Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Carbon nanotube scanning probe for imaging in aqueous environment

Carbon nanotubes (CNTs) used as a probe for scanning probe microscopy has become one of the many potential usages of CNTs that is finding real applications in scientific research and industrial communities. It has been proposed that the unique mechanical buckling properties of the CNT would lessen the imaging force exerted on the sample and, thus, make CNT scanning probes ideal for imaging soft materials, including biological samples in liquid environments. The hydrophobic nature of the CNT graphitic sidewall is clearly chemically incompatible with the aqueous solution requirements in some biological imaging applications. In this paper, we present electron micrograph results demonstrating the instability of CNT scanning probes when submerged in aqueous solution. Moreover, we also introduce a novel approach to resolve this chemical incompatibility problem. By coating the CNT probe with ethylenediamine, thus rendering the CNT probe less hydrophobic, we demonstrate the liquid imaging capability of treated CNT probes. Experimental data for imaging in aqueous solutions are presented, which include an ultrathin Ir film and DNA molecules on a mica surface.

Microscopy, Atomic Force/methods↗

Medical and Scientific Evaluations aboard the KC-135. Microgravity-Compatible Flow Cytometer

A spaceflight-compatible flow cytometer would be useful for the diagnosis of astronaut illness during long duration spaceflight and for conducting in-flight research to evaluate the effects of microgravity on human physiology. Until recently, the primary limitations preventing the development of a spaceflight compatible flow cytometer have been largely mechanical. Standard commercially available flow cytometers are large, complex instruments that use high-energy lasers and require significant training to operate. Standard flow cytometers function by suspending the particles to be analyzed inside a sheath fluid for analysis. This requires the presence of several liters of sheath fluid for operation, and generates a corresponding amount of liquid hazardous waste. The particles are then passed through a flow cell which uses the fluid mechanical property of hydrodynamic focusing to place the cells in single-file (laminar flow) as they pass through a laser beam for scanning and evaluation. Many spaceflight experiments have demonstrated that fluid physics is dramatically altered in microgravity (MSF [Manned Space Flight] Fluid Physics Data Sheet-August 1997) and previous studies have shown that sheath-fluid based hydrodynamic focusing may also be altered during microgravity (Crucian et al, 2000). For these reasons it is likely that any spaceflight compatible design for a flow cytometer would abandon the sheath fluid requirement. The elimination of sheath fluid would remove both the problems of weight associated with large volumes of liquids as well as the large volume of liquid waste generated. It would also create the need for a method to create laminar particle flow distinct from the standard sheath-fluid based method. The spaceflight prototype instrument is based on a recently developed commercial flow cytometer possessing a novel flow cell design that creates single-particle laser scanning and evaluation without the need for sheath-fluid based hydrodynamic focusing. This instrument also possesses a number of design advances that make it conditionally microgravity compatible: it is highly miniaturized and lightweight, uses a low energy diode laser, has a small number of moving parts, does not use sheath fluid and does not generate significant liquid waste. Although possessing certain limitations, the commercial cytometer functions operationally like a standard bench top laboratory flow cytometer, aspirating liquid particle samples and generating histogram or dot-plot data in standard FCS file format. In its current configuration however, the cytometer is limited to three parameter/two-color capability (two color PMTs + forward scatter), does not allow compensation between colors, does not allow linear analysis and is operated by rather inflexible software with limited capabilities. This is due to the fact that the cytometer has been designed and marketed as an instrument specific to a few particular assays, not as a multipurpose cytometer.

Crucian, Brian↗

Testing Tensile and Shear Epoxy Strength at Cryogenic Temperatures

This paper covers cryogenic, tensile testing and research completed on a number of epoxies used in cryogenic applications. Epoxies are used in many different applications; however, this research focused on the use of epoxy used to bond MLI standoffs to cryogenic storage tanks and the loads imparted to the tank through the MLI. To conduct testing, samples were made from bare stainless steel, aluminum and primed aluminum. Testing involved slowly cooling test samples with liquid nitrogen then applying gradually increasing tensile loads to the epoxy. The testing evaluated the strength and durability of epoxies at cryogenic temperatures and serves as a base for future testing. The results of the tests showed that some epoxies withstood the harsh conditions while others failed. The two epoxies yielding the best results were Masterbond EP29LPSP and Scotch Weld 2216. For all metal surfaces tested, both epoxies had zero failures for up to 11.81 kg of mass.

multilayer insulation↗

Heat Loads Due to Small Penetrations in Multilayer Insulation Blankets

Abstract: This paper covers cryogenic, tensile testing and research completed on a number of epoxies used in cryogenic applications. Epoxies are used in many different applications; however, this research focused on the use of epoxy used to bond MLI standoffs to cryogenic storage tanks and the loads imparted to the tank through the MLI. To conduct testing, samples were made from bare stainless steel, aluminum and primed aluminum. Testing involved slowly cooling test samples with liquid nitrogen then applying gradually increasing tensile loads to the epoxy. The testing evaluated the strength and durability of epoxies at cryogenic temperatures and serves as a base for future testing. The results of the tests showed that some epoxies withstood the harsh conditions while others failed. The two epoxies yielding the best results were Masterbond EP29LPSP and Scotch Weld 2216. For all metal surfaces tested, both epoxies had zero failures for up to 11.81 kg of mass.

multilayer insulation↗

Testing Tensile and Shear Epoxy Strength at Cryogenic Temperatures

This paper covers cryogenic, tensile testing and research completed on a number of epoxies used in cryogenic applications. Epoxies are used in many different applications; however, this research focused on the use of epoxy used to bond MLI standoffs to cryogenic storage tanks and the loads imparted to the tank through the MLI. To conduct testing, samples were made from bare stainless steel, aluminum and primed aluminum. Testing involved slowly cooling test samples with liquid nitrogen then applying gradually increasing tensile loads to the epoxy. The testing evaluated the strength and durability of epoxies at cryogenic temperatures and serves as a base for future testing. The results of the tests showed that some epoxies withstood the harsh conditions while others failed. The two epoxies yielding the best results were Masterbond EP29LPSP and Scotch Weld 2216. For all metal surfaces tested, both epoxies had zero failures for up to 11.81 kg of mass..

epoxy↗

Developing a Hybrid Spacesuit Simulator as a Research Tool for Assessing Extravehicular Activity Relevant Workload

Conducting human tests in a pressurized spacesuit is limited by availability, cost, and manpower; however, pressurized spacesuits are not always needed depending on the objectives of testing, including the development and testing of new informatics capabilities. The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA is developing a Hybrid Spacesuit Simulator (HS3) to support testing and characterization of human performance during analog planetary exploration extravehicular activities (EVAs). The goal of HS3 is to create a low-cost, modular, and unpressurized spacesuit simulator as a research tool that provides relevant physical and cognitive workload approximations with EVA-like immersion. HS3 consists of a soft outer suit, thermal control, gloves, boots, helmet, and integrated bioinformatics and communications. Baseline HS3 assessments were performed during 3-hour EVA simulations in two different subjects (DEMO1 and DEMO2) that included traverses at variable resistances and geological sampling activities. Liquid cooling garment (LCG) temperature, mean skin temperature, heart rate, motion capture, and metabolic rate were collected during each 3-hour simulated EVA. During DEMO1 and DEMO2, baseline metabolic rates at rest were 836 ± 327 BTU/hr and 869 ± 207 BTU/hr and increased to 2124 ± 548 BTU/hr and 2269 ± 559 BTU/hr, respectively, during 500m traverse. Average inlet LCG temperatures were 29.57 ± 6.62 °C and 25.63 ± 6.48 °C for DEMO1 and DEMO2 with increased outlet LCG temperatures of 33.53 ± 6.62 °C and 29.21 ± 4.79 °C, respectively. Overall, HS3 will enable future studies to characterize EVA tasks, human performance, and test future EVA capabilities in analog test environments without the need for pressurized suited environments.

Monica Hew↗

Developing A Hybrid Spacesuit Simulator as A Research Tool for Assessing Extravehicular Activity Relevant Workload

Conducting human tests in a pressurized spacesuit is limited by availability, cost, and manpower; however, pressurized spacesuits are not always needed depending on the objectives of testing, including the development and testing of new informatics capabilities. The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA is developing a Hybrid Spacesuit Simulator (HS3) to support testing and characterization of human performance during analog planetary exploration extravehicular activities (EVAs). The goal of HS3 is to create a low-cost, modular, and unpressurized spacesuit simulator as a research tool that provides relevant physical and cognitive workload approximations with EVA-like immersion. HS3 consists of a soft outer suit, thermal control, gloves, boots, helmet, and integrated bioinformatics and communications. Baseline HS3 assessments were performed during 3-hour EVA simulations in two different subjects (DEMO1 and DEMO2) that included traverses at variable resistances and geological sampling activities. Liquid cooling garment (LCG) temperature, mean skin temperature, heart rate, motion capture, and metabolic rate were collected during each 3-hour simulated EVA. During DEMO1 and DEMO2, baseline metabolic rates at rest were 836 ± 327 BTU/hr and 869 ± 207 BTU/hr and increased to 2124 ± 548 BTU/hr and 2269 ± 559 BTU/hr, respectively, during 500m traverse. Average inlet LCG temperatures were 29.57 ± 6.62 °C and 25.63 ± 6.48 °C for DEMO1 and DEMO2 with increased outlet LCG temperatures of 33.53 ± 6.62 °C and 29.21 ± 4.79 °C, respectively. Overall, HS3 will enable future studies to characterize EVA tasks, human performance, and test future EVA capabilities in analog test environments without the need for pressurized suited environments.

Suit simulator↗

Automated Drug Identification for Urban Hospitals

Many urban hospitals are becoming overloaded with drug abuse cases requiring chemical analysis for identification of drugs. In this paper, the requirements for chemical analysis of body fluids for drugs are determined and a system model for automated drug analysis is selected. The system as modeled, would perform chemical preparation of samples, gas-liquid chromatographic separation of drugs in the chemically prepared samples, infrared spectrophotometric analysis of the drugs, and would utilize automatic data processing and control for drug identification. Requirements of cost, maintainability, reliability, flexibility, and operability are considered.

Shirley, Donna L.↗

Post-Flight Microbial Analysis of Samples from the International Space Station Water Recovery System and Oxygen Generation System

The Regenerative, Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS) includes the the Water Recovery System (WRS) and the Oxygen Generation System (OGS). The WRS consists of a Urine Processor Assembly (UPA) and Water Processor Assembly (WPA). This report describes microbial characterization of wastewater and surface samples collected from the WRS and OGS subsystems, returned to KSC, JSC, and MSFC on consecutive shuttle flights (STS-129 and STS-130) in 2009-10. STS-129 returned two filters that contained fluid samples from the WPA Waste Tank Orbital Recovery Unit (ORU), one from the waste tank and the other from the ISS humidity condensate. Direct count by microscopic enumeration revealed 8.38 x 104 cells per mL in the humidity condensate sample, but none of those cells were recoverable on solid agar media. In contrast, 3.32 x lOs cells per mL were measured from a surface swab of the WRS waste tank, including viable bacteria and fungi recovered after S12 days of incubation on solid agar media. Based on rDNA sequencing and phenotypic characterization, a fungus recovered from the filter was determined to be Lecythophora mutabilis. The bacterial isolate was identified by rDNA sequence data to be Methylobacterium radiotolerans. Additional UPA subsystem samples were returned on STS-130 for analysis. Both liquid and solid samples were collected from the Russian urine container (EDV), Distillation Assembly (DA) and Recycle Filter Tank Assembly (RFTA) for post-flight analysis. The bacterium Pseudomonas aeruginosa and fungus Chaetomium brasiliense were isolated from the EDV samples. No viable bacteria or fungi were recovered from RFTA brine samples (N= 6), but multiple samples (N = 11) from the DA and RFTA were found to contain fungal and bacterial cells. Many recovered cells have been identified to genus by rDNA sequencing and carbon source utilization profiling (BiOLOG Gen III). The presence of viable bacteria and fungi from WRS and OGS subsystems demonstrates the need for continued monitoring of ECLSS during future ISS operations and investigation of advanced antimicrobial controls.

Birmele, Michele N.↗

A high-efficiency acoustic chamber and the anomalous sample rotation

A high efficiency acoustic chamber for the levitation and manipulation of liquid or molten samples in a microgravity environment has been developed. The chamber uses two acoustic drivers that are mounted at opposite corners of the chamber; by driving these at the same frequency, with 18-deg phase shifts, an increase in force of a factor of 3-4 is obtainable relative to the force of a single-driver system that is operated at the same power level. This enhancement is due to the increased coupling between the sound driver and the chamber. An anomalous rotation is noted to be associated with the chamber; this is found to be eliminated by a physically as-yet inexplicable empirical solution.

Wang, Taylor G.↗

Determination of Meteorite Porosity Using Liquid Nitrogen

We introduce a new harmless method for porosity measurement suitable for meteorite samples. The method is a modification of the traditional Archimedean method based on immersion of the samples in a liquid medium like water or organic liquids. In our case we used liquid nitrogen for its chemically inert characteristics.

Kohout, T.↗

Simultaneous quantification of poly-dispersed anionic, amphoteric and nonionic surfactants in simulated wastewater samples using C18 high-performance liquid chromatography-quadrupole ion-trap mass spectrometry

This paper describes the development of a guantitative method for direct and simultaneous determination of three frequently encountered surfactants, amphoteric (cocoamphoacetate, CAA), anionic (sodium laureth sulfate, SLES), and nonionic (alcohol ethoxylate, AE) using a reversed-phase C18 HPLC coupled with an ESI ion-trap mass spectrometer (MS). Chemical composition, ionization characteristics and fragmentation pathways of the surfactants are presented. Positive ESI was effective for all three surfactants in agueous methanol buffered with ammonium acetate. The method enables rapid determinations in small sample volumes containing inorganic salts (up to 3.5 g L(-1)) and multiple classes of surfactants with high specificity by applying surfactant specific tandem mass spectrometric strategies. It has dynamic linear ranges of 2-60, 1.5-40, 0.8-56 mg L(-1) with R2 egual or greater than 0.999, 0.98 and 0.999 (10 microL injection) for CAA, SLES, and AE, respectively.

Chromatography, High Pressure Liquid/methods↗

Infrared Spectroscopy as a Chemical Fingerprinting Tool

Infrared (IR) spectroscopy is a powerful analytical tool in the chemical fingerprinting of materials. The technique is rapid, reproducible and usually non-invasive. With the appropriate accessories, the technique can be used to examine samples in either a solid, liquid or gas phase. Solid samples of varying sizes and shapes may be used, and with the addition of microscopic IR (microspectroscopy) capabilities, minute materials such as single fibers and threads may be examined. With the addition of appropriate software, microspectroscopy can be used for automated discrete point or compositional surface area mapping, with the latter providing a means to record changes in the chemical composition of a material surface over a defined area. Both aqueous and non-aqueous free-flowing solutions can be analyzed using appropriate IR techniques, as can viscous liquids such as heavy oils and greases. Due to the ability to characterize gaseous samples, IR spectroscopy can also be coupled with thermal processes such as thermogravimetric (TG) analyses to provide both thermal and chemical data in a single run. In this configuration, solids (or liquids) heated in a TG analyzer undergo decomposition, with the evolving gases directed into the IR spectrometer. Thus, information is provided on the thermal properties of a material and the order in which its chemical constituents are broken down during incremental heating. Specific examples of these varied applications will be cited, with data interpretation and method limitations further discussed.

Huff, Tim↗

Integration mockup and process material management system

Work to define and develop a full scale Space Station Freedom (SSF) mockup with the flexibility to evolve into future designs, to validate techniques for maintenance and logistics and verify human task allocations and support trade studies is described. This work began in early 1985 and ended in August, 1991. The mockups are presently being used at MSFC in Building 4755 as a technology and design testbed, as well as for public display. Micro Craft also began work on the Process Material Management System (PMMS) under this contract. The PMMS simulator was a sealed enclosure for testing to identify liquids, gaseous, particulate samples, and specimen including, urine, waste water, condensate, hazardous gases, surrogate gasses, liquids, and solids. The SSF would require many trade studies to validate techniques for maintenance and logistics and verify system task allocations; it was necessary to develop a full scale mockup which would be representative of current SSF design with the ease of changing those designs as the SSF design evolved and changed. The tasks defined for Micro Craft were to provide the personnel, services, tools, and materials for the SSF mockup which would consist of four modules, nodes, interior components, and part task mockups of MSFC responsible engineering systems. This included the Engineering Control and Life Support Systems (ECLSS) testbed. For the initial study, the mockups were low fidelity, soft mockups of graphics art bottle, and other low cost materials, which evolved into higher fidelity mockups as the R&D design evolved, by modifying or rebuilding, an important cost saving factor in the design process. We designed, fabricated, and maintained the full size mockup shells and support stands. The shells consisted of cylinders, end cones, rings, longerons, docking ports, crew airlocks, and windows. The ECLSS required a heavier cylinder to support the ECLSS systems test program. Details of this activity will be covered. Support stands were designed and built for each module to sufficiently move and rotate each module. Secondary structures such as floors, ceilings, bulkheads, standoffs, racks, etc. were developed and built.

Verble, Adas James, Jr.↗

Containerless electromagnetic levitation melting of Cu-Fe and Ag-Ni alloys

The feasibility of producing silver or copper alloys containing finely dispersed nickel or iron particles, respectively, by utilizing containerless electromagnetic levitation casting techniques was investigated. A levitation coil was designed to successfully levitate and melt a variety of alloys including Nb-Ge, Cu-Fe, Fe-C, and Ag-Ni. Samples of 70 Cu-30 Fe and 80 Ag-20 Ni (atomic %), prepared by mechanical pressing of the constituent powders, were levitated and heated either to the solid plus liquid range of the alloys or to the fully liquid region. The samples were then solidified by passing helium gas into the bell jar or they were dropped into a quenching oil. The structure of the samples which were heated to the solid plus liquid range consists of uniform distribution of Fe or Ni particle in their respective matrices. A considerable amount of entrapped gas bubbles were contained. Upon heating for longer periods or to higher temperatures, the bubbles coalesced and burst, causing the samples to become fragmented and usually fall out of the coil.

Abbaschian, G. J.↗

Application of New Partition Coefficients to Modeling Plagioclase

Previously, studies that determined the partition coefficient for an element, i, between plagioclase and the residual basaltic melt (Di plag) have been conducted using experimental conditions dissimilar from the Moon, and thus these values are not ideal for modeling plagioclase fractionation in a lunar system. However, recent work [1] has determined partition coefficients for plagioclase at lunar oxygen fugacities, and resulted in plagioclase with Anorthite contents ≥An90; these are significantly more calcic than plagioclase in previous studies, and the An content has a profound effect on partition coefficient values [2,3]. Plagioclase D-values, which are dependent on the An content of the crystal [e.g., 2-6], can be determined using published experimental data and the correlative An contents. Here, we examine new experimental data from [1] to ascertain their effect on the calculation of equilibrium liquids from Apollo 16 sample 60635,2. This sample is a coarse grained, subophitic impact melt composed of ~55% plagioclase laths with An94.4-98.7 [7,8], distinctly more calcic than of previous partition coefficient studies (e.g., [3-6, 9-10]). Sample 60635,2 is notable as having several plagioclase trace element analyses containing a negative Europium anomaly (-Eu) in the rare-earth element (REE) profile, rather than the typical positive Eu anomaly (+Eu) [7-8] (Fig. 1). The expected +Eu is due to the similarity in size and charge with Ca2+, thereby allowing Eu2+ to be easily taken up by the plagioclase crystal structure, in contrast to the remaining REE3+. Some 60635,2 plagioclase crystals only have +Eu REE profiles, some only have -Eu REE profiles, and some +Eu and -Eu analyses in different areas on a single crystal [7, 8]. Moreover, there does not seem to be any core-rim association with the +Eu or -Eu analyses, nor does there appear to be a correlation between the size, shape, or location of a particular crystal within the sample and the sign of its Eu anomaly, which suggests a complex evolution. In order to investigate this sample further, we can calculate the equilibrium liquids, but with An contents distinct from previous experimental studies, we must calculate the appropriate partition coefficients for each trace element analysis.

Fagan, A. L.↗