Search NASA⌕ Search

SEARCH · Search NASA

Results for “MOLECULAR PUMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Intensity-dependent circular polarization and circumstellar magnetic fields from the observation of SiO masers

A new aspect of the propagation of astrophysical maser radiation in the presence of a magnetic field is described in which circular polarization is created. The resulting antisymmetric spectral line profile for this circular polarization resembles that produced by the ordinary Zeeman effect when the Zeeman splittings are much less than the spectral line breadth. It is caused by the change, with increasing maser intensity, in the axis of symmetry for the molecular quantum states from a direction that is parallel to the magnetic field to a direction that is parallel to the direction of propagation. When the maser is radiatively saturated, and the rate for stimulated emission is within an order of magnitude of the Zeeman splitting in frequency units, this 'intensity-dependent circular polarization' is greater than that due to the ordinary Zeeman effect by factors as large as 1000. The circular polarization that is observed in the spectra of circumstellar SiO (J = 1-0) masers associated with late-type giants and supergiants may then be caused by magnetic fields as weak as about 10 mG. With the standard Zeeman interpretation of the observations, magnetic fields of 10-100 G are indicated. The lower fields are similar to the limits obtained from the observation of the 22 GHz water masers which are typically somewhat further from the central star. The observed tendency for the fractional linear polarization of SiO masers to increase with increasing angular momentum of the molecular state is shown to be a likely result of anisotropic pumping. Errors are identified that invalidate a recent conflicting claim in the literature about the basic theory of maser polarization in the regime that is relevant here.

Nedoluha, Gerald E.↗

High spectral resolution lidar to measure optical scattering properties of atmospheric aerosols. I - Theory and instrumentation

A high spectral resolution lidar technique to measure optical scattering properties of atmospheric aerosols is described. Light backscattered by the atmosphere from a narrowband optically pumped oscillator-amplifier dye laser is separated into its Doppler broadened molecular and elastically scattered aerosol components by a two-channel Fabry-Perot polyetalon interferometer. Aerosol optical properties, such as the backscatter ratio, optical depth, extinction cross section, scattering cross section, and the backscatter phase function, are derived from the two-channel measurements.

Shipley, S. T.↗

Electronic transition CN laser

A 20 kW electric-discharge pumped CN laser oscillating on the A(2) Pi-X(2) Sigma molecular system is presented. Excitation is by a simple longitudinal discharge struck through HCN vapor. Twenty kW peak power is generated in a 150 nsec full-width half-maximum pulse. Two lasing bands were observed in the A-X system: the (0,1) and (0,2) bands near 1.42 and 2.0 microns respectively. Both P and Q branches are active in the two bands, with Q bands stronger. Peak laser energy is 3 mJ. Products of UV photolysis of HCN, electron impact excitation of HCN, and other possible excitation mechanisms and laser efficiency are discussed.

Quick, C. R., Jr.↗

Radiation energy conversion in space; Conference, 3rd, NASA Ames Research Center, Moffett Field, Calif., January 26-28, 1978, Technical Papers

Concepts for space-based conversion of space radiation energy into useful energy for man's needs are developed and supported by studies of costs, material and size requirements, efficiency, and available technology. Besides the more studied solar power satellite system using microwave transmission, a number of alternative space energy concepts are considered. Topics covered include orbiting mirrors for terrestrial energy supply, energy conversion at a lunar polar site, ultralightweight structures for space power, radiatively sustained cesium plasmas for solar electric conversion, solar pumped CW CO2 laser, superelastic laser energy conversion, laser-enhanced dynamics in molecular rate processes, and electron beams in space for energy storage.

Billman, K. W.↗

Interstellar bullets - H2O masers and Herbig-Haro objects

The paper considers the energy input to H2O masers in a dense molecular cloud and analyzes the response time scales for both collisional and radiative pump models. Specific mechanisms for magnetic energy input are given. The evolution of dense H2O maser clouds is studied in the environment of a young pre-main-sequence star that has developed an appreciable supersonic wind. It is shown that compact clouds can be ejected at high velocity to distances of order 1 pc. It is suggested that these clouds (referred to as interstellar bullets) might explain the phenomena of Herbig-Haro objects and high-velocity gas motions observed near compact infrared objects.

Norman, C.↗

Ultra-high molecular sink vacuum chamber

Double-wall vacuum chamber can be separated from the remainder of the system and pumped by ultra-clean techniques. Ultrahigh vacuum is maintained by the cryogenic effect of a cold wall and titanium chemisorption.

Stephens, J. B.↗

Buffer Gas Experiments in Mercury (Hg+) Ion Clock

We describe the results of the frequency shifts measured from various buffer gases that might be used as a buffer gas to increase the loading efficiency and cooling of ions trapped in a small mercury ion clock. The small mass, volume and power requirement of space clock precludes the use of turbo pumps. Hence, a hermetically sealed vacuum system, incorporating a suitable getter material with a fixed amount of inert buffer gas may be a practical alternative to the groundbased system. The collision shifts of 40,507,347.996xx Hz clock transition for helium, neon and argon buffer gases were measured in the ambient earth magnetic field. In addition to the above non-getterable inert gases we also measured the frequency shifts due to getterable, molecular hydrogen and nitrogen gases which may be used as buffer gases when incorporated with a miniature ion pump. We also examined the frequency shift due to the low methane gas partial pressure in a fixed higher pressure neon buffer gas environment. Methane gas interacted with mercury ions in a peculiar way as to preserve the ion number but to relax the population difference in the two hyperfine clock states and thereby reducing the clock resonance signal. The same population relaxation was also observed for other molecular buffer gases (N H ,) but at much reduced rate.

mercury ion clock↗

Diffusion pump modification promotes self-cleansing and high efficiency

Modifications eliminate contaminant substances from pump fluid during operation, which are principal causes of torpidity on evaporative surface. Diffusion pump is also acting as still. Resulting 100 percent vigorous working surface provides much greater molecular throughput and greatly improved efficiency.

Buggele, A. E.↗

Apparatus Removes Organic Contaminants From Water

Catalytic-oxidation apparatus removes low-molecular-weight, polar, nonionizable organic contaminants from wastewater. Wastewater stream, previously treated by multifiltration process, pumped through apparatus for removal of trace organic contaminants. After injection of oxygen, flow preheated and enters catalytic reactor, where organic contaminants broken down into carbon dioxide and water. Carbon dioxide and unused oxygen removed in degasser.

Akse, James R.↗

Low background focal plane array testing in the far infrared

A new long-wavelength infrared test facility is being developed to conduct proof-of-performance tests of focal plane arrays for the Infrared Astronomical Satellite (IRAS) telescope. This facility is believed to be unique in that it will calibrate full-sized arrays designed for the 5-120-micron region of the IR spectrum under simulated spaceflight conditions and at background levels as low as 8 million photons/sq cm-sec. Most of the tests will be performed in a main test chamber which contains a liquid helium shroud, blackbody sources, an arrangement to simulate zodiacal background, and spot scanning optics. A noncontaminating high-vacuum pumping system will be used to evacuate the chamber prior to cool-down to prevent molecular deposition. All housekeeping and focal plane signal outputs are multiplexed, digitized, and transmitted on high-speed data lines to a PDP-11/70 computer. The computer provides real-time displays on a color CRT terminal and stores data for subsequent reduction and hard copy output. An overview of the conceptual design and performance specifications of the test facility are given.

Iufer, E. J.↗

Pulsed-discharge carbon dioxide lasers

The purpose is to attempt a general introduction to pulsed carbon dioxide lasers of the kind used or proposed for laser radar applications. Laser physics is an excellent example of a cross-disciplinary topic, and the molecular spectroscopy, energy transfer, and plasma kinetics of the devices are explored. The concept of stimulated emission and population inversions is introduced, leading on to the molecular spectroscopy of the CO2 molecule. This is followed by a consideration of electron-impact pumping, and the pertinent energy transfer and relaxation processes which go on. Since the devices are plasma pumped, it is necessary to introduce a complex subject, but this is restricted to appropriate physics of glow discharges. Examples of representative devices are shown. The implications of the foregoing to plasma chemistry and gas life are discussed.

Willetts, David V.↗

Degradation of the lunar vacuum by a moon base

Several industrial processes requiring high and ultra-high vacuum similar to the lunar vacuum are outlined. The effects of a 20-person lunar base and a 250-person industrial facility on this vacuum are discussed. It is shown that exhaust from transport spacecraft and leakage from the habitat will be comparable to the daytime gas pressure for the 20-person base, and will degrade the vacuum to the range of 2 x 10 to the -9th torr for the use of 250-person facility. This will result in replacing the mostly nonreactive gases hydrogen, helium, and neon with more reactive gases containing carbon and oxygen. This vacuum is still good enough to perform many important vacuum processes such as plasma-deposition of amorphous silicon for solar cells, but processes such as molecular beam epitaxy or locating an intersecting beam accelerator on the moon will require additional vacuum pumping.

Landis, Geoffrey↗

NASA Tech Briefs, January 2008

Topics covered include: Induction Charge Detector with Multiple Sensing Stages; Generic Helicopter-Based Testbed for Surface Terrain Imaging Sensors; Robot Electronics Architecture; Optimized Geometry for Superconducting Sensing Coils; Sensing a Changing Chemical Mixture Using an Electronic Nose; Inertial Orientation Trackers with Drift Compensation; Microstrip Yagi Antenna with Dual Aperture-Coupled Feed; Patterned Ferroelectric Films for Tunable Microwave Devices; Micron-Accurate Laser Fresnel-Diffraction Ranging System; Efficient G(sup 4)FET-Based Logic Circuits; Web-Enabled Optoelectronic Particle-Fallout Monitor; SiO2/TiO2 Composite for Removing Hg from Combustion Exhaust; Lightweight Tanks for Storing Liquefied Natural Gas; Hybrid Wound Filaments for Greater Resistance to Impacts; Making High-Tensile-Strength Amalgam Components; Bonding by Hydroxide-Catalyzed Hydration and Dehydration; Balanced Flow Meters without Moving Parts; Deflection-Compensating Beam for Use inside a Cylinder; Four-Point-Latching Microactuator; Curved Piezoelectric Actuators for Stretching Optical Fibers; Tunable Optical Assembly with Vibration Dampening; Passive Porous Treatment for Reducing Flap Side-Edge Noise; Cylindrical Piezoelectric Fiber Composite Actuators; Patterning of Indium Tin Oxide Films; Gimballed Shoulders for Friction Stir Welding; Improved Thermal Modulator for Gas Chromatography; Nuclear-Spin Gyroscope Based on an Atomic Co-Magnetometer; Utilizing Ion-Mobility Data to Estimate Molecular Masses; Optical Displacement Sensor for Sub-Hertz Applications; Polarization/Spatial Combining of Laser-Diode Pump Beams; Spatial Combining of Laser-Diode Beams for Pumping an NPRO; Algorithm Optimally Orders Forward-Chaining Inference Rules; Project Integration Architecture; High Power Amplifier and Power Supply; Estimating Mixing Heights Using Microwave Temperature Profiler; and Multiple-Cone Sunshade for a Spaceborne Telescope.

Source record↗

NASA Tech Briefs, May 2007

Topics include: Noise-Canceling Helmet Audio System; Program Analyzes Spacecraft/Ground Radio Links; Two-Way Communication Using RFID Equipment and Techniques; Six-Message Electromechanical Display System; Scanning Terahertz Heterodyne Imaging Systems; Master Clock and Time-Signal-Distribution System; Synchronous Phase-Resolving Flash Range Imaging; Integrated Radial Probe Transition From MMIC to Waveguide; Bar-Code System for a Microbiological Laboratory; MMIC Amplifier Produces Gain of 10 dB at 235 GHz; Mapping Nearby Terrain in 3D by Use of a Grid of Laser Spots; Digital Beam Deflectors Based Partly on Liquid Crystals; Narrow-Band WGM Optical Filters With Tunable FSRs; Better Finite-Element Analysis of Composite Shell Structures; Computing Spacecraft-Pointing Vectors for Limb Tracking; Enhanced Master Controller Unit Tester; Rover Graphical Simulator; Increasing Durability of Flame-Sprayed Strain Gauges; Multifunctional, High-Temperature Nanocomposites; Multilayer Impregnated Fibrous Thermal Insulation Tiles; Radiation-Shielding Polymer/Soil Composites; Film/Adhesive Processing Module for Fiber-Placement Processing of Composites; Fabrication of Submillimeter Axisymmetric Optical Components; Electrochemical Disposal of Hydrazines in Water; Statistical Model of Evaporating Multicomponent Fuel Drops; Resistively Heated SiC Nozzle for Generating Molecular Beams; Compact Packaging of Photonic Millimeter-Wave Receiver; Diffractive Combiner of Single-Mode Pump Laser-Diode Beams; Wide-Band, High-Quantum-Efficiency Photodetector; A Robustly Stabilizing Model Predictive Control Algorithm; Modeling Evaporation of Drops of Different Kerosenes; Development of Vapor-Phase Catalytic Ammonia Removal System; Several Developments in Space Tethers; Design Concept for a Nuclear Reactor-Powered Mars Rover; Formation-Initialization Algorithm for N Spacecraft; and DNSs of Multicomponent Gaseous and Drop-Laden Mixing Layers Achieving Transition to Turbulence.

Source record↗

Portable Microleak-Detection System

The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

Rivers, H. Kevin↗

Infrared upconversion for astronomical applications

The performance of an upconversion system is examined for observation of astronomical sources in the low to middle infrared spectral range. Theoretical values for the performance parameters of an upconversion system for astronomical observations are evaluated in view of the conversion efficiencies, spectral resolution, field of view, minimum detectable source brightness and source flux. Experimental results of blackbody measurements and molecular absorption spectrum measurements using a lithium niobate upconverter with an argon-ion laser as the pump are presented. Estimates of the expected optimum sensitivity of an upconversion device which may be built with the presently available components are given.

Abbas, M. M.↗

Contamination effects from materials selected for spacecraft instruments

Measurements of the Total Mass Loss (TML) and the Collected Volatile Condensable Materials (CVCM) are used as a guide for selecting those materials being low in outgassing. A contamination modelling method utilizing the data and also the rate at which a material outgasses in a system with a known conductance has been developed and has been applied to the problem encountered with the Very High Resolution Radiometer (VHRR). Recently, the contamination model has been applied to the problem with the 5th band of the Multi-Spectral Scanner on the Landsat-C satellite. In the MSS design, the volumes involved and their respective conductance in a molecular flow field demonstrated that the water vapor adsorbed and absorbed by an epoxy paint was being pumped off and re-ad(b)sorbed, with a resultant very slow loss of water during each degassing temperature cycle of the instrument's cooler. Recommendations for designing improved coolers are presented.

Heslin, T. M.↗

Line emission from clumpy photodissociation regions

A theoretical parameter study of dense photodissociation regions is presented. It is found that when the gas density is sufficiently high relative to the FUV flux, self-shielding of the molecules can move the C(+)/CO and H/H2 atomic-molecular transitions close to the surfaces of the molecular cloud, where they can feel the full effect of heating by the FUV radiation field. For n of 100,000/cu cm, collisional deexcitation of the FUV-pumped H2 can move the lower levels toward the LTE, producing line ratio resembling those of shocked regions for these low-v levels, while the high-v level line ratios retain a 'fluorescent' value. Appreciable emission in high-J transitions of CO originates in this warm molecular gas. Comparison with observations suggests that a small volume filling factor of high density clumps embedded within a moderate density interclump medium are a common phenomenon in photodissociation regions.

Burton, Michael G.↗