Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mass loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Mass loading and velocity diffusion models for heavy pickup ions at comet Grigg-Skjellerup

We compare model predictions of cometary water group ion densities and the solar wind slow down with measurements made by the Giotto Johnstone plasma analyzer implanted ion sensor at the encounter with comet Grigg-Skjellerup (G-S) on July 10, 1992. The observed slope of the ion density profile on approach to the comet is unexpectedly steep. Possible explanations for this are discussed. We present also a preliminary investigation of the quasilinear velocity-space diffusion of the implanted heavy ion population at G-S using a transport equation including souce, convection, adiabatic compression, and velocity diffusion terms. Resulting distributions are anisotropic, in agreement with observations. We consider theoretically the waves that may be generated by the diffusion process for the observed solar wind conditions. At initial ion injections, waves are generated at omega approximately Omega(sub i) the ion gyrofrequency, and lower frequencies are predicted for diffusion toward a bispherical shell.

Huddleston, D. E.↗

Structure of mass-loading shocks. 2: Comparison of theory and observation at comet Halley

The multifluid diffusive model of G. P. Zank et al. (1994), which describes the interaction of the solar wind with a cometary plasma in the outer coma, has been used to model the structure of the Halley bow shock. The theoretical results are compared to in situ observations made by Giotto. We compare the solar wind and cometary ion number densities and pressures upstream and through the quasi-perpendicular and quasi-parallel shocks (observed on the inbound and outbound legs of the encounter, respectively). In general, good agreement is found between theory and observations in terms of shock structure, strength, and location, especially for the quasi-parallel shock. The comparison between tha quasi-perpendicular shock observations and theory is complicated by the apparently nonstationary behavior of the shock, a feature which has been remarked upon by other investigators. The cometary bow shock appears to be an excellent example of an energetic-particle-mediated shock where the energetic particles comprise less than 10% of the total number density.

Zank, G. P.↗

Remote query measurement of pressure, fluid-flow velocity, and humidity using magnetoelastic thick-film sensors

Free-standing magnetoelastic thick-film sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted from the sensor in response to a time varying magnetic field. This property allows the sensors to be monitored remotely without the use of direct physical connections, such as wires, enabling measurement of environmental parameters from within sealed, opaque containers. In this work, we report on application of magnetoelastic sensors to measurement of atmospheric pressure, fluid-flow velocity, temperature, and mass load. Mass loading effects are demonstrated by fabrication of a remote query humidity sensor, made by coating the magnetoelastic thick film with a thin layer of solgel deposited Al2O3 that reversibly changes mass in response to humidity. c2000 Elsevier Science S.A. All rights reserved.

NASA Discipline Life Sciences Technologies↗

Calibration of the QCM/SAW Cascade Impactor for Measurement of Ozone

The Quartz Crystal Microbalance Surface Acoustic Wave (QCM/SAW) cascade impactor is an instrument designed to collect size-fractionated distributions of aerosols on a series of quartz crystals and employ SAW devices coated with chemical sensors for gas detection. We are calibrating the cascade impactor in our laboratory for future deployment for in-situ experiments to measure ozone. Experiments have been performed to characterize the QCM and SAW mass loading, saturation limits, mass frequency relationships, and sensitivity. The characteristics of mass loading, saturation limits, mass-frequency relationships, sensitivity, and the loss of ozone on different materials have been quantified.

Williams, Cassandra K.↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗

A spectral formalism for computing three-dimensional deformations due to surface loads. 1: Theory

We outline a complete spectral formalism for computing high spatial resolution three-dimensional deformations arising from the surface mass loading of a spherically symmetric planet. The main advantages of the formalism are that all surface mass loads are always described using a consistent mathematical representation and that calculations of deformation fields for various spatial resolutions can be performed by simpley altering the spherical harmonic degree truncation level of the procedure. The latter may be important when incorporating improved observational constraints on a particular surface mass load, when considering potential errors in the computed field associated with mass loading having a spatial scale unresolved by the observational constraints, or when treating a number of global surface mass loads constrained with different spatial resolutions. The advantages do not extend to traditional 'Green's function' approaches which involve surface element discretizations of the global mass loads. Another advantage of the spectral formalism, over the Green's function approach, is that a posteriori analyses of the computed deformation fields are easily performed. In developing the spectral formalism, we consider specific cases where the Earth's mantle is assumed to respond as an elastic, slightly anelastic, or linear viscoelastic medium. In the case of an elastic or slightly anelastic mantle rheology the spectral response equations incorporate frequency dependent Love numbers. The formalism can therefore be used, for example, to compute the potentially resonant deformational response associated with the free core nutation and Chandler wobble eigenfunctions. For completeness, the spectral response equations include both body forces, as arise from the gravitational attraction of the Sun and the Moon, and surface mass loads. In either case, and for both elastic and anelastic mantle rheologies, we outline a pseudo-spectral technique for computing the ocean adjustment associated with the total gravitational perturbation induced by the external forcing. Three-dimensional deformations computed using the usual Love number approach are generally referenced to an origin at the center of mass of the undeformed planet. We derive a spectral technique for transforming the results to an origin located at the center of mass of the deformed planet.

Mitrovica, J. X.↗

Composition of Pickup Ions at Titan Observed by the Cassini Plasma Spectrometer

Pickup ions have been observed in Saturn's rotating magnetosphere near Titan by the Cassini Plasma Spectrometer (CAPS) instrument during the Cassini orbiter's recent flybys of the moon. A preliminary analysis of the CAPS Time of Flight (TOF) spectra of the pickup ions observed during the TA flyby indicated the presence of H(+), H2(+), N(+)/CH2(+), CH4(+), and N2(+). These ions slow down Saturn's magnetospheric plasma beyond Titan's ionosphere through mass loading. Because of its relatively high mass and high concentration, CH4(+) is the dominant mass loading ion. The other ions make negligible contributions to the mass loading process except for N2(+) just above the ionopause, where its concentration becomes important. With the exception of CH2(+), the pickup ion sources are the neutral exosphere constituents H, H2, N, CH4, and N2, where CH2 is a fragment of the parents CH4 and CH4(+). A more detailed analysis of CAPS TOF spectra and empirical cracking patterns is carried out to determine the relative concentrations of N(+) and CH2(+). Although, the 28 amu ion was identified as N2(+), consistent with the dominance of its neutral source, N2, just above the ionopause, the ionospheric ion HCNH(+) may also be present. The possible leakage of this and other ionospheric ions such as CH5(+) into the pickup ion /mass loading region is also examined by further analysis of the corresponding TOF spectra.

Hartle, R.↗

Effect of isotropic and anisotropic porous microstructure on electrochemical performance of Li ion battery cathodes: An experimental and computational study

Liquid electrolyte mass transport is a major limitation affecting high-power Li ion batteries. Fast discharging causes Li salt depletion in the current collector region of the cathode which produces overpotential in the electrolyte and consequently a drop of cell voltage to below the cut-off voltage, especially at higher electrode thickness and discharge rate. In this study, through experiment and simulation, we have investigated the effect of electrode thickness, mass loading, discharge rate and tortuosity on electrolyte mass transport and final derived areal capacity and specific energy for electrodes having isotropic (normal tape casting) and anisotropic (freeze tape casting) porous microstructure. Furthermore, the macroporous channels in freeze tape cast electrodes facilitate Li salt transport and reduce the Li salt mass transport limitations even at high electrode thickness and discharge rates, and high electrode tortuosity. In our results, computer simulations show that freeze tape cast electrodes may be fully discharged up to 750 μm thickness at 1 C rate compared to 300 μm for normal tape cast electrodes with the same mass loading. Freeze tape cast electrodes also show stable maximum areal capacity for C rates about double the maximum C rates of their normal tape cast electrode counterparts with the same mass loading.

25 ENERGY STORAGE↗

Io's Plasma Environment During the Galileo Flyby: Global Three-Dimensional MHD Modeling with Adaptive Mesh Refinement

The first results for applying a three-dimensional multimedia ideal MHD model for the mass-loaded flow of Jupiter's corotating magnetospheric plasma past Io are presented. The model is able to consider simultaneously physically realistic conditions for ion mass loading, ion-neutral drag, and intrinsic magnetic field in a full global calculation without imposing artificial dissipation. Io is modeled with an extended neutral atmosphere which loads the corotating plasma torus flow with mass, momentum, and energy. The governing equations are solved using adaptive mesh refinement on an unstructured Cartesian grid using an upwind scheme for AHMED. For the work described in this paper we explored a range of models without an intrinsic magnetic field for Io. We compare our results with particle and field measurements made during the December 7, 1995, flyby of to, as published by the Galileo Orbiter experiment teams. For two extreme cases of lower boundary conditions at Io, our model can quantitatively explain the variation of density along the spacecraft trajectory and can reproduce the general appearance of the variations of magnetic field and ion pressure and temperature. The net fresh ion mass-loading rates are in the range of approximately 300-650 kg/s, and equivalent charge exchange mass-loading rates are in the range approximately 540-1150 kg/s in the vicinity of Io.

Combi, M. R.↗

Formulating energy density for designing practical lithium–sulfur batteries

We report the lithium–sulfur (Li–S) battery is one of the most promising battery systems due to its high theoretical energy density and low cost. Despite impressive progress in its development, there has been a lack of comprehensive analyses of key performance parameters affecting the energy density of Li–S batteries. Here, we analyse the potential causes of energy loss during battery operations. We identify two key descriptors (R weight and R energy ) that represent the mass- and energy-level compromise of the full-cell energy density, respectively. A formulation for energy density calculations is proposed based on critical parameters, including sulfur mass loading, sulfur mass ratio, electrolyte/sulfur ratio and negative-to-positive electrode material ratio. The current progress of Ah-level Li–S batteries is also summarized and analysed. Finally, future research directions, targets and prospects for designing practical high-performance Li–S batteries are proposed.

36 MATERIALS SCIENCE↗

Estimation of secondary organic aerosol viscosity from explicit modeling of gas-phase oxidation of isoprene and α -pinene

Abstract. Secondary organic aerosols (SOA) are major components of atmospheric fine particulate matter, affecting climate and air quality. Mounting evidence exists that SOA can adopt glassy and viscous semisolid states, impacting formation and partitioning of SOA. In this study, we apply the GECKO-A (Generator of Explicit Chemistry and Kinetics of Organics in the Atmosphere) model to conduct explicit chemical modeling of isoprene photooxidation and α-pinene ozonolysis and their subsequent SOA formation. The detailed gas-phase chemical schemes from GECKO-A are implemented into a box model and coupled to our recently developed glass transition temperature parameterizations, allowing us to predict SOA viscosity. The effects of chemical composition, relative humidity, mass loadings and mass accommodation on particle viscosity are investigated in comparison with measurements of SOA viscosity. The simulated viscosity of isoprene SOA agrees well with viscosity measurements as a function of relative humidity, while the model underestimates viscosity of α-pinene SOA by a few orders of magnitude. This difference may be due to missing processes in the model, including autoxidation and particle-phase reactions, leading to the formation of high-molar-mass compounds that would increase particle viscosity. Additional simulations imply that kinetic limitations of bulk diffusion and reduction in mass accommodation coefficient may play a role in enhancing particle viscosity by suppressing condensation of semi-volatile compounds. The developed model is a useful tool for analysis and investigation of the interplay among gas-phase reactions, particle chemical composition and SOA phase state.

54 ENVIRONMENTAL SCIENCES↗

Io escape and ionization of atmospheric gases

Exploratory model calculations for the Io atomic oxygen cloud have provided two-dimensional sky-plane intensities for the 6300 A, 1304 A and 880 A lines, where volume excitation and ionization rates are determined by impact collisions with Io plasma torus electrons. Comparison of model results with observations at 6300 A suggests an isotropic oxygen flux from Io of about 1.5x109 atoms 1 sq cm/sec. The effects of including a neutral sulfur cloud and also of including charge exchange reactions between plasma torus ions and neutral OI and SI were evaluated to be significant and were roughly estimated to increase the required oxygen flux to 1.2 x 10 to the 10th atoms/sq cm/sec. In addition, increases in the estimates for the ion loading, cloud mass loss, plasma mass loading and ion energy input rates were also made. Model calculations for an Io sulfur cloud, excluding charge exchange reactions but assuming an SI flux of 7.5 x 10 to the 8th atoms/sq cm/sec (i.e., half of the oxygen flux), were also performed and provided sky plane intensities for a number of visible and IR emission lines.

Smyth, W. H.↗

Life Support Catalyst Regeneration Using Ionic Liquids and In Situ Resources

Oxygen recovery from metabolic carbon dioxide is an enabling capability for long-duration manned space flight. Complete recovery of oxygen (100%) involves the production of solid carbon. Catalytic approaches for this purpose, such as Bosch technology, have been limited in trade analyses due in part to the mass penalty for high catalyst resupply caused by carbon fouling of the iron or nickel catalyst. In an effort to mitigate this challenge, several technology approaches have been proposed. These approaches have included methods to prolong the life of the catalysts by increasing the total carbon mass loading per mass catalyst, methods for simplified catalyst introduction and removal to limit the resupply container mass, methods of using in situ resources, and methods to regenerate catalyst material. Research and development into these methods is ongoing, but only use of in situ resources and/or complete regeneration of catalyst material has the potential to entirely eliminate the need for resupply. The use of ionic liquids provides an opportunity to combine these methods in a technology approach designed to eliminate the need for resupply of oxygen recovery catalyst. Here we describe the results of an initial feasibility study using ionic liquids and in situ resources for life support catalyst regeneration, we discuss the key challenges with the approach, and we propose future efforts to advance the technology.

Abney, Morgan B.↗

Life Support Catalyst Regeneration Using Ionic Liquids and In Situ Resources

Oxygen recovery from metabolic carbon dioxide is an enabling capability for long-duration manned space flight. Complete recovery of oxygen (100%) involves the production of solid carbon. Catalytic approaches for this purpose, such as Bosch technology, have been limited in trade analyses due in part to the mass penalty for high catalyst resupply caused by carbon fouling of the iron or nickel catalyst. In an effort to mitigate this challenge, several technology approaches have been proposed. These approaches have included methods to prolong the life of the catalysts by increasing the total carbon mass loading per mass catalyst, methods for simplified catalyst introduction and removal to limit the resupply container mass, methods of using in situ resources, and methods to regenerate catalyst material. Research and development into these methods is ongoing, but only use of in situ resources and/or complete regeneration of catalyst material has the potential to entirely eliminate the need for resupply. The use of ionic liquids provides an opportunity to combine these methods in a technology approach designed to eliminate the need for resupply of oxygen recovery catalyst. Here we describe the results of an initial feasibility study using ionic liquids and in situ resources for life support catalyst regeneration, we discuss the key challenges with the approach, and we propose future efforts to advance the technology.

Abney, Morgan B.↗

Atmospheric particulate measurements in Norfolk, Virginia

Characterization of atmospheric particulates was conducted at a site near the center of Norfolk, Virginia. Air quality was measured in terms of atmospheric mass loading, particle size distribution, and particulate elemental composition for a period of 2 weeks. The objectives of this study were (1) to establish a mean level of air quality and deviations about this mean, (2) to ascertain diurnal changes or special events in air quality, and (3) to evaluate instrumentation and sampling schedules. Simultaneous measurements were made with the following instruments: a quartz crystal microbalance particulate monitor, a light-scattering multirange particle counter, a high-volume air sampler, and polycarbonate membrane filters. To assess the impact of meteorological conditions on air quality variations, continuous data on temperature, relative humidity, wind speed, and wind direction were recorded. Particulate elemental composition was obtained from neutron activation and scanning electron microscopy analyses of polycarbonate membrane filter samples. The measured average mass loading agrees reasonably well with the mass loadings determined by the Virginia State Air Pollution Control Board. There are consistent diurnal increases in atmospheric mass loading in the early morning and a sample time resolution of 1/2 hour seems necessary to detect most of the significant events.

Storey, R. W., Jr.↗