Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICHELSON INTERFEROMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Optical diameters of stars measured with the Mt. Wilson Mark III interferometer

Reliable stellar angular diameters can now be determined using the Mark III Optical Interferometer located on Mt. Wilson, California. The Mark III is a Michelson Interferometer capable of measuring the interferometric fringe visibility for stars using interferometer baselines varying from 3 to 31.5 meters in length. Angular diameters measured with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm.

Simon, R. S.↗

Orbiting stellar interferometer for astrometry and imaging

The orbiting stellar interferometer (OSI) is a concept for a first-generation space interferometer with astrometric and imaging goals. The OSI is a triple Michelson interferometer with articulating siderostats and optical delay lines. Two point designs for the instrument are described. The 18-m design uses an 18-m maximum baseline and aperture diameters of 40 cm; the targeted astrometric performance is a wide-field accuracy of 10 microarsec for 16-mag objects in 100 s of integration time and for 20-mag objects in 1 h. The instrument would also be capable of synthesis imaging with a resolution of 5 marcsec, which corresponds to the diffraction limit of the 18-m base line. The design uses a deployed structure, which would fold to fit into an Atlas IIAS shroud, for insertion into a 900-km sun-synchronous orbit. In addition to the 18-m point design, a 7-m point design that uses a shorter base line in order to simplify deployment is also discussed. OSI's high performance is made possible by utilizing laser metrology and controlled-optics technology.

Colavita, M. M.↗

Alignment of a two-beam interferometer

Two beam interferometers have been proposed for space applications such as sensing the shape of a large antenna. Since alignment and adjustment of interferometers have long been considered difficult laboratory tasks, the question of making their operation sufficiently automatic for space applications is a serious one. As a first step in addressing this question certain manual procedures, which may not be well known, have been collected from widely scattered sources. These techniques are illustrated by two examples: (1) the alignment of a Mach-Zehnder interferometer and the adjustment of fringe location. (2) The adjustment of a Michelson interferometer for zero path difference (white light fringes).

Tubbs, E. F.↗

Study of the Imaging Capabilities of SPIRIT/SPECS Concept Interferometers

Several new space science mission concepts under development at NASA-GSFC for astronomy are intended to carry out synthetic imaging using Michelson interferometers or direct (Fizeau) imaging with sparse apertures. Examples of these mission concepts include the Stellar Imager (SI), the Space Infrared Interferometric Telescope (SPIRIT), the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS), and the Fourier-Kelvin Stellar Interferometer (FKSI). We have been developing computer-based simulators for these missions. These simulators are aimed at providing a quantitative evaluation of the imaging capabilities of the mission by modeling the performance on different realistic targets in terms of sensitivity, angular resolution, and dynamic range. Both Fizeau and Michelson modes of operation can be considered. Our work is based on adapting a computer simulator called imSIM which was initially written for the Space Interferometer Mission in order to simulate the imaging mode of new missions such as those listed. This report covers the activities we have undertaken to provide a preliminary version of a simulator for the SPIRIT mission concept.

Allen, Ronald J.↗

Proper time observables of general gravitational perturbations in laser interferometry-based gravitational wave detectors

We present an explicitly gauge-invariant observable of any general gravitational perturbation, ℎ 𝜇⁢𝜈 [not necessarily due to gravitational waves (GWs)], in a laser interferometry-based GW detector, identifying the signature as the proper time elapsed of the beamsplitter observer, between two events: when a photon passes through the beamsplitter, and when the same photon returns to the beamsplitter after traveling through the interferometer arm and reflecting off the far mirror. Our formalism applies to simple Michelson interferometers and can be generalized to more advanced setups. We demonstrate that the proper time observable for a plane GW is equivalent to the detector strain commonly used by the GW community, though now the common framework can be easily generalized for other types of signals, such as dark matter clumps or spacetime fluctuations from quantum gravity. We provide a simple recipe for computing the proper time observable for a general metric perturbation in linearized gravity and explicitly show that it is invariant under diffeomorphisms of the perturbation, as any physical observable should be.

Dark matter detectors↗

A Study of Imaging Interferometer Simulators

Several new space science mission concepts under development at NASA-GSFC for astronomy are intended to carry out synthetic imaging using Michelson interferometers or direct (Fizeau) imaging with sparse apertures. Examples of these mission concepts include the Stellar Imager (SI), the Space Infrared Interferometric Telescope (SPIRIT), the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS), and the Fourier-Kelvin Stellar Interferometer (FKSI). We have been developing computer-based simulators for these missions. These simulators are aimed at providing a quantitative evaluation of the imaging capabilities of the mission by modelling the performance on different realistic targets in terms of sensitivity, angular resolution, and dynamic range. Both Fizeau and Michelson modes of operation can be considered. Our work is based on adapting a computer simulator called imSIM, which was initially written for the Space Interferometer Mission in order to simulate the imaging mode of new missions such as those listed. In a recent GSFC-funded study we have successfully written a preliminary version of a simulator SISIM for the Stellar Imager and carried out some preliminary studies with it. In a separately funded study we have also been applying these methods to SPECS/SPIRIT.

Allen, Ronald J.↗

The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII)

The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. BETTII uses a double-Fourier Michelson interferometer to simultaneously obtain spatial and spectral information on science targets; the long baseline provides subarcsecond angular resolution, a capability unmatched by other far-infrared facilities. Here, we present key aspects of the overall design of the mission and provide an overview of the current status of the project. We also discuss briefly the implications of this experiment for future space-based far-infrared interferometers.

Rinehart, Stephen↗

Acoustic Amplification in the Far Infrared Focal Plane Assembly of the Composite Infrared Spectrometer (CIRS) for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared FIR and mid infrared, MIR wavelength region. The FIR is a polarizing Michelson interferometer which presents a collimated output beam to the FIR focal plane. The focal plane consists of a parabolic focus mirror and an analyzer grid, which splits the output beams into transmitted and reflected components. The two polarizations are focussed onto two thermopile detectors; each consisting of a gold black foil welded to the top of two bismuth pyramids. The gold black is 30 microns thick, and the weld area is approximately 2 microns in diameter. The detectors are extremely fragile and the weld can be broken with a miniscule amount of airflow. The detectors consistently passed acoustic testing to qualification levels that simulated the launch environment of the Titan IV launch vehicle. However, they experienced a 50% failure rate when installed in the focal plane assembly during instrument level acoustic tests. A test focal plane was developed with small pressure transducers in the nominal detector locations. These tests indicated over 10 dB of acoustic amplification in the focal plane within the instrument during testing. New techniques were developed to allow testing of the focal plane without over testing the instrument, and modifications were made the focal plane assembly to successfully attenuate the amplification.

Hagopian, John G.↗

Grid polarizers for infrared Fourier spectrometers

Infrared grid polarizers consisting of copper lines with a 3.6-micron grid constant on a 4-micron-thick Mylar polyester substrate have been prepared by the techniques of photolithography and sputter-etching. Their polarization properties have been measured and found to be suitable for use at infrared frequencies below 700/cm. The polarizers have been used to extend the useful frequency range of a Martin-Puplett polarizing interferometer designed for Fourier transform spectroscopy. The efficiency of the interferometer has been measured over a frequency range from 50 to 700/cm and compared to that of a conventional Michelson interferometer. The results are shown to be consistent with the measured properties of the polarizers. Methods are suggested for improving the efficiency of a Martin-Puplett interferometer which employs these polarizers.

Challener, W. A.↗

Reference Interferometer Using a Semiconductor Laser/LED Reference Source in a Cryogenic Fourier-Transform Spectrometer

A combination of a single mode AlGaAs laser diode and broadband LED was used in a Michelson interferometer to provide reference signals in a Fourier transform spectrometer, the Composite Infrared Spectrometer, on the Cassini mission to Saturn. The narrowband light from the laser produced continuous fringes throughout the travel of the interferometer, which were used to control the velocity of the scan mechanism and to trigger data sampling. The broadband light from the LED produced a burst of fringes at zero path difference, which was used as a fixed position reference. The system, including the sources, the interferometer, and the detectors, was designed to work both at room temperature and instrument operating temperature of 170 Kelvin. One major challenge that was overcome was preservation, from room temperature to 170 K, of alignment sufficient for high modulation of fringes from the broadband source. Another was the shift of the source spectra about 30 nm toward shorter wavelengths upon cooldown.

Martino, Anthony J.↗

Exploring the Saturn System in the Thermal Infrared: The Composite Infrared Spectrometer

The Composite Inbred Spectrometer (CIRS) is a remote-sensing Fourier Transform Spectrometer on the Cassini orbiter that measures thermal radiation over two decades in wave number, from 10 to 1400 cm (1 mm to 7pm), with a spectral resolution that can be set from 0.5 to 20 cm. The far in portion of the spectrum (10 - 600 cm) is measured with a polarizing interferometer having thermopile detectors with a common 4-mrad field of view. The middle infrared portion is measured with a traditional Michelson interferometer having two focal planes (600 - 1100cm, 1100-1400 cm). Each focal plane is composed of a 1x10 array of HgCdTe detectors, each detector having a 0.3-mrad field of view. CIRS observations will provide three-dimensional maps of temperature, gas composition, and aerosols/condensates of the atmospheres of Titan and Saturn with good vertical and horizontal resolution, from deep in their tropospheres to high in their mesospheres. CIRS ability to observe atmospheres in the limb viewing mode (in addition to nadir) offers the opportunity to provide accurate and highly resolved vertical profiles of these atmospheric variables. The ability to observe with high-spectral resolution should facilitate the identification of new constituents. CIRS will also map the thermal and compositional properties of the surfaces of Saturn's icy satellites. It will similarly map Saturn's rings, characterizing their formation and evolution. The combination of broad spectral range, programmable spectral resolution, the small detector fields of view, and an orbiting spacecraft platform will allow CIRS to observe the Saturnian system in the thermal infrared at a level of detail not previously achieved.

Flasar, F. M.↗

Early Results on the Saturn System from the Composite Infrared Spectrometer

The Composite Infrared Spectrometer (CIRS) is a remote-sensing Fourier Transform Spectrometer on the Cassini orbiter that measures thermal radiation over two decades in wavenumber, from 10 to 1400 /cm (1 mm to 7 microns), with a spectral resolution that can be set from 0.5 to 15.5 /cm. The far infrared portion of the spectrum (10-600 /cm) is measured with a polarizing interferometer having thermopile detectors with a common 4-mrad field of view. The middle infrared portion is measured with a traditional Michelson interferometer having two focal planes (600-1100 /cm, 1100-1400 cm). Each focal plane is composed of a 1x10 array of HgCdTe detectors, each detector having a 0.3-mrad field of view. More complete descriptions of the instrument and investigation are given in and. A brief description of the first results from observations through the Saturn orbital insertion period can be found in.

Flasar, F. M.↗

Fourier Transform Fabry-Perot Interferometer

We are developing a compact, rugged, high-resolution remote sensing instrument with wide spectral scanning capabilities. This relatively new type of instrument, which we have chosen to call the Fourier-Transform Fabry-Perot Interferometer (FT-FPI), is accomplished by mechanically scanning the etalon plates of a Fabry-Perot interferometer (FPI) through a large optical distance while examining the concomitant signal with a Fourier-transform analysis technique similar to that employed by the Michelson interferometer. The FT-FPI will be used initially as a ground-based instrument to study near-infrared atmospheric absorption lines of trace gases using the techniques of solar absorption spectroscopy. Future plans include modifications to allow for measurements of trace gases in the stratosphere using spectral lines at terahertz frequencies.

Snell, Hilary E.↗

Design and Status of the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII): An Interferometer at the Edge of Space

The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infraredinterferometer designed to fly on a high altitude balloon. BETTII uses a double-Fourier Michelson interferometer tosimultaneously obtain spatial and spectral information on science targets; the long baseline permits subarcsecond angular resolution, a capability unmatched by other far-infrared facilities. Here, we present key aspects of the overall design of the mission and provide an overview of the current status of the project. We also discuss briefly the implications of this experiment for future space-based far-infrared interferometers.

Balloon↗

Orbiting Stellar Interferometer: An Overview

The Orbiting Stellar Interferometer (OSI) is a concept for a first-generation space interferometer with astrometric and imaging capabilities and is responsive to the recommendations of the Astronomy and Astrophysics Survey Committee for an astrometric interferometry mission. OSI is a triple Michelson interferometer with articulating siderostats and optical delay lines. The design uses a 7m maximum baseline and aperture diameters of 33 cm; the targeted astrometric performance is a wide-field accuracy of 5µas for 20-mag objects. The instrument would also be capable of synthesis imaging with a resolution of 10mas. Laser metrology is used to relax structural requirements thereby reducing cost. The currently envisaged flight system fits into an Atlas II shroud, for insertion into a 900 km sun-synchronous orbit.

['OSI↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗

Ultraviolet-Infrared Mapping Interferometic Spectrometer

Prism and grating spectrometers have been the defacto devices for spectral mapping and imaging (hereafter referred to as hyperspectra). We have developed a new, hybrid instrument with many superior capabilities, the Digital Array Scanned Interferometer, DASI. The DASI performs the hyperspectral data acquisition in the same way as a grating or prism spectrograph, but retains the substantial advantages of the two-beam (Michelson) interferometer with additional capabilities not possessed by either of the other devices. The DASI is capable of hyperspectral studies in virtually any space or surface environment at any wavelength from below 50 nm to beyond 12 microns with available array detectors. By our efforts, we have defined simple, low cost, no-moving parts DASI's capable of carrying out hyperspectral science measurements for solar system exploration missions, e.g. for martian, asteroid, lunar, or cometary surveys. DASI capabilities can be utilized to minimize cost, weight, power, pointing, and other physical requirements while maximizing the science data return for spectral mapping missions. Our success in the development of DASI's has become and continues to be an important influence on the efforts of the best research groups developing remote sensing instruments for space and other applications.

Source record↗

GALILEO: Galactic Axion Laser Interferometer Leveraging Electro-Optics

We propose a novel experimental method for probing light dark matter candidates. We show that an electro-optical material’s refractive index is modified in the presence of a coherently oscillating dark matter background. A high-precision resonant Michelson interferometer can be used to read out this signal. The proposed detection scheme allows for the exploration of an uncharted parameter space of dark matter candidates over a wide range of masses—including masses exceeding a few tens of microelectronvolts, which is a challenging parameter space for microwave cavity haloscopes. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗