Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEDICAL ELECTRONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Megavolt bremsstrahlung measurements from linear induction accelerators demonstrate possible use as a FLASH radiotherapy source to reduce acute toxicity

Abstract Recent studies indicate better efficacy and healthy tissue sparing with high dose-rate FLASH radiotherapy (FLASH-RT) cancer treatment. This technique delivers a prompt high radiation dose rather than fractional doses over time. While some suggest thresholds of > 40 Gy s −1 with a maximal effect at > 100 Gy s −1 , accumulated evidence shows that instantaneous dose-rate and irradiation time are critical. Mechanisms are still debated, but toxicity is minimized while inducing apoptosis in malignant tissue. Delivery technologies to date show that a capability gap exists with clinic scale, broad area, deep penetrating, high dose rate systems. Based on these trends, if FLASH-RT is adopted, it may become a dominant approach except in the least technologically advanced countries. The linear induction accelerator (LIA) developed for high instantaneous and high average dose-rate, species independent charged particle acceleration, has yet to be considered for this application. We review the status of LIA technology, explore the physics of bremsstrahlung-converter-target interactions and our work on stabilizing the electron beam. While the gradient of the LIA is low, we present our preliminary work to improve the gradient by an order of magnitude, presenting a point design for a multibeam FLASH-RT system using a single accelerator for application to conformal FLASH-RT.

42 ENGINEERING↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEM Grid Testing at NLCTA in BeamNetUS Program

We report on the performance of a secondary electron monitor (SEM) grid used to measure the transverse profile of an MeV range electron beam at SLAC National Accelerator Laboratory’s Next Linear Collider Test Accelerator (NLCTA) facility. When inserted into the path of the electron beam, secondary electron emission results in a measurable current on the wires that make up the grid. We present measurements using this technique to reconstruct the beam profile. The SEM grid was designed and manufactured by a team of undergraduate students at Harvey Mudd College (HMC) and was tested at SLAC’s NLCTA facility in collaboration with NCLTA staff as part of the BeamNetUS program. Developed for real-time diagnostics of MeV-range electron beams, this SEM grid has potential applications in both industrial and medical contexts.

43 PARTICLE ACCELERATORS↗

Electron scattering processes: fundamentals, challenges, advances, and opportunities

Much effort has been devoted to describing qualitatively and quantitatively electron scattering processes due to their ever-increasing importance in many industrial and medical applications. We present achievements made in the last years, focusing on some of the advancements and recent progress in the field. Particular reference is made on concrete case studies to probe the level of accord in cross-section data obtained from experiments and theory, as well as on selected instrumentation developments to probe dynamics of dissociative processes induced by electron impact. We stress that the purpose of this colloquium paper is not to be a comprehensive review but rather to provide a snapshot of different research topics in electron scattering by pointing out certain challenges and, therefore, indicating opportunities to facilitate further experimental and theoretical work.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ion Channel Laser Based on Direct Laser Acceleration of a Shaped Beam Driver (Final Technical Report)

The main focus of our research was to understand the synergies between an electron bunch and a laser pulse when the two co-propagate through the plasma. We have clearly demonstrated using theoretical and computational modeling that the propagation distance of both the bunch and the laser pulse could be extended. The ability of the combined bunch/pulse system to extend the propagation distance and the size of the plasma bubble enables highly-efficient sources of relativistic electrons. As pointed out by the Plasma Decadal Study, such electron sources can be used for generating extremely bright x-rays for a variety of applications can serve as probes and diagnostics for other plasma experiments: high energy density (HED) sciences, inertial confinement fusion (ICF), and potentially Fusion Materials and Technology (FM&T). Development of advanced diagnostics of plasma-based accelerators is yet another key area identified by recent reports. Even broader security and medical applications of compact accelerator-based radiation sources, such as very high energy electron (VHEE) sources for FLASH radiobiology, have been identified by a recent multi-agency panel. A number of key technical issues were considered and successfully resolved during the course of the grant. Those include: beam loading effect of both the driver and witness bunches on the wake, laser channeling by the bunch, and the direct laser acceleration (DLA) of the driver bunch by the laser pulse. To demonstrate clear synergy, we were able to ascertain that the total energy gain of a witness bunch in the wake of the combined bunch/laser complex is large than the sum of the energy gains in the wake of the laser pulse alone, and the driver bunch alone. We have also demonstrated that not only the energy gain is improved, but the energy spread is not sacrificed. To carry out these simulations, we have to develop a range of in-house computational tools, including a fully-3D code WAND-PIC.

43 PARTICLE ACCELERATORS↗

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Abstract Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

60 APPLIED LIFE SCIENCES↗

Replacement of Cobalt in Medical Device Sterilization: Current Trends, Opportunities and Barriers to Adoption of X-ray and E-Beam Within the Medical Device Sterilization Market

Radioactive sources, specifically Co-60, are crucially important to the medical device sterilization industry; however, their benefits must be balanced against the need to ensure that the materials are secure. Accelerator-based sterilization methods, including X-ray and E-Beam, can in many cases sufficiently replace Co-60 and ethylene oxide, the dominant modalities currently in use; however, a lack of hands-on experience with accelerators, regulations, and a lack of capacity have hampered faster adoption of these technologies. The market is likely to change, however, given public pressures against ethylene oxide and concerns over the cost and long-term supply chain robustness of Co-60. This may provide an opportunity for growth for accelerator capabilities. Current research at Sandia National Laboratories and Argonne National Laboratory, on behalf of the Department of Energy’s National Nuclear Security Administration Office of Radiological Security, is focused on developing an understanding of the medical device sterilization marketplace, the different modalities that are used to sterilize goods, and the drivers that affect the actors within it. Research at Pacific Northwest National Laboratory, in conjunction with the medical device sterilization industry, has focused on expanding the industry’s understanding of the capabilities of X-ray sterilization and developing data that can inform the industry’s consideration of a transition towards accelerator-based devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photonic curing of solution-deposited ZrO 2 dielectric on PEN: a path towards high-throughput processing of oxide electronics

High-throughput manufacturing of oxide electronics will enable new applications ranging from large-area displays to flexible medical devices and low-cost solar panels. However, high quality oxide films from solution-based precursors typically require 20 minutes or more of thermal annealing at high temperature (> 250 °C) for each layer, severely limiting both the throughput and substrate choice. Here, we report high speed photonic curing of ZrO 2 dielectric thin films on flexible plastic substrates. The curing and patterning processes can be achieved simultaneously by using shadow mask patterning or adjusting conditions to convert oxide only on top of underlying metal contacts, i.e. self-aligned patterning. Metal-insulator-metal capacitors using two layers of ZrO 2 films photonically cured in just 100 seconds per layer show non-dispersive capacitance-frequency behavior from 10 2 to 10 6 Hz, high areal capacitance of 200 nF/cm 2 and low dissipation factor of 0.03 at 10 5 Hz, leakage current density of ~ 10 -7 A/cm 2 at an applied field of 2 MV/cm, and a breakdown field of nearly 8 MV/cm. Using an upgraded tool, similar dielectric properties are achieved in as short as 100 milliseconds using a single pulse of light, revealing a pathway to oxide film processing beyond 30 m/min.

14 SOLAR ENERGY↗

Strong ultrafast nonlinear optical response from megaelectronvolt electrons in semiconductors

Understanding radiation–matter interactions on ultrafast timescales is essential for radiation detection technologies, particularly those requiring precise timing, such as plasma monitoring, synchrotron diagnostics and medical imaging. However, the detection of highly ionizing radiation is challenging due to the stochastic nature of the interactions, resulting in dispersed energy deposition. Here we show a nonlinear optical response in semiconductors induced by 150-fs, 4.2-MeV electrons that generate highly localized charge carriers. The induced sub-10-ps optical modulation reached up to 24.5%, accompanied by a blueshift in the absorption edge consistent with band filling and carrier densities of 10 18 cm −3 . These carrier densities are 100-fold higher than expected from the deposited energy, indicating the extreme spatial localization of carriers at inelastic collisions along the ionization trajectories, thereby leading to the observed modulation. The strong nonlinearity of the MeV-electron-induced optical response enables the precise spatiotemporal detection of ionizing radiation at room temperature using common semiconductors and laser systems.

Jeong, D. [Stanford Univ., CA (United States)] (OR↗

Insights into the physiological and genomic characterization of three bacterial isolates from a highly alkaline, terrestrial serpentinizing system

The terrestrial serpentinite-hosted ecosystem known as “The Cedars” is home to a diverse microbial community persisting under highly alkaline (pH ~ 12) and reducing (Eh < -550 mV) conditions. This extreme environment presents particular difficulties for microbial life, and efforts to isolate microorganisms from The Cedars over the past decade have remained challenging. Herein, we report the initial physiological assessment and/or full genomic characterization of three isolates: Paenibacillus sp. Cedars (‘Paeni-Cedars’), Alishewanella sp. BS5-314 (‘Ali-BS5-314’), and Anaerobacillus sp. CMMVII (‘Anaero-CMMVII’). Paeni-Cedars is a Gram-positive, rod-shaped, mesophilic facultative anaerobe that grows between pH 7–10 (minimum pH tested was 7), temperatures 20–40°C, and 0–3% NaCl concentration. The addition of 10–20 mM CaCl 2 enhanced growth, and iron reduction was observed in the following order, 2-line ferrihydrite > magnetite > serpentinite ~ chromite ~ hematite. Genome analysis identified genes for flavin-mediated iron reduction and synthesis of a bacillibactin-like, catechol-type siderophore. Ali-BS5-314 is a Gram-negative, rod-shaped, mesophilic, facultative anaerobic alkaliphile that grows between pH 10–12 and temperatures 10–40°C, with limited growth observed 1–5% NaCl. Nitrate is used as a terminal electron acceptor under anaerobic conditions, which was corroborated by genome analysis. The Ali-BS5-314 genome also includes genes for benzoate-like compound metabolism. Anaero-CMMVII remained difficult to cultivate for physiological studies; however, growth was observed between pH 9–12, with the addition of 0.01–1% yeast extract. Anaero-CMMVII is a probable oxygen-tolerant anaerobic alkaliphile with hydrogenotrophic respiration coupled with nitrate reduction, as determined by genome analysis. Based on single-copy genes, ANI, AAI and dDDH analyses, Paeni-Cedars and Ali-BS5-314 are related to other species (P. glucanolyticus and A. aestuarii, respectively), and Anaero-CMMVII represents a new species. The characterization of these three isolates demonstrate the range of ecophysiological adaptations and metabolisms present in serpentinite-hosted ecosystems, including mineral reduction, alkaliphily, and siderophore production.

59 BASIC BIOLOGICAL SCIENCES↗

Motivation and Development of a Compact Superconducting Accelerator for X-ray Medical Device Sterilization

Fermilab is developing a compact superconducting (CSRF) accelerator as a source of a high-power, high-energy electron beam to produce an x-ray beam comparable to $\geq$ 2 MCi of cobalt-60. As part of this development, we are presently assembling a 20 kW, 1.6 MeV prototype that incorporates the four enabling technologies described below. These technologies support a heat budget that is within the capacity of commercially available cryocoolers and eliminate the need for liquid cryogens. The use of superconducting technologies promises efficiencies, wall-plug to beam, of 80% or greater. A summary of the design and progress to date will be given. In addition, we will present a review of developments within the medical device sterilization industry that are motivating the development of this technology.

43 PARTICLE ACCELERATORS↗

Free-electron crystals for enhanced X-ray radiation

Abstract Bremsstrahlung—the spontaneous emission of broadband radiation from free electrons that are deflected by atomic nuclei—contributes to the majority of X-rays emitted from X-ray tubes and used in applications ranging from medical imaging to semiconductor chip inspection. Here, we show that the bremsstrahlung intensity can be enhanced significantly—by more than three orders of magnitude—through shaping the electron wavefunction to periodically overlap with atoms in crystalline materials. Furthermore, we show how to shape the bremsstrahlung X-ray emission pattern into arbitrary angular emission profiles for purposes such as unidirectionality and multi-directionality. Importantly, we find that these enhancements and shaped emission profiles cannot be attributed solely to the spatial overlap between the electron probability distribution and the atomic centers, as predicted by the paraxial and non-recoil theory for free electron light emission. Our work highlights an unprecedented regime of free electron light emission where electron waveshaping provides multi-dimensional control over practical radiation processes like bremsstrahlung. Our results pave the way towards greater versatility in table-top X-ray sources and improved fundamental understanding of quantum electron-light interactions.

47 OTHER INSTRUMENTATION↗

Sequential Inference of Hospitalization Electronic Health Records Using Probabilistic Models

In the dynamic hospital setting, decision support can be a valuable tool for improving patient outcomes. Data-driven inference of future outcomes is challenging in this dynamic setting, where long sequences such as laboratory tests and medications are updated frequently. This is due in part to heterogeneity of data types and mixed-sequence types contained in variable length sequences. In this work we design a probabilistic unsupervised model for multiple arbitrary-length sequences contained in hospitalization Electronic Health Record (EHR) data. The model uses a latent variable structure and captures complex relationships between medications, diagnoses, laboratory tests, neurological assessments, and medications. It can be trained on original data, without requiring any lossy transformations or time binning. Inference algorithms are derived that use partial data to infer properties of the complete sequences, including their length and presence of specific values. We train this model on data from subjects receiving medical care in the Kaiser Permanente Northern California integrated healthcare delivery system. The results are evaluated against held-out data for predicting the length of sequences and presence of Intensive Care Unit (ICU) in hospitalization bed sequences. Our method outperforms a baseline approach, showing that in these experiments the trained model captures information in the sequences that is informative of their future values.

97 MATHEMATICS AND COMPUTING↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal electron sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accelerating multiscale electronic stopping power predictions with time-dependent density functional theory and machine learning

Knowing the rate at which particle radiation releases energy in a material, the “stopping power,” is key to designing nuclear reactors, medical treatments, semiconductor and quantum materials, and many other technologies. While the nuclear contribution to stopping power, i.e., elastic scattering between atoms, is well understood in the literature, the route for gathering data on the electronic contribution has for decades remained costly and reliant on many simplifying assumptions, including that materials are isotropic. We establish a method that combines time-dependent density functional theory (TDDFT) and machine learning to reduce the time to assess new materials to hours on a supercomputer and provide valuable data on how atomic details influence electronic stopping. Our approach uses TDDFT to compute the electronic stopping from first principles in several directions and then machine learning to interpolate to other directions at a cost of 10 million times fewer core-hours. We demonstrate the combined approach in a study of proton irradiation in aluminum and employ it to predict how the depth of maximum energy deposition, the “Bragg Peak,” varies depending on the incident angle—a quantity otherwise inaccessible to modelers and far outside the scales of quantum mechanical simulations. The lack of any experimental information requirement makes our method applicable to most materials, and its speed makes it a prime candidate for enabling quantum-to-continuum models of radiation damage. The prospect of reusing valuable TDDFT data for training the model makes our approach appealing for applications in the age of materials data science.

36 MATERIALS SCIENCE↗

Large-scale prediction of outer-membrane multiheme cytochromes uncovers hidden diversity of electroactive bacteria and underlying pathways

Multi-heme cytochromes (MHCs), together with accessory proteins like porins and periplasmic cytochromes, enable microbes to transport electrons between the cytoplasmic membrane and extracellular substrates (e.g., minerals, electrodes, other cells). Extracellular electron transfer (EET) has been described in multiple systems; yet, the broad phylogenetic and mechanistic diversity of these pathways is less clear. One commonality in EET-capable systems is the involvement of MHCs, in the form of porin-cytochrome complexes, pili-like cytochrome polymers, and lipid-anchored extracellular cytochromes. Here, we put forth MHCscan—a software tool for identifying MHCs and identifying potential EET capability. Using MHCscan, we scanned ~60,000 bacterial and 2,000 archaeal assemblies, and identify a diversity of MHCs, many of which represent enzymes with no known function, and many found within organisms not previously known to be electroactive. In total, our scan identified ~1,400 unique enzymes, each encoding more than 10 heme-binding motifs. In our analysis, we also find evidence for modularity and flexibility in MHC-dependent EET pathways, and suggest that MHCs may be far more common than previously recognized, with many facets yet to be discovered. We present MHCscan as a lightweight and user-friendly software tool that is freely available: https://github.com/Arkadiy-Garber/MHCscan.

59 BASIC BIOLOGICAL SCIENCES↗

Design and structural basis of selective 1,4-dihydropyridine inhibitors of the calcium-activated potassium channel K Ca 3.1

The 1,4-dihydropyridines, drugs with well-established bioavailability and toxicity profiles, have proven efficacy in treating human hypertension, peripheral vascular disorders, and coronary artery disease. Every 1,4-dihydropyridine in clinical use blocks L-type voltage-gated calcium channels. We now report our development, using selective optimization of a side activity (SOSA), of a class of 1,4-dihydropyridines that selectively and potently inhibit the intermediate-conductance calcium-activated K + channel K Ca 3.1, a validated therapeutic target for diseases affecting many organ systems. One of these 1,4-dihydropyridines, DHP-103, blocked K Ca 3.1 with an IC 50 of 6 nM and exhibited exquisite selectivity over calcium channels and a panel of >100 additional molecular targets. Using high-resolution structure determination by cryogenic electron microscopy together with mutagenesis and electrophysiology, we delineated the drug binding pocket for DHP-103 within the water-filled central cavity of the K Ca 3.1 channel pore, where bound drug directly impedes ion permeation. DHP-103 inhibited gain-of-function mutant K Ca 3.1 channels that cause hereditary xerocytosis, suggesting its potential use as a therapeutic for this hemolytic anemia. In a rat model of acute ischemic stroke, the second leading cause of death worldwide, DHP-103 administered 12 h postischemic insult in proof-of-concept studies reduced infarct volume, improved balance beam performance (measure of proprioception) and decreased numbers of activated microglia in infarcted areas. K Ca 3.1-selective 1,4-dihydropyridines hold promise for the many diseases for which K Ca 3.1 has been experimentally confirmed as a therapeutic target.

Ong, Seow Theng [Lee Kong Chian School of Medicine↗

Window Cooling Studies using Pulsed Beam Heating

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 using electron accelerators. Two electron accelerators are used to irradiate a double sided target. LANL collaborates with NMR to experimentally investigate beam effects on the target which consists of two Inconel 718 windows on either side of a stack of Mo-100 disks. LANL simulates the beam heating using an induction heater.

43 PARTICLE ACCELERATORS↗