Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low temperature heat release”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Pressure effects on reactivity and extinction of n -dodecane diffusion cool flame

Low-temperature combustion at high pressure has gained increasing interest owing to the growing demand for clean and efficient propulsion and energy systems. In particular, cool flame structure, extinction limits, and fuel reactivities at high pressure are critical in affecting the engine performance at near-limit conditions. Here, this paper investigates the effects of pressure on the cool flame extinction limit, structure, radical index, reactivity, and oxygen concentration dependence by experiments, analysis, and modeling. A large n-alkane, namely n-dodecane (n C 12 H 26 ), is selected to study its diffusion cool flame dynamics and reactivity in a high-pressure counterflow burner up to 10 atm. The experimental results show that higher pressure increases the cool flame extinction strain rates, and that the pressure-weighted extinction strain rate (aP) is proportional to the square of pressure, P 2 . A scaling analysis explains the relationship between the dependence of flame structure, heat release rate, and pressure-weighted cool flame strain rate on pressure. Furthermore, radical indexes at different pressures are measured by isolating the thermal and transport effects from the chemical contribution to diffusion cool flame extinction. The radical index clearly shows that the low-temperature reactivity increases with pressure. In addition, due to the critical role of multiple oxygen addition reactions in low-temperature chemistry, the relationship between the cool flame extinction limit and the oxygen concentration is explored. It is found that the cool flame extinction limits are proportional to the n th power of the oxygen concentration, [O 2 ] n , and increasing pressure leads to stronger extinction limit dependence (larger n) on the oxygen concentration. The present experiment and detailed kinetic analysis show clearly that increasing pressure promotes the low-temperature chemistry including the oxygen addition reactions, while the scaling analysis explains well the experimental results.

33 ADVANCED PROPULSION SYSTEMS↗

Compartment Fire Modeling of a Crew Cabin in 1-g and Lunar-g

A fire inside a spacecraft poses one of the greatest dangers to the crew and mission success. As missions become more complex and longer in duration, the risk of a fire becomes more probable and catastrophic. A greater understanding of the effects of a fire inside a crewed vehicle at potential exploration atmospheres is needed. These exploration atmospheres, such as those being proposed for upcoming Lunar missions, include higher oxygen concentrations and lower pressures, also known as Normoxic conditions. Full scale fire testing, such as those performed during previous space programs, is the most straightforward way to obtain this understanding. These tests are difficult to implement in 1-g and even more challenging to attempt in Lunar-g. Modeling can help inform experiments aimed at determining flammability properties of common materials at exploration atmospheres, as well as determine the effect a fire has inside a spacecraft. A model can also be easily simulated in Lunar-g to predict the effect of gravity on fire propagation. This work focuses on a model of a theoretical partial crew cabin, with potential fire sources being a laptop and a Nomex sleeping bag. A simulation of the crew cabin during a high Heat Release Rate (HRR) fire and low HRR fire at 1-g was compared to simulations at Lunar-g. It was found that in both the low and high HRR cases, the temperature in the cabin was higher in the Lunar-g case than in the 1-g case. This is likely due to the hot products moving out the door of the crew cabin faster in the 1-g case. Modeling case studies like these will help guide future full-scale flammability experiments on Earth and allow for the prediction of fire spread in a Lunar gravity environment in order to design a safer crew cabin.

Fire Safety↗

Microgravity combustion discipline working group summary of requirements for noncontact temperature measurements

Current efforts of the Microgravity Combustion Working Group are summarized and the temperature measurement requirements for the combustion studies are defined. Many of the combustion systems that are studied in the low gravity environment are near-limit systems, that is, systems that are acting near the limit of flammability in terms of oxygen concentration or fuel concentration. Systems of this type are normally weak in the sense that there is a delicate balance between the heat released in the flame and the heat required to sustain the flame. Intrusive or perturbative temperature measurement probes can be inaccurate in these situations and in the limiting case extinguish the flame. Noncontact techniques then become the only way to obtain the required measurements. Noncontact measurement requirements for each of the three thermodynamic phases are described in terms of spatial and temporal resolution and temperature range.

Sacksteder, Kurt↗

Improved Polypropylene Thermoformability through Polyethylene Layering

Due to its low cost, stiffness, and recyclability, isotactic polypropylene (iPP) is an excellent candidate for packaging applications. However, iPP is notoriously difficult to thermoform due to its low melt strength. The addition of just 10 thin layers of high-molecular-weight, linear low-density polyethylene (LLDPE) into iPP sheets by coextrusion significantly increased extensional viscosity and reduced sag. Both LLDPE and iPP were metallocene-catalyzed with excellent adhesion as measured in our previous work. Here, we performed a series of hot tensile tests and sheet sag measurements to determine the properties of the iPP sheet and the multilayer sheet between 130 and 180 °C. To evaluate the thermoformability of these multilayer sheets, truncated conical cups were positive vacuum formed at different temperatures and heating times, and the crush strength was measured. Cups that released easily from the mold with good shape retention and a crush strength within 80% of the maximum value were used to define a temperature–time thermoformability window. We estimated the maximum stress that occurred during the thermoforming process to be 5 MPa. Layer thicknesses before and after thermoforming were used to estimate an average strain of 0.78. The thin LLDPE layers decreased the yield stress below 5 MPa. This enabled thermoforming at sheet temperatures as low as 150 °C. The immiscible LLDPE interfaces increased extensional viscosity, which decreased sag in the multilayer sheets compared to iPP. This broadened the thermoforming range to temperatures as high as 180 °C and allowed longer heating times. These highly thermoformable, layered sheets may be recycled as iPP since they contain only 8% of LLDPE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the impact of peat soils and snow schemes on simulated active layer thickness at pan-Arctic permafrost sites

Abstract Permafrost stability is significantly influenced by the thermal buffering effects of snow and active-layer peat soils. In the warm season, peat soils act as a barrier to downward heat transfer mainly due to their low thermal conductivity. In the cold season, the snowpack serves as a thermal insulator, retarding the release of heat from the soil to the atmosphere. Currently, many global land models overestimate permafrost soil temperature and active layer thickness (ALT), partially due to inaccurate representations of soil organic matter (SOM) density profiles and snow thermal insulation. In this study, we evaluated the impacts of SOM and snow schemes on ALT simulations at pan-Arctic permafrost sites using the Energy Exascale Earth System Model (E3SM) land model (ELM). We conducted simulations at the Circumpolar Active Layer Monitoring (CALM) sites across the pan-Arctic domain. We improved ELM-simulated site-level ALT using a knowledge-based hierarchical optimization procedure and examined the effects of precipitation-phase partitioning methods (PPMs), snow compaction schemes, and snow thermal conductivity schemes on simulated snow depth, soil temperature, ALT, and CO 2 fluxes. Results showed that the optimized ELM significantly improved agreement with observed ALT (e.g. RMSE decreased from 0.83 m to 0.15 m). Our sensitivity analysis revealed that snow-related schemes significantly impact simulated snow thermal insulation levels, soil temperature, and ALT. For example, one of the commonly used snow thermal conductivity schemes (quadratic Sturm or SturmQua) generally produced warmer soil temperatures and larger ALT compared to the other two tested schemes. The SturmQua scheme also amplified the model’s sensitivity to PPMs and predicted deeper ALTs than the other two snow schemes under both current and future climates. The study highlights the importance of accurately representing snow-related processes and peat soils in land models to enhance permafrost dynamics simulations.

54 ENVIRONMENTAL SCIENCES↗

Refined Sensitivity Estimates for Single-Molecule Magnet Dark Matter Detectors

We revisit the sensitivity of Single Molecule Magnet (SMM) crystals as detectors for low-mass dark matter. In previous work, we established the concept of the ``magnetic bubble chamber'', where energy deposited by dark matter triggers a magnetic avalanche in a metastable crystal. The original sensitivity estimates relied on a conservative criterion requiring the spin relaxation time to be strictly shorter than the thermal diffusion time. Here, we demonstrate that this criterion effectively ignores the stochastic nature of spin relaxation. We derive a refined analytic estimate which accounts for the fraction of spins that relax even when diffusion is fast. We show that the Zeeman energy released by this fraction contributes to local heating, significantly lowering the energy threshold for avalanche formation. We present simulation results confirming this effect and report on experimental verification of the assumed low-temperature thermal properties of two representative SMM crystals, Mn$_{12}$-acetate and Mn$_{32}$. Together, these efforts extend this pathfinder program toward the realization of SMM-based detectors with controlled material properties and enhanced dark matter sensitivity.

Eberhardt, Andrew [Tokyo U., IPMU]↗

Development of processes for the production of solar grade silicon from halides and alkali metals

High temperature reactions of silicon halides with alkali metals for the production of solar grade silicon in volume at low cost were studied. Experiments were performed to evaluate product separation and collection processes, measure heat release parameters for scaling purposes, determine the effects of reactants and/or products on materials of reactor construction, and make preliminary engineering and economic analyses of a scaled-up process.

Dickson, C. R.↗

Dynamics of the Impacts

The SL9 impacts are best known by their plumes, several of which were imaged towering 3000 km above Jupiter's limb. The heat released when they fen back on the atmosphere produced the famous infrared main events. The reentry shock was observed directly in CO emission and indirectly through thermally glowing dust. The relatively low color temperature of the latter implies that most of the energy released on reentry was radiated. If so, the R impact released some 3 x 10(exp 26) ergs, and the larger L, K, and G impacts as much as 3 x 10(exp 27) ergs. These estimates agree well with impact energies deduced from tidal disruption computations. The duration of the infrared events measures time aloft and hence provides a second measure of plume height. These indicate that plume height was only weakly dependent on impact energy. Evidently all the plumes were launched at roughly 10-13 km/s. Using a semi-analytic model for the deceleration, disintegration, and destruction of intruding bodies by an ever-vigilant atmosphere, we find that similar plume heights is a direct consequence of smaller impactors exploding at higher altitudes, in such a way that the different explosions were geometrically similar. We then compare the predictions of our model to the Venerian cratering record, which provides a good statistical test of impact deceleration by a thick atmosphere. Chemistry should have provided an independent measure of explosion altitude: abundant shock-generated CS, CS2 and HCN indicates a source in dry jovian air, above the putative water clouds. However, the Galileo Probe results seem to imply that we should expect no more. Observed water and S2 are consistent with a somewhat oxidized gas (presumably the comet itself), but the absence of SO2 and CO2 shows that conditions were neither too oxidizing nor the shocks too hot.

Zahnle, Kevin↗

Passive Gas-Gap Heat Switches for Use in Low-Temperature Cryogenic Systems

We present the current state of development in passive gas-gap heat switches. This type of switch does not require a separate heater to activate heat transfer but, instead, relies upon the warming of one end due to an intrinsic step in a thermodynamic cycle to raise a getter above a threshold temperature. Above this temperature sequestered gas is released to couple both sides of the switch. This enhances the thermodynamic efficiency of the system and reduces the complexity of the control system. Various gas mixtures and getter configurations will be presented.

Heat Switches↗

Thermochemical generation of hydrogen

The direct fluid contact heat exchange with H2SO4 at about 330 C prior to high temperature decomposition at about 830 C in the oxygen release step of several thermochemical cycles for splitting water into hydrogen and oxygen provides higher heat transfer rates, savings in energy and permits use of cast vessels rather than expensive forged alloy indirect heat exchangers. Among several candidate perfluorocarbon liquids tested, only perfluoropropylene oxide polymers having a degree of polymerization from about 10 to 60 were chemically stable, had low miscibility and vapor pressure when tested with sulfuric acid at temperatures from 300 C to 400 C.

Lawson, D. D.↗

Enhancing the efficiency benefit of thermal barrier coatings for homogeneous charge compression ignition engines through application of a low-k oxide

Prior experiments reported by the authors have proven the hypothesis that achieving a dynamic temperature swing on the combustion chamber surface will lead to improved thermal and combustion efficiencies of the homogeneous charge compression ignition engine. A thin layer of yttria-stabilized zirconia, roughly 150 μm, was plasma sprayed on the piston top. It led to markedly advanced ignition and heat release in the gasoline homogeneous charge compression ignition engine, accompanied with reduced unburnt hydrocarbon and carbon monoxide emissions, improved combustion efficiency, and a higher thermal efficiency. A related computational study highlighted the critical role of coating thermal conductivity in achieving a desired dynamic response; hence, the second phase of experimental investigations focused on introducing structured porosity in the yttria-stabilized zirconia coating, as a means of reducing effective conductivity. Indeed, additional incremental improvements were observed, as well as limitations related to adverse effects of the surface roughness and the fuel interactions with the surface roughness and open pores. Erosion can also be a problem in a direct injection engine. Therefore, the third round of investigations focused on a material with a natively low conductivity (low-k), sprayed on the top of an Al piston in a relatively dense form, and in a way that yields a smooth surface. The objective was to capitalize on the low conductivity, while avoiding the pitfalls accompanying high-porosity formulations. The heat-storage capacity was limited by keeping the thickness relatively low. The results verify the paramount importance of thermal conductivity in the context of high “temperature swing” behavior and indicate a potential to improve the homogeneous charge compression ignition engine’s combustion efficiency roughly 1.5%, with the overall indicated efficiency improvement on the order of 5%, on a relative basis. In addition, the low-k oxide thermal barrier applied to the piston extended significantly the low-load homogeneous charge compression ignition operability limit.

42 ENGINEERING↗

Possible quadrupole-order-driven commensurate-incommensurate phase transition in B20 CoGe

For this study, the B20-type cobalt germanide CoGe was investigated by measuring the specific heat, resistivity, and 59 Co nuclear magnetic resonance (NMR). We observed a phase transition at T Q = 13.7 K, evidenced by a very narrow peak of the specific heat and sharp changes of the nuclear spin-spin (T 2 –1 ) and spin-lattice ( T 1 – 1 ) relaxation rates. The fact that the entropy release is extremely small and the Knight shift is almost independent of temperature down to low temperatures as anticipated in a paramagnetic metal indicates that the T Q transition is of nonmagnetic origin. In addition, we detected a crossover scale T 0 ~ 30 K below which the resistivity and the NMR linewidth increase, and T 1 –1 is progressively distributed in space, that is, a static and dynamical spatial inhomogeneity develops. While the order parameter for the T Q transition remains an open question, a group-theoretical analysis suggests that the finite electric quadrupole density arising from the low local site symmetry at cobalt sites could drive the crystal symmetry lowering from the P2 1 3 symmetry that is commensurate to the R3 symmetry with an incommensurate wave vector, which fairly well accounts for the T Q transition. The quadrupole-order-driven commensurate-incommensurate phase transition may be another remarkable phenomenon arising from the structural chirality inherent in the noncentrosymmetric B20 family.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of the supercritical CO 2 recompression Brayton power cycle with a high-temperature regenerator

The supercritical carbon dioxide (sCO 2 ) recompression Brayton cycle promises higher efficiency and lower capital cost than traditional steam Rankine power cycles. However, achieving high efficiency requires large, highly effective recuperators. Regenerators may be a low-cost alternative to printed circuit and micro-tube heat exchangers for recuperation in sCO 2 power cycles. Regenerators are a periodic heat exchanger in which thermal energy is extracted from the hot stream, stored in solid media, and then released to the cold stream at a later time. Fixed bed regenerators with valves to direct fluid are the preferred method for implementing regenerators in power cycles, but the inherently transient nature of these systems has not been characterized for this application. This study presents the simulation of a high-temperature regenerator within a 10 MWe sCO 2 recompression Brayton cycle. A transient, one-dimensional regenerator model presented in a previous study is used to simulate the regenerator. Dynamic heat exchanger models are also developed for the precooler, low-temperature recuperator, and primary heat exchanger, and the compressors and the turbine are modeled with off-design performance maps. We assess two regenerator-valve design options; one for fast switching, and one for reduced flow rate fluctuations. System simulation finds that both designs see significant fluctuations in turbomachinery flow rate, turbomachinery and system power, and regenerator discharge process outlet temperature. While designing the regenerator-valve subsystem for lower fluctuations is possible, the regenerator cold discharge temperature and net power still fluctuate by ±77.6°C and 6%, respectively. Increasing buffer volume is not effective at sufficiently reducing these fluctuations, but adding a packed bed in between the regenerator and the primary heat exchanger can reduce regenerator discharge process outlet temperature fluctuations to 6.4°C. Further reductions could be possible by increasing the size of this packed bed.

42 ENGINEERING↗

Application of Ibuprofen Sodium Dihydrate for Thermochemical Energy Storage

Thermochemical energy storage (TCES) offers a transformative approach to address grid instability by harnessing reversible chemical reactions for efficient heat storage and release. Here, we introduce pharmaceutical organic salt hydrates as a class of materials with exceptional performance for low-grade waste heat recovery. We demonstrate ibuprofen sodium dihydrate (ISD) as an example organic hydrate exhibiting a dehydration temperature range of 60-110 °C and a remarkable dehydration enthalpy of up to 59.5 kJ/mol of water, ideally suited for capturing industrial and residential waste heat. Using rigorous multimodal characterization, including thermogravimetric analysis, differential scanning calorimetry, in-situ FTIR, in-situ PXRD, and NMR, we demonstrate ISD's superior thermal, chemical, and structural stability over 150 hydration-dehydration cycles, achieving an unprecedented cycling efficiency of ~99.9%. Compared to conventional inorganic salt hydrates like strontium chloride hexahydrate and calcium oxalate monohydrate, ISD showcases enhanced durability without deliquescence or pulverization, even under high-humidity conditions. In-situ analyses confirm the transition from ISD to ibuprofen sodium anhydrous (ISA) proceeds with structural reorganization, thereby combining the dehydration mechanism with phase transitions, resulting in higher energy storage capacity. Microstructural analyses reveal that repeated water intercalation and structural transitions aid in creating significant porosity that enhances water transport kinetics, further improving the hydration/dehydration performance. By combining the phase change and chemical dehydration mechanisms, ISD paves the way for designing a new class of organic salt hydrates, offering tunable properties to meet diverse thermal energy storage demands and supporting sustainable grid resilience.

Thangaraj, Kavin C.↗

Initial Results on a New Light-Duty 2.7-L Opposed-Piston Gasoline Compression Ignition Multi-Cylinder Engine

Abstract Gasoline compression ignition (GCI) is a cost-effective approach to achieving diesel-like efficiencies with low emissions. The fundamental architecture of the two-stroke Achates Power Opposed-Piston (OP) Engine enables GCI by decoupling piston motion from cylinder scavenging, allowing for flexible and independent control of cylinder residual fraction and temperature leading to improved low-load combustion. In addition, the high peak cylinder pressure and noise challenges at high-load operation are mitigated by the lower brake mean effective pressure (BMEP) operation and faster heat release for the same pressure rise rate of the OP Engine. These advantages further solidify the performance benefits of the OP Engine and demonstrate the near-term feasibility of advanced combustion technologies, enabled by the opposed-piston architecture. This paper presents initial results from steady-state testing on a brand new 2.7-L OP GCI multi-cylinder engine (MCE) designed for light-duty truck applications. Successful GCI operation calls for a high compression ratio (CR), leading to higher combustion stability at low loads, higher efficiencies, and lower cycle HC + NOX emissions. Initial results show a cycle average brake thermal efficiency (BTE) of 31.7%, which is already greater than 11% conventional engines, after only ten weeks of testing. Emissions results suggest that Tier 3 Bin 160 levels can be achieved using a traditional diesel after-treatment system. Combustion noise was well controlled at or below the United States Council for Automotive Research limits. In addition, initial results on catalyst light-off mode with GCI are also presented.

Energy & Fuels↗

Xenon Trapping in Metal-Supported Silica Nanocages

Xenon (Xe) is a valuable and scarce noble gas used in various applications, including lighting, electronics, and anesthetics, among many others. It is also a volatile byproduct of the nuclear fission of uranium. In this work, a novel material architecture consisting of silicate nanocages in contact with a metal surface and an approach for trapping single Xe atoms in these cages is presented. The trapping is done at low Xe pressures and temperatures between 400 and 600 K, and the process is monitored in situ using synchrotron-based ambient pressure X-ray photoelectron spectroscopy. Release of the Xe from the cages occurs only when heating to temperatures above 750 K. A model that explains the experimental trapping kinetics is proposed and tested using Monte Carlo methods. Density functional theory calculations show activation energies for Xe exiting the cages consistent with experiments. This work can have significant implications in various fields, including Xe production, nuclear power, nuclear waste remediation, and nonproliferation of nuclear weapons. The results are also expected to apply to argon, krypton, and radon, opening an even more comprehensive range of applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Corrosion evaluation of metal foams in eutectic molten salts for high temperature latent heat energy storage application

High-temperature Thermal Energy Storage (TES) has drawn great attention as a technology that can increase the role and profitability of micro nuclear reactors in the decentralized clean energy market. Various research needs have been proposed by Idaho National Laboratory (INL) in "the Integrated Energy Systems: 2020 Roadmap" with the goal of utilizing the high temperature of 550 degrees or more generated in the 4th generation reactor to industrial purposes from the standpoint of integrated energy systems [1]. With the recent development of the 4th generation nuclear power plant, including micro nuclear reactor, there is a great deal of interest in researching how to efficiently couple a heat source to an industrial process through thermal processing. Texas A&M University (TAMU) and INL are currently collaborating to develop a novel latent heat storage design called HITB (Heat pipe-Integrated Thermal Battery). As part of the small-scale experimental demonstration research for HITB, a study for storage medium selection was conducted at TAMU. Eutectic salts have attracted interest as high-temperature heat storage medium for HITB. Especially, chloride molten salts and fluoride molten salts are considered promising candidates due to their high melting temperature, thermal stability, and high latent heat of fusion. Since eutectic salts have poor thermal conductivity in general, it is critical to distribute materials with high thermal conductivity evenly to facilitate the charging and discharging of heat. In this study, metal foam was considered in the HITB system to overcome the poor heat transfer characteristics of eutectic salts. In order to improve heat transfer, it is necessary to study materials with high thermal conductivity, corrosion resistant to molten salts, such as fins, extended surfaces, particles, microcapsulation, or foam structure. Porous structure of copper or aluminum can increase heat transfer area, form a thermal transfer network, and increase the effective thermal conductivity of thermal storage medium [2]. Since the melting temperature is required to be at least 450? in the current HITB design, various eutectic salts are being considered. FLiNaK and FLiBe, which are famous for fluoride salts, are good candidates, but due to the sharp rise in the price of LiF recently, they are excluded for economic reasons to be applied to large-capacity thermal energy storage. On the other hand, chloride salts are very cheap and easy to obtain, have a high melting temperature, and have a high latent heat of fusion, so they are recently in the spotlight as a phase change material. However, because of the hygroscopic nature of chloride salts, HCl gas due to impurity is easy to be released and is particularly vulnerable to corrosion. Chloride eutectic salts have been tested and suggested for metal alloys that are particularly resistant to corrosion, such as SS304, SS316, Hastelloy, Inconel 625, Incoloy 800H, which has low thermal conductivity, and is very expensive [3-6]. Porous materials with high thermal conductivity such as copper and aluminum have been tested for stability in fluids such as paraffin or water as metal foam or metal fin structures, but high temperature corrosion tests were not performed on various eutectic salts yet. Therefore, this study investigated the high temperature corrosion characteristics of metal alloys, such as C10100 foam, C10100 plate, 6101 alloy foam, and SS316 plate, while immersed in the candidate eutectic salts. A total of 20 tests for SS316 coupons and 10 tests for C10100 coupons were performed to ensure the repeatability of the present measurements. Since it is difficult to completely remove the salt inside metal foam due to the complex inner structure of the metal foam, only the surface condition was observed with a microscopy and scanning electron microscopy (SEM) image, except for measuring the corrosion rate and average mass loss.

25 ENERGY STORAGE↗

Radiative Extinction of Gaseous Spherical Diffusion Flames in Microgravity

Radiative extinction of spherical diffusion flames was investigated experimentally and numerically. The experiments involved microgravity spherical diffusion flames burning ethylene and propane at 0.98 bar. Both normal (fuel flowing into oxidizer) and inverse (oxidizer flowing into fuel) flames were studied, with nitrogen supplied to either the fuel or the oxygen. Flame conditions were chosen to ensure that the flames extinguished within the 2.2 s of available test time; thus extinction occurred during unsteady flame conditions. Diagnostics included color video and thin-filament pyrometry. The computations, which simulated flow from a porous sphere into a quiescent environment, included detailed chemistry, transport and radiation, and yielded transient results. Radiative extinction was observed experimentally and simulated numerically. Extinction time, peak temperature, and radiative loss fraction were found to be independent of flow rate except at very low flow rates. Radiative heat loss was dominated by the combustion products downstream of the flame and was found to scale with flame surface area, not volume. For large transient flames the heat release rate also scaled with surface area and thus the radiative loss fraction was largely independent of flow rate. Peak temperatures at extinction onset were about 1100 K, which is significantly lower than for kinetic extinction. One observation of this work is that while radiative heat losses can drive transient extinction, this is not because radiative losses are increasing with time (flame size) but rather because the heat release rate is falling off as the temperature drops.

Santa, K. J.↗