Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mars samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Quantifying Apparent Groundwater Ages near Managed Aquifer Recharge Operations Using Radio-Sulfur ( 35 S) as an Intrinsic Tracer

The application of the cosmogenic radioisotope sulfur-35 ( 35 S) as a chronometer near spreading basins is evaluated at two well-established Managed Aquifer Recharge (MAR) sites: the Atlantis facility (South Africa) and Orange County Water District’s (OCWD’s) Kraemer Basin (Northern Orange County, CA, USA). Source water for both of these sites includes recycled wastewater. Despite lying nearer to the outlet end of their respective watersheds than to the headwaters, 35 S was detected in most of the water sampled, including from wells found close to the spreading ponds and in the source water. Dilution with 35 S-dead continental SO 4 was minimal, a surprising finding given its short ~3 month half-life. The initial work at the Atlantis MAR site demonstrated that remote laboratories could be set up and that small volume samples—saline solutions collected after the resin elution step from the recently developed batch method described below—can be stored and transported to the counting laboratory. This study also showed that the batch method needed to be altered to remove unknown compounds eluted from the resin along with SO 4 . Using the improved batch method, times series measurements of both source and well water from OCWD’s MAR site showed significant temporal variations. Finally, this result indicates that during future studies, monthly to semi-monthly sampling should be conducted. Nevertheless, both of these initial studies suggest the 35 S chronometer may become a valuable tool for managing MAR sites where regulations require minimum retention times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Challenges for coring deep permafrost on earth and mars

A scientific drilling expedition to the High Lake region of Nunavut, Canada, was recently completed with the goals of collecting samples and delineating gradients in salinity, gas composition, pH, pe, and microbial abundance in a 400 m thick permafrost zone and accessing the underlying pristine subpermafrost brine. With a triple-barrel wireline tool and the use of stringent quality assurance and quality control (QA/QC) protocols, 200 m of frozen, Archean, mafic volcanic rock was collected from the lower boundary that separates the permafrost layer and subpermafrost saline water. Hot water was used to remove cuttings and prevent the drill rods from freezing in place. No cryopegs were detected during penetration through the permafrost. Coring stopped at the 535 m depth, and the drill water was bailed from the hole while saline water replaced it. Within 24 hours, the borehole iced closed at 125 m depth due to vapor condensation from atmospheric moisture and, initially, warm water leaking through the casing, which blocked further access. Preliminary data suggest that the recovered cores contain viable anaerobic microorganisms that are not contaminants even though isotopic analyses of the saline borehole water suggests that it is a residue of the drilling brine used to remove the ice from the upper, older portion of the borehole. Any proposed coring mission to Mars that seeks to access subpermafrost brine will not only require borehole stability but also a means by which to generate substantial heating along the borehole string to prevent closure of the borehole from condensation of water vapor generated by drilling.

58 GEOSCIENCES↗

Post-landing major element quantification using SuperCam laser induced breakdown spectroscopy

The SuperCam instrument on the Perseverance Mars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and the continuum signal present in LIBS observations. Prior to quantification, spectra are masked to remove noisier spectrometer regions and spectra are normalized to minimize signal fluctuations and effects of target distance. In some cases, the spectra are also standardized or binned prior to quantification. To determine quantitative elemental compositions of diverse geologic materials at Jezero crater, Mars, we use a suite of 1198 laboratory spectra of 334 well-characterized reference samples. The samples were selected to span a wide range of compositions and include typical silicate rocks, pure minerals (e.g., silicates, sulfates, carbonates, oxides), more unusual compositions (e.g., Mn ore and sodalite), and replicates of the sintered SuperCam calibration targets (SCCTs) onboard the rover. For each major element (SiO 2 , TiO 2 , Al 2 O 3 , FeO T , MgO, CaO, Na 2 O, K 2 O), the database was subdivided into five “folds” with similar distributions of the element of interest. One fold was held out as an independent test set, and the remaining four folds were used to optimize multivariate regression models relating the spectrum to the composition. We considered a variety of models, and selected several for further investigation for each element, based primarily on the root mean squared error of prediction (RMSEP) on the test set, when analyzed at 3 m. In cases with several models of comparable performance at 3 m, we incorporated the SCCT performance at different distances to choose the preferred model. Shortly after landing on Mars and collecting initial spectra of geologic targets, we selected one model per element. Subsequently, with additional data from geologic targets, some models were revised to ensure results that are more consistent with geochemical constraints. The calibration discussed here is a snapshot of an ongoing effort to deliver the most accurate chemical compositions with SuperCam LIBS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ORNL FY22 NCSP Time-of-Flight Measurement [Slides]

This presentation covers the ORNL FY22 NCSP Time-of-Flight measurements. Key take-aways from this presentation include that the process was initiated in FY22. The Lease starts Mar. FY23 (delayed). Finally, that there has been a 30% increase in cost to sample fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Data Loading Manual

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE is primarily funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory. This report is intended to assist the user to enter PRA data into the SAPHIRE program using the built-in MAR-D ASCII-text file data transfer process. Towards this end, a small sample database is constructed and utilized for demonstration. Where applicable, the discussion includes how the data processes for loading the sample database relate to the actual processes used to load a larger PRA models. The procedures described herein were developed for use with SAPHIRE Version 6.0 and Version 7.0. In general, the data transfer procedures for version 6 and 7 are the same, but where deviations exist, the differences are noted. The guidance specified in this document will allow a user to have sufficient knowledge to both understand the data format used by SAPHIRE and to carry out the transfer of data between different PRA projects.

99 GENERAL AND MISCELLANEOUS↗

Glycine Identification in Natural Jarosites Using Laser-Desorption Fourier Transform Mass Spectrometry: Implications for the search for life on Mars

The jarosite group minerals have received increasing attention since the discovery of jarosite by the Mars Exploration Rover-Opportunity on the Martian surface. The mineral group has the ability to incorporate foreign ions in its structure leading to investigations regarding its use as an indicator of aqueous and/or biological activity on Earth and Mars. The use of laser desorption Fourier transform mass spectrometry has revealed the presence of organic matter in several jarosite samples from various worldwide locations. One of the organic cluster ions has been attributed to glycine based on results from combinations of glycine with synthetic jarosite and K2SO4. The ability to observe these organic signatures in jarosite samples with an “in situ” instrumental technique, such as employed in this study, furthers the goals of planetary geologists to determine whether signs of life (e.g., the presence of biomolecules or biomolecule precursors) can be detected in the rock record of terrestrial and extraterrestrial samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ADVANCED RADIOISOTOPE HEAT SOURCE AND PROPULSION SYSTEMS FOR PLANETARY EXPLORATION

The exploration of planetary surfaces and atmospheres may be enhanced by increasing the range and mobility of a science platform. Fundamentally, power production and availability of resources are limiting factors that must be considered for all science and exploration missions. A novel power and propulsion system is considered and discussed with reference to a long-range Mars surface exploration mission with in-situ resource utilization. Significance to applications such as sample return missions is also considered. Key material selections for radioisotope encapsulation techniques are presented.

99 GENERAL AND MISCELLANEOUS↗

Quantitative and sensitive analysis of CN molecules using laser induced low pressure He plasma

We report the results of experimental study on CN 388.3 nm and C I 247.8 nm emission characteristics using 40 mJ laser irradiation with He and N{sub 2} ambient gases. The results obtained with N{sub 2} ambient gas show undesirable interference effect between the native CN emission and the emission of CN molecules arising from the recombination of native C ablated from the sample with the N dissociated from the ambient gas. This problem is overcome by the use of He ambient gas at low pressure of 2 kPa, which also offers the additional advantages of cleaner and stronger emission lines. The result of applying this favorable experimental condition to emission spectrochemical measurement of milk sample having various protein concentrations is shown to yield a close to linear calibration curve with near zero extrapolated intercept. Additionally, a low detection limit of 5 μg/g is found in this experiment, making it potentially applicable for quantitative and sensitive CN analysis. The visibility of laser induced breakdown spectroscopy with low pressure He gas is also demonstrated by the result of its application to spectrochemical analysis of fossil samples. Furthermore, with the use of CO{sub 2} ambient gas at 600 Pa mimicking the Mars atmosphere, this technique also shows promising applications to exploration in Mars.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EFFECT OF PERCHLORATES ON ELECTRON RADIOLYSIS OF GLYCINE WITH APPLICATION TO MARS

This work explores the radiolytic decomposition of glycine (H{sub 2}NCH{sub 2}COOH) under simulated Martian conditions in the presence of perchlorates (ClO{sub 4}{sup −}), which are abundant oxidizers on the surface of Mars, by energetic electrons at 10, 160, 210, and 260 K, mimicking the radiation exposure of the Martian regolith in the first 5–10 cm depths over about 250 million years. Our experiments present quantitative evidence that the rate constants of the glycine decomposition in the presence of magnesium perchlorate hexahydrate (Mg(ClO{sub 4}){sub 2} · 6H{sub 2}O) were a factor of about two higher than that of the pure glycine, suggesting that energetic oxygen atoms (O) released from the ClO{sub 4}{sup −} have a significant effect on the decomposition rates and accelerate them by providing a unique oxidizing environment in the radiolyzed samples. Hence, two decay mechanisms exist: radiolysis by the electrons and oxidation by the O atoms. Within the Mars-relevant temperature range covering 160–260 K, the destruction rates are nearly temperature invariant with rates varying as little as 5%. Further, the formation rates of carbon dioxide (CO{sub 2}) and carbon monoxide (CO) are both accelerated in the presence of ClO{sub 4}{sup −} by a factor of three to five, supporting our conclusion of an active oxygen-initiated chemistry. In addition, the degradation rates are significantly higher than the formation rates of CO{sub 2} and CO. This suggests that, besides the decarboxylation, alternative degradation pathways such as a polymerization of glycine must exist. Finally, besides CO{sub 2} and CO, three alternative products were identified tentatively: methylamine (CH{sub 3}NH{sub 2}), methane (CH{sub 4}), and ammonia (NH{sub 3}).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CALCIUM ISOTOPE COMPOSITION OF METEORITES, EARTH, AND MARS

The relative abundances of calcium isotopes in the mass range 40-44 were measured in primitive and differentiated meteorites and igneous rocks from Earth and Mars in search of non-mass-dependent variations that could provide clues about early solar system processes. Most bulk samples of planetary materials have calcium isotopic compositions identical with Earth's within the current resolution of about 0.01% in {sup 40}Ca/{sup 44}Ca. Possible exceptions include carbonaceous chondrites, some ordinary chondrites, and two samples of calcium-aluminum-rich inclusions, which have small excesses of {sup 40}Ca. The samples with {sup 40}Ca excesses are also known to have {sup 50}Ti and {sup 135}Ba excesses and {sup 142}Nd and {sup 144}Sm deficits. Collectively these data from refractory elements suggest that the planetary embryos represented by chondrites preserve isotopic heterogeneity that reflects different nucleosynthetic sources. No late admixture from a single nucleosynthetic source can explain all observations. The results are most compatible with variable proportions of material derived from Type II supernovae. The initial calcium isotope compositions of Earth and Mars are indistinguishable and similar to the {sup 40}Ca abundance found in some chondrites and all differentiated meteorites studied. It appears that isotopic heterogeneity in calcium was still present at the completion of disk formation but was homogenized during planetary accretion.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical-learning strategies generate only modestly performing predictive models for urinary symptoms following external beam radiotherapy of the prostate: A comparison of conventional and machine-learning methods

Purpose: Given the paucity of available data concerning radiotherapy-induced urinary toxicity, it is important to ensure derivation of the most robust models with superior predictive performance. This work explores multiple statistical-learning strategies for prediction of urinary symptoms following external beam radiotherapy of the prostate. Methods: The performance of logistic regression, elastic-net, support-vector machine, random forest, neural network, and multivariate adaptive regression splines (MARS) to predict urinary symptoms was analyzed using data from 754 participants accrued by TROG03.04-RADAR. Predictive features included dose-surface data, comorbidities, and medication-intake. Four symptoms were analyzed: dysuria, haematuria, incontinence, and frequency, each with three definitions (grade ≥ 1, grade ≥ 2 and longitudinal) with event rate between 2.3% and 76.1%. Repeated cross-validations producing matched models were implemented. A synthetic minority oversampling technique was utilized in endpoints with rare events. Parameter optimization was performed on the training data. Area under the receiver operating characteristic curve (AUROC) was used to compare performance using sample size to detect differences of ≥0.05 at the 95% confidence level. Results: Logistic regression, elastic-net, random forest, MARS, and support-vector machine were the highest-performing statistical-learning strategies in 3, 3, 3, 2, and 1 endpoints, respectively. Logistic regression, MARS, elastic-net, random forest, neural network, and support-vector machine were the best, or were not significantly worse than the best, in 7, 7, 5, 5, 3, and 1 endpoints. The best-performing statistical model was for dysuria grade ≥ 1 with AUROC ± standard deviation of 0.649 ± 0.074 using MARS. For longitudinal frequency and dysuria grade ≥ 1, all strategies produced AUROC>0.6 while all haematuria endpoints and longitudinal incontinence models produced AUROC<0.6. Conclusions: Logistic regression and MARS were most likely to be the best-performing strategy for the prediction of urinary symptoms with elastic-net and random forest producing competitive results. The predictive power of the models was modest and endpoint-dependent. New features, including spatial dose maps, may be necessary to achieve better models.

60 APPLIED LIFE SCIENCES↗

Scatter Removal using Black Body Grids and Determining the Minimum Resolvable Hydrogen Concentration at MARS

This dataset was used to develop and validate a scatter-correction pipeline for neutron radiographs acquired at the MARS beamline, based on the methodology of Carminati et al. (2019). Scatter removal was performed using 36 gadolinium black bodies to characterize and remove the spatially varying neutron scatter field that cannot be eliminated by conventional open-beam normalization. The dataset comprises eight samples - four single-crystal nickel and four polycrystalline austenitic 316L stainless steel. Within each material system, samples were pre-charged with hydrogen gas at four charging pressures (1.5, 5, 12.5, and 20 kpsi). Following scatter correction, the pipeline was applied to all radiographs to recover quantitative attenuation maps. After subtracting the known attenuation contribution of the metal matrix, spatial maps of the hydrogen attenuation coefficient were obtained for each sample. This data was then used to construct a calibration curve relating hydrogen attenuation to hydrogen concentration and to determine the minimum resolvable hydrogen concentration at the MARS beamline. The resulting dataset provides a pressure-resolved calibration standard for quantitative hydrogen mapping using neutron radiography.

36 MATERIALS SCIENCE↗

Combined LIBS-Raman for remote detection and characterization of biological samples

Laser-Induced Breakdown Spectroscopy (LIBS) and Raman Spectroscopy have rich histories in the analysis of a wide variety of samples in both in situ and remote configurations. Our team is working on building a deployable, integrated Raman and LIBS spectrometer (RLS) for the parallel elucidation of elemental and molecular signatures under Earth and Martian surface conditions. Herein, results from remote LIBS and Raman analysis of biological samples such as amino acids, small peptides, mono- and disaccharides, and nucleic acids acquired under terrestrial and Mars conditions are reported, giving rise to some interesting differences. A library of spectra and peaks of interest were compiled, and will be used to inform the analysis of more complex systems, such as large peptides, dried bacterial spores, and biofilms. Lastly, these results will be presented and future applications will be discussed, including the assembly of a combined RLS spectroscopic system and stand-off detection in a variety of environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Petrogenesis, alteration, and shock history of intermediate shergottite Northwest Africa 7042: Evidence for hydrous magmatism on Mars?

We report Northwest Africa (NWA) 7042 is an intermediate, permafic shergottite consisting of two generations of zoned olivine (early olivine Fo 41-76 , and late-stage olivine Fo 46-56 ), complexly zoned pyroxene (En 35-64 Fs 22-46 Wo 5-34 ), maskelynitized feldspar and shock melt (An 5-30 Ab 16-61 Or 1-47 ), and accessory merrillite, apatite, ilmenite, titanomagnetite, Fe-Cr-Ti spinels, pyrrhotite, and baddeleyite. The olivine grains have been pervasively altered resulting in orange-brown stained cores with dark-brown margins, surrounded by significantly less altered overgrowth rims. This textural relationship suggests that the alteration of the cores took place at magmatic temperatures prior to crystallization of the rims on Mars. While this type of olivine alteration is rare in shergottites, it is similar to deuterically altered olivine in basalts and gabbros on Earth, caused by residual water-rich magmatic fluids. Launch-generated shock veins in NWA 7042 crosscut and displace several of the altered olivine grains indicating that the alteration occurred before ejection of the meteorite from Mars. However, NWA 7042 has also been subjected to extensive terrestrial weathering, with terrestrial calcite/barite veins occurring throughout the sample. Transmission electron microscopy analysis of the olivine alteration also reveals an absence of high-temperature phases typically associated with hydrous deuteric alteration on Earth, complicating our interpretation. The potential presence of deuterically altered olivine in NWA 7042 has significant implications, as it is the third martian meteorite where deuteric alteration of olivine has been observed (the others being NWA 10416, ALH 77005). The different mantle sources for the parental melts of these three meteorites would suggest many, if not all martian mantle reservoirs have the potential to produce water-rich magmas.

58 GEOSCIENCES↗

Characterization of Hydrogen in Basaltic Materials With Laser-Induced Breakdown Spectroscopy (LIBS) for Application to MSL ChemCam Data

Here, the Mars Science Laboratory rover, Curiosity , is equipped with ChemCam, a laser–induced breakdown spectroscopy (LIBS) instrument, to determine the elemental composition of nearby targets quickly and remotely. We use a laboratory sample set including prepared mixtures of basalt with systematic variation in hydrated mineral content and compositionally well–characterized, altered basaltic volcanic rocks to measure hydrogen by characterizing the H–alpha emission line in LIBS spectra under Martian environmental conditions. The H contents of all samples were independently measured using thermogravimetric analysis. We found that H peak area increases with weight percent H for our laboratory mixtures with basaltic matrices. The increase is linear with weight percent H in the mixtures with structurally bound H up to about 1.25 wt.% H and then steepens for higher H–content samples, a nonlinear trend not previously reported but potentially important for characterizing high water content materials. To compensate for instrument, environmental, and target matrix–related effects on quantification of H content from the LIBS signal, we examined multiple normalization methods. The best performing methods utilize O 778– and C 248–nm emission lines. The methods return comparable results when applied to ChemCam data of H–bearing materials on Mars. The calibration and normalization methods tested here will aid in investigations of H by LIBS on Mars with ChemCam and SuperCam. Further laboratory work will aid quantification across different physical matrices and heterogeneous textures because of differences we observed in H in pelletized and natural rock samples of the same composition.

58 GEOSCIENCES↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗

Theoretical modeling and analysis of the emission spectra of a ChemCam standard: Basalt BIR-1A

We report here on efforts to perform theoretical modeling of the emission spectrum measured from a basalt sample. We compare our calculations with measurements that were made to provide standards for the ChemCam instrument on the Mars Science Laboratory. We find that to obtain good agreement between modeling and the measurement, it is necessary to determine atomic and ionic level populations via a multi-element approach in which the free electron density that is created influences all the species within the plasma. Calculations that consider each element separately are found to be in poorer agreement with the measured spectrum, indicating that the ‘matrix effect’ term often used to describe the influence of other species on the emission spectrum from a given element is due to the influence of the global electron density of the plasma. We explore the emission features in both the visible and near-infrared wavelength ranges, and also examine radiation transport effects for some of the most intense features found in the basalt spectrum. We also provide comparisons of the ChemCam measurement with new high-resolution spectral measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

ChemCam on MSL 2009: first laser induced breakdown spectrometer for space science

ChemCam is one of the 10 instrument suites on the Mars Science Laboratory, a martian rover being built by Jet Propulsion Laboratory, for the next NASA mission to Mars (MSL 2009). ChemCam is an instrument package consisting of two remote sensing instruments: a Laser-Induced Breakdown Spectrometer (LIBS) and a Remote Micro-Imager (RMI). LIBS provides elemental compositions of rocks and soils, while the RMI places the LIBS analyses in their geomorphologic context. Both instruments rely on an autofocus capability to precisely focus on the chosen target, located at distances from the rover comprised between 1 and 9 m for LIBS, and 2 m and infinity for RMI. ChemCam will help determine which samples, within the vicinity of the MSL rover, are of sufficient interest to use the contact and in-situ instruments for further characterization. It will provide valuable analyses of samples that are inaccessible to contact and in-situ instruments, and of a much larger number of samples than can be done with this kind of instrument. ChemCam also has a capability to provide passive spectroscopy data of rocks and soils on Mars. ChemCam hardware consists of a Mast Unit (MU), provided by France, and a Body Unit (BU) built and tested in the USA. The Flight Model of the MU is assembled, tested and now available in the USA, while the BU is currently being assembled and tested. Both will be connected by the end of year '08 for end-to-end functional and performance tests, before delivery to JPL and assembly on the MSL rover. Launch is scheduled for October 09. After describing the concept of ChemCam, this presentation focuses on its French part, Mast Unit. The results presented show that Mast Unit is able to generate a plasma and collect its light, over the full applicable ranges of distances and temperatures on Mars.

47 OTHER INSTRUMENTATION↗