Attention-Based Fusion of Infrared and Mass Spectra for Identification of Chemical Threats BY Functional Group Prediction
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract Not Provided
Abstract not provided.
Abstract not provided.
A selection of searches by the ATLAS experiment at the LHC for the electroweak production of SUSY particles are used to study their impact on the constraints on dark matter candidates. The searches use 20 fb -1 of proton-proton collision data at √s=8 TeV. A likelihood-driven scan of a five-dimensional effective model focusing on the gaugino-higgsino and Higgs sector of the phenomenological minimal supersymmetric Standard Model is performed. This scan uses data from direct dark matter detection experiments, the relic dark matter density and precision flavour physics results. Further constraints from the ATLAS Higgs mass measurement and SUSY searches at LEP are also applied. A subset of models selected from this scan are used to assess the impact of the selected ATLAS searches in this five-dimensional parameter space. These ATLAS searches substantially impact those models for which the mass m($\tilde{χ}$$0\atop{1}$) of the lightest neutralino is less than 65 GeV, excluding 86% of such models. The searches have limited impact on models with larger m($\tilde{χ}$$0\atop{1}$) due to either heavy electroweakinos or compressed mass spectra where the mass splittings between the produced particles and the lightest supersymmetric particle is small.
Laser-induced acoustic desorption (LIAD) allows for desorption of neutral nonvolatile compounds independent of their volatility or thermal stability. Many different ionization methods have been coupled with LIAD. Hence, this setup provides a better control over the types of ions formed than other mass spectrometry evaporation/ionization methods commonly used to characterize biomolecules, such as ESI or MALDI. In this study, the utility of LIAD coupled with electron ionization (EI) was tested for the analysis of common amino acids with no derivatization. The results compared favorably with previously reported EI mass spectra obtained using thermal desorption/EI. Further, LIAD/EI mass spectra collected for hydrochloride salts of two amino acids were found to be similar to those measured for the neutral amino acids with the exception of the appearance of an HCl{sup +●} ion. However, the hydrochloride salt of arginine showed a distinctly different LIAD/EI mass spectrum than the previously published literature EI mass spectrum, likely due to its highly basic side chain that makes a specific zwitterionic form particularly favorable. Finally, EI mass spectra were measured for seven small peptides, including di-, tri-, and tetrapeptides. These mass spectra show a variety of ion types. However, a{sub n} type ions are prevalent. Also, electron-induced dissociation (EID) of protonated peptides has been reported to form primarily a{sub n} type ions. In addition, the loss of small neutral molecules and side-chain cleavages were observed that are reminiscent of other high-energy fragmentation methods, such as EID. Finally, the isomeric dipeptides LG and IG were found to produce drastically different EI mass spectra, thus allowing differentiation of the leucine and isoleucine amino acids in these dipeptides. .
The sampling, ionization and detection of tryptic peptides separated in one-dimension on reversed phase HPTLC plates was performed using liquid microjunction surface sampling probe electrospray ionization mass spectrometry. Tryptic digests of five proteins (cytochrome c., myoglobin, beta-casein, lysozyme, and bovine serum albumin) were spotted on reversed phase HPTLC RP-8 F254s and HPTLC RP-18 F254s plates. The plates were then developed using 70/30 methanol/water with 0.1 M ammonium acetate. A dual purpose extraction/electrospray solution containing 70/30/0.1 water/methanol/formic acid was infused through the sampling probe during analysis of the developed lanes. Both full scan mass spectra and data dependent tandem mass spectra were acquired for each development lane to detect and verify the peptide distributions. Data dependent tandem mass spectra provided both protein identification and sequence coverage information. Highest sequence coverages were achieved for cytochrome c. and myoglobin (62.5% and 58.3%, respectively) on reversed phase RP-8 plates. While the tryptic peptides were separated enough for identification, the peptide bands did show some overlap with most peptides located in the lower half of the development lane. Proteins whose peptides were more separated gave higher sequence coverage. Larger proteins such as beta-casein and BSA which were spotted in lower relative amounts gave much lower sequence coverage than the smaller proteins.
Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS)-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting these data uses the mass spectra to infer masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as raw data readers, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls.
The light vector mesons ({rho},{omega}, and {phi}) were produced in deuterium, carbon, titanium, and iron targets in a search for possible in-medium modifications to the properties of the {rho} meson at normal nuclear densities and zero temperature. The vector mesons were detected with the CEBAF Large Acceptance Spectrometer (CLAS) via their decays to e{sup +}e{sup -}. The rare leptonic decay was chosen to reduce final-state interactions. A combinatorial background was subtracted from the invariant mass spectra using a well-established event-mixing technique. The {rho}-meson mass spectrum was extracted after the {omega} and {phi} signals were removed in a nearly model-independent way. Comparisons were made between the {rho} mass spectra from the heavy targets (A>2) with the mass spectrum extracted from the deuterium target. With respect to the {rho}-meson mass, we obtain a small shift compatible with zero. Also, we measure widths consistent with standard nuclear many-body effects such as collisional broadening and Fermi motion.
We present spectra and mass composition of cosmic rays incoming to the Earth in the energy range (0.5−2)·10{sup 20} eV. As their sources we consider Seyfert galaxies located at distances ∼<40 Mpc, following an acceleration model for such moderate-power objects. Mass composition of the particles at sources is assumed to be mixed. Generation spectra are described by a function E{sup −γ{sub 0}}, where γ{sub 0} is an arbitrary parameter. It is shown that the assumptions adopted make it possible to describe experimental data provided by HiRes and Pierre Auger Observatory, using different values of γ{sub 0}.
PTMSearchPlus is a software tool for the automated integration of accurate intact protein mass (AIPM) and bottom-up (BU) mass spectra searches/data in order to both confidently identify the intact proteins and to characterize their post-translational modifications (PTMs). The development of PTMSearchPlus was motivated by the desire to effectively integrate high-resolution intact protein molecular masses with bottom-up peptide MS/MS data. PTMSearchPlus requires as input both intact protein and proteolytic peptide mass spectra collected from the same protein mixture, a FASTA protein database, and a selection of possible PTMs, the types and ranges of which can be specified. The output of PTMSearchPlus is a list of intact and modified proteins matching the AIPM data concomitant with their respective peptides found by the BU search. This list also contains protein and peptide sequence coverage information, scores, etc. that can be used for further evaluation or refiltering of the results. Corresponding and annotated AIPM and BU mass spectra are also displayed for visual inspection when a listed protein or a peptide is selected. These and other controls ensure that the user can manually evaluate, modify (e.g., remove obvious false positives, low quality spectra etc.), and save the results of the automated search if necessary. Driven by the exponential growth in the number of possible peptide candidates in a BU search when multiple PTMs are probed, the advantages on search speed by limiting the total number of possible PTMs on a peptide in the BU search or by performing an AIPM predicted BU search are also discussed in addition to the integration approach. The features of PTMSearchPlus are demonstrated using both a protein standard mixture and a complex protein mixture from Escherichia coli. Experimental data revealed a unique advantage of coupling AIPM and the BU data sets that is mutually beneficial for both approaches. Namely, AIPM data can confirm that no PTM peptides were missed in a BU search, while the BU search determines the location of the PTM. This information is not available using an AIPM search alone.
We report suitable secondary ion (SI) counting for surface-sensitive chemical analysis of organic compounds using time-of-flight (TOF) SI mass spectroscopy, based on considerably higher emission yields of SIs induced by cluster ion impact ionization. A SI counting system for a TOF SI mass spectrometer was developed using a fast digital storage oscilloscope, which allows us to perform various types of analysis as all the signal pulses constituting TOF SI mass spectra can be recorded digitally in the system. Effects of the SI counting strategy on SI mass spectra were investigated for C{sub 8} and C{sub 60} cluster ion impacts on an organically contaminated silicon wafer and on polytetrafluoroethylene targets by comparing TOF SI mass spectra obtained from the same recorded signals with different SI counting procedures. Our results show that the use of a counting system, which can cope with high SI yields, is necessary for quantitative analysis of SI mass spectra obtained under high SI yield per impact conditions, including the case of cluster ion impacts on organic compounds.
Desorption electrospray ionization mass spectrometry was investigated as a method to detect and identify peptides from tryptic digests of cytochrome c and myoglobin separated on ProteoChrom HPTLC Silica gel 60 F254s plates and ProteoChrom HPTLC Cellulose sheets. Both full scan mass spectra and data-dependent tandem mass spectra were acquired in separate plate scans and used to identify peptide ions. Peptide distributions along the development lane were mapped for each separated protein digest. Signal levels ranged over several orders of magnitude. In general, highest signal levels were obtained for the peptides with the highest Rf values on a plate, while peptides with very low Rf values were often not detected. Sequence coverages for cytochrome c were 58% for the digest separated on the silica gel plate and 72% for the separation on the cellulose sheet; myoglobin sequence coverages were 62% and 68% on silica gel and cellulose, respectively. Weak correlations between peptide hydrophilicity and Rf values on the silica gel and cellulose plates were found, with more hydrophilic peptides having lower Rf values.
Annotation of peptide sequence from tandem mass spectra constitutes the central step of mass spectrometry-based proteomics. Peptide mass spectra are obtained upon gas-phase fragmentation. Identification of the protein from a set of experimental peptide spectral matches is usually referred as protein inference. Occurrence and intensity of these fragment ions in the MS/MS spectra are dependent on many factors such as amino acid composition, peptide basicity, activation mode, protease, etc. Particularly, chemical derivatizations of peptides were known to alter their fragmentation. In this study, the influence of acetylation, guanidinylation, and their combination on peptide fragmentation was assessed initially on a lipase (LipA) from Bacillus subtilis followed by a bovine six protein mix digest. The dual modification resulted in improved fragment ion occurrence and intensity changes, and this resulted in the equivalent representation of b- and y-type fragment ions in an ion trap MS/MS spectrum. The improved representation has allowed us to accurately annotate the peptide sequences de novo. Dual labeling has significantly reduced the false positive protein identifications in standard bovine six peptide digest. Our study suggests that the combinatorial labeling of peptides is a useful method to validate protein identifications for high confidence protein inference. .
The fragmentation mechanisms of monolignols under various energetic processes are studied with jet-cooled thermal desorption molecular beam (TDMB) mass spectrometry (MS), 25 keV Bi3+ secondary ion MS (SIMS), synchrotron vacuum-ultraviolet secondary neutral MS (VUV-SNMS) and theoretical methods. Experimental and calculated appearance energies of fragments observed in TDMB MS indicate that the coniferyl alcohol photoionization mass spectra contain the molecular parent and several dissociative photoionization products. Similar results obtained for sinapyl alcohol are also discussed briefly. Ionization energies of 7.60 eV ? 0.05 eV for coniferyl alcohol and<7.4 eV for both sinapyl and dihydrosinapyl alcohols are determined. The positive ion SIMS spectrum of coniferyl alcohol shares few characteristic peaks (m/z = 137 and 151) with the TDMB mass spectra, shows extensive fragmentation, and does not exhibit clear molecular parent signals. VUV-SNMS spectra, on the other hand, are dominated by the parent ion and main fragments also present in the TDMB spectra. Molecular fragmentation in VUV-SNMS spectra can be reduced by increasing the extraction delay time. Some features resembling the SIMS spectra are also observed in the desorbed neutral products. The monolignol VUV-SNMS peaks shared with the TDMB mass spectra suggest that dissociative photoionization of ion-sputtered neutral molecules predominate in the VUV-SNMS mass spectra, despite the extra internal energy imparted in the initial ion impact. The potential applications of these results to imaging mass spectrometry of bio-molecules are discussed.
Matrix-assisted laser desorption ionization high-resolution time-of-flight mass spectrometry (MALDI HR TOF MS) is a powerful tool for the molecular characterization of industrial polymers. However, accurate mass determination and resolution of isobaric ions are possible for oligomer samples only typically below m/z 3000. To cut long polymer chains into oligomers suitable for high-resolution mass spectrometry, we propose a simple “on-plate” alkaline degradation of polyesters as a sample pretreatment technique prior to the MALDI TOF MS measurement. This pretreatment can be performed on a MALDI target using a small amount of sample (μg or less) and 1 μL of alkaline reagent by simple pipetting. Informative mass spectra in the oligomeric mass range are successfully recorded but complicated by the variation of end-groups and the copolymeric composition of the degradation products. Data processing is assisted by a series of advanced Kendrick mass defect (KMD) analyses recently proposed by the authors to plot visually understandable two-dimensional maps. On-plate degradation pretreatment, high-resolution MALDI TOF MS measurements, and advanced KMD analyses are innovatively combined for the compositional characterization of bacterial poly(3-hydroxybutyric acid-co-3-hydroxyvaleric acid) and industrial poly(ethylene terephthalate) samples. .
UniDec provides a rapid and robust approach to deconvolving electrospray mass spectra into their corresponding mass and charge components. However, the UniDec algorithm can produce artifacts depending on the quality and complexity of the data. Here, a SoftMax function is applied to the charge state distribution of each data point, which pushes the algorithm towards assigning each data point to one primary charge state. As shown for several data sets of increasing complexity, the SoftMax function significantly reduces deconvolution artifacts, even for data with overlapping charge states. .