Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Resonance Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Discriminative analysis of schizophrenia patients using graph convolutional networks: A combined multimodal MRI and connectomics analysis

Introduction Recent studies in human brain connectomics with multimodal magnetic resonance imaging (MRI) data have widely reported abnormalities in brain structure, function and connectivity associated with schizophrenia (SZ). However, most previous discriminative studies of SZ patients were based on MRI features of brain regions, ignoring the complex relationships within brain networks. Methods We applied a graph convolutional network (GCN) to discriminating SZ patients using the features of brain region and connectivity derived from a combined multimodal MRI and connectomics analysis. Structural magnetic resonance imaging (sMRI) and resting-state functional magnetic resonance imaging (rs-fMRI) data were acquired from 140 SZ patients and 205 normal controls. Eighteen types of brain graphs were constructed for each subject using 3 types of node features, 3 types of edge features, and 2 brain atlases. We investigated the performance of 18 brain graphs and used the TopK pooling layers to highlight salient brain regions (nodes in the graph). Results The GCN model, which used functional connectivity as edge features and multimodal features (sMRI + fMRI) of brain regions as node features, obtained the highest average accuracy of 95.8%, and outperformed other existing classification studies in SZ patients. In the explainability analysis, we reported that the top 10 salient brain regions, predominantly distributed in the prefrontal and occipital cortices, were mainly involved in the systems of emotion and visual processing. Discussion Our findings demonstrated that GCN with a combined multimodal MRI and connectomics analysis can effectively improve the classification of SZ at an individual level, indicating a promising direction for the diagnosis of SZ patients. The code is available at https://github.com/CXY-scut/GCN-SZ.git .

Chen, Xiaoyi↗

Deblurring

In most instances, traditional EEG methodology provides insufficient spatial detail to identify relationships between brain electrical events and structures and functions visualized by magnetic resonance imaging or positron emission tomography. This article describes a method called Deblurring for increasing the spatial detail of the EEG and for fusing neurophysiologic and neuroanatomic data. Deblurring estimates potentials near the outer convexity of the cortex using a realistic finite element model of the structure of a subject's head determined from their magnetic resonance images. Deblurring is not a source localization technique and thus makes no assumptions about the number or type of generator sources. The validity of Deblurring has been initially tested by comparing deblurred data with potentials measured with subdural grid recordings. Results suggest that deblurred topographic maps, registered with a subject's magnetic resonance imaging and rendered in three dimensions, provide better spatial detail than has heretofore been obtained with scalp EEG recordings. Example results are presented from research studies of somatosensory stimulation, movement, language, attention and working memory. Deblurred ictal EEG data are also presented, indicating that this technique may have future clinical application as an aid to seizure localization and surgical planning.

Non-NASA Center↗

Noninvasive analysis of human neck muscle function

STUDY DESIGN. Muscle use evoked by exercise was determined by quantifying shifts in signal relaxation times of T2-weighted magnetic resonance images. Images were collected at rest and after exercise at each of two intensities (moderate and intense) for each of four head movements: 1) extension, 2) flexion, 3) rotation, and 4) lateral flexion. OBJECTIVE. This study examined the intensity and pattern of neck muscle use evoked by various movements of the head. The results will help elucidate the pathophysiology, and thus methods for treating disorders of the cervical musculoskeletal system. SUMMARY OF BACKGROUND DATA. Exercise-induced contrast shifts in T2 has been shown to indicate muscle use during the activity. The noninvasive nature of magnetic resonance imaging appears to make it an ideal approach for studying the function of the complex neuromuscular system of the neck. METHODS. The extent of T2 increase was examined to gauge how intensely nine different neck muscles or muscle pairs were used in seven subjects. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation was assessed to infer the pattern of use among and within individual neck muscles or muscle pairs. RESULTS. Signal relaxation increased with exercise intensity for each head movement. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation also increased with exercise load. Neck muscles or muscle pairs extensively used to perform each head movement were: extension--semispinalis capitis and cervicis and splenius capitis; flexion--sternocleidomastoid and longus capitis and colli; rotation--splenius capitis, levator scapulae, scalenus, semispinalis capitis ipsilateral to the rotation, and sternocleidomastoid contralateral; and lateral flexion--sternocleidomastoid CONCLUSION. The results of this study, in part, agree with the purported functions of neck muscles derived from anatomic location. This also was true for the few selected muscles that have been examined in human electromyographic studies. Neck muscle function and morphology can be studied at a detailed level using exercise-induced shifts in magnetic resonance images.

NASA Program Space Physiology and Countermeasures↗

Estradiol associations with brain functional connectivity in postmenopausal women

Abstract Objective Previous studies have found that estrogens play a role in functional connectivity in the brain; however, little research has been done regarding how estradiol is associated with functional connectivity in postmenopausal women. The purpose of this study was to examine the relationship between estradiol and functional connectivity in postmenopausal women. Methods Structural and blood oxygenation level–dependent resting-state magnetic resonance imaging scans of 88 cognitively healthy postmenopausal individuals were obtained along with blood samples collected the same day as the magnetic resonance imaging to assess hormone levels. We generated connectivity values in CONN toolbox version 20.b, an SPM-based software. Results A regression analysis was run using estradiol level and regions of interest (ROI), including the hippocampus, parahippocampus, dorsolateral prefrontal cortex, and precuneus. Estradiol level was found to enhance parahippocampal gyrus anterior division left functional connectivity during ROI-to-ROI regression analysis. Estradiol enhanced functional connectivity between the parahippocampal gyrus anterior division left and the precuneus as well as the parahippocampal gyrus anterior division left and parahippocampal gyrus posterior division right. An exploratory analysis showed that years since the final menstrual period was related to enhanced connectivity between regions within the frontoparietal network. Conclusions These results illustrated the relationship between estradiol level and functional connectivity in postmenopausal women. They have implications for understanding how the functioning of the brain changes for individuals after menopause that may eventually lead to changes in cognition and behavior in older ages.

Obstetrics & Gynecology↗

Radio and optical interferometric imaging

Since diffraction-limited imaging with a single aperture yields angular resolution approx. lambda/D, the attainment of high angular resolution with single apertures requires the construction of correspondingly large monolithic apertures, the whole surface of which must be figured to much less than a wavelength. At the longer wavelengths, it is impossible to build a sufficiently large single aperture: for example, at lambda 21 cm, arcsec resolution requires an aperture of diameter approx. 50 km. At the shorter wavelengths, the atmosphere imposes a natural limit in resolution of about one arcsec. However, another route is possible; that is, using synthetic apertures to image the sky. Synthetic apertures are now in use in many fields, e.g., radio interferometry, radar imaging, and magnetic-resonance imaging. Radio-interferometric techniques developed in radio astronomy over the past 40 years are now being applied to optical and IR astronomical imaging by a number of groups. Furthermore, the problem of figuring synthetic apertures is considerably simpler, and can be implemented in a computer: new 'self-calibration' techniques allow imaging even in the presence of phase errors due to the atmosphere.

Cornwell, Tim J.↗

Noninvasive Techniques for Intracranial Pressure Assessment: A Review from Aerospace Medicine Perspective

Microgravity-induced changes in fluid distribution and other physiological factors due to space flight have been implicated as the cause of increased intracranial pressure (ICP) in a number of space crewmembers. The modest levels of ICP elevation and absence of severe symptoms in this group do not warrant invasive diagnostic interventions. However, the long-term trends and residual or consequential changes secondary to the observed ICP elevation in this group are not yet known. Therefore, close attention is needed to evaluate the potential techniques of noninvasively assessing ICP, including those feasible for in-flight use. Of particular interest is continuity between ground and in-flight testing, whereby data from the same or different techniques allow reasonably dependable estimation of ICP trends and responses. Methods: A thorough review of current literature, analysis of NASA data, and interviews with subject matter experts were conducted to construct a presentation that reflects the state of the art for noninvasive ICP measurement and monitoring. Results: Multiple imaging and non-imaging modalities are available to assess ICP in terrestrial clinical and experimental environments. Imaging alternatives include magnetic resonance imaging (MRI) and high-resolution sonography. Non-imaging techniques include transcranial Doppler, certain audiological methods, and venous ophthalmodynamometry, among others. Special functional techniques have been proposed recently that allow the use of advanced MRI methods to calculate ICP in addition to the acquisition of high-resolution images. Our data include many of these applications, with several cases of correlation with lumbar puncture, the invasive "gold standard" measurement of ICP.

Hamilton, Douglas R.↗

Imaging Modalities Relevant to Intracranial Pressure Assessment in Astronauts: A Case-Based Discussion

Introduction: Intracranial pressure (ICP) elevation has been inferred or documented in a number of space crewmembers. Recent advances in noninvasive imaging technology offer new possibilities for ICP assessment. Most International Space Station (ISS) partner agencies have adopted a battery of occupational health monitoring tests including magnetic resonance imaging (MRI) pre- and postflight, and high-resolution sonography of the orbital structures in all mission phases including during flight. We hypothesize that joint consideration of data from the two techniques has the potential to improve quality and continuity of crewmember monitoring and care. Methods: Specially designed MRI and sonographic protocols were used to image eyes and optic nerves (ON) including the meningeal sheaths. Specific crewmembers multi-modality imaging data were analyzed to identify points of mutual validation as well as unique features of complementary nature. Results and Conclusion: Magnetic resonance imaging (MRI) and high-resolution sonography are both tomographic methods, however images obtained by the two modalities are based on different physical phenomena and use different acquisition principles. Consideration of the images acquired by these two modalities allows cross-validating findings related to the volume and fluid content of the ON subarachnoid space, shape of the globe, and other anatomical features of the orbit. Each of the imaging modalities also has unique advantages, making them complementary techniques.

Sargsyan, Ashot E.↗

Correlation of Injury Simulation with Clinical Assessment of Traumatic Brain Injury

This report contains a summary of our efforts to correlate head injury simulations predicting intracranial fluid cavitation with clinical assessments of brain injury from blunt impact to the head. Magnetic resonance imaging (MRI) data, collected on traumatic brain injury (TBI) subjects by researchers at the MIND Institute of New Mexico, was acquired for the current work. Specific blunt impact TBI case histories were selected from the TBI data for further study and possible correlation with simulation. Both group and single-subject case histories were examined. We found one single-subject case that was particularly suited for correlation with simulation. Diffusion tensor image (DTI) analysis of the TBI subject identified white matter regions within the brain displaying reductions in fractional anisotropy (FA), an indicator of local damage to the white matter axonal structures. Analysis of functional magnetic resonance image (fMRI) data collected on this individual identified localized regions of the brain displaying hypoactivity, another indicator of brain injury. We conducted high fidelity simulations of head impact experienced by the TBI subject using the Sandia head-neck-torso model and the shock physics computer code CTH. Intracranial fluid cavitation predictions were compared with maps of DTI fractional anisotropy and fMRI hypoactivity to assess whether a possible correlation exists. The ultimate goal of this work is to assess whether one can correlate simulation predictions of intracranial fluid cavitation with the brain injured sites identified by the fMRI and DTI analyses. The outcome of this effort is described in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effects of Long Duration Bed Rest as a Spaceflight Analogue on Resting State Sensorimotor Network Functional Connectivity and Neurocognitive Performance

Long duration spaceflight has been associated with detrimental alterations in human sensorimotor systems and neurocognitive performance. Prolonged exposure to a head-down tilt position during long duration bed rest can resemble several effects of the microgravity environment such as reduced sensory inputs, body unloading and increased cephalic fluid distribution. The question of whether microgravity affects other central nervous system functions such as brain functional connectivity and its relationship with neurocognitive performance is largely unknown, but of potential importance to the health and performance of astronauts both during and post-flight. The aims of the present study are 1) to identify changes in sensorimotor resting state functional connectivity that occur with extended bed rest exposure, and to characterize their recovery time course; 2) to evaluate how these neural changes correlate with neurocognitive performance. Resting-state functional magnetic resonance imaging (rsfMRI) data were collected from 17 male participants. The data were acquired through the NASA bed rest facility, located at the University of Texas Medical Branch (Galveston, TX). Participants remained in bed with their heads tilted down six degrees below their feet for 70 consecutive days. RsfMRI data were obtained at seven time points: 7 and 12 days before bed rest; 7, 50, and 65 days during bed rest; and 7 and 12 days after bed rest. Functional connectivity magnetic resonance imaging (fcMRI) analysis was performed to measure the connectivity of sensorimotor networks in the brain before, during, and post-bed rest. We found a decrease in left putamen connectivity with the pre- and post-central gyri from pre bed rest to the last day in bed rest. In addition, vestibular cortex connectivity with the posterior cingulate cortex decreased from pre to post bed rest. Furthermore, connectivity between cerebellar right superior posterior fissure and other cerebellar regions decreased from pre bed rest to the last day in bed rest. In contrast, connectivity within the default mode network remained stable over the course of bed rest. We also utilized a battery of behavioral measures including spatial working memory tasks and measures of functional mobility and balance. These behavioral measurements were collected before, during, and after bed rest. We will report the preliminary findings of correlations observed between brain functional connectivity and behavioral performance changes. Our results suggest that sensorimotor brain networks exhibit decoupling with extended periods of reduced usage. The findings from this study could aid in the understanding and future design of targeted countermeasures to alleviate the detrimental health and neurocognitive effects of long-duration spaceflight.

Cassady, K.↗

Global brain activity and its coupling with cerebrospinal fluid flow is related to tau pathology

Abstract INTRODUCTION Factors responsible for the deposition of pathological tau in the brain are incompletely understood. This study links macroscale tau deposition in the human brain to cerebrospinal fluid (CSF) flow dynamics using resting‐state functional magnetic resonance imaging (rsfMRI). METHODS Low‐frequency (< 0.1 Hz) resting‐state global brain activity is coupled with CSF flow and potentially reflects CSF dynamics‐related clearance. We examined the correlation between rsfMRI measures of CSF inflow and global activity (gBOLD–CSF coupling) as a predictor, interacting with amyloid beta (Aβ), of tau and cortical thickness (dependent variables) across Alzheimer's Disease Neuroimaging Initiative (ADNI) participants from cognitively unimpaired through mild cognitive impairment (MCI) and Alzheimer's disease (AD). RESULTS Tau deposition in Aβ+ participants, accompanied by cortical thinning and cognitive decline, is associated with decreased gBOLD–CSF coupling. Tau mediates the relationship between coupling and thickness. DISCUSSION Findings suggest that resting‐state global brain activity and CSF movements comodulate Alzheimer's tau deposition, presumably related to CSF clearance. Highlights A non‐invasive functional magnetic resonance imaging (fMRI) assessment of a CSF clearance‐related process is carried out. Global brain activity is coupled with CSF inflow in human fMRI during resting state. Global fMRI–CSF coupling is correlated with tau in Alzheimer's disease (AD). This coupling measure is also associated with cortical thickness, mediated by tau.

Neurosciences & Neurology↗

Positron emission tomography harmonization in the Alzheimer's Disease Neuroimaging Initiative: A scalable and rigorous approach to multisite amyloid and tau quantification

Abstract INTRODUCTION A key goal of the Alzheimer's Disease NeuroImaging Initiative (ADNI) positron emission tomography (PET) Core is to harmonize quantification of β‐amyloid (Aβ) and tau PET image data across multiple scanners and tracers. METHODS We developed an analysis pipeline (Berkeley PET Imaging Pipeline, B‐PIP) for ADNI Aβ and tau PET images and applied it to PET data from other multisite studies. Steps include image pre‐processing, refacing, magnetic resonance imaging (MRI)/PET co‐registration, visual quality control (QC), quantification of tracer uptake, and standardization of Aβ and tau standardized uptake value ratios (SUVrs) across tracers. RESULTS Measurements from 10,105 cross‐sectional and longitudinal Aβ and tau PET scans acquired in several studies between 2010 and 2024 can be processed, harmonized, and directly merged across tracers and cohorts. DISCUSSION The B‐PIP developed in ADNI is a scalable image harmonization approach used in several observational studies and clinical trials that facilitates rigorous Aβ and tau PET quantification and data sharing. Highlights Quantitative results from ADNI Aβ and tau PET data are generated using a rigorous, scalable image processing pipeline This pipeline has been applied to PET data from several other large, multisite studies and trials Quantitative outcomes are harmonizable across studies and are shared with the scientific community

Neurosciences & Neurology↗

Plug-and-Play Methods for Integrating Physical and Learned Models in Computational Imaging: Theory, algorithms, and applications

Plug-and-play (PnP) priors constitute one of the most widely used frameworks for solving computational imaging problems through the integration of physical models and learned models. PnP leverages high-fidelity physical sensor models and powerful machine learning methods for prior modeling of data to provide state-of-the-art reconstruction algorithms. PnP algorithms alternate between minimizing a data fidelity term to promote data consistency and imposing a learned regularizer in the form of an image denoiser. Recent highly successful applications of PnP algorithms include biomicroscopy, computerized tomography (CT), magnetic resonance imaging (MRI), and joint ptychotomography. This article presents a unified and principled review of PnP by tracing its roots, describing its major variations, summarizing main results, and discussing applications in computational imaging. Additionally, we also point the way toward further developments by discussing recent results on equilibrium equations that formulate the problem associated with PnP algorithms.

97 MATHEMATICS AND COMPUTING↗

Imaging Sequences for Hyperpolarized Solids

Hyperpolarization is one of the approaches to enhance Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI) signal by increasing the population difference between the nuclear spin states. Imaging hyperpolarized solids opens up extensive possibilities, yet is challenging to perform. The highly populated state is normally not replenishable to the initial polarization level by spin-lattice relaxation, which regular MRI sequences rely on. This makes it necessary to carefully “budget” the polarization to optimize the image quality. In this paper, we present a theoretical framework to address such challenge under the assumption of either variable flip angles or a constant flip angle. In addition, we analyze the gradient arrangement to perform fast imaging to overcome intrinsic short decoherence in solids. Hyperpolarized diamonds imaging is demonstrated as a prototypical platform to test the theory.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular Imaging of Matrix Metalloproteinase-2 in Atherosclerosis Using a Smart Multifunctional PET/MRI Nanoparticle

Matrix metalloproteinases from macrophages are important intraplaque components that play pivotal roles in plaque progression and regression. This study sought to develop a novel multifunctional positron emission tomography (PET) and magnetic resonance imaging (MRI) contrast agents based on MMP-2 cleavable nanoparticles to noninvasive assessment of MMP-2 activity in mouse carotid atherosclerotic plaques. Macrophage-rich vascular lesions were induced by carotid ligation plus high-fat diet and streptozotocin-induced diabetes in CL57/BL6 mice. To render iron oxide nanoparticles (IONP) specific for the extracellular MMP-2, the magnetic nanoparticle base material has been derivatized with 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA) for the nuclear tracer 64 Cu labeling and the MMP-2-cleavable peptide modified with polyethylene glycol 2000, yielding a multi-modality reporter ( 64 Cu-NOTA-IONP@MMP2c-PEG2K, MMP2cNPs) for PET/MR imaging. Small animal PET imaging and biodistribution data revealed that MMP2cNPs exhibited remarkable plaque uptake (3.06 ± 0.87% ID/g and 1.83 ± 0.28% ID/g at 4 and 12 h, respectively). And MMP2cNPs were rapidly cleared from the contralateral normal carotid artery, resulting in excellent plaque-to-normal carotid artery contrasts. Furthermore, in vivo MRI showed a preferential accumulation of MMP2cNPs in atherosclerotic lesions compared with the non-cleavable reference compound, MMP2ncNPs. In addition, histological analyses revealed iron accumulations in the carotid atherosclerotic plaque, in colocalization with MMP-2 expression and macrophages. Using a combination of innovative imaging modalities, in this study, we demonstrate the feasibility of applying the novel smart MMP2cNPs as a PET/MR hybrid imaging contrast agent for detection of MMP-2 in atherosclerotic plaque in vivo.

60 APPLIED LIFE SCIENCES↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Conceptual design of HTS magnets for fusion nuclear science facility

Second-generation high temperature superconductors (HTS) are available for producing >20 T at the magnet bore compared to 13–16 T for lower temperature superconducting (LTS) toroidal field magnets proposed in recent fusion energy systems studies (FESS) of Fusion Nuclear Science Facility (FNSF). HTS may enable higher fusion power density and smaller device size. High current density cables of multi-layered REBCO tapes have achieved >10 kA at 4–20 K operation in short sample tests for fusion. High current density cables are required for engineering design of FNSF to allow space for interior plasma components. High current density HTS magnets are particularly attractive in reducing the size of a fusion device, beneficial for compact tokamaks, due to their space constraints. Successful HTS magnet development may enable the design of smaller and cheaper fusion pilot plants with a mission of demonstrating net electricity. It may also offer significant cost and performance advantages in non-fusion applicants such as nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Furthermore, we developed HTS magnet design concepts for a compact FNSF radial build in order to define the coil size, winding pack mechanical loading and engineering requirements. Partnering with vendors in the US, PPPL is also testing high current cable prototypes aiming at enabling low cost cable technology toward 100 A/mm 2 engineering current density over the winding pack desired in high field model coil development for compact fusion pilot plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of Vascular Parameter Estimation for Assessing Hypertensive Pregnancy Disorders

Abstract Hypertensive pregnancy disorders (HPDs), such as pre-eclampsia, are leading sources of both maternal and fetal morbidity in pregnancy. Noninvasive imaging, such as ultrasound (US) and magnetic resonance imaging (MRI), is an important tool for predicting and monitoring these high risk pregnancies. While imaging can measure hemodynamic parameters, such as uterine artery pulsatility and resistivity indices (PI and RI), the interpretation of such metrics for disease assessment relies on ad hoc standards, which provide limited insight to the physical mechanisms underlying the emergence of hypertensive pregnancy disorders. To provide meaningful interpretation of measured hemodynamic data in patients, advances in computational fluid dynamics can be brought to bear. In this work, we develop a patient-specific computational framework that combines Bayesian inference with a reduced-order fluid dynamics model to infer parameters, such as vascular resistance, compliance, and vessel cross-sectional area, known to be related to the development of hypertension. The proposed framework enables the prediction of hemodynamic quantities of interest, such as pressure and velocity, directly from sparse and noisy MRI measurements. We illustrate the effectiveness of this approach in two systemic arterial network geometries: an aorta with branching carotid artery and a maternal pelvic arterial network. For both cases, the model can reconstruct the provided measurements and infer parameters of interest. In the case of the maternal pelvic arteries, the model can make a distinction between the pregnancies destined to develop hypertension and those that remain normotensive, expressed through the value range of the predicted absolute pressure.

Biophysics↗

Three-dimensional quantitative flow diagnostics

The principles, capabilities, and practical implementation of advanced measurement techniques for the quantitative characterization of three-dimensional flows are reviewed. Consideration is given to particle, Rayleigh, and Raman scattering; fluorescence; flow marking by H2 bubbles, photochromism, photodissociation, and vibrationally excited molecules; light-sheet volume imaging; and stereo imaging. Also discussed are stereo schlieren methods, holographic particle imaging, optical tomography, acoustic and magnetic-resonance imaging, and the display of space-filling data. Extensive diagrams, graphs, photographs, sample images, and tables of numerical data are provided.

Miles, Richard B.↗