Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Impact of Suggestive Maneuver Guidance on UAS Pilots Performing the Detect and Avoid Function

This presentation discusses the results of a recent UAS Integration into the NAS human-in-the-loop simulation. In the study, 16 active UAS pilots flew a UAS through civil airspace and were tasked with maintaining well clear from other aircraft in the area. Pilots performed the task with four different detect and avoid (DAA) traffic displays, each of which varied in the form of guidance it provided to pilots The present findings focus on how the different displays impacted pilots' measured response to scripted conflicts with their aircraft. Measured response is made up of several components, each of which help inform our understanding of the pilots' role in the overall detect and avoid task.

detect and avoid↗

Measuring thermomechanical response of large-format printed polymer composite structures via digital image correlation

Large-format additive manufacturing (LFAM) is a branch of additive manufacturing (AM) research with the ability to create large structures typically measuring several meters in scale. LFAM is advantageous for tooling applications, not only because it offers the ability to create complex geometries not easily made using subtractive manufacturing processes, but the cost savings of pelletized feedstock used by these systems result in larger parts printed at faster speeds than traditional AM systems. Fiber reinforced polymer (FRP) is a commonly used feedstock material in LFAM structures because it reduces the distortion experienced during printing. However, FRP introduces highly anisotropic thermomechanical properties and contributes to a nonhomogeneous microstructure that can result in critical distortion of dimensions during tooling. Measuring the global thermomechanical response of LFAM structures requires a more representative method that accounts for not only anisotropic properties but also the nonhomogeneous nature of the final part. This is where traditional techniques to measure thermomechanical response, such as thermomechanical analysis (TMA), fall short as they assume homogeneity. This study evaluated the coefficient of thermal expansion (CTE) of LFAM structures as measured by TMA as compared to a novel digital image correlation oven (DIC Oven) system. The LFAM structures were made from 20 % by weight carbon fiber reinforced acrylonitrile butadiene styrene (CF-ABS). TMA measurements showed significant variations in CTE across a single LFAM bead, confirming the need for a global technique that captures overall thermomechanical response. The CTE values measured using the DIC Oven compared well to average TMA values obtained from localized measurements across the sample. The DIC Oven was also used to quantify the effects of different layer orientations on thermomechanical properties, which cannot be easily captured using TMA. A predictive model was also developed by using localized TMA values across an LFAM bead to predict the overall thermomechanical response of an LFAM structure.

36 MATERIALS SCIENCE↗

Compatibility check of measured aircraft responses using kinematic equations and extended Kalman filter

An extended Kalman filter smoother and a fixed point smoother were used for estimation of the state variables in the six degree of freedom kinematic equations relating measured aircraft responses and for estimation of unknown constant bias and scale factor errors in measured data. The computing algorithm includes an analysis of residuals which can improve the filter performance and provide estimates of measurement noise characteristics for some aircraft output variables. The technique developed was demonstrated using simulated and real flight test data. Improved accuracy of measured data was obtained when the data were corrected for estimated bias errors.

Klein, V.↗

Modal characterization of the ASCIE segmented optics testbed: New algorithms and experimental results

New frequency response measurement procedures, on-line modal tuning techniques, and off-line modal identification algorithms are developed and applied to the modal identification of the Advanced Structures/Controls Integrated Experiment (ASCIE), a generic segmented optics telescope test-bed representative of future complex space structures. The frequency response measurement procedure uses all the actuators simultaneously to excite the structure and all the sensors to measure the structural response so that all the transfer functions are measured simultaneously. Structural responses to sinusoidal excitations are measured and analyzed to calculate spectral responses. The spectral responses in turn are analyzed as the spectral data become available and, which is new, the results are used to maintain high quality measurements. Data acquisition, processing, and checking procedures are fully automated. As the acquisition of the frequency response progresses, an on-line algorithm keeps track of the actuator force distribution that maximizes the structural response to automatically tune to a structural mode when approaching a resonant frequency. This tuning is insensitive to delays, ill-conditioning, and nonproportional damping. Experimental results show that is useful for modal surveys even in high modal density regions. For thorough modeling, a constructive procedure is proposed to identify the dynamics of a complex system from its frequency response with the minimization of a least-squares cost function as a desirable objective. This procedure relies on off-line modal separation algorithms to extract modal information and on least-squares parameter subset optimization to combine the modal results and globally fit the modal parameters to the measured data. The modal separation algorithms resolved modal density of 5 modes/Hz in the ASCIE experiment. They promise to be useful in many challenging applications.

Carrier, Alain C.↗

On Orbit Measurement of Response vs. Scan Angle for the Infrared Bands on TRMM/VIRS

The Visible and Infrared Scanner on the Tropical Rainfall Measuring Mission (TRMM/VIRS) is a whiskbroom imaging radiometer with two reflected solar bands and three emissive infrared bands. All five detectors are on a single cooled focal plane. This configuration necessitated the use of a paddlewheel scan mirror to avoid the effects of focal plane rotation that arise when using a scan mirror that is inclined to its axis of rotation. System radiometric requirements led to the need for protected silver as the mirror surface. Unfortunately, the SiO(x) coatings currently used to protect silver from oxidation introduce a change in reflectance with angle of incidence (AOI). This AOI dependence results in a modulation of system level response with scan angle. Measurement of system response vs. scan angle (RVS) was not difficult for the VIRS reflected solar bands, but attaining the required accuracy for the IR bands in the laboratory was not possible without a large vacuum chamber and a considerable amount of custom designed testing apparatus. Therefore, the decision was made to conduct the measurement on-orbit. On three separate occasions, the TRMM spacecraft was rotated about its pitch axis and, after the nadir view passed over the Earth's limb, the VIRS performed several thousand scans while viewing deep space. The resulting data has been analyzed and the RVS curves generated for the three IR bands are being used in the VIRS radiometric calibration algorithm. This, to our knowledge, the first time this measurement has been made on-orbit. Similar measurements are planned for the EOS-AM and EOS-PM MODIS sensors and are being considered for several systems under development. The VIRS on-orbit results will be compared to VIRS and MODIS system level laboratory measurements, MODIS scan mirror witness sample measurements and modeled data.

Barnes, William L.↗

Incident shock-wave characteristics in air, argon, carbon dioxide, and helium in a shock tube with unheated helium driver

Incident shock-wave velocities were measured in the Langley 6-inch expansion tube, operated as a shock tube, with air, argon, carbon dioxide, and helium as test gases. Unheated helium was used as the driver gas and most data were obtained at pressures of approximately 34 and 54 MN/sq m. A range of pressure ratio across the diaphragm was obtained by varying the quiescent test-gas pressure, for a given driver pressure, from 0.0276 to 34.5 kN/sq m. Single- and double-diaphragm modes of operation were employed and diaphragms of various materials tested. Shock velocity was determined from microwave interferometer measurements, response of pressure transducers positioned along interferometer measurements, response of pressure transducers positioned along the driven section (time-of-arrival gages), and to a lesser extent, measured tube-wall pressure. Velocities obtained from these methods are compared and limitations of the methods discussed. The present results are compared with theory and the effects of diaphragm mode (single or double diaphragm), diaphragm material, heating of the driver gas upon pressurization of the driver section, diaphragm opening time, interface mixing, and two-dimensional (nonplanar) flow are discussed.

Miller, C. G., III↗

Predicting System Response at Unmeasured Locations

Traditional techniques to derive dynamic specification for components have a great deal of uncertainty. One of the major sources of uncertainty is that the number of response measurements in the operational system environment is insufficient to determine the component motion. This inadequacy is due to logistical limitations for data recording in field testing and space limitations for accelerometers, strain gages and associated wiring. Available measurements are often some distance from the component and therefore do not represent component motion. Typical straight-line envelopes of these unrepresentative measurements guarantee an increase in the uncertainty. In this paper multiple methods are attempted to expand a sparse set of field test measurements on a system to responses of interest that cannot be measured in the field due to the limitations. Proof of concept is demonstrated on the Modal Analysis Test Vehicle (MATV). The responses of interest, known as “truth responses”, are measured in a system vibration environment along with an optimized sparse set of 30 field responses. Methods to expand the field responses to the truth responses are demonstrated by comparing the acceleration spectral density of the expanded response to the measured response. Two methods utilize a validated finite element model of the MATV. One is developed from purely experiment based frequency response functions of a laboratory pre-test. Finally, these approaches are designed to drastically reduce the uncertainty of the component in-service motion as a basis for developing specifications that are guaranteed to be conservative with a known (instead of unknown) conservatism.

42 ENGINEERING↗

Force Limiting Vibration Tests Evaluated from both Ground Acoustic Tests and FEM Simulations of a Flight Like Vehicle System Assembly

Marshall Space Flight Center has conducted a series of ground acoustic tests with the dual goals of informing analytical judgment, and validating analytical methods when estimating vibroacoustic responses of launch vehicle subsystems. The process of repeatedly correlating finite element-simulated responses with test-measured responses has assisted in the development of best practices for modeling and post-processing. In recent work, force transducers were integrated to measure interface forces at the base of avionics box equipment. Other force data was indirectly measured using strain gauges. The combination of these direct and indirect force measurements has been used to support and illustrate the advantages of implementing the Force Limiting approach for equipment qualification tests. The comparison of force response from integrated system level tests to measurements at the same locations during component level vibration tests provides an excellent illustration. A second comparison of the measured response cases from the system level acoustic tests to finite element simulations has also produced some principles for assessing the suitability of Finite Element Models (FEMs) for making vibroacoustics estimates. The results indicate that when FEM models are employed to guide force limiting choices, they should include sufficient detail to represent the apparent mass of the system in the frequency range of interest.

Smith, Andrew↗

Experimental observations of exploding bridgewire detonator function

Exploding bridgewire detonators are an industry standard technology used for over 75 years and valued for their precise timing and safety characteristics. Despite widespread use, their functional mechanism remains controversial with both shock and non-shock mechanisms attributed. In this work, we re-examine bridgewire detonator function with a suite of modern diagnostics and compare these observations with the existing literature. Traditional detonator observations consisted of voltage applied to the bridgewire and time dependent current, integral response measurements such as case motion and more recently Schlieren imaging of the detonator surface. In this work, we add visible light emission, X-ray transmission, proton radiography, and temperature measurements during detonator function in addition to voltage, current, and function times. The addition of in-situ observations of light emission, temperature, and density gives us new insight into the mechanisms of explosive bridgewire detonator function. We see a distinct separation in time, location, symmetry, and velocity of bridgewire output and detonation onset. During the time between bridgewire burst and the initiation of detonation, we observe a temperature ramp in the input pellet. In this paper, we present the suite of measurements and comparisons with the literature on integral response measurements.

42 ENGINEERING↗

A simulation study of test fixture attachment points for vibration test optimization (MEEN 5440 Final Project)

The aerospace industry uses vibration shaker tables to perform component durability testing. These dynamic environments tests often have a hard time replicating the service environment of a component due to a mismatch in the applied force or the boundary condition. Figure 1 shows the desired outcome of a dynamic environments test. The measured responses in a lab test, ideally, should match the measured response of the service environment field test. One way to address the mismatch between field environment and lab environment is with test fixture design. The test fixture attaches the component under test to the shaker table. Single-axis shakers are the industry standard type of shaker table, and, therefore, test fixtures are often rigid in order to minimize cross-axis responses.

42 ENGINEERING↗

Apparatuses and methods for testing electrochemical cells by measuring frequency response

Real-time battery impedance spectra are acquired by stimulating a battery or battery system with a signal generated as a sum of sine signals at related frequencies. An impedance measurement device can be used to interface between the battery system and a host computer for generating the signals. The impedance measurement device may be calibrated to adapt the response signal to more closely match other impedance measurement techniques. The impedance measurement device may be adapted to operate at mid-range voltages of about 50 volts and high-range voltages up to about 300 volts.

Christophersen, Jon P.↗

Evaluation of a Singular Value Decomposition Approach for Impact Dynamic Data Correlation

Impact dynamic tests are used in the automobile and aircraft industries to assess survivability of occupants during crash, to assert adequacy of the design, and to gain federal certification. Although there is no substitute for experimental tests, analytical models are often developed and used to study alternate test conditions, to conduct trade-off studies, and to improve designs. To validate results from analytical predictions, test and analysis results must be compared to determine the model adequacy. The mathematical approach evaluated in this paper decomposes observed time responses into dominant deformation shapes and their corresponding contribution to the measured response. To correlate results, orthogonality of test and analysis shapes is used as a criterion. Data from an impact test of a composite fuselage is used and compared to finite element predictions. In this example, the impact response was decomposed into multiple shapes but only two dominant shapes explained over 85% of the measured response

Horta, Lucas G.↗

Magnetic-Field-Response Measurement-Acquisition System

A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a response inflection. The "transmit-receive-compare" of sequential harmonics is repeated until the inflection is identified. The harmonic producing the amplitude inflection is the sensor resonant frequency. Resonant frequency and response amplitude are stored and then correlated to calibration data.

Woodward, Stanley E.↗

Study of fast response thermocouple measurement of temperatures in cryogenic gases

Thermocouples fabricated from uninsulated small diameter wire have fast reproducible response times. The thermocouple is thermally isolated from its supports by making the leads of sufficient length so that the heat conduction down the leads is small and assuming that the leads adjacent to the junction are subjected to the same thermal conditions.

Bielawski, T.↗

Status of warm fog dispersal research

A new concept for dispersing warm fog is presented. This brute force technique uses large volume recycled water sprays. Energy requirements for this technique are an order of magnitude less than those to operate a thermo-kinetic system. An important side benefit is the considerable emergency fire extinguishing capability it provides along the runway. Tests conducted to provide drop spectra measurements and temperature response measurements of suitable water sprays are described. Three mobile firefighting modules capable of spraying up to 630 l/s (10,000 gpm) to a height in excess of 50 m were utilized. Periodic operation of two parallel rows of nozzles in a heavy fog resulted in downwind-correlated increases in the visual range measured with a forward scatter visibility meter.

Keller, V. W.↗

New methods and results for quantification of lightning-aircraft electrodynamics

The NASA F-106 collected data on the rates of change of electromagnetic parameters on the aircraft surface during over 700 direct lightning strikes while penetrating thunderstorms at altitudes from 15,000 t0 40,000 ft (4,570 to 12,190 m). These in situ measurements provided the basis for the first statistical quantification of the lightning electromagnetic threat to aircraft appropriate for determining indirect lightning effects on aircraft. These data are used to update previous lightning criteria and standards developed over the years from ground-based measurements. The proposed standards will be the first which reflect actual aircraft responses measured at flight altitudes. Nonparametric maximum likelihood estimates of the distribution of the peak electromagnetic rates of change for consideration in the new standards are obtained based on peak recorder data for multiple-strike flights. The linear and nonlinear modeling techniques developed provide means to interpret and understand the direct-strike electromagnetic data acquired on the F-106. The reasonable results obtained with the models, compared with measured responses, provide increased confidence that the models may be credibly applied to other aircraft.

Pitts, Felix L.↗

Implementation of a modal filter on a five meter truss structure

Modal filtering is a spatial filtering technique which uses a weighted sum of a number of response measurements to extract the modal coordinates of the system from the physical response coordinates. No moving average or autoregressive calculations are required to implement the modal filter thus the modal coordinates may be calculated in real time. For practical implementation of the modal filter, the number and location of response locations must be chosen carefully. A modal filter is implemented on a five meter model space truss as a case study. The modal coordinates are extracted in real time using Hewlett Packard 3565 data acquisition and processig hardware. The effect of the number and location of response measurements on the performance of the modal filter is investigated. Applications of the modal filter to modal control and fast parameter identification are also discussed.

Shelly, S.↗