Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Light masking of circadian rhythms of heat production, heat loss, and body temperature in squirrel monkeys

Whole body heat production (HP) and heat loss (HL) were examined to determine their relative contributions to light masking of the circadian rhythm in body temperature (Tb). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of body temperature and activity. Feeding was also measured. Responses to an entraining light-dark (LD) cycle (LD 12:12) and a masking LD cycle (LD 2:2) were compared. HP and HL contributed to both the daily rhythm and the masking changes in Tb. All variables showed phase-dependent masking responses. Masking transients at L or D transitions were generally greater during subjective day; however, L masking resulted in sustained elevation of Tb, HP, and HL during subjective night. Parallel, apparently compensatory, changes of HL and HP suggest action by both the circadian timing system and light masking on Tb set point. Furthermore, transient HL increases during subjective night suggest that gain change may supplement set point regulation of Tb.

Non-NASA Center↗

The Sensitivity of Coded Mask Telescopes

Simple formulae are often used to estimate the sensitivity of coded mask X-ray or gamma-ray telescopes, but t,hese are strictly only applicable if a number of basic assumptions are met. Complications arise, for example, if a grid structure is used to support the mask elements, if the detector spatial resolution is not good enough to completely resolve all the detail in the shadow of the mask or if any of a number of other simplifying conditions are not fulfilled. We derive more general expressions for the Poisson-noise-limited sensitivity of astronomical telescopes using the coded mask technique, noting explicitly in what circumstances they are applicable. The emphasis is on using nomenclature and techniques that result in simple and revealing results. Where no convenient expression is available a procedure is given which allows the calculation of the sensitivity. We consider certain aspects of the optimisation of the design of a coded mask telescope and show that when the detector spatial resolution and the mask to detector separation are fixed, the best source location accuracy is obtained when the mask elements are equal in size to the detector pixels.

Skinner, Gerald K.↗

Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

Achromatic↗

22X mask cleaning effects on EUV lithography process and lifetime

For this paper, we evaluated the impact of repetitive cleans on a photomask that was fabricated and patterned for extreme ultraviolet lithography exposure. The lithographic performance of the cleaned mask, in terms of process window and line edge roughness, was monitored with the SEMATECH Berkeley micro-exposure tool (MET). Each process measurement of the cleaned mask was compared to a reference mask with the same mask architecture. Both masks were imaged on the same day in order to eliminate any process-related measurement uncertainties. The cleaned mask was periodically monitored with atomic force microscopy (AFM) measurements and pattern widths were monitored using scanning electron microscopy (SEM). In addition, reflectivity changes were also tracked with the aid of witness plate measurements. At the conclusion of this study, the mask under evaluation was cleaned 22 times; with none of the evaluation techniques showing any significant degradation in performance.

36 MATERIALS SCIENCE↗

Universal parameters of bulk-solvent masks

The bulk solvent is a major component of biomacromolecular crystals that contributes significantly to the observed diffraction intensities. Accurate modelling of the bulk solvent has been recognized as important for many crystallographic calculations. Owing to its simplicity and modelling power, the flat (mask-based) bulk-solvent model is used by most modern crystallographic software packages to account for disordered solvent. In this model, the bulk-solvent contribution is defined by a binary mask and a scale (scattering) function. The mask is calculated on a regular grid using the atomic model coordinates and their chemical types. The grid step and two radii, solvent and shrinkage, are the three parameters that govern the mask calculation. They are highly correlated and their choice is a compromise between the computer time needed to calculate the mask and the accuracy of the mask. It is demonstrated here that this choice can be optimized using a unique value of 0.6 Å for the grid step irrespective of the data resolution, and the radii values adjusted correspondingly. The improved values were tested on a large sample of Protein Data Bank entries derived from X-ray diffraction data and are now used in the computational crystallography toolbox ( CCTBX ) and in Phenix as the default choice.

36 MATERIALS SCIENCE↗

Benchtop assessment of sealing efficacy and breathability of additively manufactured (AM) face masks

The onset of the 2019 novel coronavirus disease (COVID-19) led to a shortage of personal protective equipment (PPE), medical devices, and other medical supplies causing many stakeholders and the general public alike to turn to additive manufacturing (AM) as a stopgap when normally accessible devices were not available. However, without a method to test these AM constructs, there continued to be a disconnect between AM suppliers and the community’s needs. The objective of this study was to characterize the pressure drop and leakage of four different publicly available AM face mask models with two filter material combinations, as well as to investigate the impact of frame modification techniques including the use of foam strips and hot-water face forming to improve fit when the masks are donned on manikin head forms. AM face mask frame designs were downloaded from public repositories during the early stages of the COVID-19 pandemic. AM face masks were fabricated and tested on manikin head forms within a custom chamber containing dry aerosolized NaCl. Pressure drops, particle penetration, and leakage were evaluated for various flow rates and NaCl concentrations. Results indicated that filter material combination and frame modification played a major role in the overall performance of the AM face masks studied. Filter material combinations showed improved performance when high filtration fabric was used, and the cross-sectional area of the fabric was increased. AM frame modifications appeared to improve AM face mask leakage performance by as much as 69.6%.

36 MATERIALS SCIENCE↗

Original images, ground truth annotations, and precited masks from U-NET for a fungal species x nitrogen experiment

This document describes the “MicroVision-MV003” dataset. This folder contains three subfolders: “originals”, “predicted_masks”, and “gt_masks”. The “originals” folder contains 720 original images acquired using two imaging modalities: 360 images from overhead imaging and 360 images from transmission (raw) imaging. Naming scheme:YYYY-MM-dd__plate_strain_nitrogen-level_replication_experiment_imaging-modalityYYYY-MM-dd: 2024-12-20, 2024-12-21, 2024-12-22,2024-12-23,2024-12-24,2024-12-25,2024-12-26,2024-12-27,2024-12-28,2024-12-29,2024-12-30,2024-12-31.plate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30.strain: FG, LE.nitrogen-level: N-1, N-10, N-100.replication: 1, 2, 3, 4, 5.experiment: MV.003.imaging-modality: overhead, transmission (raw). For example, the image2024-12-20__1_FG_N-10_3_MV.003_overheadwas taken on 2024-12-20. The plate number is 1, the fungal strain is FG, the nitrogen treatment is N-10, and the replication number is 3 for experiment MV.003, acquired using the overhead imaging modality. The “predicted_masks” folder contains masks generated by a trained U-Net model for the transmission imaging modality.The “gt_masks” folder contains 326 human hand-traced masks that serve as ground truth.

09 BIOMASS FUELS↗

Cone-Beam CT Assessment of Interfraction and Intrafraction Setup Error of Two Head-and-Neck Cancer Thermoplastic Masks

Purpose: To prospectively compare setup error in standard thermoplastic masks and skin-sparing masks (SSMs) modified with low neck cutouts for head-and-neck intensity-modulated radiation therapy (IMRT) patients. Methods and Materials: Twenty head-and-neck IMRT patients were randomized to be treated in a standard mask (SM) or SSM. Cone-beam computed tomography (CBCT) scans, acquired daily after both initial setup and any repositioning, were used for initial and residual interfraction evaluation, respectively. Weekly, post-IMRT CBCT scans were acquired for intrafraction setup evaluation. The population random (sigma) and systematic (SIGMA) errors were compared for SMs and SSMs. Skin toxicity was recorded weekly by use of Radiation Therapy Oncology Group criteria. Results: We evaluated 762 CBCT scans in 11 patients randomized to the SM and 9 to the SSM. Initial interfraction sigma was 1.6 mm or less or 1.1 deg. or less for SM and 2.0 mm or less and 0.8 deg. for SSM. Initial interfraction SIGMA was 1.0 mm or less or 1.4 deg. or less for SM and 1.1 mm or less or 0.9 deg. or less for SSM. These errors were reduced before IMRT with CBCT image guidance with no significant differences in residual interfraction or intrafraction uncertainties between SMs and SSMs. Intrafraction sigma and SIGMA were less than 1 mm and less than 1 deg. for both masks. Less severe skin reactions were observed in the cutout regions of the SSM compared with non-cutout regions. Conclusions: Interfraction and intrafraction setup error is not significantly different for SSMs and conventional masks in head-and-neck radiation therapy. Mask cutouts should be considered for these patients in an effort to reduce skin toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ScAlN etch mask for highly selective silicon etching

Here, this work reports the utilization of a recently developed film, ScAlN, as a silicon etch mask offering significant improvements in high etch selectivity to silicon. Utilization of ScAlN as a fluorine chemistry based deep reactive ion etch mask demonstrated etch selectivity at 23 550:1, four times better than AlN, 11 times better than Al 2 O 3 , and 148 times better than silicon dioxide with significantly less resputtering at high bias voltage than either Al 2 O 3 or AlN. Ellipsometry film thickness measurements show less than 0.3 nm/min mask erosion rates for ScAlN. Micromasking of resputtered Al for Al 2 O 3 , AlN, and ScAlN etch masks is also reported here, utilizing cross-sectional scanning electron microscope and confocal microscope roughness measurements. With lower etch bias, the reduced etch rate can be optimized to achieve a trench bottom surface roughness that is comparable to SiO 2 etch masks. Etch mask selectivity enabled by ScAlN is likely to make significant improvements in microelectromechanical systems, wafer level packaging, and plasma dicing of silicon.

36 MATERIALS SCIENCE↗

SU-E-T-603: Analysis of Optical Tracked Head Inter-Fraction Movements Within Masks to Access Intracranial Immobilization Techniques in Proton Therapy

Purpose: We present a quantitative methodology utilizing an optical tracking system for monitoring head inter-fraction movements within brain masks to assess the effectiveness of two intracranial immobilization techniques. Methods and Materials: A 3-point-tracking method was developed to measure the mask location for a treatment field at each fraction. Measured displacement of mask location to its location at first fraction is equivalent to the head movement within the mask. Head movements for each of treatment fields were measured over about 10 fractions at each patient for seven patients; five treated in supine and two treated in prone. The Q-fix Base-of-Skull head frame was used in supine while the CIVCO uni-frame baseplate was used in prone. Displacements of recoded couch position of each field post imaging at each fraction were extracted for those seven patients. Standard deviation (S.D.) of head movements and couch displacements was scored for statistical analysis. Results: The accuracy of 3PtTrack method was within 1.0 mm by phantom measurements. Patterns of head movement and couch displacement were similar for patients treated in either supine or prone. In superior-inferior direction, mean value of scored standard deviations over seven patients were 1.6 mm and 3.4 mm for the head movement and the couch displacement, respectively. The result indicated that the head movement combined with a loose fixation between the mask-to-head frame results large couch displacements for each patient, and also large variation between patients. However, the head movement is the main cause for the couch displacement with similar magnitude of around 1.0 mm in anterior-posterior and lateral directions. Conclusions: Optical-tracking methodology independently quantifying head movements could improve immobilization devices by correctly acting on causes for head motions within mask. A confidence in the quality of intracranial immobilization techniques could be more efficient by eliminating the need for frequent imaging.

60 APPLIED LIFE SCIENCES↗

Influence of auditory fatigue on masked pure-tone thresholds

A description is presented of four related experiments involving conditions of 3-kHz low-intensity masking, a replication of experiment I with slight variations, 3-kHz high-intensity masking, and 6-kHz low-intensity masking. The frequencies of the tones which the observers detected were 3 and 6 kHz. The observed change in masked-tone threshold as a function of fatigue is discussed. It is found that masked-tone-detection thresholds remain essentially unchanged following fatigue if the masking-noise intensity is sufficiently great.

Parker, D. E.↗

Secondary gamma-ray production in a coded aperture mask

The application of the coded aperture mask to high energy gamma-ray astronomy will provide the capability of locating a cosmic gamma-ray point source with a precision of a few arc-minutes above 20 MeV. Recent tests using a mask in conjunction with drift chamber detectors have shown that the expected point spread function is achieved over an acceptance cone of 25 deg. A telescope employing this technique differs from a conventional telescope only in that the presence of the mask modifies the radiation field in the vicinity of the detection plane. In addition to reducing the primary photon flux incident on the detector by absorption in the mask elements, the mask will also be a secondary radiator of gamma-rays. The various background components in a CAMTRAC (Coded Aperture Mask Track Chamber) telescope are considered. Monte-Carlo calculations are compared with recent measurements obtained using a prototype instrument in a tagged photon beam line.

Owens, A.↗

Techniques for Producing Coastal Land Water Masks from Landsat and Other Multispectral Satellite Data

Coastal erosion and land loss continue to threaten many areas in the United States. Landsat data has been used to monitor regional coastal change since the 1970s. Many techniques can be used to produce coastal land water masks, including image classification and density slicing of individual bands or of band ratios. Band ratios used in land water detection include several variations of the Normalized Difference Water Index (NDWI). This poster discusses a study that compares land water masks computed from unsupervised Landsat image classification with masks from density-sliced band ratios and from the Landsat TM band 5. The greater New Orleans area is employed in this study, due to its abundance of coastal habitats and its vulnerability to coastal land loss. Image classification produced the best results based on visual comparison to higher resolution satellite and aerial image displays. However, density sliced NDWI imagery from either near infrared (NIR) and blue bands or from NIR and green bands also produced more effective land water masks than imagery from the density-sliced Landsat TM band 5. NDWI based on NIR and green bands is noteworthy because it allows land water masks to be generated from multispectral satellite sensors without a blue band (e.g., ASTER and Landsat MSS). NDWI techniques also have potential for producing land water masks from coarser scaled satellite data, such as MODIS.

Spruce, Joseph P.↗

Low-order aberration sensitivity of eighth-order coronagraph masks

In a recent paper, Kuchner, Crepp, and Ge describe new image-plane coronagraph mask designs that reject to eighth order the leakage of starlight caused by image motion at the mask, resulting in a substantial relaxation of image centroiding requirements compared to previous fourth-order and second-order masks. They also suggest that the new masks are effective at rejecting leakage caused by low-order aberrations (e.g., focus, coma, and astigmatism). In this paper, we derive the sensitivity of eighth-order masks to aberrations of any order and provide simulations of coronagraph behavior in the presence of optical aberrations.We find that the masks leak light as the fourth power of focus, astigmatism, coma, and trefoil. This has tremendous performance advantages for the Terrestrial Planet Finder Coronagraph.

planetary systems↗

Techniques for Producing Coastal Land Water Masks from Landsat and Other Multispectral Satellite Data

Coastal erosion and land loss continue to threaten many areas in the United States. Landsat data has been used to monitor regional coastal change since the 1970's. Many techniques can be used to produce coastal land water masks, including image classification and density slicing of individual bands or of band ratios. Band ratios used in land water detection include several variations of the Normalized Difference Water Index (NDWI). This poster discusses a study that compares land water masks computed from unsupervised Landsat image classification with masks from density-sliced band ratios and from the Landsat TM band 5. The greater New Orleans area is imployed in this study, due to its abundance of coastal habitats and ist vulnerability to coastal land loss. Image classification produced the best results based on visual comparison to higher resolution satellite and aerial image displays. However, density-sliced NDWI imagery from either near infrared (NIR) and blue bands or from NIR and green bands also produced more effective land water masks than imagery from the density-sliced Landsat TM band 5. NDWI based on NIR and green bands is noteworthy because it allows land water masks to be generated form multispectral satellite sensors without a blue band (e.g., ASTER and Landsat MSS). NDWI techniques also have potential for producing land water masks from coarser scaled satellite data, such as MODIS.

Spruce, Joe↗

Prediction and Evaluation of the Image of the WFIRST Coronagraph Pupil at the Shaped-Pupil Mask

To create a high contrast field of view with a shaped pupil coronagraph (SPC), the telescope pupil is imaged onto the shaped pupil mask, the shaped pupil mask is designed and fabricated through a design optimization based on a given pupil wavefront, and deformable mirrors (DM) in the coronagraph are modulated according to a nonlinear optimization procedure. Both the mask design optimization and the DM optimization require accurate knowledge of the image of the pupil at the shaped pupil plane for the calculation of Jacobians, and the evaluation of alignment tolerances. The shaped pupil coronagraphs demonstrated in the high contrast imaging testbed (HCIT) at JPL has heretofore assumed perfect imaging of the pupil onto the shaped pupil mask. Similarly, the design and performance modeling of the WFIRST CGI instrument makes the same assumption. In this paper we estimate and compare the image of the pupil mask at the shaped pupil plane in the case of the coronagraph testbed, and the image of the telescope pupil at the shaped pupil plane for the WFIRST CGI instrument. The estimated pupil images include field curvature and aberrations resulting from the layout of the parabolic mirror imaging system, which is optimized for the source image, not the image of the pupil. We also show the results of direct measurement of the image of the pupil mask at the shaped pupil plane in the coronagraph testbed.

Crowther, Blake↗

Initial Laboratory Demonstration of Multi-Star Wavefront Control at the Occulting Mask Coronagraph Testbed

Online Abstract: A majority of Sun-like stars, such as the A and B components of Alpha Centauri, have at least one stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that removes stellar leakage from both stellar components, enabling direct imaging of planets in many binary star systems. We present the latest experimental and modeling results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL. OMC has a layout similar to the Roman Space Telescope coronagraph instrument (CGI), and we used a MSWC mask similar to the one that was contributed to the Roman CGI. Our results represent the first demonstrations of this technique on the OMC testbed, with the ultimate goal of demonstrating full MSWC with validated models at contrast levels relevant to Roman CGI. Technical Review Abstract: A majority of Sun-like stars have at least one stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument, limiting the achievable contrast. These include high-quality target stars such as the A and B components of Alpha Centauri, our nearest stellar neighbor. Enabling direct imaging of binary stars has the potential to increase the scientific yield for coronagraphic instruments planned on NASA's future space missions including the Roman Space Telescope and the next IR/O/UV Flagship recommended by Astro2020. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that simultaneously removes the (mutually incoherent) stellar leakage from both stellar components, enabling direct imaging of planets in many binary star systems. MSWC is an algorithmic technique and can be used with existing wavefront control systems on coronagraphic instruments (as well as starshades if a deformable mirror is available in the optical path). We summarize the latest experimental and numerical results obtained with MSWC as part of the technology development effort to demonstrate compatibility with existing high-contrast imaging platforms for this technique. The Super-Nyquist regime of MSWC was tested in vacuum at JPL's High Contrast Imaging Testbed (HCIT) on the Decadal Survey Testbed (DST) reaching 8.6e-9 contrast in a 10% band. Recently, the Occulting Mask Coronagraph (OMC) testbed at JPL is being prepared for demonstrations of Multi-Star Wavefront Control. A shaped pupil mask similar to the contributed MSWC mask on the Roman Space Telescope's coronagraph instrument has been recently manufactured including matching Lyot and focal plane masks and being installed on the OMC testbed. The goal of this experiment is a demonstration of MSWC using validated models on a testbed configuration and at contrast levels relevant to the Roman coronagraphic instrument.

High-contrast imaging↗

Mask roughness induced LER control and mitigation: aberrations sensitivity study and alternate illumination scheme

Here we conduct a mask-roughness-induced line-edge-roughness (LER) aberrations sensitivity study both as a random distribution amongst the first 16 Fringe Zernikes (for overall aberration levels of 0.25, 0.50, and 0.75nm rms) as well as an individual aberrations sensitivity matrix over the first 37 Fringe Zernikes. Full 2D aerial image modeling for an imaging system with NA = 0.32 was done for both the 22-nm and 16-nm half-pitch nodes on a rough mask with a replicated surface roughness (RSR) of 100 pm and a correlation length of 32 nm at the nominal extreme-ultraviolet lithography (EUVL) wavelength of 13.5nm. As the ideal RSR value for commercialization of EUVL is 50 pm and under, and furthermore as has been shown elsewhere, a correlation length of 32 nm of roughness on the mask sits on the peak LER value for an NA = 0.32 imaging optic, these mask roughness values and consequently the aberration sensitivity study presented here, represent a worst-case scenario. The illumination conditions were chosen based on the possible candidates for the 22-nm and 16-nm half-pitch nodes, respectively. In the 22-nm case, a disk illumination setting of {sigma} = 0.50 was used, and for the 16-nm case, crosspole illumination with {sigma} = 0.10 at an optimum offset of dx = 0 and dy = .67 in sigma space. In examining how to mitigate mask roughness induced LER, we considered an alternate illumination scheme whereby a traditional dipole's angular spectrum is extended in the direction parallel to the line-and-space mask absorber pattern to represent a 'strip'. While this illumination surprisingly provides minimal improvement to the LER as compared to several alternate illumination schemes, the overall imaging quality in terms of image-log-slope (ILS) and contrast is improved.

36 MATERIALS SCIENCE↗