Search NASA⌕ Search

SEARCH · Search NASA

Results for “Miniaturization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluation of survival estimates generated from tracking downstream migrating juvenile sea lamprey ( Petromyzon marinus ) with a miniature acoustic telemetry tag

Fish that undertake juvenile migration pass through habitats that vary in mortality risk. The ability to identify regions of persistently low survival would improve fishery management. We conducted a field study combined with predictive modeling of survival in downstream migrating juvenile sea lamprey using a new micro-acoustic telemetry tag designed for implantation into small, slender-bodied fishes. Detection data were collected from eight receivers placed across a coastal riverine–wetland–lake complex. Juvenile sea lamprey initiated downstream movement near nautical twilight, stopped frequently, and were more likely to move during high river discharge. Estimated survival was highest in the riverine reach, declined through the river–wetland complex, and dropped precipitously in the drowned rivermouth lake. However, the high transmission rate and resulting short battery life of the microtransmitters (as configured) likely resulted in missed detections in the lower reaches. Simulation analyses suggested survival estimation could be improved by increasing the number of tagged lamprey and staggering release locations. We offer practical recommendations for the use of this new transmitter in field studies with small anguilliform fish.

59 BASIC BIOLOGICAL SCIENCES↗

A Miniaturized Long-Life, Low-Frequency Acoustic Transmitter for Fish Tracking in Marine Environment - CRADA 447

Advance state-of-art technologies for tracking marine mammals, fish, sea turtles, and other protected species, based on acoustic telemetry. Objectives include: (1) develop a new acoustic transmitter that has a greatly improved detection range and service life while being significantly smaller and lighter than the existing commercial counterparts; and (2) reach a TRL of 5 so the technology is ready for organizations interested in small- or medium-scale field trials.

42 ENGINEERING↗

Miniaturized Hybrid Materials Inspired by Nature (Final Technical Report)

The objective of our research program is to develop a fundamental scientific understanding of assembly in biomolecular materials mediated by mechanisms that mimic complex events in the cellular environment. The building blocks that we study include globular, disordered, and filamentous proteins, lipids, and nucleic acids. Notably, the nanoscale assemblies may either be similar to, or highly distinct from, those occurring in vivo, owing to the complex nature of the systems. Novel assemblies may further result due to controlled shape changes in building blocks.

36 MATERIALS SCIENCE↗

AMMT FY23 HFIR Irradiation Test Matrix – Supported by the Design of a Miniature Bend Bar Irradiation Vehicle

With the continued advancement of additive manufacturing (AM) techniques, interest has grown in the development and qualification of steels produced via these methods for use in the structural components of advanced nuclear reactors. Therefore, it is crucial that the properties of these materials such as the tensile strength and fracture toughness be investigated following neutron irradiation to support their use in industry. To that end, a test plan to irradiate several tensile and bend bar specimens in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory was proposed, along with the development of a new “MINBEN” capsule design that features MBS-1 bend bar specimens that have a larger cross-sectional area than those of previous designs, which allows for higher temperature out-of-pile testing. The specimens include AM 316H stainless steel with wrought 316H and A709 stainless steels for reference, and they will be irradiated at 2 dpa and 10 dpa—corresponding to roughly 1 and 5 cycles at the HFIR midplane—at temperatures of 400°C and 600°C. The MINBEN design was found to be capable of providing specimen test plane average temperatures in the range of 220–660°C for six specimens, with a min-max spread in this temperature of ~40°C and a 95% confidence interval of ~24°C. This analysis shows that the capsule provides an effective vehicle for gathering needed high-temperature fracture toughness data.

36 MATERIALS SCIENCE↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Studying Corrosion Using Miniaturized Particle Attached Working Electrodes and the Nafion Membrane

We developed a new approach to attach particles onto a conductive layer as a working electrode (WE) in a microfluidic electrochemical cell with three electrodes. Nafion, an efficient proton transfer molecule, is used to form a thin protection layer to secure particle electrodes. Spin coating is used to develop a thin and even layer of Nafion membrane. The effects of Nafion (5 wt% 20 wt%) and spinning rates were evaluated using multiple sets of replicates. The electrochemical performance of various devices was demonstrated. Additionally, the electrochemical performance of the devices is used to select and optimize fabrication conditions. The results show that a higher spinning rate and a lower Nafion concentration (5 wt%) induce a better performance, using cerium oxide (CeO2) particles as a testing model. The WE surfaces were characterized using atomic force microscopy (AFM), scanning electron microscopy-focused ion beam (SEM-FIB), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and X-ray photoelectron spectroscopy (XPS). The comparison between the pristine and corroded WE surfaces shows that Nafion is redistributed after potential is applied. Our results verify that Nafion membrane offers a reliable means to secure particles onto electrodes. Furthermore, the electrochemical performance is reliable and reproducible. Thus, this approach provides a new way to study more complex and challenging particles, such as uranium oxide, in the future.

42 ENGINEERING↗

A High Gain Lens-Coupled On-Chip Antenna Module for Miniature-Sized Millimeter-Wave Wireless Transceivers

This paper presents high gain and compact Transmit/Receive (TX/RX) integrated antennas in a standard BiCMOS 130nm technology for millimeter-scale millimeter-wave (mm-wave) applications, including high data rate radios and high resolution radars. The proposed TX/RX antenna module utilizes an integrated dipole antenna for the receiver and a slot antenna for the transmitter, placed orthogonally. The achieved gain and radiation efficiency are 5.7dBi and 41.3% for the slot antenna, respectively, and 6dBi and 39% for the dipole antenna. The link budget is improved by 16dB by optimization on the geometry aswell as application of a high resistivity hemispheric silicon dielectric lens.

Engineering↗