Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microwave spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Attenuation and phase dispersion in the atmosphere due to the microwave spectrum of oxygen

Radio wave propagation in the 40- to 140-GHz band through the earth's atmosphere is strongly influenced by the behavior of the O2 microwave spectrum. This behavior causes the transfer function to depend critically upon altitude. The spectroscopic properties of O2 are discussed and reduced to engineering formulas expressing attenuation and phase dispersion rates in terms of frequency and meteorological parameters. The theory is supported on several accounts by reliable spectroscopic measurements. Pressure scanning spectroscopy is used to investigate the O2 microwave spectrum under simulated atmospheric conditions. The application of spectroscopic information to analytical treatments of transfer properties for inhomogeneous slant paths is demonstrated. Attenuation and phase dispersion between 49 and 72 GHz are evaluated for zenith and tangential paths.

Liebe, H. J.↗

Remote sensing of atmospheric chemistry; Proceedings of the Meeting, Orlando, FL, Apr. 1-3, 1991

The present volume on remote sensing of atmospheric chemistry discusses special remote sensing space observations and field experiments to study chemical change in the atmosphere, network monitoring for detection of stratospheric chemical change, stratospheric chemistry studies, and the combining of model, in situ, and remote sensing in atmospheric chemistry. Attention is given to the measurement of tropospheric carbon monoxide using gas filter radiometers, long-path differential absorption measurements of tropospheric molecules, air quality monitoring with the differential optical absorption spectrometer, and a characterization of tropospheric methane through space-based remote sensing. Topics addressed include microwave limb sounder experiments for UARS and EOS, an overview of the spectroscopy of the atmosphere using an FIR emission experiment, the detection of stratospheric ozone trends by ground-based microwave observations, and a FIR Fabry-Perot spectrometer for OH measurements.

Mcelroy, James L.↗

The microwave and far-infrared spectra of the O-(18)H radical

Far-infrared laser magnetic resonance (LMR) spectroscopy was used to calculate the frequencies, wavelengths, and line strengths for transitions of O-(18)H molecules at microwave and far-infrared frequencies. In this experiment, a molecular transition frequency is tuned into coincidence with that of a fixed frequency laser by the application of a variable magnetic field. The O-(18)H radicals, detected in natural abundance (0.20 percent), were produced by the reaction of hydrogen atoms with nitrogen dioxide. These data together with microwave frequencies ascertained by Gottlieb, Redford, and Smith (1974) were used to determine the parameters of an effective Hamiltonian. Rotational levels up to J = 5.5 were involved. Results are indicated schematically and the low-lying energy levels of O-(18)H are shown. It is concluded that the frequencies of transitions between levels studied directly in the LMR experiment are reliable.

Comben, E. R.↗

Microwave digestion preparation and ICP determination of boron in human plasma

A microwave digestion procedure, followed by Inductively Coupled Argon Plasma Spectroscopy, is described for the determination of boron (B) in human plasma. The National Institute of Standards and Technology (NIST) currently does not certify the concentration of B in any substance. The NIST citrus leaves 1572 (CL) Standard Reference Material (SRM) and wheat flour 1567a (WF) were chosen to determine the efficacy of digestion. CL and WF values compare favorably to those obtained from an open-vessel, wet digestion followed by ICP, and by neutron activation and mass spectrometric measurements. Plasma samples were oxidized by doubled-distilled ultrapure HNO3 in 120 mL PFA Teflon vessels. An MDS-81D microwave digestion procedure allows for rapid and relatively precise determination of B in human plasma, while limiting handling hazards and sources of contamination.

Ferrando, A. A.↗

Hard x ray/microwave spectroscopy of solar flares

The joint study of hard x ray and microwave observations of solar flares is extremely important because the two complementary ways of viewing the accelerated electrons yield information that cannot be obtained using hard x rays or microwaves alone. The microwaves can provide spatial information lacking in the hard x rays, and the x ray data can give information on the energy distribution of electrons that remove ambiguities in the radio data. A prerequisite for combining the two data-sets, however, is to first understand which range of microwave frequencies correlate best with the hard x rays. This SMM Guest Investigator grant enabled us to combine multi-frequency OVRO data with calibrated hard x ray data to shed light on the relationship between the two emissions. In particular, the questions of which microwave frequencies correspond to which hard x ray energies, and what is the corresponding energy of the electrons that produce both types of emission are investigated.

Gary, Dale E.↗

Atomic physics

Atomic research on metastable atoms, resonance spectroscopy, and collision phenomena

NUCLEAR PHYSICS↗

Diagnostic for Plasma Enhanced Chemical Vapor Deposition and Etch Systems

In order to meet NASA's requirements for the rapid development and validation of future generation electronic devices as well as associated materials and processes, enabling technologies ion the processing of semiconductor materials arising from understanding etch chemistries are being developed through a research collaboration between Stanford University and NASA-Ames Research Center, Although a great deal of laboratory-scale research has been performed on many of materials processing plasmas, little is known about the gas-phase and surface chemical reactions that are critical in many etch and deposition processes, and how these reactions are influenced by the variation in operating conditions. In addition, many plasma-based processes suffer from stability and reliability problems leading to a compromise in performance and a potentially increased cost for the semiconductor manufacturing industry. Such a lack of understanding has hindered the development of process models that can aid in the scaling and improvement of plasma etch and deposition systems. The research described involves the study of plasmas used in semiconductor processes. An inductively coupled plasma (ICP) source in place of the standard upper electrode assembly of the Gaseous Electronics Conference (GEC) radio-frequency (RF) Reference Cell is used to investigate the discharge characteristics and chemistries. This ICP source generates plasmas with higher electron densities (approximately 10(exp 12)/cu cm) and lower operating pressures (approximately 7 mTorr) than obtainable with the original parallel-plate version of the GEC Cell. This expanded operating regime is more relevant to new generations of industrial plasma systems being used by the microelectronics industry. The motivation for this study is to develop an understanding of the physical phenomena involved in plasma processing and to measure much needed fundamental parameters, such as gas-phase and surface reaction rates. species concentration, temperature, ion energy distribution, and electron number density. A wide variety of diagnostic techniques are under development through this consortium grant to measure these parameters. including molecular beam mass spectrometry (MBMS). Fourier transform infrared (FTIR) spectroscopy, broadband ultraviolet (UV) absorption spectroscopy, a compensated Langmuir probe. Additional diagnostics. Such as microwave interferometry and microwave absorption for measurements of plasma density and radical concentrations are also planned.

Cappelli, Mark A.↗

Monolithic Isolated Single-Mode Ring Laser

MISER uses four-sided ring to lase nonreciprocally. Laser concept provides very-compact, efficient, and stable source of coherent radiation. Lasers of single, very-stable frequency desirable for number of purposes. Frequency stability makes possible coherent detection of laser radiation with low-bandwidth detector, useful for communications. Allows very-high-resolution spectroscopy. Any application where desired to use laser in way microwaves used traditionally enhanced if frequency very stable.

Kane, T. J.↗

Electron cyclotron resonance deposition of a-Si:H and a-C:H films

Amorphous silicon (a-Si:H) and amorphous carbon (a-C:H) films have been deposited by electron cyclotron resonance (ECR) microwave plasma enhanced CVD. A high deposition rate of 25 A/sec and a light-to-dark conductivity ratio of 500,000 for a-Si:H films have been achieved by the ECR process using a pure silane plasma. ECR microwave plasmas have been analyzed by in situ optical emission spectroscopy (OES) and have shown a strong H-asterisk emission at 434 nm indicating higher chemical reactivity than RF plasmas. The linear correlation between the film deposition rate and the SiH-asterisk emission intensity of ECR silane plasma suggests that SiH-asterisk species are related to the neutral radicals which are responsible for the a-Si:H film deposition. Hard and soft a-C:H films have been deposited by ECR with and without RF bias power, respectively. The RF bias to the substrate is found to play a critical role in determining the film structure and the carbon bonding configuration of ECR deposited a-C:H films. Raman spectra of these films indicate that ECR deposition conditions can be optimized to produce diamond films.

Shing, Y. H.↗

A microwave plasma cleaning apparatus

In a microwave electron cyclotron resonance plasma source, reactive plasmas of oxygen and its mixtures of argon have been used for evaluating plasma cleaning technologies. Small aluminum samples (0.95 x 1.9 cm) were coated with thin films (less than or equal to 20 micrometers in thickness) of Shell Vitrea oil and cleaned with reactive plasmas. The discharge parameters, such as gas pressure, magnetic field, substrate biasing, and microwave power, were varied to change cleaning conditions. A mass spectroscopy (or residual gas analyzer) was used to monitor the status of plasma cleaning. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured cleaning rates of low-pressure (0.5-m torr) argon/oxygen plasmas were as high as 2.7 micrometers/min. X-ray photoelectron spectroscopy was used to determine cleanliness of the sample surfaces. In this paper, significant results of the plasma cleaning are reported and discussed.

Tsai, C. C.↗

Nonradiative activity across the H-R diagram - Which types of stars are solar-like?

Advances in the understanding of nonradiatively heated outer atmospheric layers (coronae, transition regions, and chromospheres) and other solar-like activity in stars are noted. Ultraviolet spectroscopy from IUE, X-ray imaging from the Einstein Observatory, microwave detections by the VLA, and new optical observing techniques have made such advances possible. Classes of star that can be considered 'solar-like' are noted, where a solar-like star is defined as one which has a turbulent magnetic field sufficiently strong to control the dynamics and energetics in its outer atmospheric regions.

Linsky, J. L.↗

Comparison of Columnar Water Vapor Measurements During The Fall 1997 ARM Intensive Observation Period: Optical Methods

In the fall of 1997 the Atmospheric Radiation Measurement (ARM program conducted an intensive Observation Period (IOP) to study water vapor at its Southern Great Plains (SGP) site. Among the large number of instruments, four sun-tracking radiometers were present to measure the columnar water vapor (CWV). All four solar radiometers retrieve CWV by measuring solar transmittance in the 0.94-micrometer water vapor absorption band. As one of the steps in the CWV retrievals the aerosol component is subtracted from the total transmittance, in the 0.94-micrometer band. The aerosol optical depth comparisons among the same four radiometers are presented elsewhere. We have used three different methods to retrieve CWV. Without attempting to standardize on the same radiative transfer model and its underlying water vapor spectroscopy we found the CWV to agree within 0.13 cm (rms) for CWV values ranging from 1 to 5 cm. Preliminary results obtained when using the same updated radiative transfer model with updated spectroscopy for all instruments will also be shown. Comparisons to the microwave radiometer results will be included in the comparisons.

Schmid, Beat↗

Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum

This software processes the flyby spectra of the Chirp Transform Spectrometer (CTS) of the Microwave Instrument for Rosetta Orbiter (MIRO). The tool corrects the effect of Doppler shift and local-oscillator (LO) frequency shift during the flyby mode of MIRO operations. The frequency correction for CTS flyby spectra is performed and is integrated with multiple spectra into a high signal-to-noise averaged spectrum at the rest-frame RF frequency. This innovation also generates the 8 molecular line spectra by dividing continuous 4,096-channel CTS spectra. The 8 line spectra can then be readily used for scientific investigations. A spectral line that is at its rest frequency in the frame of the Earth or an asteroid will be observed with a time-varying Doppler shift as seen by MIRO. The frequency shift is toward the higher RF frequencies on approach, and toward lower RF frequencies on departure. The magnitude of the shift depends on the flyby velocity. The result of time-varying Doppler shift is that of an observed spectral line will be seen to move from channel to channel in the CTS spectrometer. The direction (higher or lower frequency) in the spectrometer depends on the spectral line frequency under consideration. In order to analyze the flyby spectra, two steps are required. First, individual spectra must be corrected for the Doppler shift so that individual spectra can be superimposed at the same rest frequency for integration purposes. Second, a correction needs to be applied to the CTS spectra to account for the LO frequency shifts that are applied to asteroid mode.

Lee, Seungwon↗