Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Mass Spectra of Some Perfluoroalkyl and Perfluoroalkylether Substituted 1,2,4-Oxadiazoles

Electron impact fragmentation patterns were obtained for 1,4-bis[(5-perfluoro-n-heptyl)-1,2,4-oxadiazolyl- benzene, its perfluoroalkylether substituted analogue, 3,5-bis(perfluoroalkyl)-, 3,5-bis(perfluoroalkylether)- and 3-perfluoroalkylether-5-perfluoroalkyl-1,2,4-oxadiazoles. In the compounds containing the phenylene group the molecular ion constituted the base peak; the main process was the breakdown of the oxadiazole ring with concurrent liberation of the perfluoroalkyl or perfluoroalkylether nitrile molecule; cleavage of the fluorinated chain ot to the oxadiazole ring was found to take place to a considerable degree. In the perfluorinated 1,2,4-oxadiazoles cleavage beta to the oxadiazole ring occurred preferentially; fragmentation of the ring itself took place to a limited degree only. The 3-perfluoroalkylether-5-perfluoroalkyl-1,2,4-oxadiazole appeared to undergo the primary beta-cleavage exclusively at the perfluoroalkylether sidechain.

Paciorek, Kazimiera J. L.↗

Evolved Late-Type Star FUV Spectra: Mass Loss and Fluorescence

This proposal was for a detailed analysis of the far ultraviolet (FUV) photoionizing radiation that provides crucial input physics for mass loss studies, e.g., observations of the flux below 10448, allow us to constrain the Ca II/Ca III balance and make significant progress beyond previous optical studies on stellar mass loss and circumstellar photochemistry. Our targets selection provided good spectral-type coverage required to help unravel the Ca II/Ca III balance as the mass-loss rates increase by over three orders of magnitude from K5 III to M5 III. We also explored the relationship between the FUV radiation field and other UV diagnostics to allow us to empirically estimate the FUV radiation field for the vast majority of stars which are too faint to be observed with FUSE, and to improve upon their uncertain mass-loss rates.

Harper, Graham M.↗

Dark matter interpretations of ATLAS searches for the electroweak production of supersymmetric particles in $ \sqrt{s}=8 $ TeV proton-proton collisions

A selection of searches by the ATLAS experiment at the LHC for the electroweak production of SUSY particles are used to study their impact on the constraints on dark matter candidates. The searches use 20 fb -1 of proton-proton collision data at √s=8 TeV. A likelihood-driven scan of a five-dimensional effective model focusing on the gaugino-higgsino and Higgs sector of the phenomenological minimal supersymmetric Standard Model is performed. This scan uses data from direct dark matter detection experiments, the relic dark matter density and precision flavour physics results. Further constraints from the ATLAS Higgs mass measurement and SUSY searches at LEP are also applied. A subset of models selected from this scan are used to assess the impact of the selected ATLAS searches in this five-dimensional parameter space. These ATLAS searches substantially impact those models for which the mass m($\tilde{χ}$$0\atop{1}$) of the lightest neutralino is less than 65 GeV, excluding 86% of such models. The searches have limited impact on models with larger m($\tilde{χ}$$0\atop{1}$) due to either heavy electroweakinos or compressed mass spectra where the mass splittings between the produced particles and the lightest supersymmetric particle is small.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser-Induced Acoustic Desorption/Electron Ionization of Amino Acids and Small Peptides

Laser-induced acoustic desorption (LIAD) allows for desorption of neutral nonvolatile compounds independent of their volatility or thermal stability. Many different ionization methods have been coupled with LIAD. Hence, this setup provides a better control over the types of ions formed than other mass spectrometry evaporation/ionization methods commonly used to characterize biomolecules, such as ESI or MALDI. In this study, the utility of LIAD coupled with electron ionization (EI) was tested for the analysis of common amino acids with no derivatization. The results compared favorably with previously reported EI mass spectra obtained using thermal desorption/EI. Further, LIAD/EI mass spectra collected for hydrochloride salts of two amino acids were found to be similar to those measured for the neutral amino acids with the exception of the appearance of an HCl{sup +●} ion. However, the hydrochloride salt of arginine showed a distinctly different LIAD/EI mass spectrum than the previously published literature EI mass spectrum, likely due to its highly basic side chain that makes a specific zwitterionic form particularly favorable. Finally, EI mass spectra were measured for seven small peptides, including di-, tri-, and tetrapeptides. These mass spectra show a variety of ion types. However, a{sub n} type ions are prevalent. Also, electron-induced dissociation (EID) of protonated peptides has been reported to form primarily a{sub n} type ions. In addition, the loss of small neutral molecules and side-chain cleavages were observed that are reminiscent of other high-energy fragmentation methods, such as EID. Finally, the isomeric dipeptides LG and IG were found to produce drastically different EI mass spectra, thus allowing differentiation of the leucine and isoleucine amino acids in these dipeptides. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Residual Gas Analyzer Calibration

A technique which employs known gas mixtures to calibrate the residual gas analyzer (RGA) is described. The mass spectra from the RGA are recorded for each gas mixture. This mass spectra data and the mixture composition data each form a matrix. From the two matrices the calibration matrix may be computed. The matrix mathematics requires the number of calibration gas mixtures be equal to or greater than the number of gases included in the calibration. This technique was evaluated using a mathematical model of an RGA to generate the mass spectra. This model included shot noise errors in the mass spectra. Errors in the gas concentrations were also included in the valuation. The effects of these errors was studied by varying their magnitudes and comparing the resulting calibrations. Several methods of evaluating an actual calibration are presented. The effects of the number of gases in then, the composition of the calibration mixture, and the number of mixtures used are discussed.

R H Lilienkamp↗

Combinatorial Labeling Method for Improving Peptide Fragmentation in Mass Spectrometry

Annotation of peptide sequence from tandem mass spectra constitutes the central step of mass spectrometry-based proteomics. Peptide mass spectra are obtained upon gas-phase fragmentation. Identification of the protein from a set of experimental peptide spectral matches is usually referred as protein inference. Occurrence and intensity of these fragment ions in the MS/MS spectra are dependent on many factors such as amino acid composition, peptide basicity, activation mode, protease, etc. Particularly, chemical derivatizations of peptides were known to alter their fragmentation. In this study, the influence of acetylation, guanidinylation, and their combination on peptide fragmentation was assessed initially on a lipase (LipA) from Bacillus subtilis followed by a bovine six protein mix digest. The dual modification resulted in improved fragment ion occurrence and intensity changes, and this resulted in the equivalent representation of b- and y-type fragment ions in an ion trap MS/MS spectrum. The improved representation has allowed us to accurately annotate the peptide sequences de novo. Dual labeling has significantly reduced the false positive protein identifications in standard bovine six peptide digest. Our study suggests that the combinatorial labeling of peptides is a useful method to validate protein identifications for high confidence protein inference. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Characterization of High Molecular Weight Polyesters by Matrix-Assisted Laser Desorption/Ionization High-Resolution Time-of-Flight Mass Spectrometry Combined with On-plate Alkaline Degradation and Mass Defect Analysis

Matrix-assisted laser desorption ionization high-resolution time-of-flight mass spectrometry (MALDI HR TOF MS) is a powerful tool for the molecular characterization of industrial polymers. However, accurate mass determination and resolution of isobaric ions are possible for oligomer samples only typically below m/z 3000. To cut long polymer chains into oligomers suitable for high-resolution mass spectrometry, we propose a simple “on-plate” alkaline degradation of polyesters as a sample pretreatment technique prior to the MALDI TOF MS measurement. This pretreatment can be performed on a MALDI target using a small amount of sample (μg or less) and 1 μL of alkaline reagent by simple pipetting. Informative mass spectra in the oligomeric mass range are successfully recorded but complicated by the variation of end-groups and the copolymeric composition of the degradation products. Data processing is assisted by a series of advanced Kendrick mass defect (KMD) analyses recently proposed by the authors to plot visually understandable two-dimensional maps. On-plate degradation pretreatment, high-resolution MALDI TOF MS measurements, and advanced KMD analyses are innovatively combined for the compositional characterization of bacterial poly(3-hydroxybutyric acid-co-3-hydroxyvaleric acid) and industrial poly(ethylene terephthalate) samples. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Eliminating Artifacts in Electrospray Deconvolution with a SoftMax Function

UniDec provides a rapid and robust approach to deconvolving electrospray mass spectra into their corresponding mass and charge components. However, the UniDec algorithm can produce artifacts depending on the quality and complexity of the data. Here, a SoftMax function is applied to the charge state distribution of each data point, which pushes the algorithm towards assigning each data point to one primary charge state. As shown for several data sets of increasing complexity, the SoftMax function significantly reduces deconvolution artifacts, even for data with overlapping charge states. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of relative humidity on the heterogeneous oxidation of secondary organic aerosol

Abstract. Secondary organic aerosol (SOA) is a complex mixture of hundreds of semi-volatile to extremely low-volatility organic compounds that are chemically processed in the atmosphere, including via heterogeneous oxidation by gas-phase radicals. Relative humidity (RH) has a substantial impact on particle phase, which can affect how SOA evolves in the atmosphere. In this study, SOA from dark α -pinene ozonolysis is heterogeneously aged by OH radicals in a flow tube at low and high RH. At high RH (RH = 89 %) there is substantial loss of particle volume (~60 %) at an equivalent atmospheric OH exposure of 3 weeks. In contrast, at low RH (RH = 25 %) there is little mass loss (< 20 %) at the same OH exposure. Mass spectra of the SOA particles were measured as a function of OH exposure using a vacuum ultraviolet aerosol mass spectrometer (VUV-AMS). The mass spectra observed at low RH overall exhibit minor changes with oxidation and negligible further changes above an OH exposure = 2×10 12 molecule cm -3 s suggesting limited impact of oxidation on the particle composition. In contrast, the mass spectra observed at high RH exhibit substantial and continuous changes as a function of OH exposure. Further, at high RH clusters of peaks in the mass spectra exhibit unique decay patterns, suggesting different responses of various species to oxidation. A model of heterogeneous oxidation has been developed to understand the origin of the difference in aging between the low- and high-RH experiments. Differences in diffusivity of the SOA between the low- and high-RH experiments alone can explain the difference in compositional change but cannot explain the difference in mass loss. Instead, the difference in mass loss is attributable to RH-dependent differences in the OH uptake coefficient and/or the net probability of fragmentation, with either or both larger at high RH compared to low RH. These results illustrate the important impact of relative humidity on the fate of SOA in the atmosphere.

Li, Ziyue (ORCID:0000000191017737)↗

MolDiscovery: learning mass spectrometry fragmentation of small molecules

Identification of small molecules is a critical task in various areas of life science. Recent advances in mass spectrometry have enabled the collection of tandem mass spectra of small molecules from hundreds of thousands of environments. To identify which molecules are present in a sample, one can search mass spectra collected from the sample against millions of molecular structures in small molecule databases. The existing approaches are based on chemistry domain knowledge, and they fail to explain many of the peaks in mass spectra of small molecules. Here, we present molDiscovery, a mass spectral database search method that improves both efficiency and accuracy of small molecule identification by learning a probabilistic model to match small molecules with their mass spectra. A search of over 8 million spectra from the Global Natural Product Social molecular networking infrastructure shows that molDiscovery correctly identify six times more unique small molecules than previous methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on Cosmology and Baryonic Feedback with the Deep Lens Survey Using Galaxy–Galaxy and Galaxy–Mass Power Spectra

We present cosmological parameter measurements from the Deep Lens Survey (DLS) using galaxy–mass and galaxy–galaxy power spectra in the multipole range ℓ = 250–2000. We measure galaxy–galaxy power spectra from two lens bins centered at z ~ 0.27 and 0.54 and galaxy–mass power spectra by cross-correlating the positions of galaxies in these two lens bins with galaxy shapes in two source bins centered at z ~ 0.64 and 1.1. We marginalize over a baryonic feedback process using a single-parameter representation and a sum of neutrino masses, as well as photometric redshift and shear calibration systematic uncertainties. For a flat ΛCDM cosmology, we determine ${S}_{8}\equiv {\sigma }_{8}\sqrt{{{\rm{\Omega }}}_{m}/0.3}={0.810}_{-0.031}^{+0.039}$, in good agreement with our previous DLS cosmic shear and the Planck cosmic microwave background (CMB) measurements. Without the baryonic feedback marginalization, S 8 decreases by $\sim 0.05$ because the dark-matter-only power spectrum lacks the suppression at the highest ℓ values owing to active galactic nucleus (AGN) feedback. Together with the Planck CMB measurements, we constrain the baryonic feedback parameter to ${A}_{\mathrm{baryon}}={1.07}_{-0.39}^{+0.31}$, which suggests an interesting possibility that the actual AGN feedback might be stronger than the recipe used in the OverWhelmingly Large cosmological hydrodynamical Simulations. The interpretation is limited by the validity of the baryonic feedback simulation and the one-parameter representation of the effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Mass Spectrometry of a Xylitol Molecule

The technique and results of a mass spectrometric study on the yield of positive ions formed upon ionization of xylitol molecules by electron impact are discussed. The mass spectra of xylitol are studied in the range of mass numbers of 10–160 Da and in the range of bombarding electrons energies of 5–80 eV. Based on the analysis of the measured mass spectra, a scheme of xylitol fragmentation is proposed, which contains the most probable channels of formation of ion-fragments upon electron impact, when the energy of the incident electrons significantly exceeds the ionization potential of the molecule. The appearance energies of ionized fragments of xylitol are determined for the first time from the energy dependences of the effective cross-section formation of the ions upon electron impact. The dynamics of ionized fragment formation is studied in the temperature range of the initial substance evaporation of 340–410 K. The behavior of the temperature dependence indicates that the formation processes of water and oxonium cations compete with each other.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas-Phase Chemistry in the GC Orbitrap Mass Spectrometer

Gas-phase reactions of temporally stored ions play a significant role in trapped ion mass spectrometry. Especially highly labile ion species generated through electron ionization (EI) are prone to undergo gas-phase reactions after relaxation to a low vibrational state. Here, we show that in the C-Trap of the Q Exactive GC Orbitrap mass spectrometer, gaseous water reacts with radical cations of various compound classes. High-resolution accurate mass spectrometry of the resulting ions provides a key to the mechanistic understanding of the chemistry of high energetic species generated during EI. We systematically addressed water adduct formation by use of H{sub 2}O and D{sub 2}{sup 18}O in the C-Trap. Mass spectra of halogen cyanides XCN (X=Cl, Br, I) showed the formation of HXCN{sup +} species, indicating hydrogen atomic transfer reactions. Relative ratios of HXCN{sup +}/XCN{sup +•} increased as the electronegativity of the halide increased. The common internal calibrant perfluorotributylamine forms oxygenated products from water reactive fragment ions. These can be explained by the addition of water to an initial cation followed by elimination of two HF molecules. This addition/elimination chemistry can also explain [M+2]{sup +} and [M+3]{sup +} ions that commonly occur in mass spectra of silylated analytes. High-resolution accurate mass spectra of trimethylsilyl (TMS) derivatives revealed these as [M−CH{sub 3}{sup •}+H{sub 2}O]{sup +} and [M−CH{sub 4}+H{sub 2}O]{sup •+}, respectively. This study explains common fragment ions in ion trap mass spectrometry. It also opens up perspectives for the systematic mechanistic and kinetic investigation of high-energy ion reactivity. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Liquid Extraction Surface Analysis (LESA) Electron-Induced Dissociation and Collision-Induced Dissociation Mass Spectrometry of Small Molecule Drug Compounds

Here, we present liquid extraction surface analysis (LESA) coupled with electron-induced dissociation (EID) mass spectrometry in a Fourier-transform ion cyclotron resonance mass spectrometer for the analysis of small organic pharmaceutical compounds directly from dosed tissue. First, the direct infusion electrospray ionisation EID and collision-induced dissociation (CID) behaviour of erlotinib, moxifloxacin, clozapine and olanzapine standards were compared. EID mass spectra were also compared with experimental or reference electron impact ionisation mass spectra. The results show that (with the exception of erlotinib) EID and CID result in complementary fragment ions. Subsequently, we performed LESA EID MS/MS and LESA CID MS/MS on singly charged ions of moxifloxacin and erlotinib extracted from a thin tissue section of rat kidney from a cassette-dosed animal. Both techniques provided structural information, with the majority of peaks observed for the drug standards also observed for the tissue-extracted species. Overall, these results demonstrate the feasibility of LESA EID MS/MS of drug compounds from dosed tissue and extend the number of molecular structures for which EID behaviour has been determined. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoinduced Charge Transfer versus Fragmentation Pathways in Lanthanum Cyclopentadienyl Complexes

This study compares two competing pathways of photoexcitations in gas-phase metal–organic complexes: first, a sequence of phonon-assisted electronic transitions leading to dissipation of the energy of photoexcitations and, second, a sequence of light-driven electronic transitions leading to photolysis. Phonon-assisted charge carrier dynamics is investigated by combination of the density matrix formalism and on-the-fly nonadiabatic couplings. Light-driven fragmentation is modeled by a time-dependent excited-state molecular-dynamics (TDESMD) algorithm based on Rabi theory and principles similar to the trajectory surface hopping approximation. Numerical results indicate that, under the medium intensity of the laser field, light-driven electronic transitions are more probable than phonon-assisted ones. The formation of multiple products is observed in TDESMD trajectories. Simulated mass spectra are extracted from TDESMD simulations and compared to experimental photoionization time-of-flight (PI-TOF) mass spectra. It is found that several features in the experimental mass spectra are reproduced by the simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compositional Measurements of Saturn's Upper Atmosphere and Rings From Cassini INMS: An Extended Analysis of Measurements From Cassini's Grand Finale Orbits

The Cassini spacecraft's final orbits sampled Saturn's atmosphere and returned surprisingly complex mass spectra from the Ion and Neutral Mass Spectrometer (INMS). Signal returned from the instrument included native Saturn species, as expected, as well as a significant amount of signal attributed to vaporized ices and higher mass organics believed to be owing into Saturn's atmosphere from the rings. In this paper, we present an in-depth compositional analysis of the mass spectra returned from Cassini's last few orbits. We use a mass spectral deconvolution algorithm designed specifically to handle the complexities involved with unit resolution spaceflight mass spectrometry data to determine the relative abundance of species detected in the observations. We calculate the downward external flux and mass deposition rates of ring volatile species into Saturn's atmosphere and conclude that during these observations ring material was being deposited into Saturn's equatorial region at a rate on the order of 10(exp 4) kg/s.

Saturn↗

Compositional Measurements of Saturn's Upper Atmosphere and Rings From Cassini INMS: An Extended Analysis of Measurements From Cassini's Grand Finale Orbits

The Cassini spacecraft's final orbits sampled Saturn's atmosphere and returned surprisingly complex mass spectra from the Ion and Neutral Mass Spectrometer (INMS). Signal returned from the instrument included native Saturn species, as expected, as well as a significant amount of signal attributed to vaporized ices and higher mass organics believed to be flowing into Saturn's atmosphere from the rings. In this paper, we present an in-depth compositional analysis of the mass spectra returned from Cassini's last few orbits. We use a mass spectral deconvolution algorithm designed specifically to handle the complexities involved with unit resolution spaceflight mass spectrometry data to determine the relative abundance of species detected in the observations. We calculate the downward external flux and mass deposition rates of ring volatile species into Saturn's atmosphere and conclude that during these observations ring material was being deposited into Saturn's equatorial region at a rate on the order of 10(exp 4) kg/s.

Saturn↗