Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Efficiency and temperature dependence of water removal by membrane dryers

The vapor pressure of water in equilibrium with sorption sites within a Nafion membrane is given by log P(WN) = -3580/T + 10.01, where P(WN) is expressed in Torr and T is the membrane temperature, in kelvin. The efficiency of dryers based on selective permeation of water through Nafion can thus be enhanced by cooling the membrane. Residual water in effluents exceeds equilibrium levels if insufficient time is allowed for water to diffuse to the membrane surface as gas passes through the dryer. For tubular configurations, this limitation can be avoided if L > or = Fc(10(3.8)/120 pi D), where L is the length of the tubular membrane, in centimeters, Fc is the gas flow rate, in mL/ min, and D is the diffusion coefficient for water in the carrier gas at the operating temperature of the dryer, in cm2/s. An efficient dryer that at room temperature dries gas to a dew point of -61 degrees C is described; the same dryer maintained at 0 degrees C yields a dew point of -80 degrees C and removes water as effectively as Mg(ClO4)2 or a dry ice/acetone slush. The use of Nafion membranes to construct devices capable of delivering gas streams with low but precisely controlled humidities is discussed.

Non-NASA Center↗

Extreme High and Low Temperature Operation of the Silicon-On-Insulator Type CHT-OPA Operational Amplifier

A new operational amplifier chip based on silicon-on-insulator technology was evaluated for potential use in extreme temperature environments. The CHT-OPA device is a low power, precision operational amplifier with rail-to-rail output swing capability, and it is rated for operation between -55 C and +225 C. A unity gain inverting circuit was constructed utilizing the CHT-OPA chip and a few passive components. The circuit was evaluated in the temperature range from -190 C to +200 C in terms of signal gain and phase shift, and supply current. The investigations were carried out to determine suitability of this device for use in space exploration missions and aeronautic applications under wide temperature incursion. Re-restart capability at extreme temperatures, i.e. power switched on while the device was soaked at extreme temperatures, was also investigated. In addition, the effects of thermal cycling under a wide temperature range on the operation of this high performance amplifier were determined. The results from this work indicate that this silicon-on-insulator amplifier chip maintained very good operation between +200 C and -190 C. The limited thermal cycling had no effect on the performance of the amplifier, and it was able to re-start at both -190 C and +200 C. In addition, no physical degradation or packaging damage was introduced due to either extreme temperature exposure or thermal cycling. The good performance demonstrated by this silicon-on-insulator operational amplifier renders it a potential candidate for use in space exploration missions or other environments under extreme temperatures. Additional and more comprehensive characterization is, however, required to establish the reliability and suitability of such devices for long term use in extreme temperature applications.

Patterson, Richard↗

Fused Bead Analysis of Diogenite Meteorites

Bulk rock chemistry is an essential dataset in meteoritics and planetary science [1]. A common method used to obtain the bulk chemistry of meteorites is ICP-MS. While the accuracy, precision and low detection limits of this process are advantageous [2], the sample size used for analysis (approx.70 mg) can be a problem in a field where small and finite samples are the norm. Fused bead analysis is another bulk rock analytical technique that has been used in meteoritics [3]. This technique involves forming a glass bead from ~10 mg of sample and measuring its chemistry using a defocused beam on a microprobe. Though the ICP-MS has lower detection limits than the microprobe, the fused bead method destroys a much smaller sample of the meteorite. Fused bead analysis was initially designed for samples with near-eutectic compositions and low viscosities. Melts generated of this type homogenize at relatively low temperatures and produce primary melts near the sample s bulk composition [3]. The application of fused bead analysis to samples with noneutectic melt compositions has not been validated. The purpose of this study is to test if fused bead analysis can accurately determine the bulk rock chemistry of non-eutectic melt composition meteorites. To determine this, we conduct two examinations of the fused bead. First, we compare ICP-MS and fused bead results of the same samples using statistical analysis. Secondly, we inspect the beads for the presence of crystals and chemical heterogeneity. The presence of either of these would indicate incomplete melting and quenching of the bead.

Mittlefehldt, D.W.↗

NASA SBIR Subtopic S2.04 "Advanced Optical Components"

The primary purpose of this subtopic is to develop and demonstrate technologies to manufacture ultra-low-cost precision optical systems for very large x-ray, UV/optical or infrared telescopes. Potential solutions include but are not limited to direct precision machining, rapid optical fabrication, slumping or replication technologies to manufacture 1 to 2 meter (or larger) precision quality mirror or lens segments (either normal incidence for uv/optical/infrared or grazing incidence for x-ray). An additional key enabling technology for UV/optical telescopes is a broadband (from 100 nm to 2500 nm) high-reflectivity mirror coating with extremely uniform amplitude and polarization properties which can be deposited on 1 to 3 meter class mirror.

Stahl, H. Philip↗

Performance of the Micropower Voltage Reference ADR3430 Under Extreme Temperatures

Electronic systems designed for use in space exploration systems are expected to be exposed to harsh temperatures. For example, operation at cryogenic temperatures is anticipated in space missions such as polar craters of the moon (-223 C), James Webb Space Telescope (-236 C), Mars (-140 C), Europa (-223 C), Titan (-178 C), and other deep space probes away from the sun. Similarly, rovers and landers on the lunar surface, and deep space probes intended for the exploration of Venus are expected to encounter high temperature extremes. Electronics capable of operation under extreme temperatures would not only meet the requirements of future spacebased systems, but would also contribute to enhancing efficiency and improving reliability of these systems through the elimination of the thermal control elements that present electronics need for proper operation under the harsh environment of space. In this work, the performance of a micropower, high accuracy voltage reference was evaluated over a wide temperature range. The Analog Devices ADR3430 chip uses a patented voltage reference architecture to achieve high accuracy, low temperature coefficient, and low noise in a CMOS process [1]. The device combines two voltages of opposite temperature coefficients to create an output voltage that is almost independent of ambient temperature. It is rated for the industrial temperature range of -40 C to +125 C, and is ideal for use in low power precision data acquisition systems and in battery-powered devices. Table 1 shows some of the manufacturer s device specifications.

Patterson, Richard L.↗

Progress on a Multichannel, Dual-Mixer Stability Analyzer

Several documents describe aspects of the continuing development of a multichannel, dual-mixer system for simultaneous characterization of the instabilities of multiple precise, low-noise oscillators. One of the oscillators would be deemed to be a reference oscillator, its frequency would be offset by an amount (100 Hz) much greater than the desired data rate, and each of the other oscillators would be compared with the frequency-offset signal by operation of a combination of hardware and software. A high-rate time-tag counter would collect zero-crossing times of the approximately equal 100-Hz beat notes. The system would effect a combination of interpolation and averaging to process the time tags into low-rate phase residuals at the desired grid times. Circuitry that has been developed since the cited prior article includes an eight-channel timer board to replace an obsolete commercial time-tag counter, plus a custom offset generator, cleanup loop, distribution amplifier, zero-crossing detector, and frequency divider.

Kirk, Albert↗

Helicopter Flight Test of a Compact, Real-Time 3-D Flash Lidar for Imaging Hazardous Terrain During Planetary Landing

A second generation, compact, real-time, air-cooled 3-D imaging Flash Lidar sensor system, developed from a number of cutting-edge components from industry and NASA, is lab characterized and helicopter flight tested under the Autonomous Precision Landing and Hazard Detection and Avoidance Technology (ALHAT) project. The ALHAT project is seeking to develop a guidance, navigation, and control (GN&C) and sensing system based on lidar technology capable of enabling safe, precise crewed or robotic landings in challenging terrain on planetary bodies under any ambient lighting conditions. The Flash Lidar incorporates a 3-D imaging video camera based on Indium-Gallium-Arsenide Avalanche Photo Diode and novel micro-electronic technology for a 128 x 128 pixel array operating at a video rate of 20 Hz, a high pulse-energy 1.06 μm Neodymium-doped: Yttrium Aluminum Garnet (Nd:YAG) laser, a remote laser safety termination system, high performance transmitter and receiver optics with one and five degrees field-of-view (FOV), enhanced onboard thermal control, as well as a compact and self-contained suite of support electronics housed in a single box and built around a PC-104 architecture to enable autonomous operations. The Flash Lidar was developed and then characterized at two NASA-Langley Research Center (LaRC) outdoor laser test range facilities both statically and dynamically, integrated with other ALHAT GN&C subsystems from partner organizations, and installed onto a Bell UH-1H Iroquois "Huey" helicopter at LaRC. The integrated system was flight tested at the NASA-Kennedy Space Center (KSC) on simulated lunar approach to a custom hazard field consisting of rocks, craters, hazardous slopes, and safe-sites near the Shuttle Landing Facility runway starting at slant ranges of 750 m. In order to evaluate different methods of achieving hazard detection, the lidar, in conjunction with the ALHAT hazard detection and GN&C system, operates in both a narrow 1deg FOV raster-scanning mode in which successive, gimbaled images of the hazard field are mosaicked together as well as in a wider, 4.85deg FOV staring mode in which digital magnification, via a novel 3-D superresolution technique, is used to effectively achieve the same spatial precision attained with the more narrow FOV optics. The lidar generates calibrated and corrected 3-D range images of the hazard field in real-time and passes them to the ALHAT Hazard Detection System (HDS) which stitches the images together to generate on-the-fly Digital Elevation Maps (DEM's) and identifies hazards and safe-landing sites which the ALHAT GN&C system can then use to guide the host vehicle to a safe landing on the selected site. Results indicate that, for the KSC hazard field, the lidar operational range extends from 100m to 1.35 km for a 30 degree line-of-sight angle and a range precision as low as 8 cm which permits hazards as small as 25 cm to be identified. Based on the Flash Lidar images, the HDS correctly found and reported safe sites in near-real-time during several of the flights. A follow-on field test, planned for 2013, seeks to complete the closing of the GN&C loop for fully-autonomous operations on-board the Morpheus robotic, rocket-powered, free-flyer test bed in which the ALHAT system would scan the KSC hazard field (which was vetted during the present testing) and command the vehicle to landing on one of the selected safe sites.

Roback, VIncent E.↗

Drill Embedded Nanosensors For Planetary Subsurface Exploration

We have developed a carbon nanotube (CNT) sensor for water vapor detection under Martian Conditions and the miniaturized electronics can be embedded in the drill bit for collecting sensor data and transmit it to a computer wirelessly.This capability will enable the real time measurement of ice during drilling. With this real time and in-situ measurement, subsurface ice detection can be easy, fast, precise and low cost.

Planetary exploration↗

A Survey of Eight Hot Jupiters in Secondary Eclipse Using WIRCam at CFHT

We present near-infrared high-precision photometry for eight transiting hot Jupiters observed during their predicted secondary eclipses. Our observations were carried out using the staring mode of the WIRCam instrument on the Canada-France-Hawaii Telescope (CFHT).We present the observing strategies and data reduction methods which delivered time series photometry with statistical photometric precision as low as 0.11 percent. We performed a Bayesian analysis to model the eclipse parameters and systematics simultaneously. The measured planet-to-star flux ratios allowed us to constrain the thermal emission from the day side of these hot Jupiters, as we derived the planet brightness temperatures. Our results combined with previously observed eclipses reveal an excess in the brightness temperatures relative to the blackbody prediction for the equilibrium temperatures of the planets for a wide range of heat redistribution factors. We find a trend that this excess appears to be larger for planets with lower equilibrium temperatures. This may imply some additional sources of radiation, such as reflected light from the host star and/or thermal emission from residual internal heat from the formation of the planet.

Bayesian Analysis↗

Use of an Internal Mercury-Argon Lamp for the Calibration of Raman Frequency in Large Raman Images of Astromaterials

Raman imaging is an emerging tool for the analysis of meteorites, as it is capable of describing mineralogy, carbon composition/speciation, and crystal orientation all within a petrographic context. Adequately examining the heterogeneous composition of a meteorite, while maintaining low laser powers needed to prevent damage to meteorite mineralogy and organics, often requires the collection of large Raman images with long collection times on the timescale of days. However, the frequency calibration of the Raman instrument/spectrometer drifts on long timescales resulting in low frequency precision for the Raman spectra comprising a large Raman image. This decrease in frequency precision can compromise the analysis of geological markers that can provide important information on a meteorite sample. We examine, in detail, the change in bandwidth and frequency of the Raman bands and Hg-Ar emission lines in our Raman images as a function of time and laboratory temperature. To overcome the drift in calibration, we utilize a commercial WITec Raman instrument with an internal Hg-Ar calibration lamp to individually calibrate each spectrum in the Raman image. Our instrument, known as “Ratatoskr”, uses a beam splitter in place of the customary mirror to facilitate collection of Hg-Ar calibration lines concurrent with Raman spectra. We show that using the internal calibration we can improve the frequency precision for the spectra in our Raman images from ~±0.15 cm(exp -1) to ~±0.05 cm(exp -1) for Raman spectra collected over multiple days. This is important as it improves measurements of mineral chemistry, latent strain, and other features that are dependent upon accurate peak position determination. We also examine the spectral signal-to-noise ratio needed to minimize the frequency error when fitting bands to Gaussian/Lorentzian profiles. We then use our results to suggest a general method for calibrating the frequency of Raman spectra in large Raman images.

Jakubek, Ryan S.↗

Use of an Internal Mercury-Argon Lamp for the Calibration of Raman Frequency in Large Raman Images of Astromaterials

Raman imaging is an emerging tool for the analysis of meteorites, as it is capable of describing the mineralogy and organics within a petrographic context. Adequately examining the heterogeneous composition of a meteorite often requires the collection of large Raman images with long collection times on the time-scale of days. However, the frequency calibration of the Raman instrument/spectrometer drifts on long timescales resulting in low frequency precision for the Raman spectra comprising a large Raman image. Here we utilize a Hg-Ar calibration lamp integrated into our Raman microscope to calibrate the Raman spectra within a Raman image. We characterize this method of calibration in detail.

Ryan S. Jakubek↗

Corrigendum to: Volatiles in Lunar Felsite Clasts: Impact-related Delivery of Hydrous Material to an Ancient Dry Lunar Crust

Hydrous components were measured in nominally anhydrous minerals, primarily lunar feldspar, and reported by Simon et al. (2020). In the feldspar mineral structure, these components are contained in the form of OH, H2O, and/or NH4+molecules (Johnson, 2006 and references therein). The advantages of the ion microprobe technique employed by Simon et al. (2020) include high spatial resolution, apparent insensitivity to crystal orientation, high precision, and low detection limits, but unlike complementary spectroscopy techniques (i.e., FTIR) they preclude assignment of molecular species(Mosenfelder et al. 2015). Convention in the lunar sample community is to report major elemental abundances and hydrogen as oxides, H2O is the oxide for H. This convention was not followed by Simon et al. (2020), but rather the measured hydrogen component was reported as H to avoid the appearance of assigning the measured hydrogen concentration to a specific molecular species. The speciation of the hydrous component in terrestrial feldspars varies predominantly between OH and H2O, with no apparent correlation to feldspar composition, and only slight correlation to volcanic-to-plutonic igneous rock type (Johnson and Rossman, 2004).

J. I. Simon↗

Precision of Spacecraft Doppler Tracking at Low Signal-to-Noise Ratios

The signal-to-noise ratio received at Earth is typically larger than 10 dB-Hz for radio tracking of a spacecraft in deep space, allowing a phase-locked loop to execute reliable carrier tracking. Recently, missions have been proposed to utilize low-gain antennas for Doppler tracking where the signal-to-noise ratio may be at the single-digit (dB-Hz) level. In this work, we discuss spacecraft Doppler tracking at these low signal-to-noise ratios through an analysis of thermal noise on the radio link, results from ground testing with the Deep Space Network, and demonstrations with an active spacecraft. We show that by utilizing an open-loop receiver to capture the carrier signal and by applying post-processing techniques, radio data with the signal-to-noise ratio as low as 4 dB-Hz can be used to derive Doppler data with precision sufficient for tracking a spacecraft in deep space.

D. R. Buccino↗

The NANOGrav 12.5 yr Data Set: The Frequency Dependence of Pulse Jitter in Precision Millisecond Pulsars

Low-frequency gravitational-wave experiments require the highest timing precision from an array of the moststable millisecond pulsars. Several known sources of noise on short timescales in single radio pulsar observationsare well described by a simple model of three components: template fitting from a finite signal-to-noise ratio, pulsephase/amplitude jitter from single-pulse stochasticity, and scintillation errors from short-timescale interstellarscattering variations. Currently template-fitting errors dominate, but as radio telescopes push toward higher signalto-noise ratios, jitter becomes the next dominant term for most millisecond pulsars. Understanding the statistics ofjitter becomes crucial for properly characterizing arrival time uncertainties. We characterize the radio frequencydependence of jitter using data on 48 pulsars in the North American Nanohertz Observatory for GravitationalWaves timing program. We detect significant jitter in 43 of the pulsars and test several functional forms for itsfrequency dependence; we find significant frequency dependence for 30 pulsars. We find moderate correlations ofrms jitter with pulse width (R = 0.62) and number of profile components (R = 0.40); the single-pulse rms jitter istypically 1% of pulse phase. The average frequency dependence for all pulsars using a power-law model hasindex 0.42. We investigate the jitter variations for the interpulse of PSR B1937+21 and find no significantdeviations from the main pulse rms jitter. We also test the time variation of jitter in two pulsars and find thatsystematics likely bias the results for high-precision pulsars. Pulsar timing array analyses must properly modeljitter as a significant component of the noise within the detector.

Lam, M. T.↗

Low noise buffer amplifiers and buffered phase comparators for precise time and frequency measurement and distribution

Extremely low noise, high performance, wideband buffer amplifiers and buffered phase comparators were developed. These buffer amplifiers are designed to distribute reference frequencies from 30 KHz to 45 MHz from a hydrogen maser without degrading the hydrogen maser's performance. The buffered phase comparators are designed to intercompare the phase of state of the art hydrogen masers without adding any significant measurement system noise. These devices have a 27 femtosecond phase stability floor and are stable to better than one picosecond for long periods of time. Their temperature coefficient is less than one picosecond per degree C, and they have shown virtually no voltage coefficients.

Eichinger, R. A.↗

High Precision and Real Time Tracking of Low Earth Orbiters With GPS: Case Studies With TOPEX/POSEIDON and EUVE

TOPEX/POSEIDON carries a dual-frequency 6 channel GPS receiver while EUVE has a 12 channel single frequency receiver. Flying at an altitude of 1334 km, TOPEX/POSEIDON performs precise ocean altimetry, which demands the highest possible accuracy in determining the radial orbit component in post-processing. Radial RMS accuracies of about 2 cm were realized using reduced dynamic tracking techniques. In this approach, orbit errors due to force are substantially reduced by exploiting the geometric strength of GPS to solve for a set of stochastic forces. On EUVE, the emphasis was on evaluating real time positioning techniques with a single frequency receiver. The capability for real time 3D accuracies of 15 m in the presence of Selective Availability was shown. This was validated by comparing to a post-processed differential GPS truth orbit believed accurate to about 1 m.!.

Tracking low-Earth orbiters↗

Orbit Determination System for Low Earth Orbit Satellites

The IAI/MBT Precise Orbit Determination system for Low Earth Orbit satellites is presented. The system is based on GPS pesudorange and carrier phase measurements and implements the Reduced Dynamics method. The GPS measurements model, the dynamic model, and the least squares orbit determination are discussed. Results are shown for data from the CHAMP satellite and for simulated data from the ROKAR GPS receiver. In both cases the one sigma 3D position and velocity accuracy is about 0.2 m and 0.5 mm/sec respectively.

Elisha, Yossi↗

Electrodeposition of Low Stress Nickel Phosphorous Alloys for Precision Component Fabrication

Nickel alloys are favored for electroforming precision components. Nickel phosphorous and nickel cobalt phosphorous are studied in this work. A completely new and innovative electrolytic process eliminates the fumes present in electroless processes and is suitable for electroforming nickel phosphorous and nickel cobalt phosphorous alloys to any desirable thickness, using soluble anodes, without stripping of tanks. Solutions show excellent performance for extended throughput. Properties include, cleaner low temperature operation (40 - 45 C), high Faradaic efficiency, low stress, Rockwell C 52 - 54 hardness and as much as 2000 N per square millimeter tensile strength. Performance is compared to nickel and nickel cobalt electroforming.

Engelhaupt, Darell↗