Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measure control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

In-situ measurement and control of the tool-workpiece interface temperature during friction stir processing of 304/304L stainless steel

Friction stir processing of 304/304L stainless steel is an area of interest for repair of spent nuclear fuel canisters. To enable repair without canister deflection or fracture, it is necessary to define the limitations for the depth of the processing zone which will be critically dependent on the thermal history of the material. Here, this work provides the first direct measurement of the interface temperature for friction stir processing of steel. The measured temperature is in the range of 850–1050 °C which is 20–30 % higher than previously reported values. Notably, the peak temperature occurs at the pin tip which is attributed to a higher sticking fraction and subsequently higher strain rate near the tool axis of rotation. Furthermore, a clear correlation between the temperature, grain size, and hardness is established within a single weld nugget and across different processing conditions. In the future, this data may lead to improved process modelling through direct validation and allow for property optimization through direct microstructure control.

304 stainless steel↗

When Do Efficiency and Demand Flexibility Go Hand-in-hand?

Utilities have been experimenting with integrated demand side management (IDSM) programs since the 2000s. The potential benefits of improved program cost-effectiveness and customer engagement from combining energy efficiency (EE), demand flexibility (DF), and other distributed energy resources into an integrated customer offering have been recognized although there are several known regulatory and program administrative challenges. In addition, as buildings adopt EE measures, the baseline load profile change generally reduces the potential load that can be shed or shifted. This has been a significant technical barrier for customers and program implementers. However, it is a myth that EE always reduces DF. Load change from EE can be time-varying. Therefore, whether EE improves or reduces DF should be evaluated on an individual measure basis accounting for weather dependencies and interactions. For IDSM program design purpose, it is useful to understand how common EE features influence DF and the underlying building physics. In this paper, we use parametric simulations of a prototype medium office building to evaluate how various EE features influence DF, measured by a “demand decrease intensity” (W/ft2) metric. These EE features cover envelope characteristics, internal loads, and airside HVAC system. The parametric analysis shows that some efficient HVAC control measures will increase DF but not the traditional building envelope, lighting, and ventilation-related efficiency measures. These findings contribute to the technical basis for achieving enhanced energy benefits by packaging appropriate HVAC control measures in IDSM program design. Program developers should further validate these results in targeted pilot projects.

Yu, Lili↗

NO x Control and Measurement Technology for Heavy-Duty Diesel Engines (CRADA Final Report)

The Catalyst CRADA focused on lean-NO x trap (LNT) and selective catalytic reduction (SCR) automotive emission control catalyst technology. It particularly had the goal of developing and applying advanced diagnostics capable of elucidating the network and sequence of catalyst reactions, as well as how they are affected by real-world operation and aging. Another overarching goal and action of this CRADA section was to develop methods to quantify and monitor catalyst states and support the development of full and reduced models for design and in-use control applications. William Partridge was the ORNL principal investigator (PI) throughout the Catalyst CRADA; Neal Currier was the Cummins PI through circa 2017, and Saurabh Joshi was the subsequent Cummins PI.

33 ADVANCED PROPULSION SYSTEMS↗

Research on measurement and control of helicopter rotor response using blade-mounted accelerometers 1991-92

Preliminary wind tunnel tests of the hill-size Model 412/IBC rotor at the Ames Research Center, NASA, are described. Blade flapping motion was excited by swash plate oscillation, and the flapping response was measured using blade-mounted accelerometers and compared with flapping motion inferred form blade strain measurements. The recorded open-loop accelerometer signals were used as input to the flapping-IBC system in the laboratory. The resulting controller cyclic pitch outputs are compared with the original cyclic pitch excitation inputs, and the potential effectiveness of the controller in suppressing the original excitation is evaluated. Control of blade flapping excites blade lagging, and vice versa; the paper describes a theoretical investigation of these coupling effects.

Ham, Norman D.↗

Metrology: Measurement Assurance Program Guidelines

The 5300.4 series of NASA Handbooks for Reliability and Quality Assurance Programs have provisions for the establishment and utilization of a documented metrology system to control measurement processes and to provide objective evidence of quality conformance. The intent of these provisions is to assure consistency and conformance to specifications and tolerances of equipment, systems, materials, and processes procured and/or used by NASA, its international partners, contractors, subcontractors, and suppliers. This Measurement Assurance Program (MAP) guideline has the specific objectives to: (1) ensure the quality of measurements made within NASA programs; (2) establish realistic measurement process uncertainties; (3) maintain continuous control over the measurement processes; and (4) ensure measurement compatibility among NASA facilities. The publication addresses MAP methods as applied within and among NASA installations and serves as a guide to: control measurement processes at the local level (one facility); conduct measurement assurance programs in which a number of field installations are joint participants; and conduct measurement integrity (round robin) experiments in which a number of field installations participate to assess the overall quality of particular measurement processes at a point in time.

Eicke, W. G.↗

Performance measures for control computers

As real-time systems become more complex, the problem of controlling them safely becomes more difficult. When computers are in control of time-critical systems such as aircraft, nuclear reactors, and life-support systems, they must meet stringent performance requirements. However, these requirements cannot be properly stated without appropriate performance measures. Such measures are reviewed and analyzed in this paper.

Krishna, C. M.↗

Automatic quadrature control and measuring system

A quadrature component cancellation and measuring system comprising a detection system for detecting the quadrature component from a primary signal, including reference circuitry to define the phase of the quadrature component for detection is described. A Raysistor optical coupling control device connects an output from the detection system to a circuit driven by a signal based upon the primary signal. Combining circuitry connects the primary signal and the circuit controlled by the Raysistor device to subtract quadrature components. A known current through the optically sensitive element produces a signal defining the magnitude of the quadrature component.

Hamlet, J. F.↗

Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes: Measured Data From Select Southeastern States

Little data is available that quantifies IAQ or associates contaminant levels with air exchange in U.S. homes. To address this gap, the U.S. Department of Energy (DOE) Building America Program conducted a study to characterize IAQ in U.S. homes constructed since 2013, along with presence, functionality, and occupant use of control measures. Specific objectives of this study effort included: Measuring time-integrated concentrations and temporal profiles of established contaminants of concern; monitoring the use of ventilation equipment; and tracking activities that impact air pollutant emissions and removal processes in typical homes in various climate zones; Characterizing the prevalence, type, and installed performance of mechanical ventilation equipment in new homes; exploring regional variations in system designs and performance; Investigating associations between contaminant levels and the presence of control measures including whole-house mechanical ventilation (WHMV). The study engaged research teams to collect data at a regional level. This report introduces the study protocol and presents and discusses high-level results obtained from Florida Solar Energy Center (FSEC) data collection efforts in the southeastern U.S. states of Florida, Georgia, and South Carolina.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based evaluation of school- and non-school-related measures to control the COVID-19 pandemic

The role of school-based contacts in the epidemiology of SARS-CoV-2 is incompletely understood. We use an age-structured transmission model fitted to age-specific seroprevalence and hospital admission data to assess the effects of school-based measures at different time points during the COVID-19 pandemic in the Netherlands. Our analyses suggest that the impact of measures reducing school-based contacts depends on the remaining opportunities to reduce non-school-based contacts. If opportunities to reduce the effective reproduction number (R e ) with non-school-based measures are exhausted or undesired and R e is still close to 1, the additional benefit of school-based measures may be considerable, particularly among older school children. As two examples, we demonstrate that keeping schools closed after the summer holidays in 2020, in the absence of other measures, would not have prevented the second pandemic wave in autumn 2020 but closing schools in November 2020 could have reduced R e below 1, with unchanged non-school-based contacts.

60 APPLIED LIFE SCIENCES↗

Controlling the pandemic during the SARS-CoV-2 vaccination rollout

There is a consensus that mass vaccination against SARS-CoV-2 will ultimately end the COVID-19 pandemic. However, it is not clear when and which control measures can be relaxed during the rollout of vaccination programmes. We investigate relaxation scenarios using an age-structured transmission model that has been fitted to age-specific seroprevalence data, hospital admissions, and projected vaccination coverage for Portugal. Our analyses suggest that the pressing need to restart socioeconomic activities could lead to new pandemic waves, and that substantial control efforts prove necessary throughout 2021. Using knowledge on control measures introduced in 2020, we anticipate that relaxing measures completely or to the extent as in autumn 2020 could launch a wave starting in April 2021. Additional waves could be prevented altogether if measures are relaxed as in summer 2020 or in a step-wise manner throughout 2021. We discuss at which point the control of COVID-19 would be achieved for each scenario.

60 APPLIED LIFE SCIENCES↗

Pharmacologic Atrial Natriuretic Peptide Reduces Human Leg Capillary Filtration

Atrial natriuretic peptide (ANP) is produced and secreted by atrial cells. We measured calf capillary filtration rate with prolonged venous-occlusion plethysmography of supine healthy male subjects during pharmacologic infusion of ANP (48 pmol/kg/min for 15 min; n = 6) and during placebo infusion (n = 7). Results during infusions were compared to prior control measurements. ANP infusion increased plasma (ANP) from 30 +/- 4 to 2,568 +/- 595 pmol/L. Systemic hemoconcentration occurred during ANP infusion: mean hematocrit and plasma colloid osmotic pressure increased 4.6 and 11.3%, respectively, relative to preinfusion baseline values (p less than 0.05). Mean calf filtration, however, was significantly reduced from 0.15 to 0.08 ml/100 ml/min with ANP. Heart rate increased 20% with ANP infusion, whereas blood pressure was unchanged. Calf conductance (blood flow/ arterial pressure) and venous compliance were unaffected by ANP infusion. Placebo infusion had no effect relative to prior baseline control measurements. Although ANP induced systemic capillary filtration, in the calf, filtration was reduced with ANP. Therefore, pharmacologic ANP infusion enhances capillary filtration from the systemic circulation, perhaps at upper body or splanchnic sites or both, while having the opposite effect in the leg.

Watenpaugh, Donald E.↗

Measurements, modeling, control and simulation - as applied to the human left ventricle for purposeful physiological monitoring.

Interdisciplinary engineering research effort in studying the intact human left ventricle has been employed to physiologically monitor the heart and to obtain its 'state-of-health' characteristics. The left ventricle was selected for this purpose because it plays a key role in supplying energy to the body cells. The techniques for measurement of the left ventricular geometry are described; the geometry is effectively displayed to bring out the abnormalities in cardiac function. Methods of mathematical modeling, which make it possible to determine the performance of the intact left ventricular muscle, are also described. Finally, features of a control system for the left ventricle for predicting the effect of certain physiological stress situations on the ventricle performance are discussed.

Ghista, D. N.↗

Comparison of computer- and human-derived coronary angiographic end-point measures for controlled therapy trials

The Cholesterol Lowering Atherosclerosis Study, a randomized angiographic clinical trial, demonstrated the beneficial effect of niacin/colestipol plus diet therapy on coronary atherosclerosis. Outcome was determined by panel-based estimates (viewed in both still and cine modes) of percent stenosis severity and change in native artery and bypass graft lesions. Computer-based quantitative coronary angiography (QCA) was also used to measure lesion and bypass graft stenosis severity and change in individual frames closely matched in orientation, opacification, and cardiac phase. Both methods jointly evaluated 350 nonoccluded lesions. The correlation between QCA and panel estimates of lesion size was 0.70 (p less than 0.0001) and for change in lesion size was 0.28 (p = 0.002). Agreement between the two methods in classifying lesion changes (i.e., regression, unchanged, or progression) occurred for 60% (210 of 350) of the lesions kappa +/- SEM = 0.20 +/- 0.05, p less than 0.001). The panel identified 442 nonoccluded lesions for which QCA stenosis measurements could not be obtained. Lesions not measurable by QCA included those with stenosis greater than 85% that could not be reliably edge tracked, segments with diffuse or ecstatic disease that had no reliable reference diameter, and segments for which matched frames could not be located. Seventy-nine lesions, the majority between 21% and 40% stenosis, were identified and measured by QCA but were not identified by the panel. This comparison study demonstrates the need to consider available angiographic measurement methods in relation to the goals of their use.

NASA Center JPL↗

Pharmacologic Atrial Natriuretic Peptide Reduces Human Leg Capillary Filtration

Atrial natriuretic peptide (ANP) is produced and secreted by atrial cells. We measured calf capillary filtration rate with prolonged venous-occlusion plethys-mography of supine health male subjects during pharmacologic infusion of ANP (48 pmol/kg/min for 15 min; n equals 6) and during placebo infusion (n equals 7). Results during infusions were compared to prior control measurements. ANP infusion increased plasma (ANP) from 30 plus or minus 4 to 2,568 plus or minus 595 pmol/L. Systemic hemoconcentration occurred during ANP infusion; mean hematocrit and plasma colloid osmotic pressure increased 4.6 and 11.3 percent respectively, relative to pre-infusion baseline values (p is less than 0.05). Mean calf filtration, however was significantly reduced from 0.15 to 0.08 ml/100 ml/min with ANP. Heart rate increased 20 percent with ANP infusion, wheras blood pressure was unchanged. Calf conductance (blood flow/arterial pressure) and venous compliance were unaffected by ANP infusion. Placebo infusion had no effect relative to prior baseline control measurements. Although ANP induced systemic capillary filtration, in the calf, filtration was reduced with ANP. Therefore, phamacologic ANP infusion enhances capillary filtration from the systemic circulation, perhaps at upper body or splanchic sites or both, while having the opposite effect in the leg.

Watenpaugh, Donald E.↗

No Need to Wait for the Clean Air Dividend

Controlling smog and soot is the classic win-win situation, so it's great that the world is finally waking up to the idea. WHAT if there was a way to simultaneously slow down climate change, save millions of lives, improve crop yields and contribute to sustainable development and energy security? It sounds too good to be true, but it is possible. It won't be free or easy, but with some effort and moderate investment, it can be done. The way to do it is to reduce emissions leading to two types of pollution: black carbon and ozone. These are the only pollutants that we know contribute to both global warming and poor air quality. Black carbon is essentially soot, emitted from incomplete combustion of fossil fuels and biomass. It warms the climate in two ways: by absorbing heat in the atmosphere - similar to the greenhouse effect - and by reducing Earth's albedo, or ability to reflect sunlight. Inhaled into the lungs, it leads to cancer and cardiovascular disease. Ozone in the atmosphere also acts as a greenhouse gas, while ground-level ozone is toxic to humans and plants, so leads to both premature death and reduced crop yields. Ozone is not emitted directly but is produced by the action of sunlight on other pollutants, which are known as ozone precursors. Since black carbon and ozone are important components of soot and smog, a great deal of effort has already been put into developing methods to reduce emissions. So effective technology is available, but needs wider implementation. The recommended control measures for black carbon include widespread and tight emission standards on diesel cars and trucks; improved solid fuel cooking stoves, brick kilns and coke ovens in the developing world; and a ban on the open burning of agricultural waste. Implementation of these measures would have a rapid impact on the climate and human health, and also have the added benefit of greatly reducing emissions of carbon monoxide, an important ozone precursor. A second key ozone precursor is methane, which is also a powerful greenhouse gas in its own right. Control measures include reducing leaks from natural gas pipelines and storage tanks, and capturing it from coal, gas and oil extraction, landfills and wastewater treatment plants. Aeration of rice paddies and manure management can also reduce methane releases. Captured methane can often be sold or turned into power. In Monterrey, Mexico, for example, electricity generated from methane collected from the city landfill powers the public transportation system. So such measures can be beneficial even when ignoring the health and climate effects, as they can contribute to energy security and often pay for themselves. According to calculations by me and my colleagues, phasing in all these measures over the next 20 years would reduce global warming by about 0.5 degC in 2050, half of the projected increase between now and then (Science, vol 335, p 183). Regional benefits would be even greater, as black carbon disrupts rainfall patterns and magnifies warming and melting of snow and ice in parts of the world including the Arctic and the Himalayas. On top of the climate benefits, cutting black carbon and ozone would prevent over 3 million premature deaths from air pollution, and increase yields of staple crops by roughly 50 million tonnes a year. Improved cooking stoves would also decrease the demand for firewood in the developing world, reducing deforestation and freeing up time for those who collect wood - primarily women and children - to pursue other activities such as education. Similarly, improved brick kilns now being used in parts of Latin America and Asia require half as much fuel as traditional ones and are less time-intensive for the operators. This means that in addition to their environmental benefits, these measures can contribute to sustainable and human development. Tackling black carbon and methane is clearly a great idea, so why hasn't it been done already? There are many barriers. The upfront costs of some measures can be prohibitive even when they eventually pay for themselves. But this can be overcome by mechanisms such as international financing of capital costs. For other measures, the costs are typically borne by a few while the benefits accrue to everybody. In such cases civil society and governments must get involved. Governments are starting to act. In February, the US, Canada, Sweden, Bangladesh, Ghana and Mexico launched the Climate and Clean Air Coalition to support implementation of measures like these. This coalition will hopefully expand and achieve rapid, widespread adoption of measures to cut black carbon and ozone. While the climate benefits will be substantial, it is important to note that these measures cannot substitute for cuts in carbon dioxide. Black carbon, ozone, carbon monoxide and methane stay in the atmosphere for a fairly short time - a few days for black carbon and about a decade for methane. They thus respond quickly to emissions changes and give us substantial leverage over near-term climate change. In contrast, carbon dioxide is very long-lived and so responds slowly to emissions changes. This means that cuts have little immediate impact, but it also means they must be made now to avoid disastrous changes later on. Controlling short-lived climate pollutants is thus an issue of fairness. Much as failure to reduce carbon dioxide emissions soon would condemn future generations to disastrous change, failure to reduce near-term climate change condemns those alive today to suffer worsening effects of the sort already seen. Some wonder if we really can do both. We can, and we must.

Shindell, Drew↗

Performance measurement: A tool for program control

Performance measurement is a management tool for planning, monitoring, and controlling as aspects of program and project management--cost, schedule, and technical requirements. It is a means (concept and approach) to a desired end (effective program planning and control). To reach the desired end, however, performance measurement must be applied and used appropriately, with full knowledge and recognition of its power and of its limitations--what it can and cannot do for the project manager. What is the potential of this management tool? What does performance measurement do that a traditional plan vs. actual technique cannot do? Performance measurement provides an improvement over the customary comparison of how much money was spent (actual cost) vs. how much was planned to be spent based on a schedule of activities (work planned). This commonly used plan vs. actual comparison does not allow one to know from the numerical data if the actual cost incurred was for work intended to be done.

Abell, Nancy↗

Experimental Evaluation of Hot Films on Ceramic Substrates for Skin-Friction Measurement

An investigation has been performed on the use of low-thermal conductivity, ceramic substrates for hot films intended to measure skin friction. Hot films were deposited on two types of ceramic substrates. Four hot films used composite-ceramic substrates with subsurface thermocouples (TCs), and two hot films were deposited on thin Macor(R) substrates. All six sensors were tested side by side in the wall of the NASA Glenn Research Center 8-ft by 6-ft Supersonic Wind Tunnel (SWT). Data were obtained from zero flow to Mach 1.98 in air. Control measurements were made with three Preston tubes and two boundary-layer rakes. The tests were repeated at two different hot film power levels. All hot films and subsurface TCs functioned throughout the three days of testing. At zero flow, the films on the high-thermal conductivity Macor(R) substrates required approximately twice the power as those on the composite-ceramic substrates. Skin-friction results were consistent with the control measurements. Estimates of the conduction heat losses were made using the embedded TCs but were hampered by variability in coating thicknesses and TC locations.

Noffz, Gregory K.↗