Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Capability Building Progression of an Insider Threat Mitigation Program at an International Nuclear Power Plant (Rev. 1)

With threats to nuclear facilities continuously evolving, the development and implementation of insider threat mitigation programs (ITMPs) are increasingly important. The Office of International Nuclear Security (INS) within the U.S. Department of Energy’s National Nuclear Security Administration (DOE/NNSA’s) developed Capability Building Progression of an Insider Threat Mitigation Program at an International Nuclear Power Plant to assist newcomers and existing nuclear power plant (NPP) operators in addressing insider threats and establishing effective response measures for insider activities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Perspective on Traditional and Data Driven Electrochemical Modeling and Analysis

To understand the behavior of electrochemical systems, we need to reduce the dimensionality of the measured current-voltage-time (I-V-t) data by fitting models, thus enabling us to analyze and compare the governing physics. Traditionally, the process for this is an 'expert first' approach: defining the model and its explicit assumptions based on inductive reasoning or empirical observation, fitting small portions of the I-V-t data where assumptions are most valid or carefully designing experiments to enforce key assumptions, and then interpreting the model parameters. However, modern data-driven methods enable a new paradigm: a 'data first' approach, where the latent behaviors governing the system's measured response are identified directly using machine-learning models that optimize both model structure and parameters from the I-V-t data, guaranteeing that the learned model explains as much of the observed system response as possible. After model identification, the model can then be interrogated by an expert to connect observed behaviors with underlying physics. This talk will review several different types of electrochemical analysis (electrochemical impedance, differential voltage-capacity, electrochemical kinetics) and compare the traditional and data-driven methods for analyzing the data.

42 ENGINEERING↗

Developing Source Term Database for Advanced Reactors

A source term database is crucial to informing nuclear emergency response measures, enabling emergency responders to assess the potential severity of nuclear and radiological consequences. In recent times, various advanced reactor designs have come into operation, are under construction, or are being designed and developed. This report documents an effort carried out to develop a source term database for advanced reactors. The report covers key design features of these reactors and discusses radioactivity buildup and source term inventories of dose-significant radionuclides in the reactor core. For neutronic and depletion analyses, we used the SCALE code system, a computational suite for reactor physics, depletion, criticality, and sensitivity/uncertainty quantification. We used SCALE/TRITON to perform depletion calculations to predict cycle length and discharge burnup and to generate the ORIGEN reactor library. Subsequently, we used SCALE/ORIGAMI to calculate radioactivity buildup and, thereby, the source term inventories at the targeted discharge burnup, using the ENDF/B-VII.1 nuclear data library. This report covers several advanced reactors, including the KLT-40S, RITM-200N, VOYGR, and eVinci. However, other reactors, such as the RITM-200S and ARC-100, have yet to be investigated and will be explored in future efforts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Extension of SCALE/Sampler’s sensitivity index for the assessment of cross section, fission yield, and decay data uncertainties

Accurate prediction of nuclide compositions and neutron and gamma sources and spectra for fresh and spent nuclear fuel through computational modeling and simulations is the basis for safeguards instruments design, optimization, and calibration, and for validation of the measured responses. The accuracy of these simulations can be significantly impacted by uncertainties in input parameters to the applied computer code. Input parameters are, for example, dimensions, material compositions, and temperatures of the model. Additionally, important but sometimes neglected input parameters for simulations of nuclear systems are the nuclear data that include nuclear reaction cross sections, fission product yields, and decay data. It has been shown that uncertainties of calculated results are dominated by uncertainties of these nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DisasterAWARE – A Global Alerting Platform for Flood Events

The rising number of flooding events combined with increased urbanization is contributing to significant economic losses due to damages to structures and infrastructures. From a risk reduction and resilience perspective, it is not only essential to forecast flood risk and potential impacts, but also to disseminate the information to stakeholders on the ground for rapid implementation of mitigation and response measures. This paper provides (i) an introduction to DisasterAWARE®, a global alerting system, that is used to disseminate flood risk information to stakeholders across the globe, and (ii) a discussion of the models implemented using earth observation data (Synthetic Aperture Radar and optical imagery) for near real-time assessment of flood severity and potential flood impacts to infrastructures. While the models are still in their nascent stage, a case study implementation of the models for the 2020 flooding event in Africa is presented to showcase the model integration with DisasterAWARE®.

54 ENVIRONMENTAL SCIENCES↗

CAPS PMssa Aerosol Extinction and SSA Data

We collected rapid (1 second time response) measurements of aerosol extinction and scattering (Mm-1) using an Aerodyne CAPS PMssa deployed during LASIC (as part of the LASIC SSA-constraint study) to measure ambient SSA at 530 nm wavelength to compare with other optical measurement methods. Measured from August 4 to September 22, 2017. Sampled from both PM1 and PM10 inlets. CAPS PMssa monitors have been tested extensively for PM2.5 and smaller particle sizes, but not for particles greater than 2,500 nm in diameter (i.e., PM10). The data were collected in order to provide an independent measurement of aerosol single scattering albedo at 530 nm wavelength to compare with ARM standard methods.

54 ENVIRONMENTAL SCIENCES↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Dynamic Assimilation Technique measures photosynthetic CO2 response curves with similar fidelity as steady-state approaches in half the time

The net CO2 assimilation (A) response to intercellular CO2 concentration (Ci) is a fundamental measurement in photosynthesis and plant physiology research. The conventional A/Ci protocols rely on steady-state measurements and take 15-40 minute per measurement, limiting data resolution or biological replication. Additionally, there are several CO2 protocols employed across the literature, without clear consensus as to the optimal protocol or systematic biases in their estimations. We compared the non-steady state Dynamic Assimilation Technique (DAT) protocol and the three most used CO2 protocols in steady-state measurements, and tested whether different CO2 protocols lead to systematic differences in estimations of the biochemical limitations to photosynthesis.

A/Ci response↗

High broadband photoconductivity of few-layered MoS 2 field-effect transistors measured using multi-terminal methods: effects of contact resistance

Among the layered two dimensional semiconductors, molybdenum disulfide (MoS 2 ) is considered to be an excellent candidate for applications in optoelectronics and integrated circuits due to its layer-dependent tunable bandgap in the visible region, high ON/OFF current ratio in field-effect transistors (FET) and strong light–matter interaction properties. In this study, using multi-terminal measurements, we report high broadband photocurrent response ( R ) and external quantum efficiency (EQE) of few-atomic layered MoS 2 phototransistors fabricated on a SiO 2 dielectric substrate and encapsulated with a thin transparent polymer film of Cytop. The photocurrent response was measured using a white light source as well as a monochromatic light of wavelength λ = 400 nm–900 nm. We measured responsivity using a 2-terminal configuration as high as R = 1 × 10 3 A W -1 under white light illumination with an optical power P opt = 0.02 nW. The R value increased to 3.5 × 10 3 A W -1 when measured using a 4-terminal configuration. Using monochromatic light on the same device, the measured values of R were 10 3 and 6 × 10 3 A W -1 under illumination of λ = 400 nm when measured using 2- and 4-terminal methods, respectively. The highest EQE values obtained using λ = 400 nm were 10 5 % and 10 6 % measured using 2- and 4-terminal configurations, respectively. The wavelength dependent responsivity decreased from 400 nm to the near-IR region at 900 nm. The observed photoresponse, photocurrent–dark current ratio (PDCR), detectivity as a function of applied gate voltage, optical power, contact resistances and wavelength were measured and are discussed in detail. The observed responsivity is also thoroughly studied as a function of contact resistance of the device.

36 MATERIALS SCIENCE↗

Fast response, optical radiance measurements of low intensity impurity emission in WEST plasmas with staggered wavelength filters

Fast response acquisition of atomic line emission through the use of a filterscope has been implemented on the WEST tokamak at multiple poloidal locations. Filterscopes consist of a fiber-optic-based transmission from the tokamak to specifically engineered optical bandpasses and photomultiplier tubes (PMT) that collect the emission intensity to measure a radiance, L [W/cm2/str], over the specified bandpass. This diagnostic records plasma-wall interaction (PWI) properties (e.g. impurity emission and recycling of main fuel ions) up to a max acquisition rate of 100 kHz. These PMT radiometric measurements are calibrated into a line-normalized radiance, LN [photons/sec/cm2/str], similar to traditional spectrometers, which can later be converted to a particle flux. Low intensity emission peaks are difficult to quantify due to often comparable continuum levels, thus a secondary filter shifted to a judiciously-selected, line-free region (~1 nm away) allows for background subtraction. The system currently installed on WEST targets tungsten (W) gross sputtering specifically by monitoring, with a filter pair, the spectral region near the neutral W line emission (W I 400.9 nm). The line and background filters of the pair are centered at 400.6 nm and 403.1 nm, respectively. Through a set beam splitters on each sight line, the filter pair are measuring from the same location. The two L signals near W I are then subtracted from each other yielding only the W I LN. W I LN data from a recent WEST experimental campaign is presented and compared with plasma parameters and traditional spectrometer measurements of W I line emission to demonstrate the capabilities of this staggered-filter filterscope method. Specifically, the choice of WEST-specific bandpass curves for the W I LN will be illustrated based on this latter comparison.

Neff, Anton↗

Measurement of the energy response of the ATLAS calorimeter to charged pions from $W^{\pm }\rightarrow \tau ^{\pm }(\rightarrow \pi ^{\pm }\nu _{\tau })\nu _{\tau }$ events in Run 2 data

The energy response of the ATLAS calorimeter is measured for single charged pions with transverse momentum in the range 10 < p T < 300 GeV. The measurement is performed using 139 fb –1 of LHC proton–proton collision data at √s = 13 TeV taken in Run 2 by the ATLAS detector. Charged pions originating from τ-lepton decays are used to provide a sample of high-p T isolated particles, where the composition is known, to test an energy regime that has not previously been probed by in situ single-particle measurements. The calorimeter response to single-pions is observed to be overestimated by ~2% across a large part of the p T spectrum in the central region and underestimated by ~4% in the endcaps in the ATLAS simulation. The uncertainties in the measurements are ≲1% for 15 < p T < 185 GeV in the central region. To investigate the source of the discrepancies, the width of the distribution of the ratio of calorimeter energy to track momentum, the energies per layer and response in the hadronic calorimeter are also compared between data and simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Neutron Multiplicity Counting Experiments to Optimal Cross-Section Adjustments

This paper presents the first application of model calibration to neutron multiplicity counting (NMC) experiments for cross-section optimization that is informed by adjoint-based sensitivity analysis (SA) and first-order uncertainty quantification (UQ). We summarize previous work on SA applied to NMC and describe notable modifications and additions. We give the procedure for first-order UQ and Bayesian-inference-based parameter estimation (PE). We then discuss model calibration applied to NMC of a 4.5-kg sphere of weapons-grade, alpha-phase plutonium metal (the BeRP ball) with the nPod neutron multiplicity counter. For the BeRP ball in bare and polyethylene-reflected configurations, we discuss the sensitivity of the first- and second-moment detector responses (i.e., first and second moments of the NMC distribution, respectively) to the cross sections. We describe the sources of uncertainty in the measured and simulated responses. Specifically, uncertainty in the measured responses is due to both random and systematic sources. Uncertainty in the simulated responses is due to the cross-section covariances. We describe in detail the adjustment to the cross sections and cross-section covariances due to the optimization. Due to the contribution of systematic uncertainties to the measured response uncertainties, the adjustment to the cross sections is similar in trend but larger in magnitude compared to that recommended by previous work. We compare the measured responses to responses simulated with nominal and optimized cross sections, demonstrating that the best-estimate cross sections produce simulations of NMC experiments that are more accurate with reduced uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG

Abstract Objective. Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject’s scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses. Approach. We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding. Main results. OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement. Significance. The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain–computer interfacing.

Iivanainen, Joonas (ORCID:0000000160344604)↗

COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils

The data release from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in 'D. Akimov et al 2022 JINST 17 P10034.' We share the data in the form of raw ADC waveforms, provide benchmark subselections and event reconstruction scripts to enhance the transparency and reproducibility of our results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring the dynamic response of the thylakoid architecture in plant leaves by electron microscopy

The performance of the photosynthesis machinery in plants, including light harvesting, electron transport, and protein repair is controlled by structural changes of the thylakoid membrane system inside the chloroplasts. In particular, the structure of the stacked grana area of thylakoid membranes is highly dynamic, changing in response to different environmental cues such as light intensity. For example, the aqueous thylakoid lumen enclosed by thylakoid membranes in grana has been documented to swell in the presence of light. However, light-induced alteration of the stromal gap in the stacked grana (partition gap) and of the unstacked stroma lamellae have not been well characterized. Light-induced changes of the entire thylakoid membrane system including the lumen in both stacked and unstacked domains as well as the partition gap are presented here, and the functional implications are discussed. This structural analysis was made possible by development of a robust semi-automated image analysis method combined with optimized plant tissue fixation techniques for transmission electron microscopy generating quantitative structural results for the analysis of thylakoid ultrastructure.

59 BASIC BIOLOGICAL SCIENCES↗

On the theoretical limitations in estimating thickness of a plate-like structure from a full-field single-tone response Lamb wave measurement

A persistent question in wavenumber analysis in the estimation of thickness from a steady-state wave field is identifying the theoretical sensitivity of the system. Here, a well-known trade-off between spatial frequency/wavenumber resolution and thickness resolution exists. The current work presents a calculation of the Cramer-Rao Lower bound (CRLB), specifically as applied to thickness estimates, for a 2-dimensional multi-mode waveform in Gaussian noise. Cases of near-field and far-field excitation are considered, and transducer position with respect to the scan area is also varied. Additionally, we consider the CRLB in a plate with multiple sources, simulated as sources placed on the boundary of the plate. We conclude by presenting the CRLB values in terms of frequency for various thicknesses, and by presenting optimal excitation frequencies for a nominal thickness, based on the CRLB.

47 OTHER INSTRUMENTATION↗