Search NASASearch

SEARCH · Search NASA

Results for “Microcomputers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Finite Element Composite Analysis Program (FECAP) for a microcomputer

A special purpose finite element composite analysis program for analyzing composite material behavior with a microcomputer is described. The formulation assumes a state of generalized plane strain in a material consisting of two or more orthotropic phases. Loading can be mechanical and/or thermal. The theoretical background, computer implementation, and program users guide are described in detail. A sample program is solved showing the required user input and computer generated output.

Bowles, David E.

Design and implementation of a microcomputer-based user interface controller for bursted data communications satellite ground terminals

The NASA Lewis Research Center is developing a laboratory-based satellite communications test bed for evaluation of state-of-the-art communications hardware and systems. Most of the digital components of the ground terminals are being constructed in-house at NASA Lewis. One of the ground terminal subsystems, the user interface controller, controls the connection and disconnection of all users to the communication network. The role of the user interface controller in the ground terminal is described and the design and implementation of the microcomputer-based subsystem is discussed.

Shalkhauser, Mary Jo W.

Development of a microcomputer based integrated design system for high altitude long endurance aircraft

A microcomputer-based integration of aircraft design disciplines has been applied theoretically to sailplane, microwave-powered aircraft, and High Altitude Long-Endurance (HALE) aircraft configurational definition efforts. Attention is presently given to the further development of such integrated-discipline approaches through the incorporation of AI techniques; these are then applied to the aforementioned case of the HALE. The windFrame language used, which is based on HyperTalk, will allow designers to write programs using a highly graphical, user interface-oriented environment.

Hall, David W.

A differential approach to microcomputer test battery development and implementation

The present microcomputer-based performance test battery emphasizes psychometric theory and utility for repeated-measures applications during extended exposure to various environmental stressors. In the menu that has been defined at the current state of this system's development, there are more than 30 'qualified' mental tests which stabilize in less than 10 min and possess test-retest reliabilities greater than 0.7 for a three-minute test/work period. The battery encompasses tests of cognition, information processing, psychomotor skill, memory, mood, etc. Several of the tests have demonstrated sensitivity to chemoradiotherapy, sleep loss, hypoxia, amphetamines, thermal stress, sensory deprivation, altitude, fatigue, and alcohol use. Recommendations are presented for 6-, 12-, and 22-min batteries.

Kennedy, R. S.

A microcomputer based frequency-domain processor for laser Doppler anemometry

A prototype multi-channel laser Doppler anemometry (LDA) processor was assembled using a wideband transient recorder and a microcomputer with an array processor for fast Fourier transform (FFT) computations. The prototype instrument was used to acquire, process, and record signals from a three-component wind tunnel LDA system subject to various conditions of noise and flow turbulence. The recorded data was used to evaluate the effectiveness of burst acceptance criteria, processing algorithms, and selection of processing parameters such as record length. The recorded signals were also used to obtain comparative estimates of signal-to-noise ratio between time-domain and frequency-domain signal detection schemes. These comparisons show that the FFT processing scheme allows accurate processing of signals for which the signal-to-noise ratio is 10 to 15 dB less than is practical using counter processors.

Horne, W. Clifton

Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

Kennedy, Robert S.

A menu of self-administered microcomputer-based neurotoxicology tests

This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests. Researchers developed this battery to be used to screen the fitness for duty of persons in at-risk occupations (astronauts, race car drivers), or those who may be exposed to environmental stress, toxic agents, or disease. The menu under study contained cognitive and motor tests implemented on a portable microcomputer including: a five-test core battery, lasting six minutes, which had demonstrable reliabilities and stability from several previous repeated-measures studies, and also 13 new tests, lasting 42 minutes, which had appeared in other batteries but had not yet been evaluated for repeated-measures implementation in this medium. Sixteen subjects self-administered the battery over 10 repeated sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the test from the core battery were comparable to those obtained previously under more controlled experimental conditions. Analyses of metric properties of the remaining 13 tests produced eight additional tests with satisfactory properties. Although the average retest reliability was high, cross-correlations between tests were low, indicating factorial richness. The menu can be used to form batteries of flexible total testing time which are likely to tap different mental processes and functions.

Kennedy, Robert S.

Differential effects of scopolamine and amphetamine on microcomputer-based performance tests

The effects of four weekly treatments with scopolamine (1.0 mg) and d-amphetamine (10 mg), separately or in combination, on human performance were investigated in 16 subjects undergoing nine performance tests from a menu of microcomputer-based tests administered after the treatment. It was d-amphetamine treatment that enhanced the results of motor and perceptual speed tests, while scopolamine had no effect on these tests. Two of the five cognitive tests showed reductions with scopolamine. The effects of scopolamine in this and other studies are considered in terms of a model which implies that the magnitude of the performance deficit depends on the performance type and the dosage level of the drug.

Kennedy, Robert S.

Position requirements for space station personnel and linkages to portable microcomputer performance assessment

The development and use of a menu of performance tests that can be self-administered on a portable microcomputer are investigated. In order to identify, develop, or otherwise select the relevant human capabilities/attributes to measure and hence include in the performance battery, it is essential that an analysis be conducted of the jobs or functions that will be performed throughout a space shuttle mission. The primary job analysis instrument, the Position Analysis Questionnaire (PAQ), is discussed in detail so the reader will have sufficient background for understanding the application of the instrument to the various work activities included within the scope of the study, and the derivation of the human requirements (abilities/attributes) from the PAQ analyses. The research methodology is described and includes the procedures used for gathering the PAQ data. The results are presented in detail with specific emphasis on identifying critical requirements that can be measured with a portable computerized assessment battery. A discussion of the results is given with implications for future research.

Jeanneret, P. R.

The NASA Langley Research Center 0.3-meter transonic cryogenic tunnel microcomputer controller source code

The 0.3 m Transonic Cryogenic Tunnel (TCT) microcomputer based controller has been operating for several thousand hours in a safe and efficient manner. A complete listing is provided of the source codes for the tunnel controller and tunnel simulator. Included also is a listing of all the variables used in these programs. Several changes made to the controller are described. These changes are to improve the controller ease of use and safety.

Kilgore, W. Allen

Microcomputer Intelligence for Technical Training (MITT): The evolution of an intelligent tutoring system

Microcomputer Intelligence for Technical Training (MITT) uses Intelligent Tutoring System (OTS) technology to deliver diagnostic training in a variety of complex technical domains. Over the past six years, MITT technology has been used to develop training systems for nuclear power plant diesel generator diagnosis, Space Shuttle fuel cell diagnosis, and message processing diagnosis for the Minuteman missile. Presented here is an overview of the MITT system, describing the evolution of the MITT software and the benefits of using the MITT system.

Norton, Jeffrey E.

Microcomputer based software for biodynamic simulation

This paper presents a description of a microcomputer based software package, called DYNAMAN, which has been developed to allow an analyst to simulate the dynamics of a system consisting of a number of mass segments linked by joints. One primary application is in predicting the motion of a human occupant in a vehicle under the influence of a variety of external forces, specially those generated during a crash event. Extensive use of a graphical user interface has been made to aid the user in setting up the input data for the simulation and in viewing the results from the simulation. Among its many applications, it has been successfully used in the prototype design of a moving seat that aids in occupant protection during a crash, by aircraft designers in evaluating occupant injury in airplane crashes, and by users in accident reconstruction for reconstructing the motion of the occupant and correlating the impacts with observed injuries.

Rangarajan, N.

Development of a microcomputer-based magnetic heading sensor

This paper explores the development of a flux-gate magnetic heading reference using a single-chip microcomputer to process heading information and to present it to the pilot in appropriate form. This instrument is intended to replace the conventional combination of mechanical compass and directional gyroscope currently in use in general aviation aircraft, at appreciable savings in cost and reduction in maintenance. Design of the sensing element, the signal processing electronics, and the computer algorithms which calculate the magnetic heading of the aircraft from the magnetometer data have been integrated in such a way as to minimize hardware requirements and simplify calibration procedures. Damping and deviation errors are avoided by the inherent design of the device, and a technique for compensating for northerly-turning-error is described.

Garner, H. D.

Microcomputer Software

MicroRim, Inc.'s Microrim is a deviation of a database developed under NASA funding and used by NASA to store data required for analyzing the heat shield tiles on the Space Shuttle Orbiter. As a management system for microcomputers, it offers mainframe sophistication and allows for sorting, storing and data retrieval for various applications. The program is convertible, and easily utilized by nontechnical personnel. RIM (Relational Information Management) is currently used for structural analysis and design data management, etc. by a variety of businesses and universities.

Source record

The Use of a Microcomputer Based Array Processor for Real Time Laser Velocimeter Data Processing

The application of an array processor to laser velocimeter data processing is presented. The hardware is described along with the method of parallel programming required by the array processor. A portion of the data processing program is described in detail. The increase in computational speed of a microcomputer equipped with an array processor is illustrated by comparative testing with a minicomputer.

Meyers, James F.

Development of microcomputer-based mental acuity tests

Recent disasters have focused attention on performance problems due to the use of alcohol and controlled substances in the workplace. Environmental stressors such as thermal extremes, mixed gases, noise, motion, and vibration also have adverse effects on human performance and operator efficiency. However, the lack of a standardized, sensitive, human performance assessment battery has probably delayed the systematic study of the deleterious effects of various toxic chemicals and drugs at home and in the workplace. The collective goal of the research reported here is the development of a menu of tests embedded in a coherent package of hardware and software that may be useful in repeated-measures studies of a broad range of agents that can degrade human performance. A menu of 40 tests from the Automated Performance Test System (APTS) is described, and the series of interlocking studies supporting its development is reviewed. The APTS tests, which run on several versions of laptop portables and desktop personal computers, have been shown to be stable, reliable, and factorially rich, and to have predictive validities with holistic measures of intelligence and simulator performances. In addition, sensitivity studies have been conducted in which performance changes due to stressors, agents, and treatments were demonstrated. We believe that tests like those described here have prospective use as an adjunct to urine testing for the screening for performance loss of individuals who are granted access to workplaces and stations that impact public safety.

Non-NASA Center

Stand-alone development system using a KIM-1 microcomputer module

A small microprocessor-based system designed to: contain all or most of the interface hardware, designed to be easy to access and modify the hardware, to be capable of being strapped to the seat of a small general aviation aircraft, and to be independent of the aircraft power system is described. The system is used to develop a low cost Loran C sensor processor, but is designed such that the Loran interface boards may be removed and other hardware interfaces inserted into the same connectors. This flexibility is achieved through memory-mapping techniques into the microprocessor.

Nickum, J. D.