Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEASURING METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Near-infrared noise in intense electron bunches

This article investigates electron bunch density fluctuations in the 1 −10 μ⁢m wavelength range, focusing on their impact on coherent electron cooling (CEC) in hadron storage rings. In this study, we compare the shot-noise model with experimental observations using bandwidth-filtered near-infrared optical transition radiation (OTR) photodiode signals, where the transverse bunch size is much larger than the OTR wavelength of interest. The relativistic electron bunch (𝛾 ≈ 50) parameters are close to those proposed for the coherent electron cooler in the electron-ion collider (EIC) project. Preliminary feasibility experiments were conducted, and the noise factors are presented, supported by particle tracking. No major density fluctuations or effective cooling rate decrease were revealed for EIC CEC design parameters. Additionally, longitudinal-space-charge-induced microbunching for the chicane-compressed bunch was observed with coherent OTR enhancements up to 100 times, providing further calibration of the measurement method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Update on the High Precision Titration Method for Uranium Assay Supported by NBL Program Office

The NBL Program Office (NBL PO) has coordinated with Oak Ridge National Laboratory (ORNL) to implement the High Precision Titration (HPT) method for uranium assay measurements. The measurement method has been successfully developed and qualified, therefore ORNL has progressed to performing analyzes critical to the mission of the NBL PO. The HPT method is vital to producing the next generation of certified reference materials for uranium assay and isotopic abundance. The work described here focused on establishing traceability of the method to the NIST SRM 136 potassium dichromate series, and focused on investigating small differences between SRM 136e and 136f. The NBL PO evaluated the history of all of its primary uranium reference materials, including CRM 112A natural uranium metal, and worked with NIST in investigating the small differences in the dichromate SRM’s. ORNL performed comparative experiments on SRM 136e and 136f using CRM 112A. The results of the experiment will be presented here, along with NBL PO’s plans to re-evaluate the CRM 112A certified uncertainty to comply with JCGM 100, “Guide to the expression of uncertainty in measurement.”

Rogers, Kayron↗

Measurement and Simulation of the Magnetic Fields from a 555 Timer Integrated Circuit Using a Quantum Diamond Microscope and Finite-Element Analysis

Quantum diamond microscope (QDM) magnetic field imaging is an emerging interrogation and diagnostic technique for integrated circuits (ICs). To date, the ICs measured with a QDM have been either too complex for us to predict the expected magnetic fields and benchmark the QDM performance or too simple to be relevant to the IC community. In this paper, we establish a 555 timer IC as a “model system” to optimize QDM measurement implementation, benchmark performance, and assess IC device functionality. To validate the magnetic field images taken with a QDM, we use a spice electronic circuit simulator and finite-element analysis (FEA) to model the magnetic fields from the 555 die for two functional states. Furthermore, we compare the advantages and the results of three IC-diamond measurement methods, confirm that the measured and simulated magnetic images are consistent, identify the magnetic signatures of current paths within the device, and discuss using this model system to advance QDM magnetic imaging as an IC diagnostic tool.

74 ATOMIC AND MOLECULAR PHYSICS↗

A colorimetric method to measure in vitro nitrogenase functionality for engineering nitrogen fixation

Biological nitrogen fixation (BNF) is the reduction of N 2 into NH 3 in a group of prokaryotes by an extremely O 2 -sensitive protein complex called nitrogenase. Transfer of the BNF pathway directly into plants, rather than by association with microorganisms, could generate crops that are less dependent on synthetic nitrogen fertilizers and increase agricultural productivity and sustainability. In the laboratory, nitrogenase activity is commonly determined by measuring ethylene produced from the nitrogenase-dependent reduction of acetylene (ARA) using a gas chromatograph. The ARA is not well suited for analysis of large sample sets nor easily adapted to automated robotic determination of nitrogenase activities. Here, we show that a reduced sulfonated viologen derivative (S 2 V red ) assay can replace the ARA for simultaneous analysis of isolated nitrogenase proteins using a microplate reader. We used the S 2 V red to screen a library of NifH nitrogenase components targeted to mitochondria in yeast. Two NifH proteins presented properties of great interest for engineering of nitrogen fixation in plants, namely NifM independency, to reduce the number of genes to be transferred to the eukaryotic host; and O 2 resistance, to expand the half-life of NifH iron-sulfur cluster in a eukaryotic cell. This study established that NifH from Dehalococcoides ethenogenes did not require NifM for solubility, [Fe-S] cluster occupancy or functionality, and that NifH from Geobacter sulfurreducens was more resistant to O 2 exposure than the other NifH proteins tested. It demonstrates that nitrogenase components with specific biochemical properties such as a wider range of O 2 tolerance exist in Nature, and that their identification should be an area of focus for the engineering of nitrogen-fixing crops.

59 BASIC BIOLOGICAL SCIENCES↗

A Method for Measuring Coupled Individual and Social Vulnerability to Environmental Hazards

Although models of social vulnerability to environmental hazards are commonly developed to support policy interventions in emergencies and disasters, their utility is hindered by a lack of contextual information on individuals exposed to and affected by hazards. We develop a novel approach to model social vulnerability that couples individuals and their varying forms of protective capacity with the social fabric of the communities in which they reside. The backbone of our model is the Public-Use Microdata Sample (PUMS), a product of the U.S. Census Bureau that preserves a representative sample of completed responses to the American Community Survey (ACS). The PUMS enables us to understand the full range of individual protective capacities against a hazard in an exposed area, which we term individual vulnerability profiles (IVPs). In this case, we examine IVPs in the Coney Island-Brighton Beach section of New York City, which suffered severe impacts during Hurricane Sandy in 2012. To manage the large number of unique IVPs in Coney Island-Brighton Beach, we perform a segmentation analysis to generalize them into thematic cohort vulnerability profiles (CVPs) representing a typology of vulnerable people in Coney Island-Brighton Beach during Sandy. From synthetic populations of CVPs, we then estimate how individuals in varying housing types were coexposed to Sandy at the census tract level by classifying these areas into community social vulnerability profiles (SVPs). Our results provide a topology of social vulnerability that simultaneously links individual, community, and population-wide concerns, enabling a more holistic understanding of resources and interventions beneficial to human security during events like Sandy than is attainable with area-level metrics.

54 ENVIRONMENTAL SCIENCES↗

Development of Analytical Method for Measuring U and Pu Particles by Laser Ablation MC-ICP-MS for the NWAL

This project will develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The proposed work will involve: i) setup and optimization of the LA-MC-ICP-MS system, ii) testing and validation by analysis of QC standards, iii) designing analytical protocols for single particles, and iv) developing a data processing system. Ultimately, this project will output a detailed operating procedure documenting the experimental techniques and data processing routines required to perform particle identification and analysis by laser ablation MC-ICP-MS.

07 ISOTOPE AND RADIATION SOURCES↗

Apparatus and method for measuring level

A vessel with a cavity for measuring level is disclosed. The vessel includes a differential pressure sensor having a first port and a second port, a reference tube that connects the first port of the differential pressure sensor to a bottom portion of the cavity, and an impulse tube that connects the second port of the differential pressure sensor to an impulse tube ending. At least a portion of the impulse tube extends through the cavity and ends at a fluid inlet. The fluid inlet is located at a level above the reference tube.

42 ENGINEERING↗

Apparatus and method to measure semiconductor optical absorption using microwave charge sensing

A time-resolved microwave reflectance apparatus comprises a pulsed or modulated optical source that irradiates a semiconductor sample with an excitation pump beam, a microwave oscillator that irradiates the sample with a continuous beam of microwaves, and a microwave detector that detects the microwaves reflected by the sample. Therefore, charge detection, rather than conventional absorption measurements (that detect the loss of photons), can be used to extract the absorption coefficient and band edge of a semiconductor material.

Shaner, Eric A.↗

System and method for measuring sun-induced chlorophyll fluorescence

A chlorophyll fluorescence measuring system having at least one spectrometer coupled to a data logger. The data logger provides direct control of the spectrometer and includes on-board memory for storage of target and reference spectrum data obtained by the spectrometer. The data logger may be coupled to an external computer that receives and analyzes target and reference spectrum data to determine SIF using a spectral fitting algorithm. The system may include a spectrometer aiming system coupled to and controlled by the data logger. The system may also include one or more environmental sensors configured to measure environment variables. The environmental sensors may be coupled to the data logger for control and data storage. The environmental data may be communicated to the external computer for use in the spectral fitting algorithm. The data logger may be connected to a network for remote monitoring and control.

Gu, Lianhong↗

A Microwave Photonics Optical Fiber Method for Measuring Distributed Strain for Hydrologic Applications in the Vadose and Saturated Zones

Distributed strain measurements appear to hold significant potential for monitoring hydrologic processes. Coherence-length-gated Microwave Photonics Interferometry (CMPI) is a distributed sensing technique that measures strain in an optical fiber by reading optical interference phase changes in the microwave domain. The technique provides 10nε resolution when cm spatial resolution is applied. CMPI was used to measure the strain caused by small periodic variations in air pressure (25 Pa amplitude and 4 Hz) in a sand-filled laboratory column used to represent barometric loading in the vadose zone. The strain varied as a periodic function with an amplitude that decreased and a phase that increased with depth. The distribution of amplitude and phase of the strain depended on the water saturation, permeability, and presence of a barrier at the top of the sand. A theoretical analysis suggests that the air pressure diffusivity estimated from pressure data is similar to the diffusivity estimated from the distributed strain. These results indicated that the CMPI distributed strain measurement system could be used to improve monitoring and characterization of the vadose and underlying saturated zone.

Hua, Liwei↗

Development and demonstration of a rolling ball viscometer for molten salts with near-minimum liquidus NaCl–KCl

The thermophysical characterization of molten chloride and fluoride salts is a key interest for the development of advanced molten salt nuclear reactors. Viscosity is one thermophysical property of interest; a high-accuracy understanding of this property is necessary for modeling the thermal energy transfer and mass flow rate for a given molten salt system. Only a few methods have consistently been used to measure the viscosity of molten chloride and fluoride salt systems, and large discrepancies have been observed in the literature between independent studies of nearly identical salt systems. As such, exploration of novel measurement methods or implementations may allow for further validation, improved measurement accuracy, and overall improved understanding about optimal approaches for measuring molten salt viscosity. Here, in this study, a novel implementation of the rolling ball viscometry method was used to measure the viscosity of a 44/56 mol % mixture of NaCl–KCl within a temperature range of 714–838 °C, with the intent to demonstrate the feasibility of this technique for molten salt viscosity measurement cross-validation. The purity of this salt was confirmed through laser-induced breakdown spectroscopy. Measured viscosities were approximately 1.3–1.0 cP within this temperature range, and the overall uncertainty was 10.8%, which was determined through Gaussian error propagation. The results agree reasonably well with measured viscosities of similar NaCl–KCl mixtures in the literature (within 2%–20% depending on the temperature and study), although the experimental error in some of these comparative studies may be significant.

47 OTHER INSTRUMENTATION↗

Quantum utility-scale error mitigation for quantum quench dynamics in Heisenberg spin chains

Here, we implement a quantum error mitigation method termed self-mitigation, which is comparable to zero-noise extrapolation, at large scales to achieve quantum utility on near-term, noisy quantum computers. We investigate the effectiveness of several quantum error mitigation strategies, including self-mitigation, by simulating quantum quench dynamics for Heisenberg spin chains with system sizes up to 104 qubits using IBM quantum processors. In particular, we discuss the limitations of zero-noise extrapolation and the advantages offered by self-mitigation at large scales. The self-mitigation method demonstrates stable accuracy with large systems of 104 qubits comprising more than 3,000 CNOT gates. Also, we combine the discussed quantum error mitigation methods with practical entanglement entropy measuring methods, and it shows a good agreement with the theoretical estimation. Our study illustrates the usefulness of near-term noisy quantum hardware in examining the quantum quench dynamics of many-body systems at large scales and lays the groundwork for surpassing classical simulations with quantum methods prior to the development of fault-tolerant quantum computers.

97 MATHEMATICS AND COMPUTING↗