Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Conceptual Design of DUNE Near Detector Superconducting Magnet System

The Deep Underground Neutrino Experiment (DUNE) has formed a near detector design group (NDDG) tasked with delivering a CDR by the end of 2019. The DUNE Near Detectors will be housed in an underground hall on the Fermilab site. The two main detector systems are a liquid argon detector and a high-pressure gas time projection chamber (HPgTPC). The HPgTPC requires a magnet that generates a 0.5 T solenoidal magnetic field in a large volume of 6 m diameter, and 5 m length. Herein, we present a superconducting magnet system design. We investigated: an open air core magnet with three coils, and a five coils system having two active fringe field shielding coils. Coils positions were optimized to obtain the specified field homogeneity in the magnet good field region, while minimizing the Lorentz forces and the superconductor volume. We discuss the magnetic, mechanical, and thermal conceptual designs.

43 PARTICLE ACCELERATORS↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

High-performance Generic Neutrino Detection in a LArTPC near the Earth's Surface with the MicroBooNE Detector

Large Liquid Argon Time Projection Chambers (LArTPCs) are being increasingly adopted in neutrino oscillation experiments because of their superb imaging capabilities through the combination of both tracking and calorimetry in a fully active volume. Active LArTPC neutrino detectors at or near the Earth's surface, such as the MicroBooNE experiment, present a unique analysis challenge because of the large flux of cosmic-ray muons and the slow drift of ionization electrons. We present a novel Wire-Cell-based high-performance generic neutrino-detection technique implemented in MicroBooNE. The cosmic-ray background is reduced by a factor of 1.4$\times10^{5}$ resulting in a 9.7% cosmic contamination in the selected neutrino candidate events, for visible energies greater than 200~MeV, while the neutrino signal efficiency is retained at 88.4% for $\nu_{\mu}$ charged-current interactions in the fiducial volume in the same energy region. This significantly improved performance compared to existing reconstruction algorithms, marks a major milestone toward reaching the scientific goals of LArTPC neutrino oscillation experiments operating near the Earth's surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial and temporal evaluations of the liquid argon purity in ProtoDUNE-SP

Liquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP) was an approximately 700-ton liquid argon detector intended to prototype the Deep Underground Neutrino Experiment (DUNE) Far Detector Horizontal Drift module. It contains two drift volumes bisected by the cathode plane assembly, which is biased to create an almost uniform electric field in both volumes. The DUNE Far Detector modules must have robust cryogenic systems capable of filtering argon and supplying the TPC with clean liquid. This paper will explore comparisons of the argon purity measured by the purity monitors with those measured using muons in the TPC from October 2018 to November 2018. A new method is introduced to measure the liquid argon purity in the TPC using muons crossing both drift volumes of ProtoDUNE-SP. For extended periods on the timescale of weeks, the drift electron lifetime was measured to be above 30 ms using both systems. A particular focus will be placed on the measured purity of argon as a function of position in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cross Section Results from the MicroBooNE Experiment

The MicroBooNE detector is currently the largest operating liquid argon neutrino experiment in the world. Located at the Fermi National Accelerator Laboratory (Fermilab), MicroBooNE has been collecting both electron neutrino (\(\nu _{e}\)) and muon neutrino (\(\nu _{\mu }\)) interactions from both the Booster Neutrino Beam (BNB) and the Neutrino Main Injector (NuMI) since late 2015. During this time, MicroBooNE has measured a wide-variety of interaction topologies including \(\nu _{\mu }\) charged current, \(\nu _{e}\) charged current, resonant \(\pi ^{0}\), and various high multiplicity interactions. To date, many of MicroBooNE’s measurements are either the first of their kind using liquid argon as a target material, or have the largest number of events collected using a liquid argon detector. All of these measurements combine to form a rich cross section programme, aiming to enhance understanding of GeV-range neutrino interaction on liquid argon for upcoming detectors such as SBND, ICARUS, and DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimizing the hit finding algorithm for liquid argon TPC neutrino detectors using parallel architectures

Neutrinos are particles that interact rarely, so identifying them requires large detectors which produce lots of data. Processing this data with the computing power available is becoming even more difficult as the detectors increase in size to reach their physics goals. Liquid argon time projection chamber (LArTPC) neutrino experiments are expected to grow in the next decade to have 100 times more wires than in currently operating experiments, and modernization of LArTPC reconstruction code, including parallelization both at data- and instruction-level, will help to mitigate this challenge. The LArTPC hit finding algorithm is used across multiple experiments through a common software framework. In this paper we discuss a parallel implementation of this algorithm. Using a standalone setup we find speedup factors of two times from vectorization and 30–100 times from multi-threading on Intel architectures. The new version has been incorporated back into the framework so that it can be used by experiments. On a serial execution, the integrated version is about 10 times faster than the previous one and, once parallelization is enabled, more speedups comparable to the standalone program are achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction for Liquid Argon TPC Neutrino Detectors Using Parallel Architectures.

Neutrinos are particles that interact rarely, so identifying them re-quires large detectors which produce lots of data. Processing this data with thecomputing power available is becoming more dicult as the detectors increasein size to reach their physics goals. In liquid argon time projection chambers(TPCs) the charged particles from neutrino interactions produce ionization elec-trons which drift in an electric field towards a series of collection wires, and thesignal on the wires is used to reconstruct the interaction. The MicroBooNEdetector currently collecting data at Fermilab has 8000 wires, and planned fu-ture experiments like DUNE will have 100 times more, which means that thetime required to reconstruct an event will scale accordingly. Modernization ofliquid argon TPC reconstruction code, including vectorization, parallelizationand code portability to GPUs, will help to mitigate these challenges. The liquidargon TPC hit finding algorithm within theLArSoftframework used acrossmultiple experiments has been vectorized and parallelized. This increases thespeed of the algorithm on the order of ten times within a standalone version onIntel architectures. This new version has been incorporated back intoLArSoftso that it can be generally used. These methods will also be applied to otherlow-level reconstruction algorithms of the wire signals such as the deconvolu-tion. The applications and performance of this modernized liquid argon TPCwire reconstruction will be presented.

Berkman, Sophie↗

Search for slow magnetic monopoles with the NOvA detector on the surface

We report a search for a magnetic monopole component of the cosmic-ray flux in a 95-day exposure of the NOvA experiment’s Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of 2 × 10 -14 cm -2 s -1 sr -1 at 90% C.L. for monopole speed 6 × 10 -4 < β < 5 × 10 -3 and mass greater than 5 × 10 8 GeV. Because of NOvA’s small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing-Based Search for Magnetic Monopoles with the NOvA Detector on the Surface

We report a search for a magnetic monopole component of the cosmic-ray flux in a 2743-live-day exposure of the NOvA experiment's Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of $8\times 10^{-16}~\mathrm{cm^{-2}s^{-1}sr^{-1}}$ at 90% C.L. for monopole speed $6\times 10^{-4} < β< 5\times 10^{-3}$ and mass greater than $10^{9}$ GeV. Because of NOvA's small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region.

Abubakar, S. [Erciyes U.]↗

Improving ICARUS Track Reconstruction Algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino (SBN) program at Fermilab. The main goal of the experiment is to investigate the possibility of sterile neutrinos in the O(1 eV) mass region and provide clarification of the anomaly detected from the Liquid Scintillator Neutrino Detector (LSND) and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber (LAr-TPC), that can provide excellent 3D imaging and calorimetric reconstruction of any ionizing particles. This detection technique allows a detailed study of neutrino interactions, spanning a wide energy spectrum (from a few keV to several hundreds of GeV). The detector consists of two identical adjacent modules, filled with a total of 760 tons of ultra-pure liquid argon. Each module houses two LAr-TPCs separated by a common cathode with a maximum drift distance of 1.5 m, equivalent to about 1 ms drift time for the nominal $500$ V/m electric drift field. The anode is made of three parallel wire planes positioned 3 mm apart, where the stainless-steel wires are oriented on each plane at a different angle with respect to the horizontal direction ($+60^\degree$,$-60^\degree$,$0^\degree$). The first two planes (Induction 1 and Induction 2) provide a non-destructive charge measurement, whereas the ionization charge is fully collected by the last collection plane. In total, 53248 wires with a 3 mm pitch and length up to 9 m are installed in the detector. In the first stage of the reconstruction, segments of waveforms corresponding to physical signals (hits) are searched for in the deconvolved wire waveform with a threshold-based hit-finding algorithm. Each hit is then fitted with a Gaussian, whose area is proportional to the number of drift electrons generating the signal. In the second stage of the reconstruction, hits are passed as input to Pandora, a framework software composed of different pattern recognition algorithms, that performs a 3D reconstruction of the full image recorded in the collected event, including the identification of interaction vertices and tracks and showers inside the TPC. These are organized into a hierarchical structure (called slice) of particles generated starting from a primary interaction vertex. In some cases, related to the inefficiencies in the hit detection or excessive deflection of the particle trajectory, Pandora breaks the particle's track into two or more smaller pieces and considers each piece as an independent track. We studied this phenomenon focusing on primary muons from ν_μ CC interactions contained in a single module with a track at least 20 cm long, to exclude delta rays. The study determined that about $7-8\%$ of the muon tracks are broken. Approximately $80\%$ of the times, Pandora assigns all segments of the track to the same slice (intra-slice track split), while in the remaining $20\%$ of the cases, one of the segments is associated with another slice (extra-slice track split). To mitigate this phenomenon, we designed an algorithm that detects and stitches the tracks broken by Pandora for the intra-slice split. In Monte Carlo simulations, the algorithm showed an efficiency exceeding $80\%$ and a purity exceeding $93\%$.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

HydroX, a light dark matter search with hydrogen-doped liquid xenon time projection chambers

Experimental efforts searching for dark matter particles over the last few decades have ruled out many candidates led by the new generation of tonne-scale liquid xenon. For light dark matter, hydrogen could be a better target than xenon as it would offer a better kinematic match to the low mass particles. This article describes the HydroX concept, an idea to expand the dark matter sensitivity reach of large liquid xenon detectors by adding hydrogen to the liquid xenon. We discuss the nature of signal generation in liquid xenon to argue that the signal produced at the interaction site by a dark matter–hydrogen interaction could be significantly enhanced over the same interaction on xenon, increasing the sensitivity to the lightest particles. We discuss the technical implications of adding hydrogen to a xenon detector, as well as some background considerations. Finally, we make projections as to the potential sensitivity of a HydroX implementation and discuss next steps.

Experimental particle physics↗

HydroX, a light dark matter search with hydrogen-doped liquid xenon time projection chambers

Experimental efforts searching for dark matter particles over the last few decades have ruled out many candidates led by the new generation of tonne-scale liquid xenon. For light dark matter, hydrogen could be a better target than xenon as it would offer a better kinematic match to the low mass particles. This article describes the HydroX concept, an idea to expand the dark matter sensitivity reach of large liquid xenon detectors by adding hydrogen to the liquid xenon. We discuss the nature of signal generation in liquid xenon to argue that the signal produced at the interaction site by a dark matter–hydrogen interaction could be significantly enhanced over the same interaction on xenon, increasing the sensitivity to the lightest particles. We discuss the technical implications of adding hydrogen to a xenon detector, as well as some background considerations. Finally, we make projections as to the potential sensitivity of a HydroX implementation and discuss next steps.

Lippincott, W. H. [UC, Santa Barbara] (ORCID:00000↗

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

Snowmass2021 cosmic frontier white paper: Ultraheavy particle dark matter

We outline the unique opportunities and challenges in the search for "ultraheavy" dark matter candidates with masses between roughly 10 TeV and the Planck scale $m_{\rm pl} ≈ 10^{16}$ TeV. This mass range presents a wide and relatively unexplored dark matter parameter space, with a rich space of possible models and cosmic histories. We emphasize that both current detectors and new, targeted search techniques, via both direct and indirect detection, are poised to contribute to searches for ultraheavy particle dark matter in the coming decade. We highlight the need for new developments in this space, including new analyses of current and imminent direct and indirect experiments targeting ultraheavy dark matter and development of new, ultra-sensitive detector technologies like next-generation liquid noble detectors, neutrino experiments, and specialized quantum sensing techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning for single-ended event reconstruction in PROSPECT experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, was a segmented antineutrino detector that successfully operated at the High Flux Isotope Reactor in Oak Ridge, TN, during its 2018 run. Despite challenges with photomultiplier tube base failures affecting some segments, innovative machine learning approaches were employed to perform position and energy reconstruction, and particle classification. This work highlights the effectiveness of convolutional neural networks and graph convolutional networks in enhancing data analysis. By leveraging these techniques, a 3.3% increase in effective statistics was achieved compared to traditional methods, showcasing their potential to improve analysis performance. Furthermore, these machine learning methodologies offer promising applications for other segmented particle detectors, underscoring their versatility and impact.

47 OTHER INSTRUMENTATION↗

Status of Measuring Cross Sections of Hadrons on Argon with ProtoDUNE-SP

ProtoDUNE Single-Phase is a 700-ton liquid argon detector operated in the CERN Neutrino Platform from 2018 to 2020. It is part of the Deep Underground Neutrino Experiment (DUNE), a long-baseline neutrino oscillation experiment with a 40 kT liquid argon far detector to be built at the Sanford Underground Research Facility and a near detector, with both argon and non-argon detector technologies, to be hosted at the Fermi National Accelerator Laboratory. A critical uncertainty to understand in the neutrino oscillation program of DUNE is the uncertainty on final state interactions, either reaction or elastic, of various hadrons on argon since the scattering of neutrino-induced hadrons off argon bias the hadron's measured energy. It can also prevent algorithms from identifying the hadron's particle type. Protons, kaons, and pions from the beam are especially important for the DUNE neutrino program as they represent common final state particles in neutrino interactions off a nucl eus. Therefore, ProtoDUNE is analyzing the test beam data to measure cross sections of pions, protons, and kaons on argon, aiming to tune parameters that model charged particle scattering off argon. This talk will discuss the data-taking program for ProtoDUNE and an overview of the status and results of measuring cross sections of pions, protons, and kaons on argon. It will conclude with a brief overview of how these measurements can be used for future liquid argon neutrino detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗