Search NASA⌕ Search

SEARCH · Search NASA

Results for “METAL CORROSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Directional Gateway to Metal Oxidation: 3D Chemical Mapping Unfolds Oxygen Diffusional Pathways in Rhodium Nanoparticles

The interaction of oxygen with a reactive metal is ubiquitous, yet the precise atomic-level mechanisms and pathways leading to the formation of a surface oxide are not well-understood. We report oxygen atom distributions inside Rh single nanoparticles using atom probe microscopy (APM) and demonstrate that mainly facets of the ?022¯? crystallographic directions act as oxygen-permeable gateways. The highly anisotropic spatial distribution of incorporated oxygen atoms is in agreement with video-field emission analyses according to which {113} facets of the ?022¯? zones act as portals for subsurface diffusion. In addition to providing a more fundamental understanding of the precursor states to metal corrosion, in particular for the case of nanosized metal particles, our studies are also relevant for heterogeneous catalysis where catalytic activity and selectivity conform to reaction-induced structural changes of metal nanoparticles.

Lambeets, Sten V M.↗

Microencapsulation of Self Healing Agents for Corrosion Control Coatings

Corrosion, the environmentally induced degradation of materials, is a very costly problem that has a major impact on the global economy. Results from a 2-year breakthrough study released in 2002 by the U.S. Federal Highway Administration (FHWA) showed that the total annual estimated direct cost associated with metallic corrosion in nearly every U.S. industry sector was a staggering $276 billion, approximately 3.1% of the nation's Gross Domestic Product (GOP). Corrosion protective coatings are widely used to protect metallic structures from the detrimental effects of corrosion but their effectiveness can be seriously compromised by mechanical damage, such as a scratch, that exposes the metallic substrate. The incorporation of a self healing mechanism into a corrosion control coating would have the potential to significantly increase its effectiveness and useful lifetime. This paper describes work performed to incorporate a number of microcapsule-based self healing systems into corrosion control coatings. The work includes the preparation and evaluation of self-healing systems based on curable epoxy, acrylate, and siloxane resins, as well as, microencapsulated systems based on passive, solvent born, healing agent delivery. The synthesis and optimization of microcapsule-based self healing systems for thin coating (less than 100 micron) will be presented.

Jolley, S. T.↗

Electrochemical and galvanic corrosion effects in thin-film photovoltaic modules

The electrochemical and galvanic corrosion properties of thin-film photovoltaic (TF-PV) modules and module subcomponents are determined and interpreted in the light of established corrosion science. Results of a detailed study of thin-film aluminum metallization corrosion are presented. Bar-graph corrosion, observed in fielded modules, has been induced experimentally and found to be electrochemical in nature. Corrosion rates and passivation techniques for TF-PV modules are discussed.

Mon, G.↗

The Corrosion Protection of Metals by Ion Vapor Deposited Aluminum

A study of the corrosion protection of substrate metals by ion vapor deposited aluminum (IVD Al) coats has been carried out. Corrosion protection by both anodized and unanodized IVD Al coats has been investigated. Base metals included in the study were 2219-T87 Al, 7075-T6 Al, Titanium-6 Al-4 Vanadium (Ti-6Al-4V), 4130 steel, D6AC steel, and 4340 steel. Results reveal that the anodized IVD Al coats provide excellent corrosion protection, but good protection is also achieved by IVD Al coats that have not been anodized.

Danford, M. D.↗

Field Testing of Self-Healing Metallic Coatings for Internal Corrosion Protection of Natural Gas Pipelines

Internal corrosion occurs in natural gas pipelines primarily due to the presence of water, carbon dioxide, and hydrogen sulfide. Internal corrosion can eventually result in leakage, cracks, and rupture of the pipeline. The objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas using cold spray coatings. The corrosion behavior of carbon steel coated with self-healing zinc chromium (ZnCr) and zinc niobium (ZnNb) cold spray coatings was investigated in a natural gas environment. For comparison purposes, hot-dip galvanized steel (HDGS) was tested under the same conditions as cold spray coatings. The field test was performed at the NW Natural gas storage facility in Mist, Oregon. The field test was conducted in a 6-inch diameter pipe transporting wet natural gas out of an underground storage well at 500 psi and 4.4 °C. The coupons were tested for 15 and 32 days under stagnant and flow conditions, respectively. Weight loss method was used to measure the corrosion rate of metallic coatings. Post-corrosion surface characterization was performed on the specimen using a scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS). Crystalline phases were determined by X-ray diffraction (XRD). The field-test results confirmed that the metallic coatings provided corrosion protection of carbon steel exposed to wet natural gas under stagnant and flow conditions. The formation of the ZnCO 3 layer on top of ZnNb and ZnCr coatings led to passivation of the coatings which helps to reduce the self-corrosion. These layers form a barrier for diffusion of corrosive species to the surface.

03 NATURAL GAS↗

Restoration Process

In the accompanying photos, a laboratory technician is restoring the once-obliterated serial number of a revolver. The four-photo sequence shows the gradual progression from total invisibility to clear readability. The technician is using a new process developed in an applications engineering project conducted by NASA's Lewis Research Center in conjunction with Chicago State University. Serial numbers and other markings are frequently eliminated from metal objects to prevent tracing ownership of guns, motor vehicles, bicycles, cameras, appliances and jewelry. To restore obliterated numbers, crime laboratory investigators most often employ a chemical etching technique. It is effective, but it may cause metal corrosion and it requires extensive preparatory grinding and polishing. The NASA-Chicago State process is advantageous because it can be applied without variation to any kind of metal, it needs no preparatory work and number recovery can be accomplished without corrosive chemicals; the liquid used is water.

Source record↗

Radiation-induced vacancy injection in heterogeneous multiphase materials

Understanding the synergy between corrosion and defect dynamics is a key consideration in the development of advanced materials for extreme environments. Here, we reveal a surprising phenomenon for the transport of point defects induced by irradiation in a heterogeneous multiphase structure of a metal and an oxide, similar to that formed under metal corrosion that takes place in most environments. Despite the confinement of the produced damage within the oxide, vacancies were injected into the unirradiated metal and coarsened with dose. Furthermore, the results show that the nature of the oxide layer dictates the defect evolution in the metal layer. This work reveals an interesting mechanism for point defect interactions in multiphase materials, with broad implications in many fields, while also emphasizing the complex coupling between corrosion and irradiation. Corrosion leads to the formation of multiphase materials, while irradiation enhances diffusion within the heterogeneous phases, which can impact corrosion rates.

36 MATERIALS SCIENCE↗

Method for identification of redox control parameters for corrosion mitigation in molten fluoride salts

Structural material corrosion is a significant concern for the development of molten salt-cooled reactors (MSR) and redox control was proposed to mitigate the corrosion. This study presents an efficient approach to identify the partial pressure of F 2 gas for fluorine driven corrosion, the concentration ratios of UF 4 /UF 3 and ZrF 4 /ZrF 2 , and the partial pressure ratio of HF/H 2 needed to limit metal corrosion and its subsequent dissolution in molten fluoride salts. The identification procedure is made by simply using auxiliary axes in Ellingham diagrams. This approach greatly simplifies the optimization of redox control methods in studying the material corrosion in molten salts.

36 MATERIALS SCIENCE↗

Suppressing Chemical Corrosions of Lithium Metal Anodes

In this study, the lithium metal anode is essential for next-generation high-energy-density rechargeable Li-metal batteries. Although extensive studies have been performed to prolong the cycle life of Li-metal batteries, the calendar life, which associates with the chemical corrosion of Li metal in liquid electrolytes, has not been quantitatively understood. Here, by combing the titration gas chromatography method and cryogenic focused ion beam, a quantitative relationship between the chemical corrosion rate and electrochemically deposited Li morphology in various liquid electrolyte systems is established. It has been identified that the corrosion rate is dominated by the porosity of the deposited Li. The larger the porosity of deposited Li has, the faster the corrosion rate will be. Strategies to mitigate the chemical corrosion on Li thus to extend the calendar life of Li-metal batteries are further proposed. By strictly controlling the stacking pressure during Li plating, Li deposits with ultra-low porosity can be achieved, suppressing the corrosion rate to 0.08 ± 0.16%/day compared with 1.71 ± 0.19%/day of the high-porosity Li.

25 ENERGY STORAGE↗

Stress-corrosion cracking in metals

Criteria and recommended practices for preventing stress-corrosion cracking from impairing the structural integrity and flightworthiness of space vehicles are presented. The important variables affecting stress-corrosion cracking are considered to be the environment, including time and temperature; metal composition, and structure; and sustained tensile stress. For designing spacecraft structures that are free of stress-corrosion cracking for the service life of the vehicle the following rules apply: (1) identification and control of the environments to which the structure will be exposed during construction, storage, transportation, and use; (2) selection of alloy compositions and tempers which are resistant to stress-corrosion cracking in the identified environment; (3) control of fabrication and other processes which may introduce residual tensile stresses or damage the material; (4) limitation of the combined residual and applied tensile stresses to below the threshold stress level for the onset of cracking throughout the service life of the vehicle; and (5) establishment of a thorough inspection program.

Source record↗

Tests of NASA ceramic thermal barrier coating for gas-turbine engines

A NASA ceramic thermal barrier coating (TBC) system was tested by industrial and governmental organizations for a variety of aeronautical marine, and ground-based gas-turbine engine applications. This TBC is a two-layer system with a bond coating of nickel-chromium-aluminum-yttrium (Ni-16Cr-6Al-0.6Y, in wt %) and a ceramic coating of yttria stabilized zirconia (ZrO2-12Y2O3, in wt %). Tests (Liebert and Stenka, 1979) have been conducted to determine corrosion resistance, thermal protection, durability, thermal conductivity, and fatigue characteristics. The information presented covers some of the significant test results obtained on the first three items. The information also includes photographs of coated parts after tests, measurements of coating loss, amount of metal wall temperature reduction when the TBC is used, and extent of base metal corrosion.

Liebert, C. H.↗

Analysis of Microbial Communities as Indicators of Microbially Induced Corrosion Potential in Stainless Steel Piping

The 200 West Area Pump-and-Treat (200W P&T) facility is part of the final remedy decision for the 200 ZP-1 Operable Unit (OU) and is the interim remedial action for 200-UP-1 OU at the Hanford Site. The facility also treats water from other sources across the site, including 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. The facility originally operated a biological treatment process for nitrate that resulted in systemic biofouling and loss of injection well capacity, requiring frequent and costly well rehabilitation. Biofouling has also contributed to corrosion of welds and pitting of stainless-steel piping at the facility. The biological treatment for nitrate was suspended at the end of 2019 calendar year to eliminate negative impacts from biological treatments which improve facility operations and treatment of carbon tetrachloride. Evaluation of the 200W P&T facility’s response to operational improvements, specifically the suspension of the biological treatment, provides information on the potential for continued microbially induced corrosion (MIC). To this end, historical data sets (2015-2017) were compared with molecular biological analyses of 200W P&T water samples from 2018-2020 to quantify trends in total microbial biomass and specific microbial indicator species (iron, sulfate, nitrate, and manganese reducing bacteria) known to cause and enhance metal corrosion. Results showed unequivocal reductions (in excess of 90%) in all microbiological indicators measured following the suspension of the biological treatment. Although abundance measurements for all corrosive MIC populations initially declined after removal of the treatment system, nitrate-reducing bacteria (nirK) and sulfate-reducing bacteria remain highly abundant in the system, an order of magnitude higher than the number of cells present prior to the removal of the biological treatment system [5.14e (1.4) cells/L, vs. 1.14e (0.07) cells/L, reported as average (±SD) for n=3]. In addition, there was an unexpected inflection point in 2019 where all microbial indicators increased unexpectedly in abundance in 2020 by as much as two orders of magnitude compared to 2019 samples. Given the limited number of water samples available for this analysis, the cause of the increase in microbial indicators post-biological treatment has not yet been determined. Systematic sampling of the facility for continued monitoring is recommended so that the responses of MIC populations can be evaluated to ensure that further corrosion is avoided, allowing the 200W P&T facility to operate safely and efficiently at design capacity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stable, high-performance, dendrite-free, seawater-based aqueous batteries

Metal anode instability, including dendrite growth, metal corrosion, and hetero-ions interference, occurring at the electrolyte/electrode interface of aqueous batteries, are among the most critical issues hindering their widespread use in energy storage. Herein, a universal strategy is proposed to overcome the anode instability issues by rationally designing alloyed materials, using Zn-M alloys as model systems (M = Mn and other transition metals). An in-situ optical visualization coupled with finite element analysis is utilized to mimic actual electrochemical environments analogous to the actual aqueous batteries and analyze the complex electrochemical behaviors. The Zn-Mn alloy anodes achieved stability over thousands of cycles even under harsh electrochemical conditions, including testing in seawater-based aqueous electrolytes and using a high current density of 80 mA cm –2 . The proposed design strategy and the in-situ visualization protocol for the observation of dendrite growth set up a new milestone in developing durable electrodes for aqueous batteries and beyond.

25 ENERGY STORAGE↗

An Impedance-Loaded Surface Acoustic Wave Corrosion Sensor for Infrastructure Monitoring

Passive surface acoustic wave (SAW) devices are attractive candidates for continuous wireless monitoring of corrosion in large infrastructures. However, acoustic loss in the aqueous medium and limited read range usually create challenges in their widespread use for monitoring large systems such as oil and gas (O&G) pipelines, aircraft, and processing plants. This paper presents the investigation of impedance-loaded reflective delay line (IL-RDL) SAW devices for monitoring metal corrosion under O&G pipeline-relevant conditions. Specifically, we studied the effect of change in resistivity of a reflector on the backscattered signal of an RDL and investigated an optimal range through simulation. This was followed by the experimental demonstrations of real-time monitoring of Fe film corrosion in pressurized (550 psi) humid CO 2 conditions. Additionally, remote monitoring of Fe film corrosion in an acidic solution inside a 70 m carbon steel pipe was demonstrated using guided waves. This paper also suggests potential ways to improve the sensing response of IL-RDLs.

47 OTHER INSTRUMENTATION↗

Property Measurements of LiF-NaF-KF Molten Salts Doped with Corrosion Products and Oxygen

Measurements of thermophysical properties of molten salts are needed for modeling and simulation activities that support the development of molten salt reactor (MSR) technologies. Properties of interest including transition temperatures, phase behavior, heat capacity, density, volumetric thermal expansion, surface tension, viscosity, thermal diffusivity, thermal conductivity, and vapor pressure are being performed at Argonne. Results of these property measurements are suitable for use in evaluating reactor performance during startup and the early operating life of the reactor. Ingressions of oxygen and moisture into the fuel salt are expected to occur at different times during the operating life of the reactor due to system leaks, maintenance, and refueling activities. The presence of these environmental contaminants induces corrosion of structural materials. The introduction of corrosion-derived species, oxygen and moisture is expected to affect the physical and chemical properties of the salt and operation of the reactor. Previous work performed at Argonne evaluated the effects of fission product dopants on the thermal properties of eutectic LiF-NaF-KF (FLiNaK). Properties of FLiNaK are commonly used to represent those of fluoride-bearing fuel salts. Metallic corrosion products such as chromium and nickel ions together with dissolved oxygen are expected to affect system redox differently than the accumulation of fission products. Work summarized in this report was performed to measure the effects of corrosion products and dissolved oxygen on the phase transitions, and specific heat capacity of FLiNaK. Thermophysical property measurements were made using four salts that were prepared by doping aliquots of a eutectic mixture of FLiNaK with surrogate corrosion products. Controlled additions of CrF 3 and NiF 2 were used as surrogates for corrosion product contamination anticipated during extended reactor operations in which fuel salt is in contact with steel reactor components. Controlled additions of UF 4 from two sources containing known amounts of UO 2 at different concentrations were used to represent oxygen contamination. The phase transitions and specific heat capacities of the four salts were measured by using differential scanning calorimetry. Measurements were made at temperatures spanning the range of 500−900 °C, which is the expected operating range of MSRs. Measured property values were compared to values measured previously with eutectic FLiNaK without dopants. Differences between property values measured for the doped and non-doped salts were compared with the uncertainties of the measurements to determine the significance of the effect of corrosion products and oxygen on salt properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phase Transfer‐Mediated Degradation of Ether‐Based Localized High‐Concentration Electrolytes in Alkali Metal Batteries

Abstract Localized high‐concentration electrolytes (LHCEs) have attracted interest in alkali metal batteries due to the advantages of forming stable solid‐electrolyte interphases (SEIs) on anodes and good chemical/electrochemical stability. Herein, a new degradation mechanism is revealed for ether‐based LHCEs that questions their compatibility with alkali metal anodes (Li, Na, and K). Specifically, the ether solvent reacts with alkali metals to generate solvated electrons (e s − ) that attack hydrofluoroether co‐solvents to form a series of byproducts. The ether solvent essentially acts as a phase‐transfer reagent that continuously transfers electrons from solid‐phase metals into the solution phase, thus inhibiting the formation of stable SEI and leading to continuous alkali metal corrosion. Switching to an ester‐based solvating solvent or intercalation anodes such as graphite or molybdenum disulfide has been shown to avoid such a degradation mechanism due to the absence of e s − .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗