for GPU acceleration or distributed computation. Currently the library offers intrinsic dimensionality estimation using point-PCA reconstruction error and/ residual variance. The following dimensionality reduction methods have been implemented: Principal Component Analysis Multidimensional Scaling Locally Linear Embedding IsoMap Autoencoder Neutral Networks An executable is also supplied that can be built to allow for command-line access to the library routines. A description for an applciation of the library for molecular structure analysis has been published.

BROWN, WILLIAM↗

Development and Testing of Nuclear Data Libraries for Improved Energy Deposition Modeling - Paper 144

Accurate calculations of local energy deposition rates require the presence of gamma production data (GPD) in the nuclear data library used by radiation transport codes such as MCNP5, MONACO, or Denovo. The lack of GPD in the underlying nuclear data library can cause significant over-prediction of local heat generation rates with a corresponding under-prediction of heat generation rates away from a region of interest. To address this concern, continuous energy (CE) and multigroup (MG) cross section libraries with additional GPD have been created. Both ACE- and AMPX-formatted CE libraries, as well as ANISN- and AMPX-formatted MG libraries, have been created and are undergoing verification and validation (V and V) testing. A hybrid data set consisting of cross-section evaluations from five different nuclear data repositories has been developed. This hybrid data set, referred to as GPD-Rev0, is intended to support enhanced energy deposition calculations. Code-specific libraries in CE ACE, CE AMPX, MG AMPX, and MG ANISN formats have been created from the GPD-Rev0 data set. V and V testing has demonstrated that these various code-specific libraries are performing well for the intended applications. Localized over- and under-predictions of HFIR heating rates have been addressed without adversely affecting the prediction of other key operating parameters. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Extending a Tandem Mass Spectral Library to Include MS{sup 2} Spectra of Fragment Ions Produced In-Source and MS{sup n} Spectra

Tandem mass spectral library searching is finding increased use as an effective means of determining chemical identity in mass spectrometry-based omics studies. We previously reported on constructing a tandem mass spectral library that includes spectra for multiple precursor ions for each analyte. Here we report our method for expanding this library to include MS{sup 2} spectra of fragment ions generated during the ionization process (in-source fragment ions) as well as MS{sup 3} and MS{sup 4} spectra. These can assist the chemical identification process. A simple density-based clustering algorithm was used to cluster all significant precursor ions from MS{sup 1} scans for an analyte acquired during an infusion experiment. The MS{sup 2} spectra associated with these precursor ions were grouped into the same precursor clusters. Subsequently, a new top-down hierarchical divisive clustering algorithm was developed for clustering the spectra from fragmentation of ions in each precursor cluster, including the MS{sup 2} spectra of the original precursors and of the in-source fragments as well as the MS{sup n} spectra. This algorithm starts with all the spectra of one precursor in one cluster and then separates them into sub-clusters of similar spectra based on the fragment patterns. Herein, we describe the algorithms and spectral evaluation methods for extending the library. The new library features were demonstrated by searching the high resolution spectra of E. coli extracts against the extended library, allowing identification of compounds and their in-source fragment ions in a manner that was not possible before. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A NEW SYNTHETIC LIBRARY OF THE NEAR-INFRARED Ca II TRIPLET INDICES. I. INDEX DEFINITION, CALIBRATION, AND RELATIONS WITH STELLAR ATMOSPHERIC PARAMETERS

Adopting the SPECTRUM package, which is a stellar spectral synthesis program, we have synthesized a comprehensive set of 2890 near-infrared (NIR) synthetic spectra with a resolution and wavelength sampling similar to the Sloan Digital Sky Survey (SDSS) and the forthcoming Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) spectra. During the synthesis, we applied the 'New grids of ATLAS9 Model Atmosphere' to develop a grid of local thermodynamic equilibrium model atmospheres for effective temperatures (T{sub eff}) ranging from 3500 to 7500 K, for surface gravities (log g) from 0.5 to 5.0 dex, for metallicities ([Fe/H]) from -4.0 to 0.5 dex, and for solar ([{alpha}/Fe] = 0.0 dex) and non-solar ([{alpha}/Fe] = +0.4 dex) abundances. This synthetic stellar library is composed of 1350 solar scaled abundance (SSA) and 1530 non-solar scaled abundance (NSSA) spectra, grounding on which we have defined a new set of NIR Ca II triplet indices and an index CaT as the sum of the three. These defined indices were automatically measured on every spectrum of the synthetic stellar library and calibrated with the indices computed on the observational spectra from the INDO-U.S. stellar library. In order to check the effect of {alpha}-element enhancement on the so-defined Ca II indices, we compared indices measured on the SSA spectra with those on the NSSA ones at the same trine of stellar parameters (T{sub eff}, log g, [Fe/H]); luckily, little influences of {alpha}-element enhancement were found. Furthermore, comparisons of our synthetic indices with the observational ones from measurements on the INDO-U.S. stellar library, the SDSS-DR7 and SDSS-DR8 spectroscopic survey are presented, respectively, for dwarfs and giants in specific. For dwarfs, our synthetic indices could well reproduce the behaviors of the observational indices versus stellar parameters, which verifies the validity of our index definitions for dwarfs. For giants, the consistency between our synthetic indices and the observational ones does not appear to be as good. However, a new synthetic library of NIR Ca II indices has been founded for deeper studies on the NIR wave band of stellar spectra, and this library is particularly appropriate for the SDSS and the forthcoming LAMOST stellar spectra. We have regressed the strength of the CaT index as a function of stellar parameters for both dwarfs and giants after a series of experimental investigations into relations of the indices with stellar parameters. For dwarfs, log g has little effect on the indices, while [Fe/H] and T{sub eff} play a role together. The leading factor is probably [Fe/H], which changes the strength of the indices by a positive trend. For giants, log g starts to influence the strength of the indices by a negative trend for the metal-poor, and even impact deeply for the metal-rich; besides, [Fe/H] and T{sub eff} still matter. In addition, we briefly discussed the major differences between our Ca II triplet indices and the CaHK doublet indices. Ultimately, a supplemental experiment was carried out to show that spectral noises do have effects on our set of NIR Ca II indices. However, the influence is not weak enough to be ignored if the signal-to-noise ratio falls below 20.

79 ASTRONOMY AND ASTROPHYSICS↗

Library based x-ray scatter correction for dedicated cone beam breast CT

Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. Conclusions: The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors’ approach is effective and stable, and is therefore clinically attractive for CBBCT imaging.

60 APPLIED LIFE SCIENCES↗