Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Twilight Intensity Variation of the Infrared Hydroxyl Airglow

The vibration rotation bands of the hydroxyl radical are the strongest features in the night airglow and are exceeded in intensity in the dayglow only by the infrared atmospheric bands of oxygen. The variation of intensity during evening twilight is discussed. Using a ground-based Fourier Transform Spectrometer (FTS), hydroxyl intensity measurements as early as 3 deg solar depression were made. Models of the twilight behavior show that this should be sufficient to provide measurement of the main portion of the twilight intensity change. The instrument was equipped with a liquid nitrogen-cooled germanium detector whose high sensitivity combined with the efficiency of the FTS technique permits spectra of the region 1.1 to 1.6 microns at high signal-to-noise to be obtained in two minutes. The use of a polarizer at the entrance aperture of the instrument reduces the intensity of scattered sunlight by a factor of at least ten for zenith observations.

Lowe, R. P.↗

High spectral resolution measurements of a solar flare hard X-ray burst

Observations are reported of an intense solar flare hard X-ray burst on June 27, 1980, made with a balloon-borne array of liquid nitrogen-cooled Ge detector which provided unprecedented spectral resolution (no more than 1 keV FWHM). The hard X-ray spectra throughout the impulsive phase burst fitted well to a double power-law form, and emission from an isothermal 0.1-1 billion K plasma can be specifically excluded. The temporal variations of the spectrum indicate that the hard X-ray burst is made up of two superposed components: individual spikes lasting about 3-15 sec, which have a hard spectrum and a break energy of 30-65 keV; and a slowly varying component characterized by a soft spectrum with a constant low-energy slope and a break energy which increases from 25 kev to at least 100 keV through the event. The double power-law shape indicates that DC electric field acceleration, similar to that occurring in the earth's auroral zone, may be the source of the energetic electrons which produce the hard X-ray emission.

Lin, R. P.↗

A long-duration balloon payload for hard X-ray and gamma-ray observations of the sun

A balloon payload designed to study the processes of energy release, particle acceleration, and heating of the active corona in hard X-ray microflares and normal flares is described. An array of liquid nitrogen-cooled germanium detectors together with large area phoswich scintillation detectors provide the highest sensitivity (about 500 sq cm) and energy resolution (not greater than 0.7 keV) ever achieved for solar hard X-ray (about 15-600 keV) measurements. These detectors were flown in February 1987 from Australia on a long duration radiation controlled balloon flight (LDBF) which provided 12 days of observations before cutdown in Brazil. The payload includes solar cells for power, pointing, and navigation sensors, a microprocessor controlled data system with VCR tape storage, and transmitters for GOES and ARGOS spacecraft. This successful flight illustrates the potential of LDBFs for solar flare studies.

Lin, R. P.↗

Cryogenic Fourier spectrometer for measuring trace species in the lower stratosphere

A cryogenic Fourier transform spectrometer has been built to measure thermal emission of the earth's limb from a balloon-borne platform. Liquid nitrogen cooling of the spectrometer and liquid helium cooling of the detectors has provided sufficient sensitivity to detect, at 5-15 microns, fifteen molecular species relevant to stratospheric ozone chemistry. The spectral resolution achieved, 0.022/cm, is the best yet attained for emission mode data at these wavelengths. The philosophy behind the design of the optical and electronic systems is presented, followed by an analysis of the performance achieved during balloon flight.

Brasunas, John C.↗

The MIPAS balloon borne trace constitutent experiment

A novel cryogenic Fourier transform spectrometer (FTS) has been developed for limb emission measurements in the mid IR-region from balloon-borne platforms. The FTS is a rapid scanning interferometer using a modified Michelson arrangement which allows a spectral resolution of 0.04 cm(exp -1) to be achieved. Solid carbon-dioxide cooling of the spectrometer and liquid-helium cooling of the detectors provide adequate sensitivity. The line of sight can be stabilized in terms of azimuth and elevation. A three-mirror off-axis telescope provides good vertical resolution and straylight rejection. Calibration is performed by high elevation and internal blackbody measurements. Four balloon flights were performed, two of them during spring turn-around 1989 and 1990 over mid-latitudes (Aire sur L'Adour, France, 44 deg N) and two near the northern polar circle in winter 1992 (Esrange, Sweden, 68 deg N). Limb emission spectra were collected from 32 km to 39 km floating altitudes covering tangent heights between the lower troposphere and the floating altitude. The trace gases CO2, H2O, O3, CH4, N2O, HNO3, N2O5, ClONO2, CF2Cl2, CFCl3, CHF2Cl, CCl4, and C2H6 have been identified in the measured spectra. The 1989 data have been analyzed to retrieve profiles of O3, HNO3, CFCl3 and CF2Cl2. The flights over Kiruna have provided the first ever reported profile measurements of the key reservoir species ClONO2 and N2O5 inside the polar vortex.

Oelhaf, H.↗

Detectors and Focal Plane Modules for Weather Satellites

Weather satellite instruments require detectors with a variety of wavelengths ranging from the visible to VLWIR. One of the remote sensing applications is the geostationary GOES-ABI imager covering wavelengths from the 450 to 490 nm band through the 13.0 to 13.6 micron band. There are a total of 16 spectral bands covered. The Cross-track infrared Sounder (CrIS) is a Polar Orbiting interferometric sensor that measures earth radiances at high spectral resolution, using the data to provide pressure, temperature and moisture profiles of the atmosphere. The pressure, temperature and moisture sounding data are used in weather prediction models that track storms, predict levels of precipitation etc. The CrIS instrument contains SWIR (lamba(sub c) approximately 5 micron at 98K), MWIR (lambda(sub c) approximately 9 micron at 98K) and LWIRs (lamba(sub c) approximately 15.5 micron at 81K) bands in three Focal Plane Array Assemblies (FPAAs). GOES-ABI contains three focal plane modules (FPMs), (i) a visible-near infrared module consisting of three visible and three near infrared channels, (ii) a MWIR module comprised of five channels from 3.9 micron to 8.6 micron and (iii) a 9.6 micron to 13.3 micron, five-channel LWIR module. The VNIR FPM operates at 205 K, and the MWIR and LWIR FPMs operate at 60 K. Each spectral channel has a redundant array built into a single detector chip. Switching is thus permitted from the primary selected array in each channel to the redundant array, given any degradation in performance of the primary array during the course of the mission. Silicon p-i-n detectors are used for the 0.47 micron to 0.86 micron channels. The thirteen channels above 1 micron are fabricated in various compositions of Hg1-xCdxTe, and in this particular case using two different detector architectures. The 1.38 micron to 9.61 micron channels are all fabricated in Hg1-xCdxTe grown by Liquid Phase Epitaxy (LPE) using the HDVIP detector architecture. Molecular beam epitaxy (MBE)-grown Hg1-xCdxTe material are used for the LWIR 10.35 micron to 13.3 micron channels fabricated in Double layer planar heterostructure (DLPH) detectors. This is the same architecture used for the CrIS detectors CrIS detectors are 850 micron diameter detectors with each FPAA consisting of nine photovoltaic detectors arranged in a 3 x 3 pattern. Each detector has an accompanying cold preamplifier. SWIR and MWIR FPAAs operate at 98 K and the LWIR FPAA at 81 K, permitting the use of passive radiators to cool the detectors. D* requirements at peak wavelength are ≥ 5.0E+10 Jones for LWIR, ≥ 9.3E+10 Jones for MWIR and ≥ 3.0E+11 Jones for SWIR. All FPAAs exceeded the D* requirements. Measured mean values for the nine photodiodes in each of the LWIR, MWIR and SWIR FPAAs are D* = 5.3 x 10(exp 10) cm-Hz(exp 1/2)/W at 14.0 micron, 1.0 x 10(exp 11) cm-Hz(exp 1/2)/W at 8.0 micron and 3.1 x 10(exp 11) cm-Hz(exp 1/2)/W at 4.64 micron.

satellite instruments↗

Development of a motorized cryovalve for the control of superfluid liquid helium

Recent advances in the technology of infrared detectors have made possible a wide range of scientific measurements and investigations. One of the requirements for the use of sensitive IR detectors is that the entire instrument be cooled to temperatures approaching absolute zero. The cryogenic cooling system for these instruments is commonly designed as a large dewar containing liquid helium which completely surrounds the apparatus. Thus, there is a need for a remotely controlled, motorized cryovalve that is simple, reliable, and compact and can operate over extended periods of time in cryo-vac conditions. The design, development, and test of a motorized cryovalve with application to a variety of cryogenic systems currently under development is described.

Lorell, K. R.↗

Using Correlated Photons to Suppress Background Noise

A proposed method of suppressing the effect of background noise in an optical communication system would exploit the transmission and reception of correlated photons at the receiver. The method would not afford any advantage in a system in which performance is limited by shot noise. However, if the performance of the system is limited by background noise (e.g., sunlight in the case of a free-space optical communication system or incoherently scattered in-band photons in the case of a fiber-optic communication system), then the proposed method could offer an advantage: the proposed method would make it possible to achieve a signal-to-noise ratio (S/N) significantly greater than that of an otherwise equivalent background- noise-limited optical communication system based on the classical transmission and reception of uncorrelated photons. The figure schematically depicts a classical optical-communication system and a system according to the proposed method. In the classical system, a modulated laser beam is transmitted along an optical path to a receiver, the optics of which include a narrow-band-pass filter that suppresses some of the background noise. A photodetector in the receiver detects the laser-beam and background photons, most or all of which are uncorrelated. In the proposed system, correlated photons would be generated at the transmitter by making a modulated laser beam pass through a nonlinear parametric down-conversion crystal. The sum of frequencies of the correlated photons in each pair would equal the frequency of the incident photon from which they were generated. As in the classical system, the correlated photons would travel along an optical path to a receiver, where they would be band-pass filtered and detected. Unlike in the classical system, the photodetector in the receiver in this system would be one that intrinsically favors the detection of pairs of correlated photons over the detection of uncorrelated photons. Even though there would be no way of knowing the precise location and time of creation of a given pair of correlated signal photons in the nonlinear down-conversion crystal, the fact that the photons are necessarily created at the same time and place makes it possible to utilize conventional geometrical imaging optics to reunite the photons in coincidence in the receiving photodetector. Because most or all of the signal photons would be correlated while most or all of the noise photons would be uncorrelated, the S/N would be correspondingly enhanced in the photodetector output. An additional advantage to be gained by use of a correlated-photon detector is that it could be capable of recovering the signal even in the presence of background light so bright that a classical uncorrelated-photon detector would be saturated. A blocked-impurity-band (BIB) photodetector that preferentially detects pairs of correlated photons over uncorrelated ones and that operates at a quantum efficiency of 88 percent is commercially available. This detector must be cooled to the temperature of liquid helium to obtain the desired low-noise performance. It is planned to use this detector in a proof-of-principle demonstration. In addition, it may be possible to develop GaN-based photodetectors that could offer the desired low-noise performance at room temperature.

Jackson, Deborah↗

Crystal Growth Using MEPHISTO

The shuttle flight experiment "In Situ Monitoring of Crystal Growth Using MEPHISTO" was accomplished during STS-87 as part of the fourth flight of the United States Microgravity Payload (USMP-4), which was flown from November 19 to December 5, 1997. The data returned from that flight are just now beginning to yield quantitative results. This project is an international collaboration: the furnace system known as MEPHISTO was built in France by CNES (French National Space Agency) and CEA (French Atomic Energy Commission); the principal investigator, Prof. Reza Abbaschian, is from the University of Florida at Gainesville; and numerical and analytical modeling support includes collaborators from the University of New South Wales, Australia, the University of Wisconsin at Milwaukee, the National Institute of Standards and Technology, and the NASA Lewis Research Center. MEPHISTO is a French acronym that translates into English as Materials for the Study of Interesting Phenomena of Solidification on Earth and in Orbit. Since this was the fourth flight of the MEPHISTO furnace, the experiment is referred to as MEPHISTO-4. MEPHISTO-4 was a directional solidification experiment that studied the liquid-to-solid transformation of bismuth alloyed with tin. Directional solidification is a freezing technique common to the processing of the electronic materials used in integrated circuits and detectors, such as silicon and germanium. When liquids are frozen on Earth, they must be cooled. The cooling causes stirring because of density variations in the liquid. This stirring, known as natural convection, influences the quality of the resulting solid. During freezing, regions of high and low concentrations of tin are created. This introduces another important phenomenon: diffusion, or the movement by molecular action of matter from regions of high concentration to regions of lower concentration. In MEPHISTO-4, it is tin that diffuses from the high-concentration region in front of the solid-liquid interface to more distant low-concentration regions.

deGroh, Henry C., III↗

A Rapid Turnaround Cryogenic Detector Characterization System

Upcoming major NASA missions such as the Einstein Inflation Probe and the Single Aperture Far-Infrared Observatory require arrays of detectors with thousands of elements, operating at temperatures near l00 mK and sensitive to wavelengths from approx. 100 microns to approx. 3 mm. Such detectors represent a substantial enabling technology for these missions, and must be demonstrated soon in order for them to proceed. In order to make rapid progress on detector development, the cryogenic testing cycle must be made convenient and quick. We have developed a cryogenic detector characterization system capable of testing superconducting detector arrays in formats up to 8 x 32, read out by SQUID multiplexers. The system relies on the cooling of a two-stage adiabatic demagnetization refrigerator immersed in a liquid helium bath. This approach permits a detector to be cooled from 300K to 50 mK in about 4 hours, so that a test cycle begun in the morning will be over by the end of the day. Tine system is modular, with two identical immersible units, so that while one unit is cooling, the second can be reconfigured for the next battery of tests. We describe the design, construction, and performance of this cryogenic detector testing facility.

Benford, Dominic j.↗

Laser beam methane detector

Instrument uses infrared absorption to determine methane concentration in liquid natural gas vapor. Two sensors measure intensity of 3.39 mm laser beam after it passes through gas; absorption is proportional to concentration of methane. Instrument is used in modeling spread of LNG clouds and as leak detector on LNG carriers and installations. Unit includes wheels for mobility and is both vertically and horizontally operable.

Hinkley, E. D., Jr.↗

Detection of cracks in surface insulation

Volatile organic liquid surface penetrants used with appropriate detector paper leave tested surfaces uncontaminated. Method can be used to detect minute cracks in materials such as metal, glass, plastics, ceramics, etc.

Leger, L. J.↗

Laser heterodyne system for obtaining height profiles of minor species in the atmosphere

An infrared laser heterodyne system for obtaining height profiles of minor constituents of the atmosphere was developed and erected. A brief discription of the system is given. The system consists of a tunable CO2 waveguide laser in the 9 to 11 micrometer band, that is used as a local oscillator and a heliostat that follows the sun and brings in solar radiation, that is mixed with the laser beam in a high speed liquid nitrogen cooled mercury cadmium telluride detector. The detected signal is analysed in a RF spectrum analyser that allows tracing absorption line profiles. Absorption lines of a number of minor constituents in the troposphere and stratosphere, such as O3, NH3, H2O, SO2, ClO, N2O, are in the 9 to 11 micrometer band and overlap with that of CO2 laser range. The experimental system has been made operational and trial observations taken. Current measurements are limited to ozone height profiles. Results are presented.

Jain, S. L.↗

Infrared spectroscopy of the lower stratosphere with a balloon-borne cryogenic Fourier spectrometer

The IR limb emission of the lower stratosphere has been measured using a balloon-borne liquid nitrogen-cooled Michelson interferometer with liquid helium-cooled Si:Ga detectors. Portions of the thermal emission spectrum have been recorded between 650 and 2000/cm with an unapodized spectral resolution of 0.03/cm. This is the highest spectral resolution limb emission thus far obtained. A preliminary description is given of these data along with a discussion of the significant features. Species identified to date include CO2, O3, CFCl3, CF2Cl2, H2O, CH4, HNO3, N2O, NO2, and ClONO2. A tentative identification is made for NO, representing the first direct spectroscopic detection of NO in emission.

Kunde, Virgil G.↗

A liquid xenon imaging telescope for gamma ray astrophysics: Design and expected performance

A high resolution telescope for imaging cosmic x ray sources in the MeV region, with an angular resolution better than 0.5 deg is being developed as balloon-borne payload. The instrument consists of a 3-D liquid xenon TPC as x ray detector, coupled with a coded aperture at a distance of 1 meter. A study of the actual source distribution of the 1.809 MeV line from the decay of Al-26 and the 511 keV positron-electron annihilation line is among the scientific objectives, along with a search for new x ray sources. The telescope design parameters and expected minimum flux sensitivity to line and continuum radiation are presented. The unique capablity of the LXe-TPC as a Compton Polarimeter is also discussed.

Aprile, E.↗

Design and performance of transfer assembly for the infrared telescope for Space Lab 2

The cryogenic design features employed in the case of the Infrared Telescope (IRT) for Spacelab 2 are unique. They involve the delivery of helium gas at a temperature of 2 K to the IR detectors from a superfluid supply dewar which is separate from the telescope/detector unit. This design has the advantage that thermal and mechanical vibration disturbances in the liquid helium bath are decoupled from the IR detector. The interfacing of the storage dewar with the IRT telescope/detector unit (called cryostat) is the function of the subsystem which is called the transfer assembly (TA). The TA design is discussed, taking into account the porous plug module, the plumbing module, the helix module, and the dewar heat exchanger units. Aspects of transfer assembly performance are also considered.

Karr, G. R.↗

Mercuric iodide (HgI2) growth for nuclear detectors

The purpose of this investigation is to grow more-perfect mercuric iodide crystals in a low-gravity environment by taking advantage of diffusion-controlled growth conditions and by avoiding the problem of strain dislocations produced by the crystal's weight. This crystal has considerable practical importance as a sensitive gamma-ray detector and energy spectrometer that can operate at ambient temperature, as compared to presently available detectors that must be cooled to near liquid nitrogen temperatures. However, the performance of mercuric iodide crystals only rarely approaches the expected performance, presumably because some of the free electrical charges produced within the crystal are not collected at the electrodes, but instead remain trapped or immobilized at crystal defects. An efficient high atomic number semiconductor detector capable of operating at room temperature utilizing single HgI2 crystals offers a greater potential than existing detector technology.

Schnepple, W.↗