At least 91 records · Page 5

The use of designed experiments in the process development of continuous propellant mixing

A continuous mix pilot plant was constructed at Aerojet Propulsion Division in Sacramento, California to develop a robust propellant mixing process for the full scale plant that was to be built at the NASA Advanced Solid Rocket Motor facility Yellow Creek, Mississippi. The plant was used to conduct dozens of subsystem and full system mixing tests for evaluation of equipment, processing methods, and control schemes for later use at the production plant. As a culmination to this work, a series of designed experiments were conducted using an eight run Taguchi analysis with four factors at two levels each to determine the primary effect of processing parameters on propellant ballistic and mechanical properties. The factors examined in these runs included the propellant production rate (454 (1000) and 622 kg/hr (1371 Ib/hr)), the product temperature out of the mixer (49 (120) and 63 deg C (145 deg F)), mixer screw speed (75 and 90 rpm), and the deaerator excess capacity (20 and 80 percent). Measured response variables included the uncured and cured density, Crawford Bomb liquid strand burning rates, and selected mechanical properties. The experiment revealed that several of the response variables displayed significant changes from run-to-run with the product temperature being the single most important factor. After concluding this experiment, a twenty-six hour confirmation run was conducted to verify the conclusions reached in the designed experiment. The extended run produced over 12,250 kgs (27,000 lbs) of propellant meeting all of the pre-run targeted properties including density (1.803 g/cc (0.065 lb/in(exp 3)) with a 0.12 percent coefficient of variation (CV) at 25 deg C (77 deg F)), liquid strand burn rate (0.889 cm/s (0.350 in/s) with a 0.69 percent CV at 4210 KPa (610 psig), 15.6 deg C (60 deg F)), nominal maximum stress (828 KPa (120 psig) with a 2.84 percent CV, S&E at 25 deg C (77 deg F), 5.08 cm/min (2 in/min)), strain at nominal maximum (47.4 percent with a 3.96 percent CV), and initial tangent modulus (5349 KPa (775 psig) with a 7.26 percent CV).

Campbell, J. A.↗

A Meshless Method Using Radial Basis Functions for Beam Bending Problems

A meshless local Petrov-Galerkin (MLPG) method that uses radial basis functions (RBFs) as trial functions in the study of Euler-Bernoulli beam problems is presented. RBFs, rather than generalized moving least squares (GMLS) interpolations, are used to develop the trial functions. This choice yields a computationally simpler method as fewer matrix inversions and multiplications are required than when GMLS interpolations are used. Test functions are chosen as simple weight functions as they are in the conventional MLPG method. Compactly and noncompactly supported RBFs are considered. Noncompactly supported cubic RBFs are found to be preferable. Patch tests, mixed boundary value problems, and problems with complex loading conditions are considered. Results obtained from the radial basis MLPG method are either of comparable or better accuracy than those obtained when using the conventional MLPG method.

Raju, I. S.↗

The bovine tuberculosis burden in cattle herds in zones with low dose radiation pollution in the Ukraine

The authors describe a study of the tuberculosis (TB) incidence in cattle exposed to low doses of radiation resulting from the Chernobyl (pronounced ‘Chornobyl’ in Ukrainian) nuclear plant catastrophe in 1986. The purpose of the study was to determine if ionising radiation influences the number of outbreaks of bovine TB and their severity on farms in the Kyiv, Cherkasy and Chernigiv regions of the Ukraine. These farms are all located within a 200 km radius of Chernobyl and have had low-dose radiation pollution. Pathological and blood samples were taken from cattle in those regions that had positive TB skin tests. Mycobacterium spp. were isolated, differentiated by PCR, analysed and tested in guinea pigs and rabbits. Species differentiation showed a significant percentage of atypical mycobacteria, which resulted in the allergic reactions to tuberculin antigen in the skin test. Mixed infection of M. bovis and M. avium subsp. hominissuis was found in three cases. The results concluded that low-dose radiation plays a major role in the occurrence of bovine TB in regions affected by the Chernobyl nuclear disaster.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Scaling Relationships Based on Scaled Tank Mixing and Transfer Test Results

This report documents the statistical analyses performed (by Pacific Northwest National Laboratory for Washington River Protection Solutions) on data from 26 tests conducted using two scaled tanks (43 and 120 inches) in the Small Scale Mixing Demonstration platform. The 26 tests varied several test parameters, including mixer-jet nozzle velocity, base simulant, supernatant viscosity, and capture velocity. For each test, samples were taken pre-transfer and during five batch transfers. The samples were analyzed for the concentrations (lbs/gal slurry) of four primary components in the base simulants (gibbsite, stainless steel, sand, and ZrO 2 ). The statistical analyses including modeling the component concentrations as functions of test parameters using stepwise regression with two different model forms. The resulting models were used in an equivalent performance approach to calculate values of scaling exponents (for a simple geometric scaling relationship) as functions of the parameters in the component concentration models. The resulting models and scaling exponents are displayed in tables and graphically. The sensitivities of component concentrations and scaling exponents to the test parameters are presented graphically. These results will serve as inputs to subsequent work by other researchers to develop scaling relationships that are applicable to full-scale tanks.

Equivalent Performance↗

Scaling Relationships Based on Scaled Tank Mixing and Transfer Test Results

This report documents the statistical analyses performed (by Pacific Northwest National Laboratory for Washington River Protection Solutions) on data from 26 tests conducted using two scaled tanks (43 and 120 inches) in the Small Scale Mixing Demonstration platform. The 26 tests varied several test parameters, including mixer-jet nozzle velocity, base simulant, supernatant viscosity, and capture velocity. For each test, samples were taken pre-transfer and during five batch transfers. The samples were analyzed for the concentrations (lbs/gal slurry) of four primary components in the base simulants (gibbsite, stainless steel, sand, and ZrO2). The statistical analyses including modeling the component concentrations as functions of test parameters using stepwise regression with two different model forms. The resulting models were used in an equivalent performance approach to calculate values of scaling exponents (for a simple geometric scaling relationship) as functions of the parameters in the component concentration models. The resulting models and scaling exponents are displayed in tables and graphically. The sensitivities of component concentrations and scaling exponents to the test parameters are presented graphically. These results will serve as inputs to subsequent work by other researchers to develop scaling relationships that are applicable to full-scale tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The mixed-mode bending method for delamination testing

A mixed-mode bending (MMB) test procedure is presented which combines double cantilever beam mode-I loading and end-notch flexure mode II loading on a split, unidirectional laminate. The MMB test has been analyzed by FEM and by beam theory in order to ascertain the mode I and mode II components' respective strain energy release rates, G(I) and G(II); these analyses indicate that a wide range of G(I)/G(II) ratios can be generated by varying the applied load's position on the loading lever. The MMB specimen analysis and test procedures are demonstrated for the case of AS4/PEEK unidirectional laminates.

Reeder, James R.↗

RCRA Part A and Part B Permit Application for Waste Management Activities at the Nevada Test Site: Proposed Mixed Waste Disposal Unit (MWSU)

The proposed Mixed Waste Storage Unit (MWSU) will be located within the Area 5 Radioactive Waste Management Complex (RWMC). Existing facilities at the RWMC will be used to store low-level mixed waste (LLMW). Storage is required to accommodate offsite-generated LLMW shipped to the Nevada Test Site (NTS) for disposal in the new Mixed Waste Disposal Unit (MWDU) currently in the design/build stage. LLMW generated at the NTS (onsite) is currently stored on the Transuranic (TRU) Pad (TP) in Area 5 under a Mutual Consent Agreement (MCA) with the Nevada Division of Environmental Protection, Bureau of Federal Facilities (NDEP/BFF). When the proposed MWSU is permitted, the U.S. Department of Energy (DOE) will ask that NDEP revoke the MCA and onsite-generated LLMW will fall under the MWSU permit terms and conditions. The unit will also store polychlorinated biphenyl (PCB) waste and friable and non-friable asbestos waste that meets the acceptance criteria in the Waste Analysis Plan (Exhibit 2) for disposal in the MWDU. In addition to Resource Conservation and Recovery Act (RCRA) requirements, the proposed MWSU will also be subject to Department of Energy (DOE) orders and other applicable state and federal regulations. Table 1 provides the metric conversion factors used in this application. Table 2 provides a list of existing permits. Table 3 lists operational RCRA units at the NTS and their respective regulatory status.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A One System Integrated Approach to Simulant Selection for Hanford High Level Waste Mixing and Sampling Tests - 13342

The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capabilities using simulated Hanford High-Level Waste (HLW) formulations. This represents one of the largest remaining technical issues with the high-level waste treatment mission at Hanford. Previous testing has focused on very specific TOC or WTP test objectives and consequently the simulants were narrowly focused on those test needs. A key attribute in the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2 is to ensure testing is performed with a simulant that represents the broad spectrum of Hanford waste. The One System Integrated Project Team is a new joint TOC and WTP organization intended to ensure technical integration of specific TOC and WTP systems and testing. A new approach to simulant definition has been mutually developed that will meet both TOC and WTP test objectives for the delivery and receipt of HLW. The process used to identify critical simulant characteristics, incorporate lessons learned from previous testing, and identify specific simulant targets that ensure TOC and WTP testing addresses the broad spectrum of Hanford waste characteristics that are important to mixing, sampling, and transfer performance are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A One System Integrated Approach to Simulant Selection for Hanford High Level Waste Mixing and Sampling Tests

The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capabilities using simulated Hanford High-Level Waste (HLW) formulations. This represents one of the largest remaining technical issues with the high-level waste treatment mission at Hanford. Previous testing has focused on very specific TOC or WTP test objectives and consequently the simulants were narrowly focused on those test needs. A key attribute in the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2 is to ensure testing is performed with a simulant that represents the broad spectrum of Hanford waste. The One System Integrated Project Team is a new joint TOC and WTP organization intended to ensure technical integration of specific TOC and WTP systems and testing. A new approach to simulant definition has been mutually developed that will meet both TOC and WTP test objectives for the delivery and receipt of HLW. The process used to identify critical simulant characteristics, incorporate lessons learned from previous testing, and identify specific simulant targets that ensure TOC and WTP testing addresses the broad spectrum of Hanford waste characteristics that are important to mixing, sampling, and transfer performance are described.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of distortion data from TF30-P-3 mixed compression inlet test

A program was conducted to reduce and analyze inlet and engine data obtained during testing of a TF30-P-3 engine operating behind a mixed compression inlet. Previously developed distortion analysis techniques were applied to the data to assist in the development of a new distortion methodology. Instantaneous distortion techniques were refined as part of the distortion methodology development. A technique for estimating maximum levels of instantaneous distortion from steady state and average turbulence data was also developed as part of the program.

King, R. W.↗

Redesign of the mixed-mode bending delamination test to reduce nonlinear effects

The mixed-mode bending (MMB) test uses a lever to apply simultaneously mode I and mode II loading to a split-beam specimen. An iterative analysis that accounts for the geometric nonlinearity of the MMB test was developed. The analysis accurately predicted the measured load-displacement response and the strain energy release rate, G, of an MMB test specimen made of AS4/PEEK. The errors in G when calculated using linear theory were found to be as large as 30 percent in some cases. Because it would be inconvenient to use a nonlinear analysis to analyze MMB data, the MMB apparatus was redesigned to minimize the nonlinearity. With the improved apparatus, loads are applied just above the midplane of the test specimen through a roller attached to the lever. This apparatus was demonstrated by measuring the mixed-mode delamination fracture toughhess of the test specimen. The nonlinearity errors associated with testing this tough composite material were less than +/- 3 percent. The data from the improved MMB apparatus analyzed with a linear analysis were similar to those found with the original apparatus and the nonlinear analysis.

Reeder, James R.↗

Tests of a mixed compression axisymmetric inlet with large transonic mass flow at Mach numbers 0.6 to 2.65

A 38.8-cm (15.28-in.) capture diameter model of a mixed-compression axisymmetric inlet system with a translating cowl was designed and tested. The internal contours, designed for Mach number 2.65, provided a throat area of 59 percent of the capture area when the cowl was retracted for transonic operation. Other model features included a boundary-layer removal system, vortex generators, an engine airflow bypass system, cowl support struts, and rotating rakes at the engine face. All tunnel testing was conducted at a tunnel total pressure of about 1 atm (a unit Reynolds number of about 8.53 million/m at Mach number 2.65) at angles of attack from 0 deg to 4 deg. Results for the following were obtained: total-pressure recovery and distortion at the engine face as a function of bleed mass-flow ratio, the effect of bleed and vortex generator configurations on pressure recovery and distortion, inlet tolerance to unstart due to changes in angle of attack or Mach number, surface pressure distributions, boundary-layer profiles, and transonic additive drag. At Mach number 2.65 and with the best bleed configurations, maximum total pressure recovery at the engine face ranged from 91 to 94.5 percent with bleed mass-flow ratios from 4 to 9 percent, respectively, and total-pressure distortion was less than 10 percent. At off-design supersonic Mach numbers above 1.70, maximum total-pressure recoveries and corresponding bleed mass flows were about the same as at Mach number 2.65, with about 10 to 15 percent distortion. In the transonic Mach number range, total pressure recovery was high (above 96 percent) and distortion was low (less than 15 percent) only when the inlet mass-flow ration was reduced 0.02 to 0.06 from the maximum theoretical value (0.590 at Mach number 1.0).

Smeltzer, D. B.↗

Modifications to JLab 12 GeV Refrigerator and Wide Range Mix Mode Performance Testing Results

Analysis of data obtained during the spring 2013 commissioning of the new 4.5-K refrigeration system at Jefferson Lab (JLab) for the 12 GeV upgrade indicated a wide capacity range with good efficiency and minimal operator interaction. Testing also showed that the refrigerator required a higher liquid nitrogen (LN) consumption for its pre-cooler than anticipated by the design. This does not affect the capacity of the refrigerator, but it does result in an increased LN utility cost. During the summer of 2015 the modifications were implemented by the cold box manufacturer, according to a design similar to the JLab 12 GeV cold box specification. Subsequently, JLab recommissioned the cold box and performed extensive performance testing, ranging from 20% to 100% of the maximum capacity, and in various modes of operation, ranging from pure refrigeration, pure liquefaction, half-and-half mix mode and at selected design modes. This testing demonstrated the modifications resulted in a LN consumption significantly lower than the expected design for the nominal and maximum capacity modes and equal to the expected design for the pure refrigeration mode (which is the most demanding). The testing also demonstrated that the refrigerator system has a good and fairly constant performance over this wide capacity range and different modes of operation. Also, a pulsed-load test, similar to what is expected for cryogenic systems supporting fusion experiments, was conducted to observe the response using the Floating Pressure ? Ganni Cycle, which was stable and robust. This paper will discuss the results and analysis of this testing pertaining to the LN consumption, the system efficiency over a wide range of capacity and different modes and the behavior of the system to a pulsed load.

Knudsen, P.↗

Methods for Quantifying the Uncertainties of LSIT Test Parameters, Test Results, and Full-Scale Mixing Performance Using Models Developed from Scaled Test Data

This report discusses the statistical methods for quantifying uncertainties in 1) test responses and other parameters in the Large Scale Integrated Testing (LSIT), and 2) estimates of coefficients and predictions of mixing performance from models that relate test responses to test parameters. Testing at a larger scale has been committed to by Bechtel National, Inc. and the U.S. Department of Energy (DOE) to “address uncertainties and increase confidence in the projected, full-scale mixing performance and operations” in the Waste Treatment and Immobilization Plant (WTP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-Situ Testing Methods for Mixed-Mode Harsh Environments

Future NASA missions are driving a need for instrumentation and space electronics that will operate at extreme temperatures, with low mass and extended deployments. This need results in devices that will experience dose damage at both low and high temperatures that will suppress annealing and induce accelerated wear out issues. Therefore, the ability to perform radiation tests on devices at temperature is critical. This paper analyses the methods and process to enable these test as developed at the JPL Dynamitron Facility. Since electronics are the radiation source for this facility, the steps to ensure parity with cobalt-60 testing are discussed. Also discussed are the implications for system level testing and mixed radiation mode testing for highly integrated and scaled devices.

Scheick, Leif Z↗

Field Testing of a Mixed Potential IoT Sensor Platform for Methane Quantification

Emissions of CH 4 from natural gas infrastructure must urgently be addressed to mitigate its effect on global climate. With hundreds of thousands of miles of pipeline in the US used to transport natural gas, current methods of surveying for leaks are inadequate. Mixed potential sensors are a low cost, field deployable technology for remote and continuous monitoring of natural gas infrastructure. We demonstrate for the first time a field trial of a mixed potential sensor device coupled with machine learning and internet-of-things platform at Colorado State University’s Methane Emissions Technology Evaluation Center (METEC). Emissions were detected from a simulated buried underground pipeline source. Sensor data was acquired and transmitted from the field test site to a remote cloud server. Quantification of concentration as a function of vertical distance is consistent with previously reported transport modelling efforts and experimental surveys of methane emissions by more sophisticated CH 4 analyzers.

03 NATURAL GAS↗

Design and Test of Mixed-flow Impellers III : Design and Experimental Results for Impeller Model MFI-2A and Comparison with Impeller Model MFI-1A

A mixed-flow impeller was designed to give a prescribed blade-surface velocity distribution at mean blade height for a given hub-shroud profile. The blade shape at mean blade height, which was produced by the prescribed velocity distribution, was extended by means of radial lines to form the composite blade shape from hub to shroud. The resulting blade was relatively thick; therefore, it was necessary to retain the inverse blade taper which resulted from extension of the radial lines in order to prevent merging or near merging of the separate blades near the hub. For the first test version of the impeller, designated the MFI-2A, the blade height was arbitrarily made greater than that for the basic impeller (the MFI-2) to allow for viscous effects. At design equivalent speed of 1400 feet per second the peak pressure ratio and maximum adiabatic efficiency were 3.95 and 79 percent, respectively. The adiabatic efficiency of the MFI-2A is four points lower than that for impeller model MFI-1A, but because of the higher slip factor for the MFI-2A, the pressure ratios are approximately equal. The procedures followed in the design of the MFI-1A and MFI-2A were, in general, the same; and, although the prescribed initial condition resulted in geometrical configurations that were quite dissimilar, the resulting performance characteristics compare favorably with designs for which considerable development work has been necessary.

COMPRESSION AND COMPRESSORS↗