Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROWAVE APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluation of the microwave spectrum of Venus in the 1.2-22 centimeter wavelength range based on laboratory measurements of constituent gas opacities

Laboratory measurements of the microwave (1.2-22.3 cm) spectrum properties of Venus' gaseous atmospheric constituents were performed using an apparatus for simulating conditions of the middle atmosphere of Venus (gaseous H2SO4 + CO2 at 1 to 6 atm). The results have shown that at wavelengths longer than 1.8 cm, gaseous H2SO4 and CO2 are the predominant microwave absorbers, while at wavelengths from 1.2 to 1.8 cm, SO2 and CO2 are the predominant absorbers. These results were used to develop a model for the microwave emission spectrum of Venus, which correlated well with microwave observations of this planet.

Steffes, Paul G.↗

Extra-corporeal blood access, sensing, and radiation methods and apparatuses

The described invention is related to extra-corporeal blood access and radiation methods and apparatuses and, in particular, to subjecting flowing blood to energy in variety of forms, including radiation, electromagnetic force fields or atomic particles. It is directed to methods and apparatuses for accessing flowing blood and for subjecting the blood to electrical conductive, electrostatic or electromagnetic fields or for radiating the blood with some type of radiation, e.g., radio waves, ultrasonic or audio waves, microwaves, IR rays, visible light, UV radiation, x-rays, alpha, beta or gamma rays. An apparatus is employed which includes one or more access ports or windows for radiating blood and/or for sensing/analyzing blood. This invention is useful for killing viruses and bacteria in blood, monitoring blood for medical purposes, genetic modification of blood, and analyzing and/or treating blood components.

Castle, Kent D.↗

Microwave spectra of some sulfur and nitrogen compounds

A computer-controlled microwave spectrometer was used to catalog reference spectra for chemical analysis. The apparatus, software, and experimental procedures are described. Tables of absorption frequencies, peak absorption coefficients, and integrated intensities are included for 13 sulfur compounds, 14 nitrogen compounds, and 1 compound containing both sulfur and nitrogen. The frequency range covered was 26,500 to 40,000 MHz for most compounds and 18,000 to 40,000 MHz for some.

White, W. F.↗

Improved Linear-Ion-Trap Frequency Standard

Improved design concept for linear-ion-trap (LIT) frequency-standard apparatus proposed. Apparatus contains lengthened linear ion trap, and ions processed alternately in two regions: ions prepared in upper region of trap, then transported to lower region for exposure to microwave radiation, then returned to upper region for optical interrogation. Improved design intended to increase long-term frequency stability of apparatus while reducing size, mass, and cost.

Prestage, John D.↗

Microwave-Spectral Signatures Would Reveal Concealed Objects

A proposed technique for locating concealed objects (especially small antipersonnel land mines) involves the acquisition and processing of spectral signatures over broad microwave frequency bands. This technique was conceived to overcome the weaknesses of older narrow- band electromagnetic techniques like ground-probing radar and low-frequency electromagnetic induction. Ground-probing radar is susceptible to false detections and/or interference caused by rocks, roots, air pockets, soil inhomogeneities, ice, liquid water, and miscellaneous buried objects other than those sought. Moreover, if the radar frequency happens to be one for which the permittivity of a sought object matches the permittivity of the surrounding soil or there is an unfavorable complex-amplitude addition of the radar reflection at the receiver, then the object is not detected. Low-frequency electromagnetic induction works well for detecting metallic objects, but the amounts of metal in plastic mines are often too small to be detectable. The potential advantage of the proposed technique arises from the fact that wideband spectral signatures generally contain more relevant information than do narrow-band signals. Consequently, spectral signatures could be used to make better decisions regarding whether concealed objects are present and whether they are the ones sought. In some cases, spectral signatures could provide information on the depths, sizes, shapes, and compositions of objects. An apparatus to implement the proposed technique (see Figure 1) could be assembled from equipment already in common use. Typically, such an apparatus would include a radio-frequency (RF) transmitter/receiver, a broad-band microwave antenna, and a fast personal computer loaded with appropriate software. In operation, the counter would be turned on, the antenna would be aimed at the ground or other mass suspected to contain a mine or other sought object, and the operating frequency would be swept over the band of interest.

Arndt, G.↗

Method and Apparatus for Measuring Fluid Flow

Method and apparatus for making measurements on fluids related to their complex permeability are disclosed. A microwave probe is provided for exposure to the fluids. The probe can be non-intrusive or can also be positioned at the location where measurements are to be made. The impedance of the probe is determined. in part. by the complex dielectric constant of the fluids at the probe. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids. Multiple probes may be selectively positioned to monitor the behavior of the fluids including their flow rate. Fluids may be identified as between two or more different fluids as well as multiple phases of the same fluid based on differences between their complex permittivities.

Arndt, G. Dickey↗

Apparatus for production, measurement and reaction studies of dissociated gases at elevated temperatures

An apparatus is described which is used for the controlled production, characterization, and study of dissociated gases in a microwave discharge at elevated temperatures. A unique feature is the ability to produce and study a microwave discharge plasma in the heated zone. This allows elevated temperature reactions to be studied in high concentrations of dissociated gases. Further, the system permits weight change measurements of specimens in the plasma, thus facilitating reaction rate determinations. Included is a description of a cavity for use on a 50-mm diameter cylindrical reactor. The effects of flow rate, pressure, temperature, power, metal sample, and sampling position on dissociation percentage of oxygen in the apparatus are described as well as a technique for sample temperature measurements in the plasma which permits determination of high temperature recombination coefficients and reaction rates.

Christian, J. D.↗

Microwave Oscillators Based on Nonlinear WGM Resonators

Optical oscillators that exploit resonantly enhanced four-wave mixing in nonlinear whispering-gallery-mode (WGM) resonators are under investigation for potential utility as low-power, ultra-miniature sources of stable, spectrally pure microwave signals. There are numerous potential uses for such oscillators in radar systems, communication systems, and scientific instrumentation. The resonator in an oscillator of this type is made of a crystalline material that exhibits cubic Kerr nonlinearity, which supports the four-photon parametric process also known as four-wave mixing. The oscillator can be characterized as all-optical in the sense that the entire process of generation of the microwave signal takes place within the WGM resonator. The resonantly enhanced four-wave mixing yields coherent, phase-modulated optical signals at frequencies governed by the resonator structure. The frequency of the phase-modulation signal, which is in the microwave range, equals the difference between the frequencies of the optical signals; hence, this frequency is also governed by the resonator structure. Hence, further, the microwave signal is stable and can be used as a reference signal. The figure schematically depicts the apparatus used in a proof-of-principle experiment. Linearly polarized pump light was generated by an yttrium aluminum garnet laser at a wavelength of 1.32 microns. By use of a 90:10 fiber-optic splitter and optical fibers, some of the laser light was sent into a delay line and some was transmitted to one face of glass coupling prism, that, in turn, coupled the laser light into a crystalline CaF2 WGM disk resonator that had a resonance quality factor (Q) of 6x10(exp 9). The output light of the resonator was collected via another face of the coupling prism and a single-mode optical fiber, which transmitted the light to a 50:50 fiber-optic splitter. One output of this splitter was sent to a slow photodiode to obtain a DC signal for locking the laser to a particular resonator mode. The other output of this splitter was combined with the delayed laser signal in another 50:50 fiber-optic splitter used as a combiner. The output.of the combiner was fed to a fast photodiode that demodulated light and generated microwave signal. In this optical configuration, the resonator was incorporated into one arm of a Mach-Zehnder interferometer, which was necessary for the following reasons: It was found that when the output of the resonator was sent directly to a fast photodiode, the output of the photodiode did not include a measurable microwave signal. However, when the resonator was placed in an arm of the interferometer and the delay in the other arm was set at the correct value, the microwave signal appeared. Such behavior is distinctly characteristic of phase-modulated light. The phase-modulation signal had a frequency of about 8 GHz, corresponding to the free spectral range of the resonator. The spectral width of this microwave signal was less than 200 Hz. The threshold pump power for generating the microwave signal was about 1 mW. It would be possible to reduce the threshold power by several orders of magnitude if resonators could be made from crystalline materials in dimensions comparable to those of micro-resonators heretofore made from fused silica.

Maleki, Lute↗

Photoelectron spectra of the decomposition of ethylene on /110/ tungsten

The experimental apparatus used in the investigation consisted of an ultrahigh-vacuum chamber, a triple-grid, a microwave-excited resonance lamp, and an electron energy analyzer. The chemical nature of the chemisorbed species was studied, taking into account the energy distribution of photoemitted electrons, work function determinations, and low-energy electron diffraction patterns.

Plummer, E. W.↗

AIRS: Improving Weather Forecasting and Providing New Data on Greenhouse Gases

This paper discusses the performance of AIRS and examines how it is meeting its operational and research objectives based on the experience of more than 2 yr with AIRS data. We describe the science background and the performance of AIRS in terms of the accuracy and stability of its observed spectral radiances. We examine the validation of the retrieved temperature and water vapor profiles against collocated operational radiosondes, and then we assess the impact thereof on numerical weather forecasting of the assimilation of the AIRS spectra and the retrieved temperature. We close the paper with a discussion on the retrieval of several minor tropospheric constituents from AIRS spectra.

remote sensing↗

Method and apparatus for measuring solar activity and atmospheric radiation effects

A radiometric measuring system is described for observing solar activity, atmospheric attenuation, and atmospheric emission. Two highly directional microwave antennas are mounted side by-side on an equatorial mount which tracks the sun. One antenna is aimed directly at the sun to provide a sun temperature, and the other antenna is aimed at a slight angle to the sun antenna to provide a sky temperature reference. Signals from the two antennas are compared in a radiometric detecting system and provide information concerning solar activity and atmospheric attenuation and emission.

Haroules, G. G.↗

Development of a high power microwave thruster, with a magnetic nozzle, for space applications

This paper describes the current development of a high-power microwave electrothermal thruster (MET) concept at the NASA Lewis Research Center. Such a thruster would be employed in space for applications such as orbit raining, orbit maneuvering, station change, and possibly trans-lunar or trans-planetary propulsion of spacecraft. The MET concept employs low frequency continuous wave (CW) microwave power to create and continuously pump energy into a flowing propellant gas at relative high pressure via a plasma discharge. The propellant is heated to very high bulk temperatures while passing through the plasma discharge region and then is expanded through a throat-nozzle assembly to produce thrust, as in a conventional rocket engine. Apparatus, which is described, is being assembled at NASA Lewis to test the MET concept to CW power levels of 30 kW at a frequency of 915 MHz. The microwave energy is applied in a resonant cavity applicator and is absorbed by a plasma discharge in the flowing propellant. The ignited plasma acts as a lossy load, and with optimal tuning, energy absorption efficiencies over 95 percent (based on the applied microwave power) are expected. Nitrogen, helium, and hydrogen will be tested as propellants in the MET, at discharge chamber pressures to 10 atm.

Power, John L.↗

Apparatus for and method of compensating dynamic unbalance

An apparatus to stabilize a fine platform that carries a parabolic reflecting dish, utilized in connection with the large aperture, multichannel microwave radiometer, is discussed. It provides compensation for dynamic unbalance imparted to a fixed body by a shaft about which the rotating body rotates. Force components exerted on the fixed body by the rotating body in a plane at right angles to the axis are determined. In response to the determined force components, the rotational speed and effective direction of mass means mounted on the rotating body are controlled. The mass means has an effective axis of rotation in a plane at right angles to the longitudinal axis.

Hrastar, J. A.↗

Geodetic distance measuring apparatus

A mode locked laser system including a laser device and its peripheral components is utilized for deriving two mutually phase locked optical wavelength signals and one phase locked microwave CW signal which respectively traverse the same distance measurement path. Preferably the optical signals are comprised of pulse type signals. Phase comparison of the two optical wavelength pulse signals is used to provide a measure of the dry air density while phase comparison of one of the optical wavelength pulse signals and the microwave CW signal is used to provide a measure of the wet or water vapor density of the air. From these measurements is computed in means of the distance to be measured corrected for the atmospheric dry and water vapor densities in the measurement path.

Abshire, J. B.↗

Method and means for generation of tunable laser sidebands in the far-infrared region

A method for generating tunable far-infrared radiation is described. The apparatus includes a Schottky-barrier diode which has one side coupled through a conductor to a waveguide that carries a tunable microwave frequency; the diode has an opposite side which is coupled through a radiating whisker to a bias source. Infrared light is directed at the diode, and infrared light with tunable sidebands is radiated by the whisker through an open space to a reflector. The original infrared is separated from a tunable infrared sideband by a polarizing Michelson interferometer.

Pickett, Herbert M.↗

Microwave Electrothermal Propulsion for Space

The microwave electrothermal thruster (MET) concept for medium or high-power spacecraft propulsion is described. The MET employs continuous wave microwave energy to create and maintain a plasma discharge in a flowing propellant gas. The discharge then acts to absorb the applied microwave energy and transform it into thermal and internal energy of the propellant. Expansion and expulsion of the hot propellant through a throat and nozzle finally converts the energy of the gas into thrust. The MET concept is electrodeless, synergistically combines high pressure and high power capability, provides external control over the energy-conversion discharge, and operates on hydrogen propellant. The potential performance of the MET on hydrogen propellant has been modeled with a two-dimensional kinetics computer code. The MET concept is particularly suitable for use with a magnetic nozzle. Apparatus is described for testing the resonant-cavity MET to power levels of 30 kW at 915 MHz on nitrogen, helium, and hydrogen. The low-ripple operation of the microwave generator has been verified, as has a procedure for starting the microwave discharge and raising the power applied to the cavity via a phase shifter-tuner.

Power, John L.↗

Investigation of mechanical and thermal properties of microwave-sintered lunar simulant materials using 2.45 GHz radiation

The mechanical and thermal properties of lunar simulant material were investigated. An alternative method of examining thermal shock in microwave-sintered lunar samples was researched. A computer code was developed that models how the fracture toughness of a thermally shocked lunar simulant sample is related to the sample hardness as measured by a micro-hardness indentor apparatus. This technique enables much data to be gathered from a few samples. Several samples were sintered at different temperatures and for different times at the temperatures. The melting and recrystallization characteristics of a well-studied binary system were also investigated to see if the thermodynamic barrier for the nucleation of a crystalline phase may be affected by the presence of a microwave field. The system chosen was the albite (sodium alumino silicate) anorthite system (calcium alumino silicate). The results of these investigations are presented.

Meek, T. T.↗

Electron-temperature dependence of dissociative recombination of electrons with CO/+/./CO/n-series ions

The dependence on electron temperature of the coefficients for electron recombination with molecular cluster ions of the carbon monoxide series, CO(+).(CO)n, is determined. A microwave discharge lasting approximately 0.1 msec was applied in 5-20 Torr neon containing a few tenths percent CO in an afterglow mass spectrometer apparatus, and the time histories of the various afterglow ions were measured. Expressions for the dependence of the recombination coefficients of the dimer and trimer ions CO(+).CO and CO(+).(CO)2 are obtained which are found to be significantly different from those previously obtained for hydronium and ammonium series polar cluster ions, but similar to those of simple diatomic ions.

Whitaker, M.↗