Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Magnetic Sensitivity of AlMn TESes and Shielding Considerations for Next-Generation CMB Surveys

In the next decade, new ground-based cosmic microwave background (CMB) experiments such as Simons Observatory, CCAT-prime, and CMB-S4 will increase the number of detectors observing the CMB by an order of magnitude or more, dramatically improving our understanding of cosmology and astrophysics. These projects will deploy receivers with as many as hundreds of thousands of transition edge sensor (TES) bolometers coupled to superconducting quantum interference device (SQUID)-based readout systems. It is well known that superconducting devices such as TESes and SQUIDs are sensitive to magnetic fields. However, the effects of magnetic fields on TESes are not easily predicted due to the complex behavior of the superconducting transition, which motivates direct measurements of the magnetic sensitivity of these devices. We present comparative four-lead measurements of the critical temperature versus applied magnetic field of AlMn TESes varying in geometry, doping, and leg length, including Advanced ACT and POLARBEAR-2/Simons Array bolometers. MoCu ACTPol TESes are also tested and are found to be more sensitive to magnetic fields than the AlMn devices. We present an observation of weak-link-like behavior in AlMn TESes at low critical currents. We also compare measurements of magnetic sensitivity for time division multiplexing SQUIDs and frequency division multiplexing microwave (mMUX) rf-SQUIDs. We discuss the implications of our measurements on the magnetic shielding required for future experiments that aim to map the CMB to near-fundamental limits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact, Low-Cost, Light-Weight, Superconducting, Ironless Cyclotrons for Hadron Radiotherapy

Superconducting cyclotrons are increasingly employed for proton beam radiotherapy treatment (PBRT). The use of superconductivity in a cyclotron design can reduce its mass by an order of magnitude and size by a factor of 3-4 over conventional resistive magnet technology, yielding significant reduction in overall cost of the device, the accelerator vault, and its infrastructure, as well as reduced operating costs. At MIT, previous work was focused on developing a very high field (9 T at the pole face) superconducting synchrocyclotron that resulted in a highly compact device that is about an order of magnitude lighter, and much smaller in diameter than a conventional, resistive cyclotron. The results of the study reported here were focused on a conceptual design for a compact superconducting synchrocyclotron to demonstrate the possibility to further reduce its weight by almost another order of magnitude by eliminating all iron from the device. In the absence of magnetic iron poles, the magnetic field profile in the beam gap is achieved through a set of main superconducting split pair coils energized in series with a set of distributed field-shaping superconducting coils. External magnetic field shielding is achieved through a set of outer, superconducting ring coils, also connected in series with the other coils, to cancel the stray magnetic field. These shielding coils replace the heavy iron yoke which is the conventional method to return the magnetic flux. It is noted that the 10 Gauss surface is located at a radius of about 3.5 m comparable in both ironless and conventional devices, even in the absence of iron in the ironless device. An important result from eliminating all magnetic iron in the flux circuit is the resulting linear relationship between the operating current and the magnetic field intensity. In the case with iron, the saturation of the magnetic field forces operation at one value of magnetic field. This feature design then enables continuous beam energy variation without the use of an energy degrader, thus eliminating secondary radiation during the in-depth beam scanning, increasing the ion current delivered to the patient and improving the beam quality. The beam energy is determined by the magnetic field strength at the extraction radius, and changing the field enables selection of the final beam energy. The magnetic field can be adjusted while maintaining the needed radial field profile.

Minervini, Joseph V.↗

Neutronics analysis of spin-polarized fuel in spherical tokamaks

The effect of spin-polarized deuterium–tritium fuel on the blanket, magnets, and surrounding structures is analyzed for a spherical tokamak fusion power plant. The focus of this paper is the neutron flux distribution in the fusion device and the corresponding engineering considerations, such as tritium breeding ratio (TBR) and magnet fluence. Significant benefits were found for anti-aligned polarization: a 2.7% increase in the total TBR (which could increase significantly with further optimization) and an approximately 68% increase in the magnet lifetime. If the inboard breeding blanket can be replaced with extra shielding and magnets, then it could significantly increase fusion power with no loss of magnet lifetime. This would be accomplished by increasing the toroidal field strength.

fusion↗

Molecular NMR shieldings, J -couplings, and magnetizabilities from numeric atom-centered orbital based density-functional calculations

This paper reports and benchmarks a new implementation of nuclear magnetic resonance shieldings, magnetizabilities, and J-couplings for molecules within semilocal density functional theory, based on numeric atom-centered orbital (NAO) basis sets. NAO basis sets are attractive for the calculation of these nuclear magnetic resonance (NMR) parameters because NAOs provide accurate atomic orbital representations especially near the nucleus, enabling high-quality results at modest computational cost. Moreover, NAOs are readily adaptable for linear scaling methods, enabling efficient calculations of large systems. Here, the paper has five main parts: (1) It reviews the formalism of density functional calculations of NMR parameters in one comprehensive text to make the mathematical background available in a self-contained way. (2) The paper quantifies the attainable precision of NAO basis sets for shieldings in comparison to specialized Gaussian basis sets, showing similar performance for similar basis set size. (3) The paper quantifies the precision of calculated magnetizabilities, where the NAO basis sets appear to outperform several established Gaussian basis sets of similar size. (4) The paper quantifies the precision of computed J-couplings, for which a group of customized NAO basis sets achieves precision of ~Hz for smaller basis set sizes than some established Gaussian basis sets. (5) The paper demonstrates that the implementation is applicable to systems beyond 1000 atoms in size.

74 ATOMIC AND MOLECULAR PHYSICS↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

QSHS: an axion dark matter resonant search apparatus

We describe a resonant cavity search apparatus for axion dark matter constructed by the quantum sensors for the hidden sector collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles, dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator (DF) and threaded by a solenoidal magnetic field, nominally 8 T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range 2.0–40 μ eV c -2 . The apparatus as currently configured is intended as a test stand for electronics over the relatively wide frequency band attainable with TM 010 the cavity mode used for axion searches. We present performance data for the resonator, DF, and magnet, and plans for the first science run.

Physics - Physics of elementary particles and fiel↗

Micro-aligned 1 Tesla Solenoid for High-energy Bunched-beam Electron Cooling

Electron cooling of ion beams requires precise alignment of the electron beam with the equilibrium trajectory of the ion bunch. In magnetized cooling the cooling rate is enhanced by transverse confinement of each electron on a magnetic line of force. The magnetic lines of force must therefore be aligned with the ion bunch trajectory everywhere along the extent of the solenoid. For the parameters required for JLEIC, a solenoid with bore field ~1 T, length ~30 m, and rms alignment of ~micro-radian is required. Such alignment has never been accomplished. The design of a micro-aligned solenoid is presented. A gap-separated stack of thin steel washers is located along the bore of the solenoid. The flux plate stack shields transverse magnetic fields from the interior, so that axial alignment is enhanced by a factor of ~10.

43 PARTICLE ACCELERATORS↗

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Upgrades of edge, divertor and scrape-off layer diagnostics of W7-X for OP1.2

In this work, Wendelstein 7-X (W7-X) is the world’s largest superconducting nuclear fusion experiment of the optimized stellarator type. In the first Operation Phase (OP1.1) helium and hydrogen plasmas were studied in limiter configuration. The heating energy was limited to 4 MJ and the main purpose of that campaign was the integral commissioning of the machine and diagnostics, which was achieved very successfully. Already from the beginning a comprehensive set of diagnostics was available to study the plasma. On the path towards high-power, high-performance plasmas, W7-X will be stepwise upgraded from an inertially cooled (OP1.2, limited to 80 MJ) to an actively cooled island divertor (OP2, 10 MW steady-state plasma operation). The machine is prepared for OP1.2 with 10 inertially cooled divertor units, and the experimental campaign has started recently.The paper describes a subset of diagnostics which will be available for OP1.2 to study the plasma edge, divertor and scrape-off layer physics including those already available for OP1.1, plus modifications, upgrades and new systems. In conclusion, the focus of this summary will be on technical and engineering aspects, like feasibility and assembly but also on reliability, thermal loads and shielding against magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron irradiation & thermomechanical experiment (NITE) - design

For the reliable long-term operation of fusion power plants, it is crucial to understand and predict the lifetime of materials in use. These materials include all structural and functional materials utilized at the first wall, blanket, magnets, and shielding. The key challenge is, that the harsh environment including high heat fluxes, high thermal stress and stress cycling, neutron irradiation, and sputtering on such materials should not be viewed separately. Currently, the synergistic loads cannot be evaluated experimentally because of the lack of adequate facilities. The purpose of that work is to design a synergetic Neutron Irradiation and Thermomechanical Experiment (NITE) for fusion materials. This design will leverage the existing Advanced-Test-Reactor (ATR), a fission reactor at the Idaho National Laboratory. We also acknowledge that with existing fission reactors the exact fusion condition cannot be created, and the limitations are critically discussed. The combination of neutron irradiation with a high heat flux is the focus. This is realized with an irradiation capsule design that includes a TRISO fueled region inside the capsule to enable a steady-state heat flux on one side of the specimen. In conclusion, the experimental design modeling showed that steady-state heat fluxes of 2.4 MW/m 2 with a thermal gradient of above 250°C can be achieved in a 5 mm thick specimen.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space radiation measurements during the Artemis I lunar mission

Space radiation is a notable hazard for long-duration human spaceflight. Associated risks include cancer, cataracts, degenerative diseases and tissue reactions from large, acute exposures. Space radiation originates from diverse sources, including galactic cosmic rays, trapped-particle (Van Allen) belts5 and solar-particle events. Previous radiation data are from the International Space Station and the Space Shuttle in low-Earth orbit protected by heavy shielding and Earth’s magnetic field and lightly shielded interplanetary robotic probes such as Mars Science Laboratory and Lunar Reconnaissance Orbiter. Limited data from the Apollo missions and ground measurements with substantial caveats are also available. Here we report radiation measurements from the heavily shielded Orion spacecraft on the uncrewed Artemis I lunar mission. At differing shielding locations inside the vehicle, a fourfold difference in dose rates was observed during proton-belt passes that are similar to large, reference solar-particle events. Interplanetary cosmic-ray dose equivalent rates in Orion were as much as 60% lower than previous observations. Furthermore, a change in orientation of the spacecraft during the proton-belt transit resulted in a reduction of radiation dose rates of around 50%. These measurements validate the Orion for future crewed exploration and inform future human spaceflight mission design.

79 ASTRONOMY AND ASTROPHYSICS↗

Printed copper-nanoplate conductor for electro-magnetic interference

As one of the conductive ink materials with high electric conductivity, elemental copper (Cu) based nanocrystals promise for printable electronics. Here, single crystalline Cu nanoplates were synthesized using a facile hydrothermal method. Size engineering of Cu nanoplates can be rationalized by using the LaMer model and the versatile Cu conductive ink materials are suitable for different printing technologies. The printed Cu traces show high electric conductivity of 6 MS m -1 , exhibiting electro-magnetic interference shielding efficiency value of 75 dB at an average thicknesses of 11 μ m. Together with flexible alumina ceramic aerogel substrates, it kept 87% conductivity at the environmental temperature of 400 °C, demonstrating the potential of Cu conductive ink for high-temperature printable electronics applications.

Materials Science↗

Interactions Observed Between Torus and Solenoid Superconducting Magnets at JLab

The Jefferson Lab 12 GeV Upgrade of Experimental End Station Hall B required a new detector system that would be more sensitive to forward going particles and able to handle higher luminosity. This new detector is CLAS12 and includes two superconducting iron-free magnets – a torus and an actively-shielded solenoid. The torus magnet consists of 6-trapezoidal racetrack-type coils while the solenoid is an actively shielded 5 T magnet. The torus and the solenoid are located in close proximity to one another and are surrounded by sensitive particle detectors. In this work, the torus and solenoid, operating at 3770 A and 2416 A respectively, were commissioned successfully and are operating normally. This paper presents observed electromagnetic interactions which include induced static mechanical loads and inductive coupling as well as a summary of some of the cryogenic interactions and how they are mitigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Field Penetration Technique to Study High Field Shielding of Multilayered Superconductors

The SIS structure which consists of alternative thin layers of superconductors and insulators on a bulk niobium has been proposed to shield niobium cavity surface from high magnetic field and hence increase the accelerating gradient. The study of the behavior of multilayer super-conductors in an external magnetic field is essential to optimize their SRF performance. In this work we report the development of a simple and efficient technique to measure penetration of magnetic field into bulk, thin film and multilayer superconductors. Experimental setup contains a small superconducting solenoid which can produce a parallel surface magnetic field up to 0.5 T and Hall probes to detect penetrated magnetic field across the superconducting sample. This system was calibrated and used to study the effect of niobium sample thickness on the field of full magnetic flux penetration. We determined the optimum thickness of the niobium substrate to fabricate the multilayer structure for the measurements in our setup. This technique was used to measure penetration fields of Nb₃Sn thin films and Nb₃Sn/Al₂O₃ multi-layers deposited on Al₂O₃ wafers.

Senevirathne, I. H.↗

Effective Local Geometry Descriptor for 29Si NMR Q4 Anisotropy

The nuclear shielding anisotropy, ζ, is a useful nuclear magnetic resonance (NMR) shielding tensor parameter in describing the extent of electron cloud distortion about an atom. Despite the advantages afforded by NMR in structural characterization, the relationship between ζ and local structure of an atom in high-symmetry environments, such as Si-Q 4 sites, is poorly understood. Here, we use a data-driven approach combining random forest feature ranking and the Sure Independence Screening and Sparsifying Operator (SISSO) approach to derive a simple and accurate geometric descriptor for ζ with a root-mean-squared prediction error of 6.77 ppm and an R 2 of 0.761. We then apply this descriptor to describe the local geometric distortion of zeolites Sigma-2 and silica-ZSM-5 whose chemical shift anisotropy tensor has been reported. We envision that this geometric descriptor will allow for structural description and refinement in previously difficult-to-describe materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instrumentation and Control Selection for the 12 GeV Hall-B Magnets at Jefferson Lab

Here, as part of the Jefferson Lab 12 GeV accelerator upgrade, the Experimental Physics Hall B detector system requires two superconducting magnets – a Torus and a Solenoid. The specifications required maximum space for the detectors which led to the choice of conduction cooling for each magnet. The Torus consists of 6 trapezoidal 'race-track'-type coils connected in series with an operating current of 3770 A. The Solenoid is an actively shielded 5 Tesla magnet consisting of 5 coils connected in series operating at 2416 A. Within the hall the two magnets are located in close proximity to each other and are surrounded by particle detectors. We describe the philosophy behind the instrumentation selection and control design that accounts for this proximity and other challenging working conditions. We describe the choice of sensor technologies, as well as the control and data acquisition methods. The magnet power and cryogenic control sub-systems are implemented using Allen Bradley Control Logix 1756-L72 Programmable Logic Controllers. Sensor instrumentation read-backs are routed into the PLC via National Instruments cRIO hardware (Field Programmable Gate Arrays or FPGA/RT application) using Jefferson Lab designed FPGA-based multi-sensor-excitation-chassis. Configuration, monitoring, and alarm handlers for the magnet systems are provided via an Experimental Physics Instrumentation & Control System interface (EPICS). Failure Modes and Effects Analysis (FMEA) and the requirement to monitor critical parameters during operation guided the selection of instrumentation and associated hardware. The design of the quench protection and voltage tap sub-systems was driven by the anticipated level of voltages developed during a magnet quench. The primary hard-wired quench detection and protection sub-system together with the secondary PLC-based protection sub-system is also discussed. The successful commissioning and subsequent performance of these magnets demonstrates the robustness of the design and implementation approach that was adopted by the Jefferson Lab team and serves as an excellent 'How To' guide for future projects of this size and complexity.

12 GeV↗