Report of test on multicoder environmental tests
Electrical measurements, and environmental test data on multicoder
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Electrical measurements, and environmental test data on multicoder
Many pieces of the puzzle must be brought together in order to have a clear picture of the near-Earth object (NEO) population. Four of the pieces that can be described include: i) the taxonomic distribution of the population as measured by observational sampling, ii) the determination of albedos that can be associated with the taxonomic distribution, iii) discovery statistics for the NE0 population, and iv) the debiasing of the discovery statistics using the taxonomic and albedo information. Support from this grant enables us to address three of these four pieces. Binzel et al. (2004, submitted) presents the first piece, detailing the observations and observed characteristics of the NE0 and Mars-crossing (MC) population. For the second piece, a complementary program of albedo measurements is pursued at the Keck Observatory (Binzel, P. I.) with first results published in Delbo et al. (2003). For the third piece, the most extensive NE0 discovery statistics are provided by the LINEAR survey. Binzel has supervised the MIT Ph. D. thesis work of Stuart (2003) to bring the fourth piece, submitted for publication by Stuart and Binzel (2004). Our results provide new constraints for the NE0 population and progress for the Spaceguard Survey, illuminate asteroid and comet source regions for the NEOs, and provide new evidence for space weathering processes linking asteroids and meteorites. Further, we are identifying top priority near-Earth spacecraft mission candidates based on their spectral properties and inferred compositions.
Under the U.S.-Russian Material Protection, Control and Accounting (MPC&A) Program, the Material Control and Accounting Measurements (MCAM) Project has supported a joint U.S.-Russian effort to coordinate improvements of the Russian MC&A measurement system. These efforts have resulted in the development of a MC&A Equipment and Methodological Support (MEMS) Strategic Plan (SP), developed by the Russian MEM Working Group. The MEMS SP covers implementation of MC&A measurement equipment, as well as the development, attestation and implementation of measurement methodologies and reference materials at the facility and industry levels. This paper provides an overview of the activities conducted under the MEMS SP, as well as a status on current efforts to develop reference materials, implement destructive and nondestructive assay measurement methodologies, and implement sample exchange, scrap and holdup measurement programs across Russian nuclear facilities.
We developed a scheme for finding the front boundary of an interplanetary magnetic cloud (MC) based on criteria that depend on the possible existence of any one or all of six specific solar wind features. The features that the program looks for, within +/- 2 hours of a preliminarily determined time for the front boundary, estimated either by visual inspection or by an automatic MC identification scheme, are: (1) a sufficiently large directional discontinuity in the interplanetary magnetic field (IMF), (2) existence of a magnetic hole, (3) a significant proton plasma beta drop, (4) a significant proton temperature drop, (5) a marked increase in the IMF's intensity, and (6) a significant decrease in a normalized root-mean-square deviation (RMS)of the magnetic field - where the scheme was tested using 5, 10, 15, and 20 minute averages of the relevant physical quantities, in order to find the optimum average (and RMS) to use. Other criteria, besides these six, were examined and dismissed as not reliable, e.g., plasma speed. The scheme was developed specifically for aiding in forecasting the strength and timing of a geomagnetic storm due to the passage of an interplanetary MC in real-time, but can be used in post ground-data collection for imposition of consistency in choosing a MC's front boundary. The scheme has been extensively tested, first using 80 bona fide MCs over about 9 years of WIND data, and also for 121 MC-like structures as defined by a program that automatically identifies such structures over the same period. Optimum limits for various parameters in the scheme were found by statistical studies of the WIND MCs. The resulting limits can be user-adjusted for other data sets, if desired. Final testing of the 80 MCs showed that for 50 percent of the events the boundary estimates occurred within +/-10 minutes of visually determined times, 80 percent occurred within +/-30 minutes, and 91 percent occur within +/-60 minutes, and three or more individual boundary tests were passed for 88 percent of the total MCs. The scheme and its testing will be described.
The RS-84 is the first reusable hydrocarbon staged combustion liquid rocket engine. This engine is being developed to meet NASA s crew safety goals with a highly reliable and low cost main engine as a part of the NASA Space Launch Initiative program for the next generation reusable launch system. The NASA-MSFC and Rocketdyne team brings over 50 years of successful rocket engine development experience to meet the challenges of this new program. This team s extensive design database has been anchored with almost five decades of hydrocarbon rocket engine development and flight operations experience including Delta, Atlas, and Saturn vehicles and nearly three decades of successfully operating the world s only reusable pump-fed rocket engine, the Space Shuttle Main Engine. The team also fully benefits from the proven and experienced engineering staffs that recently completed the successful MC-1 FASTRAC , XRS-2200, and RS-68 engine development programs and the ongoing IPD and RS-76 technology development. Advances in integrated parametric design and analysis tools, advanced materials knowledge base, and state-of-the-art fabrication processes anchored and refined during the recent engine development programs are already being used by the team to design this engine.
Digital computer programs including external display testing, symbolic paper tape editing, and real time star tracking
Computer programs to simulate and translate chosen computer design in Chu computer design language into Boolean equations
Achievements of application technology satellites, communication satellites, navigation and traffic control satellite program, weather satellites, and satellite geodesy
Meteoroid penetration detector development program
Purpose: This study assesses the accuracy of the absorbed dose estimates from CT scans generated by Monte Carlo (MC) simulation using a commercially available radiation dose monitoring software program. Methods: Axial CT studies of an anthropomorphic abdomen phantom with dose bores at a central location and 4 peripheral locations were conducted using a fixed tube current at 120 kV. A 100 mm ion chamber and a 0.6 cc ion chamber calibrated at diagnostic energy levels were used to measure dose in the phantom at each of the 5 dose bore locations. Simulations using the software program's Monte Carlo engine were run using a mathematical model of the anthropomorphic phantom to determine conversion coefficients between the CTDIvol used for the study and the dose at the location of the dose bores. Simulations were conducted using both the software's generic CT beam model and a refined model generated using HVL and bow tie filter profile measurements made on the scanner used for the study. Results: Monte Carlo simulations completed using the generalized beam model differed from the measured conversion factors by an absolute value average of 13.0% and 13.8% for the 100 mm and 0.6 cc ion chamber studies, respectively. The MC simulations using the scanner specific beam model generated conversion coefficients that differed from the CTDIvol to measured dose conversion coefficients by an absolute value average of 7.3% and 7.8% for the 100 mm and 0.6 cc ion chamber cases, respectively. Conclusion: A scanner specific beam model used in MC simulations generates more accurate dose conversion coefficients in an anthropomorphic phantom than those generated with a generalized beam model. Agreement between measured conversion coefficients and simulated values were less than 20% for all positions using the universal beam model.
The Material Protection, Control and Accounting (MPC&A) Program has been working since 1994 with nuclear sites in Russia to upgrade the physical protection (PP) and material control and accounting (MC&A) functions at facilities containing weapons usable nuclear material. In early 2001, the MPC&A program initiated the MPC&A Operations Monitoring (MOM) Project to monitor facilities where MPC&A upgrades have been installed to provide increased confidence that personnel are present and vigilant, provide confidence that security procedures are being properly performed and provide additional assurance that nuclear materials have not been stolen. The MOM project began as a pilot project at the Moscow State Engineering Physics Institute (MEPhI) and a MOM system was successfully installed in October 2001. Following the success of the MEPhI pilot project, the MPC&A Program expanded the installation of MOM systems to several other Russian facilities, including the JSC 'PO' Sevmash', Severodvinsk, Russia. The MOM system was made operational at Sevmash in September, 2008. This paper will discuss the objectives of the MOM system installed at Sevmash and indicate how the objectives influenced the development of the conceptual design. The paper will also describe activities related to installation of the infrastructure and the MOM system at Sevmash. Experience gained from operation of the system and how the objectives are being met will also be discussed. The paper will describe how the MOM system is used at Sevmash and, in particular, how the data is analyzed. Finally, future activities including potential expansion of the MOM system, operator training, data sharing and analysis, procedure development, repair and maintenance will be included in the paper.
The Material Protection, Control and Accounting (MPC&A) Program has been working since 1994 with nuclear sites in Russia to upgrade the physical protection (PP) and material control and accounting (MC&A) functions at facilities containing weapons usable nuclear material. In early 2001, the MPC&A program initiated the MPC&A Operations Monitoring (MOM) Project to monitor facilities where MPC&A upgrades have been installed to provide increased confidence that personnel are present and vigilant, provide confidence that security procedures are being properly performed and provide additional assurance that nuclear materials have not been stolen. The MOM project began as a pilot project at the Moscow State Engineering Physics Institute (MEPhI) and a MOM system was successfully installed in October 2001. Following the success of the MEPhI pilot project, the MPC&A Program expanded the installation of MOM systems to several other Russian facilities, including the Nuclear Physics Institute (NPI) in Tomsk. The MOM system was made operational at NPI in October 2004. This paper is focused on the experience gained from operation of this system and the objectives of the MOM system. The paper also describes how the MOM system is used at NPI and, in particular, how the data is analyzed. Finally, potential expansion of the MOM system at NPI is described.
Explore the source record for details and available documents.
This report provides the documentation for the revised procedure to generate the MC 2 -3 gamma library with the latest versions of PreGAMMA and GenGAMMA which have recently been updated to fix the program errors and inconsistent data processing for some isotopes identified in a recent verification and validation study of the MC 2 -3 gamma library. A few associated errors associated with gamma processing were also identified and fixed in the MC 2 -3 code. Addressing the changes in MC 2 -3, the procedure to generate the PMATRX and GAMISO datasets is discussed as well. The input data of PreGAMMA and GenGAMMA are discussed in detail using sample input data. In addition, the structure and formats of the MC 2 -3 gamma library are provided in detail.
Purpose: Motion artifacts are common in patient 4DCT, leading to an illdefined tumor volume with variation up to 110% or setting up a poor foundation with low imaging fidelity for tumor motion study. We developed a method to estimate 4DCT image quality by establishing a correlation between the severity of motion artifacts in 4DCT images and the periodicity of corresponding 1D respiratory wave-function (1DRW) surrogate used for 4DCT reconstruction. Methods: Fast Fourier Transformation (FFT) was applied to analyze 1DRW periodicity, defined as the sum of the 5 largest Fourier coefficients, ranging in 0–1. Distortional motion artifacts of cine-scan 4DCT at the junctions of adjacent couchposition scans around the diaphragm were identified in 3 categories: incomplete, overlapping and duplicate. To quantify these artifacts, the discontinuity of the diaphragm at the junctions was measured in distance and averaged along 6 directions in 3 orthogonal views. Mean and sum artifacts per junction (APJ) across the entire diaphragm were calculated in each breathing phase. To make the APJ inter-patient comparable, patientspecific motion was removed from APJ by dividing patient-specific diaphragmatic velocity (displacement divided by the mean period, from FFT analysis of the 1DRW) and the normalized APJ was defined as motion artifact severity (MAS). Twenty-five patients with free-breathing 10-phase 4DCT and corresponding 1DRW surrogate datasets were studied. Results: A mild correlation of 0.56 was found between 1DRW periodicity and 4DCT artifact severity. Higher MAS tends to appear around mid inhalation and mid exhalation and the lowest MAS tends to be around full exhalation. The breathing periodicity of >0.8 possesses minimal motion artifacts. Conclusion: The 1D-4D correlation provides a fast means to estimate 4DCT image quality. Using 1DRW signal, we can retrospectively screen out high-quality 4DCT images for clinical research (periodicity>0.8) and prospectively identify poor breathers as candidates of breath coaching prior to 4DCT scan. This research is in part supported by NIH (U54CA137788/132378). MC would like to thank MSKCC summer medical student research program supported by National Cancer Institute and hosted by Department of Medical Physics at MSKCC.
Purpose: New advances in radiation therapy are most likely to come from the complex interface of physics, chemistry and biology. Computational simulations offer a powerful tool for quantitatively investigating radiation interactions with biological tissue and can thus help bridge the gap between physics and biology. The aim of TOPAS-nBio is to provide a comprehensive tool to generate advanced radiobiology simulations. Methods: TOPAS wraps and extends the Geant4 Monte Carlo (MC) simulation toolkit. TOPAS-nBio is an extension to TOPAS which utilizes the physics processes in Geant4-DNA to model biological damage from very low energy secondary electrons. Specialized cell, organelle and molecular geometries were designed for the toolkit. Results: TOPAS-nBio gives the user the capability of simulating biological geometries, ranging from the micron-scale (e.g. cells and organelles) to complex nano-scale geometries (e.g. DNA and proteins). The user interacts with TOPAS-nBio through easy-to-use input parameter files. For example, in a simple cell simulation the user can specify the cell type and size as well as the type, number and size of included organelles. For more detailed nuclear simulations, the user can specify chromosome territories containing chromatin fiber loops, the later comprised of nucleosomes on a double helix. The chromatin fibers can be arranged in simple rigid geometries or within factual globules, mimicking realistic chromosome territories. TOPAS-nBio also provides users with the capability of reading protein data bank 3D structural files to simulate radiation damage to proteins or nucleic acids e.g. histones or RNA. TOPAS-nBio has been validated by comparing results to other track structure simulation software and published experimental measurements. Conclusion: TOPAS-nBio provides users with a comprehensive MC simulation tool for radiobiological simulations, giving users without advanced programming skills the ability to design and run complex simulations.
Test rig and computer program for hydrodynamic journal bearing for spacecraft power supply
Microbiological techniques for recovering trapped microorganisms from solids for use in spacecraft sterilization program