Understanding Power and Load Trade-offs in Active Wake Control
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Groundwater dependent ecosystems in areas with industrial and military land use are at risk of direct exposure to a wide range of contaminants, including PFAS chemicals. Glaciated terrain often has mixed high and low permeability sediments coupled with groundwater flow-through lake features. These hydrogeologic attributes create highly complex ‘source to seep’ dynamics that make spatiotemporal contaminant transport patterns difficult to predict. We investigated one such system in detail using a suite of heat-tracing and chemical methods. Numerous (n=57) preferential groundwater discharge zones (vertical flux rates ranging 0.2 to 3.2 m/d) were identified across the upper Quashnet River stream-wetland system in Mashpee, MA, USA, adjacent to an Air Force Base with several known PFAS source areas. Surface-water and groundwater samples were collected and analyzed (n=145) for precursors and terminal PFAS compounds between March and September 2022. Samples were collected at identified seeps along the Quashnet River (n=59), from wells upgradient from the stream-wetland system (n= 44), from contributing flow-through kettle lakes (n=8), and at multiple locations along the Quashnet River (n=34). Samples from seeps and wells had measured PFAS concentrations ranging from non-detect to approximate 3,500 ng/L (mean= 1,650 ng/L), and a range of deuterium excess values (3.2 to 15.9 per mil) indicative of varying degrees of groundwater-lake interaction prior to emergence at the discharge zones. Groundwater-lake interaction along flowpaths that sourced the sampled seeps was farther supported by significant correlations (p < 0.01) between deuterium excess and %PFAS precursors, and between %PFAS precursors and multiple terminal PFAS compounds (e.g., PFPeS, PFBS, PFHxS). However, some sampled seeps contributing groundwater to the stream-wetland system had much higher total PFAS concentrations (>1000 ng/L) than the upgradient kettle lakes, despite showing lake (evaporative) isotopic signatures, indicating the potential for groundwater flowpath convergence at wetland discharge zones and the influence of lakebed PFAS precursor reactions. PFAS compounds and water isotopic composition at sampled multilevel groundwater wells, rivers, lakes, and seeps suggest that a complex mixture of source groundwater and flowpath characteristics are responsible for diverse observed PFAS mixtures at preferential discharge zones across the stream-wetland system. Further, total PFAS loading patterns to the Quashnet River via groundwater discharge remained remarkably similar from winter to summer to fall conditions, despite a regional dry period in late summer 2022 with the upper river channel completely drying. This work addresses gaps in the existing PFAS literature by demonstrating the importance of subsurface fate and transport on PFAS compound concentrations in controlling contaminant mass loading in preferential groundwater discharge zones and presents a transferrable field toolkit for efficient characterization of spatially preferential PFAS transport dynamics.
This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.
A thyristor is a solid-state semiconductor switch made up of four alternating p and n type layers. When the switch is turned on by a small pulse, current can flow as long as the device stays on. When the voltage drops below the turn on level or the current reverses, the switch will turn off. Thyristors only allow current to flow in one direction. One of the benefits of a thyristor device is in its capacity to conduct large voltages with a small device and a small turn-on pulse requirement. Another distinguishing feature of thyristors compared to other semiconductor devices is that it can only be in the on or off state, there’s no in-between state for the device to exist within. These properties make thyristors very useful as switch devices, especially in applications where current flow is only needed in one direction and could potentially be damaging in the opposite direction. Currently, thyristors are most commonly used to control very high power loads and they are available commercially in many designs to control different amounts of current.
Shifting electric load from times of peak demand can be a key strategy to slow price growth as reducing peak demand avoids the cost of upgrading generation, transmission and distribution infrastructure. Utilities are releasing time-varying prices, such as time of use rates or dynamic prices, to incentivize grid-friendly load shifting. New dynamic price programs provide insight into the true cost of operating electricity grids and the potential economic benefits of load shifting. Program developers and device manufacturers need to understand the economic opportunities in terms of 1) the variation in prices across hours, days, and seasons; 2) the change in utility bills for customers who don’t shift load; and 3) the potential load shifted and economic value of different technologies if manufacturers or aggregators deploy price-responsive controls. This paper estimates possible impacts of dynamic price adoption and load shifting controls if customers paid the dynamic rate from one pilot program. Statistical analysis of historical prices identified annual and seasonal metrics as well as representative price curves for each circuit in the pilot. Simulations for residential technologies with price-responsive controls including unitary heat pump water heaters, central multifamily heat pump water heaters, heating & cooling + storage systems, and pool pumps estimated the potential impacts of highly dynamic prices both with and without load shifting controls. Results showed the potential to reduce electricity costs on representative days by 42-94% and reduce consumption during times of high electricity prices by 63-100% compared to baseline operation for those flex-friendly devices.
Incentive Based Demand Response (IBDR) program participation delivers financial benefits to the consumers and resiliency benefits to the electricity grid. Effectively participating in these programs as an industrial consumer requires bidding strategies that balance financial risk with operational constraints. Existing bidding tools tend not to fully incorporate stochastic IBDR event modeling, program specific baseline and payment/penalty calculations, or demand reduction process control schemes that account for the cascading impacts of shutdown in complex facilities. Here, this work presents an IBDR event simulator and risk-aware bidding framework tool integrating three key components: a flexible, parameterized demand response event generator that rigorously accounts for program structures and stochasticity, a demand response operational simulation model that generates explicit control strategies for load reduction, and a Monte Carlo simulator to evaluate financial risk for varied capacity bids. A case study at a wastewater treatment plant participating in PG&E's Capacity Bidding Program demonstrates the framework's utility. In the peak capacity price month of August, optimal bidding by the wastewater treatment plant nets a mean IBDR benefit of $101,000 (67% of the August electricity bill) with 0.4% probability of a financial loss. This framework enables industrial operators to make informed bidding decisions, negotiate better program terms with demand response load aggregators, and analyze energy flexibility investments at their facilities. Ultimately, this work reduces participation barriers in IBDR programs and supports the broader goal of enhancing grid reliability and renewable energy integration.
Transient broadening of the scrape-off layer (SOL) density profile can modify main-chamber first-wall particle fluxes and divertor loading, yet its control parameters remain debated between divertor-regime transitions, neutral dynamics and changes in cross-field transport. We investigate fueling-driven SOL density-profile evolution and post-fueling relaxation on MAST-Upgrade (MAST-U) in ohmic L-mode, using two otherwise similar double-null Conventional Divertor discharges (I p = 450 kA, B T = 0.33 T) with identical 50 ms low-field side gas puffs; the only intentional difference is the puff start time. Upstream Thomson scattering shows that both discharges develop a transient far-SOL density profile modification, expressed as an increased SOL-width metric λ n e and a far-SOL enhancement consistent with a shoulder-like signature. In the earlier-puff case, the SOL-width metric remains elevated after puff termination and the post-puff decay time scales are systematically longer across the analysed radii. Outer-target Langmuir probes indicate high-recycling conditions during the analysed window (few-eV T e with radially peaked j sat,∥ and q ∥ profiles, without signatures of deep detachment). The outer-divertor collisionality proxy Λ div is elevated in both cases and does not discriminate between the different post-puff persistence. The target-integrated ion flux proxy ∫ J sat dA evolves nearly identically in both discharges when aligned to the puff start. Taken together, these observations suggest that the late/post-puff upstream SOL evolution is not set by parallel exhaust to the outer targetalone and is more consistent with upstream cross-field redistribution, with a possible role for plasma–neutral coupling and fueling geometry.
The increasing penetration of renewable energy in California has intensified grid management challenges, exemplified by the “duck curve” and the resulting need for steep ramping and curtailment of renewables. To address these issues, dynamic electricity tariffs that vary in near-real time are being considered to incentivize customers to shift demand and support the grid. This study extends previous work on the bill impacts of such tariffs in the absence of load response by quantifying the system-level and customer impacts of load response based on customer price elasticity. Customer-level load response modeling was conducted using meter data from 411,000 customers across residential, commercial, and industrial sectors. Customer demand elasticity was estimated using literature-based values, with scenarios ranging from low to high elasticity, including an automation-enhanced scenario. Results indicate that universal adoption of, and response to, dynamic tariffs can significantly reduce peak net load (by 15%) and maximum ramping requirements (by 20%) with moderate elasticity, delivering demand response resources comparable to or exceeding current programs at all elasticity levels. Bill analysis shows that, when responding elastically to dynamic prices, most non-PV customers experience modest savings, while PV customers may see higher effective rates due to lower compensation for exports during low-price periods. Emissions analysis reveals a reduction in per-kWh emissions system-wide, with a total absolute load increase of 2% accompanied by a negligible absolute emissions increase. The study concludes that while dynamic tariffs offer substantial grid benefits, customer bill savings under modeled response behaviors may be too modest to drive widespread adoption without additional incentives or enabling technologies. Future research should model flexible loads and advanced control technologies with greater fidelity to better represent the potential opportunities of dynamic tariffs.
The primary objective of this project is to assess the techno-economic viability of hydropower resources with supplementary investments, including microgrid controllers, storage solutions, load banks, additional generation like diesel generators, communication links, and transmission infrastructure. The aim is to enable these systems to operate autonomously (in islanded mode) and ensure grid resiliency during and after wildfire events. The project seeks to establish a comprehensive framework for setting up hydropower-based microgrids, from risk estimation to final investment decisions. These microgrids can provide critical support during emergencies and offer additional grid stability and revenue opportunities during regular operations and other system contingencies.
Linear approximation commonly used in solving alternating-current optimal power flow (AC-OPF) simplifies the system models but incurs accumulated voltage errors in large power networks. Such errors will make the primal-dual type gradient algorithms converge to solutions with voltage violation. In this paper, we improve a recent hierarchical OPF algorithm that rested on primal-dual gradients evaluated with a linearized distribution power flow model. Specifically, we propose a more accurate gradient evaluation method based on an unbalanced three-phase nonlinear distribution power flow model to mitigate the errors arising from linearization. The resultant gradients feature a blocked structure that enables our development of an improved hierarchical primal-dual algorithm to solve the OPF problem. Numerical results on the IEEE 123-bus test feeder and a 4,518-node test feeder show that the proposed method can enhance voltage safety at comparable computational efficiency with the linearized algorithm.
Battery energy storage systems (BESSs) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various critical services to the power grid. This paper presents the real-world experience of using a megawatt-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to restore a regional power system. To demonstrate this, we carry out power-hardware-in-the-loop experiments integrating an actual GFL- or GFM-controlled BESS and a load bank. Both the simulation and experimental results presented in this paper show the different roles of GFL- or GFM-controlled BESS in power system black starts. The results provide further insight for system operators on how GFL- or GFM-controlled BESS can enhance grid stability and how an ROR hydropower plant can be converted into a black-start-capable unit with the support of a small-capacity BESS. The results show that an ROR hydropower plant combined with a BESS has the potential of becoming one of enabling elements to perform bottom-up black-start schemes as opposed to conventional bottom-down method, thus enhancing the system resiliency and robustness.
Building porous donor−acceptor networks based on host−guest interactions in metal organic frameworks (MOFs) provides unique opportunities for tuning charge separation in highly tailorable materials. Here we focus on installing electron-rich porphyrins and electron-deficient fullerene derivatives in the PCN-222 MOF using a solvent assisted ligand insertion (SALI) method. The fullerene is primarily bound in the large pore, where it is subject to distinct dielectric environments through dimethylformamide (DMF) and 1,4-dioxane solvent exchange. Following photoexcitation, sub-picosecond charge transfer involving initial exciplex population is observed, with different charge recombination pathways and lifetimes depending on solvent polarity through modulation of charge-transfer state energies. While the 1,4-dioxane environment yields charge recombination within 1 ns via local fullerene and porphyrin triplet state population, DMF results in charge recombination directly to the ground state on much longer time scales, including some lifetime components in the microsecond range. Fullerene loading influences these kinetics, and the potential for charge delocalization due to fullerene aggregation within the pores is evaluated by using molecular dynamics simulations.
This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.
Significant building energy savings are realized through heating, ventilation, and air conditioning (HVAC) setpoint adjustment and daylighting control. Workplace charging (WPC) enables colocation of electric vehicles (EVs) with office building loads. We proposed managing energy use of workplace EV charging and the office building and determined the number of EVs that building energy savings can facilitate charging. We simulated building energy savings in typical medium offices in Chicago IL, Baltimore MD, and Houston TX, spanning three US climate regions. Considering the EV hosting capacity of the saved building energy and travel patterns of roundtrip commuting, we minimized EV charging costs under time-of-use electricity pricing. Managed WPC can reduce charging electricity bills compared to first-come, first-served charging. The ratio of EVs to chargers, the coincident period of commuters’ dwell time and lower electricity prices, and the number of EVs in the office impacted the economic benefits achieved through charging management.
Proton exchange membrane water electrolyzers rely on relatively expensive Ir-based catalysts for efficient and durable hydrogen production. To reduce system costs, Ir loadings can be reduced if performance and durability are maintained. Sputter deposition is a readily scalable method to synthesize uniform, low-loading catalyst layers with controlled composition. A catalyst applied directly to the porous transport layer can have advantages for performance, manufacturing simplicity, and catalyst recovery. Suitable porous transport layer porosity can minimize activity losses when reducing loadings. Here, methods are presented to deposit metallic Ir as well as amorphous and rutile Ir oxides. The activity and durability of these materials in the porous transport electrode architecture is evaluated. The metallic and amorphous forms have better initial activity, however, operation at 3 A cm −2 with 0.1 mg Ir cm −2 shows that only rutile IrO 2 maintains performance beyond 100 h with a 50 mV improvement after 700 h. A >10x reduced dissolution rate is shown for rutile IrO 2 . With a low-porosity transport layer and 0.4 mg Ir cm −2 , a steady-state voltage decay rate of 6 µV h −1 is achieved. The results demonstrate that sputter-deposited rutile IrO 2 porous transport electrodes with low Ir loading can be operated at high current density to reduce hydrogen production costs.
Standalone microgrids often experience unbalanced loading and faults, which can cause grid-forming control designed for balanced conditions to produce oscillatory responses. To address this issue, a compact time-domain transformation appropriate for inverter control is proposed, allowing the conversion of unbalanced three-phase signals to positive and negative synchronous reference frames. This transformation supports the development of a grid-forming control with fault ride-through, featuring frequency and voltage droop controllers and nested current and voltage control loops that seamlessly integrate an enhanced current limiter. The effectiveness of the proposed control and transformation is demonstrated through analytical results and electromagnetic transient simulation.
To enhance the mechanical properties of carbon fiber‐reinforced polymer composites, a physicochemical scaffold is designed incorporating microscopically architected chemically reactive nanofibers that act as a multiscale bridge between the carbon fibers and the matrix. Thermally activated nanofibers leverage their morphologically driven mechanochemical properties to form covalent bonds with adjacent polymer molecules, creating a co‐continuous network that dramatically enhances fiber‐matrix load transfer. By meticulously controlling the nanofiber architecture through variable surface area, functional group availability, and polymer chain alignment effects, the extent of covalent bonding between nanofibers and the matrix is manipulated ultimately resulting in improved carbon fiber‐matrix adhesion. Further, the concept was validated using polyacrylonitrile nanofibers within an acrylonitrile butadiene styrene matrix in a discontinuous carbon fiber‐reinforced composite system. Nanomechanical studies using atomic force microscopy and low‐field nuclear magnetic resonance spectroscopy confirmed immobilized, chemically transferred, and ordered nanostructures at the interphase. The resulting composites demonstrated ≈56% and ≈175% improvements in tensile strength and toughness, respectively, compared to composites without nanofiber. Comprehensive thermal, rheological, and X‐ray scattering analyses, along side all‐atomic molecular dynamics simulations, revealed the fundamental mechanisms behind these improvements in mechanical behavior. The versatility and efficacy of the approach have the potential to address longstanding interphase challenges in the composite industry.
With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.