Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

First results of the CAST-RADES haloscope search for axions at 34.67 μ eV

We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67 μeV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of g aγ ≳ 4 × 10 -13 GeV -1 over a mass range of 34.6738 μeV < m a < 34.6771 μeV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 μeV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational wave signals of dark matter freeze-out

We study the stochastic background of gravitational waves which accompany the sudden freeze-out of dark matter triggered by a cosmological first order phase transition that endows dark matter with mass. We consider models that produce the measured dark matter relic abundance via (1) bubble filtering, and (2) inflation and reheating, and show that gravitational waves from these mechanisms are detectable at future interferometers.

79 ASTRONOMY AND ASTROPHYSICS↗

Multichannel deconvolution of vibrational signals: A state-space inverse filtering approach

Deconvolution of noisy measurements, especially when they are multichannel, has always been a challenging problem. The processing techniques developed range from simple Fourier methods to more sophisticated model-based parametric methodologies based on the underlying acoustics of the problem at hand. Methods relying on multichannel mean-squared error processors (Wiener filters) have evolved over long periods from the seminal efforts in seismic processing. However, when more is known about the acoustics, then model-based state-space techniques incorporating the underlying process physics can improve the processing significantly. The problems of interest are the vibrational response of tightly coupled acoustic test objects excited by an out-of-the-ordinary transient, potentially impairing their operational performance. Further, employing a multiple input/multiple output structural model of the test objects under investigation enables the development of an inverse filter by applying subspace identification techniques during initial calibration measurements. Feasibility applications based on a mass transport experiment and test object calibration test demonstrate the ability of the processor to extract the excitations successfully.

42 ENGINEERING↗

Cloud response to co-condensation of water and organic vapors over the boreal forest

Abstract. Accounting for the condensation of organic vapors along with water vapor (co-condensation) has been shown in adiabatic cloud parcel model (CPM) simulations to enhance the number of aerosol particles that activate to form cloud droplets. The boreal forest is an important source of biogenic organic vapors, but the role of these vapors in co-condensation has not been systematically investigated. In this work, the environmental conditions under which strong co-condensation-driven cloud droplet number enhancements would be expected over the boreal biome are identified. Recent measurement technology, specifically the Filter Inlet for Gases and AEROsols (FIGAERO) coupled to an iodide-adduct chemical ionization mass spectrometer (I-CIMS), is utilized to construct volatility distributions of the boreal atmospheric organics. Then, a suite of CPM simulations initialized with a comprehensive set of concurrent aerosol observations collected in the boreal forest of Finland during spring 2014 is performed. The degree to which co-condensation impacts droplet formation in the model is shown to be dependent on the initialization of temperature, relative humidity, updraft velocity, aerosol size distribution, organic vapor concentration, and the volatility distribution. The predicted median enhancements in cloud droplet number concentration (CDNC) due to accounting for the co-condensation of water and organics fall on average between 16 % and 22 %. This corresponds to activating particles 10–16 nm smaller in dry diameter that would otherwise remain as interstitial aerosol. The highest CDNC enhancements (ΔCDNC) are predicted in the presence of a nascent ultrafine aerosol mode with a geometric mean diameter of ∼ 40 nm and no clear Hoppel minimum, indicative of pristine environments with a source of ultrafine particles (e.g., via new particle formation processes). Such aerosol size distributions are observed 30 %–40 % of the time in the studied boreal forest environment in spring and fall when new particle formation frequency is the highest. To evaluate the frequencies with which such distributions are experienced by an Earth system model over the whole boreal biome, 5 years of UK Earth System Model (UKESM1) simulations are further used. The frequencies are substantially lower than those observed at the boreal forest measurement site (< 6 % of the time), and the positive values, peaking in spring, are modeled only over Fennoscandia and the western parts of Siberia. Overall, the similarities in the size distributions between observed and modeled (UKESM1) are limited, which would limit the ability of this model, or any model with a similar aerosol representation, to project the climate relevance of co-condensation over the boreal forest. For the critical aerosol size distribution regime, ΔCDNC is shown to be sensitive to the concentrations of semi-volatile and some intermediate-volatility organic compounds (SVOCs and IVOCs), especially when the overall particle surface area is low. The magnitudes of ΔCDNC remain less affected by the more volatile vapors such as formic acid and extremely low- and low-volatility organic compounds (ELVOCs and LVOCs). The reasons for this are that most volatile organic vapors condense inefficiently due to their high volatility below the cloud base, and the concentrations of LVOCs and ELVOCs are too low to gain significant concentrations of soluble mass to reduce the critical supersaturations enough for droplet activation to occur. A reduction in the critical supersaturation caused by organic condensation emerges as the main driver of the modeled ΔCDNC. The results highlight the potential significance of co-condensation in pristine boreal environments close to sources of fresh ultrafine particles. For accurate predictions of co-condensation effects on CDNC, also in larger-scale models, an accurate representation of the aerosol size distribution is critical. Further studies targeted at finding observational evidence and constraints for co-condensation in the field are encouraged.

54 ENVIRONMENTAL SCIENCES↗

Production and installation of wavelength-shifting reflective light enhancers for the Short-Baseline Near Detector

We report on the design, production, and installation of a wavelength-shifting reflective system on the cathode of the Short-Baseline Near Detector (SBND), a liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam. To increase and homogenize scintillation-light collection, 64 double-sided plates were fabricated from FR4, laminated with specular reflector film and coated with 300 $μ$g/cm$^2$ of tetraphenyl butadiene (TPB) wavelength shifter using controlled physical vapor deposition. The coating uniformity was validated through dedicated measurements of deposited mass and profilometry studies. Because exposure to ambient blue/UV light could degrade the TPB, protective filtering and controlled storage conditions were implemented during handling and installation. The coated plates were assembled between conductive meshes for high-voltage compatibility and installed in situ during detector integration. This system constitutes the largest TPB-coated area deployed in a neutrino detector. It operates in conjunction with SBND's photon detection system, which consists of photomultiplier tubes and X-ARAPUCAs. Early light-collection measurements show high uniformity and light response across the detector, supporting improved triggering, calorimetry, and position reconstruction in SBND.

Acciarri, R. [Fermilab]↗

Multiplexed Inertial Coalescence Filters for High-Rate Liquid-Gas Chemistry

The aim of this project is to support the development of a disruptive method for deploying liquids in liquid-gas chemical processes to transform carbon dioxide capture from flue gas and ambient air streams. The proposed project is based on the development of a novel filtration method called the Helix MICRA™ (Multiplexed Inertial Coalescence Refining Apparatus) filters. Helix MICRA™ filters are a novel, patented filter that enable high efficiency, low-pressure drop capture of droplet streams. Liquid droplets have a large net-surface area per unit volume and have correspondingly rapid mass transfer rates. By effectively capturing these droplets after deployment, we enable high-rate carbon dioxide capture from air streams unlike any other technology. This project aims at using Helix MICRA™ filters to create efficient and compact carbon dioxide capture systems that would dramatically reduce system size and capital costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Atacama Cosmology Telescope: A Catalog of >4000 Sunyaev–Zel’dovich Galaxy Clusters

Here, we present a catalog of 4195 optically confirmed Sunyaev–Zel’dovich (SZ) selected galaxy clusters detected with signal-to-noise ratio >4 in 13,211 deg 2 of sky surveyed by the Atacama Cosmology Telescope (ACT). Cluster candidates were selected by applying a multifrequency matched filter to 98 and 150 GHz maps constructed from ACT observations obtained from 2008 to 2018 and confirmed using deep, wide-area optical surveys. The clusters span the redshift range 0.04 < z < 1.91 (median z = 0.52). The catalog contains 222 z > 1 clusters, and a total of 868 systems are new discoveries. Assuming an SZ signal versus mass-scaling relation calibrated from X-ray observations, the sample has a 90% completeness mass limit of M 500 c > 3.8 × 10 14 M ⊙ , evaluated at z = 0.5, for clusters detected at signal-to-noise ratio >5 in maps filtered at an angular scale of 2.'4. The survey has a large overlap with deep optical weak-lensing surveys that are being used to calibrate the SZ signal mass-scaling relation, such as the Dark Energy Survey (4566 deg 2 ), the Hyper Suprime-Cam Subaru Strategic Program (469 deg 2 ), and the Kilo Degree Survey (825 deg 2 ). We highlight some noteworthy objects in the sample, including potentially projected systems, clusters with strong lensing features, clusters with active central galaxies or star formation, and systems of multiple clusters that may be physically associated. The cluster catalog will be a useful resource for future cosmological analyses and studying the evolution of the intracluster medium and galaxies in massive clusters over the past 10 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploration of Options for Ultra-Fast Mass Spectroscopy for Pulsed Power Applications

Mega-ampere class pulsed power machines drive intense currents into small volumes to study high energy and density environments. Power lost during these events is a difficult and paramount problem to solve. For example, facilities such as Sandia National Laboratories’ Z machine experience meaningful power loss, which can be linked to non-linear ohmic heating at high currents (i.e., 26 MA on Z) leading to thermal desorption of contaminants and subsequent shunt plasma formation. Characterizing and understanding this type of thermal desorption is key to design optimizations necessary to minimize current loss, which will be even more important for next generation pulsed power. This type of characterization requires the ability to identify and determine concentration of analytes with nanosecond resolution given the pulse width of Z is on the order of 100 ns. This report summarizes progress on a small exploratory project focused on investigating options to meet this challenge using mass spectrometry. The main focus of these efforts utilized an Energy and Velocity Analyzer for Distributions of Electric Rockets intending to determine how quickly transient data could be resolved. This probe combines an electrostatic analyzer with a Wien velocity filter (ExB) to obtain ion energy and velocity distributions. Primary results from this exploratory project indicate significant additional work is needed to demonstrate a nanosecond time scale mass spectrometer for this application and also highlight that alternative detection methods such as laser-based diagnostics should be considered to meet the need for ultra-fast detection.

42 ENGINEERING↗

Solid particulate mass and number from ducted fuel injection in an optically accessible diesel engine in skip-fired operation

Ducted fuel injection (DFI) is a new combustion strategy that has been shown to significantly attenuate soot formation in diesel engines. While previous studies have used optical diagnostics and optical filter smoke number methods to show that DFI reduces in-cylinder soot formation and engine-out soot emissions, respectively, this is the first study to measure solid particle number (PN) emissions in addition to particle mass (PM). Furthermore, this study quantitatively evaluates the use of transient particle instruments for measuring particles from skip-fired operation in an optical single cylinder research engine (SCRE). Engine-out PN was measured using an engine exhaust particle sizer following a catalytic stripper, and PM was measured using a photoacoustic analyzer. The study improves on earlier preliminary emissions studies by clearly showing that DFI reduces overall PM by 76%–79% and PN for particles larger than 23 nm by 77% relative to conventional diesel combustion at a 1200-rpm, 13.3-bar gross indicated mean effective pressure operating condition. The degree of engine-out PM reduction with DFI was similar across both particulate measurement instruments used in the work. Through the use of bimodal distribution fitting, DFI was also shown to reduce the geometric mean diameter of accumulation mode particles by 26%, similar to the effects of increased injection pressure in conventional diesel combustion systems. This work clearly shows the significant solid particulate matter reductions enabled by DFI while also demonstrating that engine-out PN can be accurately measured from an optical SCRE operating in a skip-fired mode. Based on these results, it is believed that DFI has the potential to enable fuel savings when implemented in multi-cylinder engines, both by lowering the required frequency of active diesel particulate filter regeneration, and by reducing the backpressure imposed by exhaust filtration systems.

33 ADVANCED PROPULSION SYSTEMS↗

Real-time signal detection for Cyclotron Radiation Emission Spectroscopy measurements using antenna arrays

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40 meV, requiring a large supply of tritium atoms stored in a multi-cubic meter detector volume. Antenna arrays are one potential technology compatible with an experiment of this scale, but the capability of an antenna-based CRES experiment to measure the neutrino mass depends on the efficiency of the signal detection algorithms. Here, in this paper, we develop efficiency models for three signal detection algorithms and compare them using simulations from a prototype antenna-based CRES experiment as a case-study. The algorithms include a power threshold, a matched filter template bank, and a neural network based machine learning approach, which are analyzed in terms of their average detection efficiency and relative computational cost. It is found that significant improvements in detection efficiency and, therefore, neutrino mass sensitivity are achievable, with only a moderate increase in computation cost, by utilizing either the matched filter or machine learning approach in place of a power threshold, which is the baseline signal detection algorithm used in previous CRES experiments by Project 8.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GAINN: The Galaxy Assembly and Interaction Neural Networks for High-redshift JWST Observations

We present the Galaxy Assembly and Interaction Neural Networks (Gainn), a series of artificial neural networks for predicting the redshift, stellar mass, halo mass, and mass-weighted age of simulated galaxies based on James Webb Space Telescope (JWST) photometry. Our goal is to determine the best neural network for predicting these variables at 11 < z < 15. The parameters of the optimal neural network can then be used to estimate these variables for real, observed galaxies. The inputs of the neural networks are JWST filter magnitudes of a subset of five broadband filters (F150W, F200W, F277W, F356W, and F444W) and two medium-band filters (F162M and F182M). We compare the performance of the neural networks using different combinations of these filters, as well as different activation functions and numbers of layers. The best neural network predicted redshift with a normalized rms error of $0.010^{+0.003}_{-0.001}$, stellar mass with rms = $0.089^{+0.044}_{-0.022}$, halo mass with a mean-squared error of $0.022^{+0.014}_{-0.008}$, and mass-weighted age with rms = $12.466^{+5.065}_{-2.408}$. We also test the performance of Gainn on real data from MACS0647JD, an object observed by JWST. Predictions from Gainn for the first projection of the object (JD1) have normalized bias $\langle$Δz$\rangle$ < 0.00228, which is significantly smaller than found with template-fitting methods. We find that the optimal filter combination is F277W, F356W, F162M, and F200W when considering both theoretical accuracy and observational resources from JWST.

97 MATHEMATICS AND COMPUTING↗

Studies of Quark Transport and Hadronization in Nuclei

In this project, we conducted the first measurement of di‑hadron azimuthal correlations in deep inelastic scattering (DIS) off nuclei using the CLAS detector at Jefferson Lab. Using 5 GeV electron‑beam data collected on deuterium, carbon, iron, and lead targets, we extracted di‑pion correlation functions over a broad kinematic range. The results show a monotonic broadening of the correlation peak with increasing nuclear mass, along with pronounced dependencies on the pions’ kinematics. Separately, we implemented an algorithm based on the Kalman filter that achieved the first complete alignment of the CLAS12 central tracking system. In parallel, we developed simulations, algorithms, and performance studies that informed the conceptual designs of the forward hadronic calorimeter Insert and the Zero Degree Calorimeter, both of which are now included in the ePIC detector baseline for the forthcoming Electron Ion Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPARTAN and IMPROVE Comparison Experiment (SPICE) Interim Campaign Report

SPICE (the SPARTAN and IMPROVE Comparison Experiment) aims to obtain and quantify comparisons between aerosol PM 2.5 mass concentration measurements from the University of Oklahoma (OU) Surface Particulate Matter Network (SPARTAN) station and the U.S. Environmental Protection Agency (EPA) Interagency Monitoring of Protected Visual Environments (IMPROVE) station hosted by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility at ARM’s Southern Great Plains (SGP) observatory in Oklahoma. Aerosols—both natural and anthropogenic—affect human populations in multiple ways. Much of ARM’s research focuses on how aerosols influence weather and climate through their optical and radiative effects, as well as their impacts on clouds and precipitation. However, aerosols also pose direct risks to humans and other organisms through inhalation, with the severity of health impacts depending on particle size, chemical composition, and duration of exposure. The IMPROVE network was established by the U.S. EPA to monitor air quality, including visible clarity as well as total and chemically speciated aerosol mass concentrations. The ARM SGP site hosts the IMPROVE SOGP station. Separately, the SPARTAN network operates a globally distributed set of stations similar to IMPROVE but with an emphasis on remote deployment and semi-autonomous operation for use beyond the borders of the United States (IMPROVE only operates within the U.S.). The University of Oklahoma operates a SPARTAN station. To establish confidence in the OU SPARTAN instrumentation and measurement protocol relative to the EPA-certified IMPROVE station, the OU SPARTAN station is currently deployed at SGP in close proximity to the IMPROVE SOGP station. The SPICE campaign was envisioned as a contiguous calendar-year effort for 2025 to capture seasonal variation in mass loading as well as composition. However, independent of the SPICE campaign, the SPARTAN network adopted a new filter construction part-way through the year, interrupting our contiguous data set. Thus, to obtain a contiguous data set with a uniform consistent configuration, SPICE desires an extension through 2026.

54 ENVIRONMENTAL SCIENCES↗

Photometry and astrometry with JWST – III. A NIRCam-Gaia DR3 analysis of the open cluster NGC 2506

ABSTRACT In the third paper of this series aimed at developing the tools for analysing resolved stellar populations using the cameras on board of the James Webb Space Telescope (JWST), we present a detailed multiband study of the 2 Gyr Galactic open cluster NGC 2506. We employ public calibration data sets collected in multiple filters to: (i) derive improved effective Point Spread Functions (ePSFs) for 10 NIRCam filters; (ii) extract high-precision photometry and astrometry for stars in the cluster, approaching the main sequence (MS) lower mass of ∼0.1 M⊙; and (iii) take advantage of the synergy between JWST and Gaia DR3 to perform a comprehensive analysis of the cluster’s global and local properties. We derived a MS binary fraction of ∼57.5 per cent, extending the Gaia limit (∼0.8 M⊙) to lower masses (∼0.4 M⊙) with JWST. We conducted a study on the mass functions (MFs) of NGC 2506, mapping the mass segregation with Gaia data, and extending MFs to lower masses with the JWST field. We also combined information on the derived MFs to infer an estimate of the cluster present-day total mass. Lastly, we investigated the presence of white dwarfs (WDs) and identified a strong candidate. However, to firmly establish its cluster membership, as well as that of four other WD candidates and of the majority of faint low-mass MS stars, further JWST equally deep observations will be required. We make publicly available catalogues, atlases, and the improved ePSFs.

Nardiello, D. (ORCID:0000000311493659)↗

Lanczos Algorithm, the Transfer Matrix, and the Signal-to-Noise Problem

This Letter introduces a method for determining the energy spectrum of lattice quantum chromodynamics by applying the Lanczos algorithm to the transfer matrix and using a bootstrap generalization of the Cullum-Willoughby method to filter out spurious eigenvalues. Proof-of-principle analyses of the simple harmonic oscillator and the lattice quantum chromodynamics proton mass demonstrate that this method provides faster ground-state convergence than the “effective mass,” which is related to the power-iteration algorithm. Lanczos provides more accurate energy estimates than multistate fits to correlation functions with small imaginary times while achieving comparable statistical precision. Two-sided error bounds are computed for Lanczos results and guarantee that excited-state effects cannot shift Lanczos results far outside their statistical uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on Metastable Helium in the Atmospheres of WASP-69b and WASP-52b with Ultranarrowband Photometry

Infrared observations of metastable 2{sup 3}S helium absorption with ground- and space-based spectroscopy are rapidly maturing, as this species is a unique probe of exoplanet atmospheres. Specifically, the transit depth in the triplet feature (with vacuum wavelengths near 1083.3 nm) can be used to constrain the temperature and mass-loss rate of an exoplanet’s upper atmosphere. Here, we present a new photometric technique to measure metastable 2{sup 3}S helium absorption using an ultranarrowband filter (FWHM 0.635 nm) coupled to a beam-shaping diffuser installed in the Wide-field Infrared Camera on the 200 inch Hale Telescope at Palomar Observatory. We use telluric OH lines and a helium arc lamp to characterize refractive effects through the filter and to confirm our understanding of the filter transmission profile. We benchmark our new technique by observing a transit of WASP-69b and detect an excess absorption of 0.498% ± 0.045% (11.1σ), consistent with previous measurements after considering our bandpass. We then use this method to study the inflated gas giant WASP-52b and place a 95th percentile upper limit on excess absorption in our helium bandpass of 0.47%. Using an atmospheric escape model, we constrain the mass-loss rate for WASP-69b to be 5.25{sub −0.46}{sup +0.65}×10{sup −4} M{sub J} Gyr{sup −1} (3.32{sub −0.56}{sup +0.67}×10{sup −3} M{sub J} Gyr{sup −1}) at 7000 K (12,000 K). Additionally, we set an upper limit on the mass-loss rate of WASP-52b at these temperatures of 2.1×10{sup −4} M{sub J} Gyr{sup −1} (2.1×10{sup −3} M{sub J} Gyr{sup −1}). These results show that ultranarrowband photometry can reliably quantify absorption in the metastable helium feature.

79 ASTRONOMY AND ASTROPHYSICS↗