Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mobile detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Developing Fieldable Systems for Chemical Sensing Using Field Asymmetric Ion Mobility Spectrometry and Mass Spectrometry

Currently, there is an urgent need for field-rugged and field-programmable sensor systems that provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. These devices must be portable, low cost, robust, and provide accurate measurements to avoid both false positive and negative results. Furthermore, the information provided by the devices must be received in a timely manner so that informed decisions can be immediately made and the appropriate actions taken. Two technologies that are unparalleled in their sensitivity, selectivity, and trace-level detection capabilities are field asymmetric ion mobility spectrometry (FAIMS) and mass spectrometry. Here, we will show progress that has been made toward developing fieldable FAIMS systems and mass spectrometers. Working in collaboration with Sionex Corporation, the microDMx detector was equipped with a continuous air sampling system to develop selective methods for the analysis of compounds of interest. A microdiaphragm pump (KNF Neuberger, Inc.) is used to pull in gas-phase analytes directly from the air for separation and detection with the FAIMS system. The FAIMS evaluation platform (SVAC) unit currently measures 9.8-inch x 4.6-inch x 3.2-inch, weighs 3.1 lb, and utilizes a {sup 63}Ni source to ionize incoming compounds. Analytes entering the unit are separated and identified by their characteristic response to the compensation voltage (V{sub c}) at a given rf field strength (V{sub rf}). This response has been observed to be unique for a wide range of substances studied. If additional verification were required or a targeted analyte present in a complex chemical matrix, a FAIMS unit equipped with a fast gas chromatography column has been evaluated. The unit combines the separation capabilities of gas chromatography with the selectivity of FAIMS. It measures 9.5-inch x 5.25-inch x 3.5-inch, weighs 3.8 lb, and uses a 10.6 eV photoionization source. Analytes are identified both by their elution time from the column and by the characteristic response in the FAIMS spectrum. Analysis times required to obtain results for most analytes examined are less than three minutes. A fieldable mass spectrometer system is also being developed that includes sampling, ionization, mass selection and detection, vacuum technology, and analytical methodology with remote data transmission. Multiple methods for mass selection are being explored, including both Penning and Paul type ion traps as well as a quadrupole system to determine which is best suited for a portable mass spectrometer. Several ionization sources and ion counting methods will also be evaluated to establish their effectiveness with each system. The intended result of this project is a handheld mass spectrometer system capable of field deployment for the detection and identification of a wide range of gas-phase CBE species.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Demonstration of Intelligent Container Surveillance Using Stationary and Mobile Camera Platforms

Surveillance of nuclear material storage containers is required to ensure that the container safety boundary is maintained during the service life of the container. As many of these container types are the first and only containment barrier to release protecting the worker, public, and environment, it is imperative to develop robust surveillance tools to characterize container degradation. Machine learning (ML) techniques have matured quickly in the past decade and are slowly becoming a routine application in data analysis. While more popular architectures have been developed with different applications in mind, these can be easily translated to container surveillance requirements. In this study, we developed a ML model based on the Detectron2 framework to identify slip lid containers and common exterior container defects, primarily dents. Commercial-off-the-shelf cameras are combined into a stationary camera array or are mounted to a robotic arm to provide more mobility for positioning needs. Results from the model evaluations on the images indicate that the stationary camera arrays outperform the accuracy of the mobile camera systems for both individual camera and composite image detections. Overall, however, the detection accuracies of the systems fell short of 50% and were less than satisfactory. Future efforts to improve the system involve focusing on a single camera deployable solution that combines a controllable light source that eliminates one of the biggest environmental factors that influence ML model detection performance. Additional training set collection is planned to build a more robust model that enables accurate detection from a wider range of imaging conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Dual-Sided Coded-Aperture Radiation Detection System , Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment

We report the development of a large-area, mobile, coded-aperture radiation imaging system for localizing compact radioactive sources in three dimensions while rejecting distributed background. The 3D Stand-Off Radiation Detection System (SORDS-3D) has been tested at speeds up to 95 km/h and has detected and located sources in the millicurie range at distances of over 100 m. Radiation data are imaged to a geospatially mapped world grid with a nominal 1.25- to 2.5-m pixel pitch at distances out to 120 m on either side of the platform. Source elevation is also extracted. Imaged radiation alarms are superimposed on a side-facing video log that can be played back for direct localization of sources in buildings in urban environments. The system utilizes a 37-element array of 5 x 5 x 50 cm{sup 3} cesium-iodide (sodium) detectors. Scintillation light is collected by a pair of photomultiplier tubes placed at either end of each detector, with the detectors achieving an energy resolution of 6.15% FWHM (662 keV) and a position resolution along their length of 5 cm FWHM. The imaging system generates a dual-sided two-dimensional image allowing users to efficiently survey a large area. Imaged radiation data and raw spectra are forwarded to the RadioNuclide Analysis Kit (RNAK), developed by our collaborators, for isotope ID. An intuitive real-time display aids users in performing searches. Detector calibration is dynamically maintained by monitoring the potassium-40 peak and digitally adjusting individual detector gains. We have recently realized improvements, both in isotope identification and in distinguishing compact sources from background, through the installation of optimal-filter reconstruction kernels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FedADMP: A Joint Anomaly Detection and Mobility Prediction Framework via Federated Learning

With the proliferation of mobile devices and smart cameras, detecting anomalies and predicting their mobility are critical for enhancing safety in ubiquitous computing systems. Due to data privacy regulations and limited communication bandwidth, it is infeasible to collect, transmit, and store all data from mobile devices at a central location. To overcome this challenge, we propose FedADMP, a federated learning based joint Anomaly Detection and Mobility Prediction framework. FedADMP adaptively splits the training process between the server and clients to reduce computation loads on clients. To protect the privacy of user data, clients in FedADMP upload only intermediate model parameters to the cloud server. We also develop a differential privacy method to prevent the cloud server and external attackers from inferring private information during the model upload procedure. Extensive experiments using real-world datasets show that FedADMP consistently outperforms existing methods.

97 MATHEMATICS AND COMPUTING↗

Monitoring/Verification using DMS: TATP Example

Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations-management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a “smart dust” sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the illegal use of explosives or chemical and biological materials. DMS is currently one of the foremost emerging technologies for field separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. Fast GC is the leading field analytical method for gas phase separation of chemical species in complex mixtures. Low-thermal-mass GC columns have led to compact, low-power field systems capable of complete analyses in 15–300 seconds. A collaborative effort optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for peroxide-based explosive measurements.

47 OTHER INSTRUMENTATION↗

CO2 DIAL measurements of water vapor

CO2 lidars have heretofore been used to measure water vapor concentrations primarily using the 10R(20) line at 10.247 microns, which has a strong overlap with a water vapor absorption line. This paper discusses the use of that line as well as other CO2 laser lines for which the absorption coefficients are weaker. The literature on measurement of water vapor absorption coefficients using CO2 lasers is reviewed, and the results from four laboratories are shown to be generally consistent with each other after they are normalized to the same partial pressure, temperature, and ethylene absorption coefficent for the 10P(14) CO2 laser line; however, the agreement with the Air Force Geophysics Laboratory's HITRAN and FASCOD 2 spectral data tapes is not good either for the water vapor absorption lines or for the water vapor continuum. Demonstration measurements of atmospheric water vapor have been conducted using the Mobile Atmospheric Pollutant Mapping System, a dual CO2 lidar system using heterodyne detection. Results are discussed for measurements using three sets of laser line pairs covering a wide range of water vapor partial pressures.

Grant, William B.↗

Improving Sensorimotor Adaptation Following Long Duration Space Flight by Enhancing Vestibular Information Transfer

Crewmember adapted to the microgravity state may need to egress the vehicle within a few minutes for safety and operational reasons after gravitational transitions. The transition from one sensorimotor state to another consists of two main mechanisms: strategic and plastic-adaptive and have been demonstrated in astronauts returning after long duration space flight. Strategic modifications represent "early adaptation" - immediate and transitory changes in control that are employed to deal with short-term changes in the environment. If these modifications are prolonged then plastic-adaptive changes are evoked that modify central nervous system function, automating new behavioral responses. More importantly, this longer term adaptive recovery mechanism was significantly associated with their strategic ability to recover on the first day after return to Earth G. We are developing a method based on stochastic resonance to enhance information transfer by improving the brain's ability to detect vestibular signals (Vestibular Stochastic Resonance, VSR) especially when combined with balance training exercises such as sensorimotor adaptability (SA) training for rapid improvement in functional skill, for standing and mobility. This countermeasure to improve detection of vestibular signals is a stimulus delivery system that is wearable/portable providing low imperceptible levels of white noise based binaural bipolar electrical stimulation of the vestibular system (stochastic vestibular stimulation). To determine efficacy of vestibular stimulation on physiological and perceptual responses during otolith-canal conflicts and dynamic perturbations we have conducted a series of studies: We have shown that imperceptible binaural bipolar electrical stimulation of the vestibular system across the mastoids enhances balance performance in the mediolateral (ML) plane while standing on an unstable surface. We have followed up on the previous study showing VSR stimulation improved balance performance in both ML and anteroposterior planes while stimulating in the ML axis only. We have shown the efficacy of VSR stimulations on enhancing physiological and perceptual responses of whole-body orientation during low frequency perturbations (0.1 Hz) on the ocular motor system using a variable radius centrifuge on both physiological (using eye movements) and perceptual responses (using a joystick) to track imposed oscillations. The variable radius centrifuge provides a selective tilting sensation that is detectable only by the otolith organs providing conflicting information from the canal organs of the vestibular system (intra-vestibular conflict). These results indicate that VSR can improve performance in sensory conflict scenarios like that experienced during space flight. We have showed the efficacy of VSR stimulation to improve balance and locomotor control on subjects exposed to continuous, sinusoidal lateral motion of the support surface while walking on a treadmill while viewing perceptually matched linear optic flow. We have shown the safety of short term continuous use of up to 4 hours of VSR stimulation and its efficacy in improving balance and locomotor function in Parkinson's Disease patients. This technique for improving vestibular signal detection may thus provide additional information to improve strategic abilities. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increased utilization of vestibular information and therefore serve to optimize and personalize the SA countermeasure prescription. This forms the basis of its usefulness both as a training modality and further help in significantly reducing the number of days required to recover functional performance to preflight levels after long duration space flight.

Mulavara, A. P.↗

Distributed Sensing Node Configuration

A vision and radar sensor integration strategy for surveillance of Advance Air Mobility Mission concept of airspace is contained in the CAD drawing in this publication developed as part of NASA's Transformational Tools and Technology project. High-density airspace operations with multiple aircraft type and potentially noncooperative aircraft require distributed sensor detection and tracking systems to monitor airspace for safe, autonomous flight operations for advanced air mobility, urban air mobility, and high density small uncrewed air systems (SUAS) flight concepts. Contained herein are drawings that are available in the stp and creo file formats of the distributed sensing nodes. Additional dovetail integration is included to enable rapid changing of embedded system. A day in the life node deployment is included in the 2023_last_flight_day.mp4. Please cite this publication if you use these drawings. This sensor configuration methodology is presented in detail in the publication reference below. Chester Dolph, Thomas Lombaerts, Corey A. Ippolito, Vahram Stepanyan, Evan Kawamura, Keerthana Kannan, George Szatkowski, Todd Ferante, Christopher Morris, Federica Vitiello, Flavia Causa, Roberto Opromolla and Giancarmine Fasano. "Distributed Sensor Fusion of Ground and Air Nodes using Vision and Radar Modalities for Tracking Multirotor Small Uncrewed Air Systems and Birds," AIAA 2024-1781. AIAA SCITECH 2024 Forum. January 2024.

Chester V Dolph↗

Cross-Vendor and Cross-State Analysis of GPS Probe Data Latency

Crowd sourced GPS probe data have become a major source of real-time traffic information applications. In addition to traditional traveler advisory systems such as dynamic message signs (DMS) and 511 systems, probe data are being used for automatic incident detection, integrated corridor management (ICM), end of queue warning systems, and mobility-related smartphone applications. Several private sector vendors offer minute by minute network-wide travel time and speed probe data. The quality of such data in terms of deviation of the reported travel time and speeds from ground-truth has been extensively studied in recent years, and as a result concerns over the accuracy of probe data have mostly faded away. However, the latency of probe data - defined as the lag between the time at which disturbance in traffic speed is reported in the outsourced data feed, and the time at which the traffic is perturbed - has become a subject of interest. The extent of latency of probe data for real-time applications is critical, so it is important to have a good understanding of the amount of latency and its influencing factors. This paper uses high-quality independent Bluetooth/Wi-Fi re-identification data collected on multiple freeway segments in three different states, to measure the latency of the vehicle probe data provided by three major vendors. The statistical distribution of the latency and its sensitivity to speed slowdown and recovery periods are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

IMPULSE Highlights for recent experiments at the Advanced Photon Source (2/9-2/18 2014)

This report is a presentation, with slides noting, Over 40 experiments were completed during this run using X-ray imaging on the IMPULSE system at Sector 32 IDB; Summary of new experiments: Idealized sphere compaction – Capture progression of dynamic densification through an idealized system on 0.500 mm borosilicate glass spheres (Slide 1); Detonator and EBW Imaging Experiments on IMPULSE – First time HE was intentionally detonated at APS (Slide 2); Spall and high strain rate crack nucleation/propagation in PMMA – PCI data is providing new and unique insights for model validation (Slide 3); Fiber composite for armor applications was studied under ballistic impact of Dyneema (Collaboration with Army Research Laboratory) (Slide 4). Summary of on-going experiments; Crack propagation in vitreous carbon – observed crack motion and caustic; Jet formation experiments on large grain cerium to examine phase dependent strength; Ballistic impact of Comp-B and TNT to examine thermo-mechanical response in-situ with various penetrator geometries to vary shear concentration. Other efforts: IMPULSE system moved and installed in Sector 35 (DCS). This includes the 4-frame X-ray detection system, 4- channel PDV, and other gun diagnostics; New remotely operated mobile IMPULSE structure in fabrication – to be delivered to APS in April; 4 Mini-VISAR Systems and 4-channel PDV installed in DCS instrumentation room with all associated diagnostics.

36 MATERIALS SCIENCE↗

Chemical contamination remote sensing

A ground mobile laser test bed system was assembled to assess the feasibility of detection of various types of chemical contamination using Differential Scattering (DISC) and Differential Absorption (DIAL) Lidar techniques. Field experiments with the test bed system using chemical simulants were performed. Topographic reflection and range resolved DIAL detection of vapors as well as DISC detection of aerosols and surface contamination were achieved. Review of detection principles, design of the test bed system, and results of the experiments are discussed.

Carrico, J. P.↗

Utilization of Local Law Enforcement Aerial Resources in Consequence Management (CM) Response

During the past decade the U.S. Department of Homeland Security (DHS) was instrumental in enhancing the nation’s ability to detect and prevent a radiological or nuclear attack in the highest risk cities. Under the DHS Securing the Cities initiative, nearly 13,000 personnel in the New York City region have been trained in preventive radiological and nuclear detection operations, and nearly 8,500 pieces of radiological detection equipment have been funded. As part of the preventive radiological/nuclear detection (PRND) mission, several cities have received funding to purchase commercial aerial radiation detection systems. In 2008, the U.S. Department of Energy, National Nuclear Security Administration Aerial Measuring System (AMS) program started providing Mobile Aerial Radiological Surveillance (MARS) training to such assets, resulting in over 150 HAZMAT teams’ officers and pilots from 10 law enforcement organizations and fire departments being trained in the aerial radiation detection. From the beginning, the MARS training course covered both the PRND and consequence management (CM) missions. Even if the law enforcement main focus is PRND, their aerial assets can be utilized in the collection of initial radiation data for post-event radiological CM response. Based on over 50 years of AMS operational experience and information collected during MARS training, this presentation will focus on the concepts of CM response using aerial assets as well as utilizing law enforcement/fire department aerial assets in CM. Also discussed will be the need for establishing closer relationships between local jurisdictions’ aerial radiation detection capabilities and state and local radiation control program directors, radiological health department managers, etc. During radiological events these individuals may become primary experts/advisers to Incident Commanders for radiological emergency response, especially in the early stages of a response. The knowledge of the existence, specific capabilities, and use of local aerial radiation detection systems would be critical in planning the response, even before federal assets arrive on the scene. The relationship between local and federal aerial assets and the potential role for the further use of the MARS training and expanded AMS Reachback capabilities in facilitating such interactions will be discussed.

consequence management, CM, local law enforcement,↗

DS-CDMA satellite diversity reception for personal satellite communication: Downlink performance analysis

The downlink of a satellite-mobile personal communication system employing power-controlled Direct Sequence Code Division Multiple Access (DS-CDMA) and exploiting satellite-diversity is analyzed and its performance compared with a more traditional communication system utilizing single satellite reception. The analytical model developed has been thoroughly validated by means of extensive Monte Carlo computer simulations. It is shown how the capacity gain provided by diversity reception shrinks considerably in the presence of increasing traffic or in the case of light shadowing conditions. Moreover, the quantitative results tend to indicate that to combat system capacity reduction due to intra-system interference, no more than two satellites shall be active over the same region. To achieve higher system capacity, differently from terrestrial cellular systems, Multi-User Detection (MUD) techniques are likely to be required in the mobile user terminal, thus considerably increasing its complexity.

DeGaudenzi, Riccardo↗

Zero Trust Strategies for Chemical, Biological, Radiological, and Nuclear Detection Systems: D.1 Cyber Scenarios

The evolving landscape of cybersecurity necessitates a paradigm shift to a Zero Trust (ZT) model, which assumes breaches and continuously verifies trust. This approach reshapes how trust boundaries are established, focusing on identities, devices, networks, applications, and data, rather than solely relying on perimeter defenses such as firewalls. Central to this transformation is the National Institute of Standards and Technology's (NIST) Special Publication 800-207, outlining the Zero Trust Architecture (ZTA), along with Executive Order 14028, which mandates federal agencies to adopt ZT principles. Complementary to these efforts, the Cybersecurity and Infrastructure Security Agency (CISA) developed the Zero Trust Maturity Model (ZTMM), providing a framework with five pillars and three cross-cutting capabilities to guide agencies toward enhanced cybersecurity maturity. In support of these initiatives, the DHS Countering Weapons of Mass Destruction Office (CWMD) is applying ZT principles to secure Chemical, Biological, Radiological, and Nuclear (CBRN) detection systems. Recognizing the diverse deployment models and network connectivity of these systems—from stationary, non-networked units to mobile, cloud-connected devices—the Pacific Northwest National Laboratory (PNNL) is developing cybersecurity scenarios specifically for CBRN environments. These scenarios examine various configurations and technological capabilities, offering insights into the application of ZTMM pillars in enhancing the security postures of CBRN devices. The cybersecurity scenarios presented by PNNL are hypothetical, crafted to explore theoretical situations and stimulate discussion on the potential use or compromise of CBRN detection systems in varied contexts. These narratives are illustrative and do not reference any real events or actual networks. Instead, they employ generalized reference models to highlight concepts and potential issues within CBRN security, focusing on how Zero Trust strategies can be adapted to address these challenges effectively.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Physical Protection Systems Test Bed for International Counter-Trafficking System Development

Physical protection systems have a widespread impact on the nuclear industry in areas such as nuclear safeguards, arms control, and trafficking of illicit goods (e.g., nuclear materials) across international borders around the world. Many challenges must be overcome in design and deployment of foreign border security systems such as lack of infrastructure, extreme environmental conditions, limited knowledge of terrain, insider threats, and occasional cultural resistance. Successful security systems, whether it be a system designed to secure a single facility or a whole border security system, rely on the entire integrated system composed of multiple subsystems. This test bed is composed of many unique sensors and subsystems, including wireless unattended ground sensors, a buried fiber-optic acoustic sensor, a lossy coaxial distributed sensor, wireless links, pan-tilt-zoom cameras, mobile power generation systems, unmanned aerial vehicles, and fiber-optic-fence intrusion detection systems. A Common Operating Picture software architecture is utilized to integrate a number of these subsystems. We are currently performance testing each system for border security and perimeter security applications by examining metrics such as probability of sense and a qualitative understanding of the sensor s vulnerability of defeat. The testing process includes different soil conditions for buried sensors (e.g., dry, wet, and frozen) and an array of different tests including walking, running, stealth detection, and vehicle detection. Also, long term sustainability of systems is tested including performance differences due to seasonal variations (e.g. summer versus winter, while raining, in foggy conditions). The capabilities of the test bed are discussed. Performance testing results, both at the individual component level and integrated into a larger system for a specific deployment (in situ), help illustrate the usefulness and need for integrated testing facilities to carry out this mission. The test bed provides access to grassy fields, wooded areas, and a large waterway three distinct testing environments. The infrastructure supporting deployment of systems at the test bed includes grid power, renewable power systems, climate controlled enclosures, high bandwidth wireless links, and a fiber optic communications backbone. With over 10 acres of dedicated area and direct waterway access, the test bed is well suited for long term test and evaluation of physical protection and security systems targeting a wide range of applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Test Bed Doppler Wind Lidar and Intercomparison Facility At NASA Langley Research Center

State of the art 2-micron lasers and other lidar components under development by NASA are being demonstrated and validated in a mobile test bed Doppler wind lidar. A lidar intercomparison facility has been developed to ensure parallel alignment of up to 4 Doppler lidar systems while measuring wind. Investigations of the new components; their operation in a complete system; systematic and random errors; the hybrid (joint coherent and direct detection) approach to global wind measurement; and atmospheric wind behavior are planned. Future uses of the VALIDAR (VALIDation LIDAR) mobile lidar may include comparison with the data from an airborne Doppler wind lidar in preparation for validation by the airborne system of an earth orbiting Doppler wind lidar sensor.

Kavaya, Michael J.↗

Test Bed Doppler Wind Lidar and Intercomparison Facility At NASA Langley Research Center

State of the art 2-micron lasers and other lidar components under development by NASA are being demonstrated and validated in a mobile test bed Doppler wind lidar. A lidar intercomparison facility has been developed to ensure parallel alignment of up to 4 Doppler lidar systems while measuring wind. Investigations of the new components; their operation in a complete system; systematic and random errors; the hybrid (joint coherent and direct detection) approach to global wind measurement; and atmospheric wind behavior are planned. Future uses of the VALIDAR (VALIDation LIDAR) mobile lidar may include comparison with the data from an airborne Doppler wind lidar in preparation for validation by the airborne system of an earth orbiting Doppler wind lidar sensor.

Kavaya, Michael J.↗