Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Field Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Superconducting Fourfold Fe(Te,Se) Film on Sixfold Magnetic MnTe via Hybrid Symmetry Epitaxy

Epitaxial Fe(Te,Se) thin films have been grown on various substrates but never been grown on magnetic layers. In this work, we report the epitaxial growth of fourfold Fe(Te,Se) film on a sixfold antiferromagnetic insulator, MnTe. The Fe(Te,Se)/MnTe heterostructure shows a clear superconducting transition at around 11 K, and the critical magnetic field measurement suggests the origin of the superconductivity to be bulk-like. Structural characterizations suggest that the uniaxial lattice match between Fe(Te,Se) and MnTe allows a hybrid symmetry epitaxy mode, which was recently discovered between Fe(Te,Se) and Bi 2 Te 3 . Furthermore, the Te/Fe flux ratio during deposition of the Fe(Te,Se) layer is found to be critical for its superconductivity. Now that superconducting Fe(Te,Se) can be grown on two related hexagonal platforms, Bi 2 Te 3 and MnTe, this result opens a new possibility of combining topological superconductivity of Fe(Te,Se) with the rich physics in the intrinsic magnetic topological materials (MnTe) n (Bi 2 Te 3 ) m family.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic order and disorder in a quasi-two-dimensional quantum Heisenberg antiferromagnet with randomized exchange

In this work, we present an investigation of the effect of randomizing exchange coupling strengths in the S = 1 / 2 square lattice quasi-two-dimensional quantum Heisenberg antiferromagnet (QHAF) ( QuinH ) 2 Cu ( Cl x Br 1 - x ) 4 · 2 H 2 O (QuinH = Quinolinium, C 9 H 8 N + ), with 0 ≤ x ≤ 1 . Pulsed-field magnetization measurements allow us to estimate an effective in-plane exchange strength J in a regime where exchange fosters short-range order, while the temperature T N at which long-range order (LRO) occurs is found using muon-spin relaxation, allowing us to construct a phase diagram for the series. We evaluate the effectiveness of disorder in suppressing T N and the ordered moment size, and we find an extended disordered phase in the region 0.4 ≲ x ≲ 0.8 where no magnetic order occurs. The observed critical substitution levels are accounted for by an energetics-based competition between different local magnetic orders. Furthermore, we demonstrate experimentally that the ground-state disorder is driven by quantum effects of the exchange randomness, which is a feature that has been predicted theoretically and has implications for other disordered quasi-two-dimensional QHAFs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field quality of the 4.5 m-long MQXFA pre-series magnets for the HL-LHC Upgrade as observed during magnet assembly

We report that the U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) is developing MQXFA magnets, a series of 4.5 m long 150 mm aperture high-field Nb 3 Sn quadrupole magnets for the HL-LHC upgrade at CERN. Five pre-series magnets, MQXFA03 through MQXFA07, have been developed. During the magnet assembly stage, we perform magnetic measurements on the coil-pack sub-assembly and magnets after loading to track the field quality for two purposes. First, it serves as a quality assurance tool to check if the magnetic field quality is on track to meet the acceptance criteria. Magnetic measurements are used to understand if magnetic shims are needed to compensate low-order field errors and to meet the field quality targets. Second, the measurements during the assembly stage can also help understand the field quality, especially the geometric field errors, for Nb 3 Sn accelerator magnets. Here we summarize the measurement results of the pre-series MQXFA magnets, including the magnetic axis and twist angle. The results will provide useful feedback for the series production of Nb 3 Sn magnets and on the optimization of field quality of accelerator magnets based on the wind-and-react Nb 3 Sn technology.

43 PARTICLE ACCELERATORS↗

Diffusion Quantum Monte Carlo Benchmarking of Magnetic Moments in MnBi 2 Te 4

The intrinsically antiferromagnetic topological insulator, MnBi 2 Te 4 (MBT), has garnered significant attention recently due to its potential to host numerous exotic topological quantum states. Unfortunately, their consistent realization has been hindered by intrinsic antisite defects among the Mn and Bi sublattices. In this work, we establish Mn magnetization of pristine MBT through high level diffusion Monte Carlo calculations, which can serve as a precise starting point for various models to estimate antisite defect concentrations in actual MBT samples. The benchmark quality of DMC calculations is further identified from out model estimating antisite defect concentrations, which combines the benchmarked Mn magnetization with data from magnetic susceptibility and intermediate field magnetization measurements. This reproduces well Bi Mn and Mn Bi concentrations measured in the experiments. Here, we anticipate these theoretically based magnetic purity measures may be used as minimization targets in cycles of refinement to synthesize MBT with low antisite defect concentrations and more reproducible topological properties.

Defects↗

High repetition rate mapping of the interaction between a laser plasma and magnetized background plasma via laser induced fluorescence

In this work, the laminar coupling of energy between a laser-produced plasma and a background magnetized plasma was investigated via planar laser induced fluorescence diagnostic and magnetic flux probes. Experiments performed on the Large Plasma Device at the University of California, Los Angeles, mapped out the two-dimensional spatiotemporal evolution of the laser-plasma (debris) ion velocity distribution function (VDF) to assess debris-background coupling in a sub-Alfvénic regime. The acquisition of these data necessitates high repetition rate (1 Hz) as each dataset is the accumulation of thousands of laser shots, which would not be feasible in single-shot experiments. Fully kinetic, three-dimensional particle-in-cell simulations are compared to the measured VDFs to provide a framework in which we can understand the coupling of a sub-Alfvénic plasma flow through a preformed, magnetized plasma. The simulations display the same departure from the expected gyromotion of the debris plasma as observed in the experimental data, and in conjunction with the measured magnetic field traces, have led to the direct observation of the collisionless coupling via laminar fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual-phase superconductivity in high-pressure high-temperature synthesized TaNbZrHfTi

We report on a novel TaNbZrHfTi-based high entropy alloy (HEA) which demonstrates distinctive dual-phase superconductivity. The HEA was synthesized under high pressures and high temperatures starting from a ball milled mixture of elemental metals in a large-volume Paris–Edinburgh cell with P ≈ 6 GPa and T = 2300 K. The synthesized HEA is a phase mixture of BCC (NbTa)0.45(ZrHfTi)0.55 with Tc1 = 6 K and FCC (NbTa)0.04(ZrHfTi)0.96 with Tc2 = 3.75 K. The measured magnetic field parameters for the HEA are lower critical field, Hc1(0) = 31 mT, and a relatively high upper critical field, Hc2(0) = 4.92 T. This dual-phase system is further characterized by the presence of a second magnetization peak, or the fishtail effect, observed in the virgin magnetization curves. This phenomenon, which does not distort the field-dependent magnetization hysteresis loops, suggests intricate pinning mechanisms that could be potentially tuned for optimized performance. The manifestation of these unique features in HEA superconductivity reinforces phase-dependent superconductivity and opens new avenues in the exploration of novel superconducting materials.

Materials Science↗

Reassembly and Test of High-Field Nb3Sn Dipole Demonstrator MDPCT1

In the framework of the U.S. Magnet Development Program (MDP), Fermilab has developed and tested a high-field Nb$_3$Sn dipole demonstrator MDPCT1 for a post-LHC Hadron Collider. The magnet was first assembled with a lower coil pre-load to minimize the risk of coil damage during assembly and test. In the first test the magnet reached its test goal producing a world record field of 14.1 T at 4.5 K. Next the magnet was reassembled with nominal pre-load to achieve its design field limit of 15 T. This paper describes the details of MDPCT1 inspection, design modifications and reassembly. The magnet quench performance, including training, ramp rate and temperature dependences in the temperature range of 1.9-4.5 K, is presented and discussed.

43 PARTICLE ACCELERATORS↗

Performance of a MQXF Nb 3 Sn Quadrupole Magnet Under Different Stress Level

In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e. that coil unloading during the ramp does not prevent reaching higher currents. This issue is particularly relevant for Nb 3 Sn magnets, where the loads applied to the Nb3Sn filaments can reach the degradation limits of critical current. In order to investigate the impact of coil preload on the quench performance, the MQXFS6 short model quadrupole for the High Luminosity Upgrade was tested under an azimuthal preload at 80% of the short sample current, reaching 93% of short sample current at 1.9 K. The preload was then released to 60%, still showing ability to operate in the range of 80-85% of short sample current as required by HL-LHC project. With this lower preload, the ability of going above 90% of short sample was lost, and a significant training appeared above 85%. When the preload was restored to the original 80% value, the magnet reached with few quenches 95% of short sample (13.4 T peak field). Magnetic measurements confirm the larger movement of the coil in the case with lower preload, and agree with finite element simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Speed Active Integrators for Magnetic Probes

This report discusses a low cost, easy to develop instrument to measure magnetic fields in pulsed solenoids used for the MagNIF pulse power system. The instrument is designed to integrate voltage signals from custom B-dot probes made from PCB inductor chips. The instrument is battery powered with ± 9V rails. Acceptable B-dot probe inputs range from mV to 20V with frequencies up to 4MHz. Details of the circuit design and practical considerations for working with high speed signals are discussed.

42 ENGINEERING↗

A Data-driven, Physics-based Transport Model of Solar Energetic Particles Accelerated by Coronal Mass Ejection Shocks Propagating through the Solar Coronal and Heliospheric Magnetic Fields

Abstract In an effort to develop computational tools for predicting radiation hazards from solar energetic particles (SEPs), we have created a data-driven physics-based particle transport model to calculate the injection, acceleration, and propagation of SEPs from coronal mass ejection (CME) shocks traversing through the solar corona and interplanetary magnetic fields. The model runs on an input of corona and heliospheric plasma and magnetic field configuration from a magnetohydrodynamic model driven by solar photospheric magnetic field measurements superposed with observed CME shocks determined from coronagraph images. SEP source particles are injected at the shock using the result of diffusive shock acceleration formulation from a characteristic obliquity-dependent injection from a heated solar wind thermal tail population. With several advanced computation techniques involving stochastic simulation and integration, the model obtains the particle intensity at any location in interplanetary space through the rigorous solution to the time-dependent 5D focus transport equation in the phase space that includes perpendicular diffusion. We apply the model to the 2011 November 3 CME event. The calculation results reproduce multispacecraft SEP observations at Earth and STEREO-B reasonably well without normalization of particle flux. The observations at STEREO-A can be reproduced by rescaling particle energy or modified energy dependence of particle diffusion coefficients. This circumsolar SEP event seen by spacecraft at Earth, STEREO-A, and STEREO-B at widely separated longitudes can be explained by diffusive shock acceleration by a single CME shock with a moderate speed.

79 ASTRONOMY AND ASTROPHYSICS↗

High-sensitivity multi-channel atomic magnetometer

High-sensitivity multi-channel atomic magnetometers are described. Methods for operating multi-channel atomic magnetometers are also described. Moreover, devices incorporating a plurality of multi-channel atomic magnetometers are described. A multi-channel atomic magnetometer may use the spin-exchange relaxation-free (SERF) technique. A multi-channel atomic magnetometer may achieve multi-channel operation in a single module, reducing the cost of sensors. A multi-channel atomic magnetometer may be a 16-channel atomic magnetometer. A multi-channel atomic magnetometer may include a single large vapor cell including alkali-metal atoms and at least one buffer gas that restricts motion of atomic spins of the alkali-metal atoms, thereby making relatively small internal cell volumes act as a multiple independent local sensing channels. A multi-channel atomic magnetometer may include a broad pump beam that simultaneously polarizes all (or substantially all) of the alkali-metal atoms in each internal sensing volume of the vapor cell, and a broad probe beam that simultaneously measures magnetic fields at multiple sensing volumes with a photodiode array.

Kim, Young Jin↗

Cryogenic goniometer for measurements in pulsed magnetic fields fabricated via additive manufacturing technique

Complex high-precision mechanical devices can be fabricated using 3-dimensional printing technology with the help of computer-aided design. Using 3D stereolithography, we have constructed a cryogenic goniometer for measurements in pulsed magnetic fields of up to 100 T, at temperatures as low as 0.5 K. We review the properties of several materials tested in developing the goniometer and report on its design and performance. The goniometer allows samples to be rotated in situ to a precision of 0.2 deg, so that the field can be applied at many different angles to the samples’ symmetry directions. Following its success, we establish that 3D printing is now a viable technology for pulsed-field and other cryogenic probes.

3D printing↗

Local measurements of the spatial magnetic field distribution in a z-pinch plasma during and near stagnation using polarization spectroscopy

We present here the detailed measurements of radial distribution of the magnetic field in a gas-puff z-pinch plasma at the final stages of the implosion phase and at stagnation. While the measurements are chordal, the radial distribution of different charge states was utilized to measure the magnetic field locally for certain radii, so that unlike chordal measurements in general, the magnetic field radial distribution was obtained with no need for the Abel inversion of the data. The distribution was measured using the Zeeman effect via a novel spectroscopic technique, at several axial locations, and demonstrates striking features such as the peak field remaining at a radius much larger than the stagnation radius at all times. Furthermore, while the distribution observed is sometimes monotonic with respect to the radius, it is often not, a behavior that can be linked to 2D features in the plasma column resulting from the Rayleigh–Taylor instability. The current flowing through the stagnating plasma was found to be a small fraction of the total current, resulting in clearly insufficient magnetic pressure to balance the plasma pressure at stagnation. The magnetic field data, taken over several axial positions, are used to obtain the true inductance in the imploding plasma for the first time; it is found that the data cannot explain the current turnover at stagnation. A simulation with the MACH2-Tabular Collisional-Radiative Equilibrium magnetohydrodynamics code in the r–z plane shows that the peak of the magnetic field pinches to a much smaller radius than is observed in the spectroscopic data. Furthermore, the depth of the computed current turnover at stagnation is smaller than the measured one. The two observed features of a radially extended magnetic field at stagnation together with a deep current turnover are a challenge to match in simulations. Various calculations and estimates of the inductive and resistive load voltages are examined to ascertain if they are responsible for the observed current notch. Lastly, the results demonstrate that the knowledge of the true inductance in the driven load requires such magnetic-field-distribution measurements and that imaging data or electrical measurements are insufficient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Flexible Field Mapping System for Accelerator Magnets

Magnetic field mapping is a fundamental magnetic measurement method that typically uses Hall and NMR sensors. In magnet measurement facilities, such systems are likely used in various configurations suitable for a specific task at hand. To address this diversity, the authors developed a flexible field mapping system capable of being configured and tailored to each particular measurement case. Further, the system needs to address the variability introduced by differences in sensors and their readout systems, probe positioning systems, power supply systems, and required mapping geometry (mapping space and grid, measurement steps and sequences). Although the discussed field mapping systems range from a self-propelled multi-sensor mapper of a large detector magnet to a single 3D Hall sensor system to scan a small permanent magnet, they were all built with the same core mapping system. The variability present in field mapping systems, the measurement system architecture addressing this variability, as well as examples of several field mapping systems built in this architecture are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phasing Magnet for CSX-2 Beamline at NSLS-II

A phasing magnet has been developed at National Synchrotron Light Source II (NSLS-II) for the Coherent Soft X-ray Scattering (CSX) beamline. The phasing magnet will be located at the center of the straight section in between two identical and independent variably polarized APPLE-II devices. Based on Permanent Magnet technology, the phasing magnet has been designed to achieve the required electron beam delay to properly adjust the phase matching of these two consecutive EPUs (Elliptically Polarizing Undulators) and ensure a positive interference between the photon beam emitted in each device. Also this paper will describe the mechanical and magnetic design together with the final field measurements and magnetic tuning results. Also, the spectral performance of the two EPUs and the method used to properly set the field strength of the phasing magnet for any given radiation wavelength and polarization mode will be presented as well.

36 MATERIALS SCIENCE↗

Measurements of extended magnetic fields in laser-solid interaction

Magnetic fields generated from a laser-foil interaction are measured with high fidelity using a proton radiography scheme with x-ray fiducials. In contrast to prior findings under similar experimental conditions, this technique reveals the self-generated, Biermann-battery fields extend beyond the edge of the expanding plasma plume to a radius of over 3.5 mm by t = + 1.4 ns. An analysis of two monoenergetic proton populations confirms that proton deflection is dominated by magnetic fields far from the interaction ( > 2 mm) and electric fields are insignificant. The results are not captured in state-of-the-art magnetohydrodynamics simulations and suggest the need to consider additional physics mechanisms for the magnetic field generation and transport in laser-solid interactions. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of Local Magnetic Fields in Actinide Tetrafluorides

Fluorine-19 magnetic shielding tensors have been measured in a series of actinide tetrafluorides (AnF4) by solid state nuclear magnetic resonance (NMR) spectroscopy. Tetravalent actinide centers with 0 to 8 valence electrons can form tetrafluorides with the same unit cell, making these compounds an attractive choice for a systematic study of the variation in electronic structure across the 5f row of the Periodic Table. Pronounced deviations from predictions based on localized valence electron models have been detected by these experiments, which suggests that this approach may be used as a quantitative probe of electronic correlations.

Walter, Eric D.↗

Local measurement of internal magnetic field fluctuations in high-performance tokamaks

This is the final report for DOE Grant DE-FG02-08ER54984. The overall goal of this project was to develop the cross-polarization scattering (CPS) diagnostic to measure core localized magnetic turbulence in fusion research devices. Section 1 provides a brief overview of project objectives and accomplishments. Section 2 gives a more detailed description of the Project accomplishments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗