Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motor Activity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effect of environmental enrichment devices on behaviors of single- and group-housed squirrel monkeys (Saimiri sciureus)

Squirrel monkeys display an interest in novel places, habituate to new situations, and spend most of their daily activity in the wild in large groups engaging in feeding behaviors over a broad area. Captivity limits these behaviors and consequently may disrupt normal social organizations. In captivity, squirrel monkeys may exhibit stereotypical behaviors that are believed to indicate decreased psychologic well-being. When a monkey's behavior can be made to approach that seen in the wild, and stereotypical behaviors are minimal, it is assumed that psychologic well-being is adequate. Environmental enrichment devices have been used to address the Animal Welfare Act requirement that psychologic well-being of captive nonhuman primates be considered. The purpose of the study reported here was to examine whether various environmental enrichment devices improve the psychologic well-being of captive squirrel monkeys. In the study, we used behavioral observation to quantify the effectiveness of several environmental enrichment devices for reducing stereotypical behaviors in squirrel monkeys housed alone or in groups. Analysis of our results revealed that the environmental enrichment devices did not affect the expression of normal or stereotypical behaviors, but that the type of housing did.

NASA Discipline Neuroscience↗

Evidence for increased cardiac compliance during exposure to simulated microgravity

We measured hemodynamic responses during 4 days of head-down tilt (HDT) and during graded lower body negative pressure (LBNP) in invasively instrumented rhesus monkeys to test the hypotheses that exposure to simulated microgravity increases cardiac compliance and that decreased stroke volume, cardiac output, and orthostatic tolerance are associated with reduced left ventricular peak dP/dt. Six monkeys underwent two 4-day (96 h) experimental conditions separated by 9 days of ambulatory activities in a crossover counterbalance design: 1) continuous exposure to 10 degrees HDT and 2) approximately 12-14 h per day of 80 degrees head-up tilt and 10-12 h supine (control condition). Each animal underwent measurements of central venous pressure (CVP), left ventricular and aortic pressures, stroke volume, esophageal pressure (EsP), plasma volume, alpha1- and beta1-adrenergic responsiveness, and tolerance to LBNP. HDT induced a hypovolemic and hypoadrenergic state with reduced LBNP tolerance compared with the control condition. Decreased LBNP tolerance with HDT was associated with reduced stroke volume, cardiac output, and peak dP/dt. Compared with the control condition, a 34% reduction in CVP (P = 0.010) and no change in left ventricular end-diastolic area during HDT was associated with increased ventricular compliance (P = 0.0053). Increased cardiac compliance could not be explained by reduced intrathoracic pressure since EsP was unaltered by HDT. Our data provide the first direct evidence that increased cardiac compliance was associated with headward fluid shifts similar to those induced by exposure to spaceflight and that reduced orthostatic tolerance was associated with lower cardiac contractility.

Non-NASA Center↗

BDNF heightens the sensitivity of motor neurons to excitotoxic insults through activation of TrkB

The survival promoting and neuroprotective actions of brain-derived neurotrophic factor (BDNF) are well known but under certain circumstances this growth factor can also exacerbate excitotoxic insults to neurons. Prior exploration of the receptor through which BDNF exerts this action on motor neurons deflects attention away from p75. Here we investigated the possibility that BDNF acts through the receptor tyrosine kinase, TrkB, to confer on motor neurons sensitivity to excitotoxic challenge. We blocked BDNF activation of TrkB using a dominant negative TrkB mutant or a TrkB function blocking antibody, and found that this protected motor neurons against excitotoxic insult in cultures of mixed spinal cord neurons. Addition of a function blocking antibody to BDNF to mixed spinal cord neuron cultures is also neuroprotective indicating that endogenously produced BDNF participates in vulnerability to excitotoxicity. We next examined the intracellular signaling cascades that are engaged upon TrkB activation. Previously we found that inhibition of the phosphatidylinositide-3'-kinase (PI3'K) pathway blocks BDNF-induced excitotoxic sensitivity. Here we show that expression of a constitutively active catalytic subunit of PI3'K, p110, confers excitotoxic sensitivity (ES) upon motor neurons not incubated with BDNF. Parallel studies with purified motor neurons confirm that these events are likely to be occuring specifically within motor neurons. The abrogation of BDNF's capacity to accentuate excitotoxic insults may make it a more attractive neuroprotective agent.

Non-NASA Center↗

HURP regulates Kif18A recruitment and activity to synergistically control microtubule dynamics

Abstract During mitosis, microtubule dynamics are regulated to ensure proper alignment and segregation of chromosomes. The dynamics of kinetochore-attached microtubules are regulated by hepatoma-upregulated protein (HURP) and the mitotic kinesin-8 Kif18A, but the underlying mechanism remains elusive. Using single-molecule imaging in vitro, we demonstrate that Kif18A motility is regulated by HURP. While sparse decoration of HURP activates the motor, higher concentrations hinder processive motility. To shed light on this behavior, we determine the binding mode of HURP to microtubules using cryo-EM. The structure helps rationalize why HURP functions as a microtubule stabilizer. Additionally, HURP partially overlaps with the microtubule-binding site of the Kif18A motor domain, indicating that excess HURP inhibits Kif18A motility by steric exclusion. We also observe that HURP and Kif18A function together to suppress dynamics of the microtubule plus-end, providing a mechanistic basis for how they collectively serve in microtubule length control.

Science & Technology - Other Topics↗

Electromechanical flight control actuator, volume 1

An electromechanical actuator was developed that will follow a proportional control command with minimum wasted energy to demonstrate the feasibility of meeting space vehicle actuator requirements using advanced electromechanical concepts. The approach was restricted to a four-channel redundant configuration. Each channel has independent drive and control electronics, a brushless electric motor with brake, and velocity and position feedback transducers. A differential gearbox sums the output velocities of the motors. Normally, two motors are active and the other two are braked.

Source record↗

Examples of realistic aerosol particles collected in a cascade impactor

In this paper some scanning electron microscope photomicrographs showing examples of a variety of particulate aerosol shapes are presented. Compositions of particles also are presented. These particles represent samples from a number of different sources and locations including: solid propellant rocket motor plumes, active volcano plumes, the lower stratosphere over Sondrestrom, Greenland, and the upper troposphere over northern Texas. The particles were collected from aboard an aircraft with a cascade impactor which classified them according to aerodynamic size into 10 size intervals ranging from submicron to greater than 25 micrometers in diameter. The cascade impactor also served to measure the mass concentration as a function of particle size. The variety of shapes and compositions found among these particles suggest difficulties in obtaining reliable size distribution data from light scattering measurements.

Woods, D. C.↗

Physiological changes in fast and slow muscle with simulated weightlessness

A rat hindlimb suspension model of simulated weightlessness was used to examine the physiological characteristics of skeletal muscle. The physiological sequelae of hindlimb suspension were compared to those of spinal cord section, denervation by sciatic nerve crush, and control. Muscle examined were the predominantly slow (Type 1) soleus (SOL) and the predominantly fast (Type 2) extensor digitorum longus (EDL). Two procedures which alter motor unit activity, hindlimb suspension and spinal cord section, produce changes in characteristics of skeletal muscles that are dependent upon fiber type. The SOL develops characteristics more representative of a fast muscle, including smaller Type 1 fiber proportion and higher AChE activity. The EDL, which is already predominantly fast, loses most of its few Type 1 fibers, thus also becoming faster. These data are in agreement with the studies in which rats experienced actual weightlessness.

Dettbarn, W. D.↗

Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults With Amputations

The first single function myoelectric prosthetic hand was introduced in the 1960's. This hand was controlled by the electric fields generated by muscle contractions in the residual limb of the amputee user. Electrodes and amplifiers, embedded in the prosthetic socket, measured these electric fields across the skin, which increase in amplitude as the individual contracts their muscle. When the myoelectric signal reached a certain threshold amplitude, the control unit activated a motor which opened or closed a hand-like prosthetic terminal device with a pincher grip. Late in the 1990's, little has changed. Most current myoelectric prostheses still operate in this same, single-function way. To better understand the limitations of the current single-function myoelectric hand and the needs of those who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (NUH), surveyed approximately 2,500 individuals with upper limb loss [1]. When asked to identify specific features of their current myoelectric prostheses that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement, as well as poor control capability. However, simply building a mechanism with individual finger and wrist motion is not enough. In the 1960's and 1970's, engineers built a number of more dexterous prosthetic hands. Unfortunately, these were rejected during clinical trials due to a difficult and distracting control interface. The goal of this project, "Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults with Amputations," was to lay the foundation for a multi-function, intuitive myoelectric control system which requires no conscious thought to move the hand. We built an extensive myoelectric signal database for six motions from ten amputee volunteers, We also tested a control system based on new artificial intelligence techniques on the data from two of these subjects. This data is available to anyone doing myoelectric control research. Its availability is an important contribution to the prosthetics research community, as many researchers do not have access to amputee subjects. Since we collected myoelectric data from subjects' sound arms as well as their residual arms, this database will also prove useful to virtual reality and robotics researchers who want to explore myoelectric-based interfaces between any user and a machine. Currently, one small company (Intelligenta, Inc.) and one university (University of New Brunswick, Canada) are using this myoelectric database under other funding to develop multifunction control systems for prostheses. A prosthetics manufacturer (Liberty Technology, Inc.) is making plans to incorporate the results of their work into an artificial hand capable of several different movements to provide functionality only dreamed of by current myoelectric users. Methods Six adults and four children, all with unilateral, below-elbow amputations served as subjects. Five of the adults (3 male, 2 female, average age 34 years) had amputations due to traumatic injury, while one adult (female, age 32 years) and the four children (3 male, 1 female, average age 13 years) had congenital (i.e. from birth) limb deficiencies.

Atkins, Diane J.↗

NASA Participation in the ISAS MUSES C Asteroid Sample Return Mission

NASA and Japan's Institute of Space and Astronautical Science (ISAS) have agreed to cooperate on the first mission to collect samples from the surface of an asteroid and return them to Earth for in-depth study. The MUSES-C mission will be launched on a Japanese MV launch vehicle in January 2002 from Kagoshima Space Center, Japan, toward a touchdown on the asteroid Nereus in September 2003. A NASA-provided miniature rover will conduct in-situ measurements on the surface. The asteroid samples will be returned to Earth by MUSES-C via a parachute-borne recovery capsule in January 2006. NASA and ISAS will cooperate on several aspects of the mission, including mission support and scientific analysis. In addition to providing the rover, NASA will arrange for the testing of the MUSES-C re-entry heat shield at NASA/Ames Research Center, provide supplemental Deep Space Network tracking of the spacecraft, assist in navigating the spacecraft and provide arrangements for the recovery of the sample capsule at a landing site in the U. S. Scientific coinvestigators from the U.S. and Japan will share data from the instruments on the rover and the spacecraft. They will also collaborate on the investigations of the returned samples. With a mass of about I kg, the rover experiment will be a direct descendant of the technology used to build the Sojourner rover. The rover will carry three science instruments: a visible imaging camera, a near-infrared point spectrometer and an alpha X ray spectrometer. The solarpowered rover will move around the surface of Nereus collecting imagery data which are complimentary to the spacecraft investigation. The imaging system will be capable of making surface texture, composition, and morphology measurements at resolutions better than 1 cm. The rover will transmit this data to the spacecraft for relay back to Earth. Due to the microgravity environment on Nereus, the rover has been designed to right itself in case it flips over. Solar panels on all sides of the rover will ensure that enough power will always be available to the rover to activate the motors needed to turn over. Posable struts will allow the rover to position its chassis such that the camera can be pointed straight down at the surface or straight up at the sky. The presentation will describe the mission, scientific objectives and current state of the rover in detail.

Jones, Ross↗

Nanorovers and Subsurface Explorers for Mars

Recent advances in microtechnology and mobile robotics have made it feasible to create extremely small automated or remote-controlled vehicles which open new application frontiers. One of these possible applications is the use of nanorovers (robotic vehicles with a mass of order one kilogram or less) in planetary exploration. NASA and Japan's Institute of Space and Astronautical Science (ISAS) are cooperating on the first mission to collect samples from the surface of an asteroid and return them to Earth for in-depth study. The ISAS MUSES-C mission will be launched on a Japanese launch vehicle in July 2002 from Japan toward a rendez-vous with the asteroid 1989ML in September 2003. A NASA-provided nanorover will conduct in-situ measurements on the surface. With a mass of about one kilogram, the rover experiment will be a direct descendant of the technology used to build the Sojourner rover. The rover will carry three science instruments: (1) a visible imaging camera, (2) a near-infrared point spectrometer, and (3) an alpha X ray spectrometer. The solar-powered rover will move around the surface of 1989ML collecting imagery data, which are complimentary to the spacecraft investigation. The imaging system will be capable of making surface texture, composition, and morphology measurements at resolutions better than one millimeter. The rover will transmit this data to the spacecraft for relay back to Earth. Due to the microgravity environment on 1989ML, the rover has been designed to right itself in case it flips over. Solar panels on four sides of the rover will ensure that enough power will always be available to the rover to activate the motors needed to turn over. Posable struts will allow the rover to position its chassis such that the camera can be pointed straight down at the surface or straight up at the sky.

Wilcox, Brian H.↗

Devescovinid trichomonad with axostyle-based rotary motor ("Rubberneckia"): taxonomic assignment as Caduceia versatilis sp. nov

An amitochondriate trichomonad cell of the family Devescovinidae (Class Parabasalia), helped demonstrate the fluid model of lipoprotein cell membranes. This wood-ingesting symbiont in the hindgut of the dry wood-eating termite Cryptotermes cavifrons is informally known to cell biologists as "Rubberneckia". As the microtubular axo-style complex generates force causing clockwise movement of the entire anterior portion of the cell at the shear zone the protist displays "head" rotation. Studies by phase contrast and videomicroscopy of live cells, of whole mounts by scanning, and thin sections by transmission electron microscopy extend the observations of Tamm and Tamm [24-26] and Tamm [19-23]. Habitat, cell shape, size, nuclear features, parabasal apparatus and other morphological details permit the assignment of "Rubberneckia" to Kirby's cosmopolitan genus Caduceia. This large-sized devescovinid has distinctive parabasal gyres, an axostylar rotary, motor, and regularly-associated nonflagellated, fusiform and flagellated rod epibiotic surface bacteria. In addition to regularly aligned epibionts intranuclear and endocytoplasmic bacteria are abundant and hydrogenosomes are Present. "Rubberneckia" is compared here to the other seven species of Caduceia. Since it is clearly sufficiently distinctive to warrant new species status, we named it C. versatilis.

Non-NASA Center↗

Acronema sippewissettensis Gen. Nov. Sp. Nov., microbial mat bicosoecid (Bicosoecales = Bicosoecida)

A heterotrophic mastigote from the flat laminated Microcoleus-dominated intertidal microbial mat at the Sippewissett salt marsh, Cape Cod, Massachusetts, was isolated into monoprotist culture in the same anoxic medium that led to spirochete and other anaerobic bacterial enrichments. The protist grew vigorously and was transferred indefinitely in oxic marine medium. Videomicroscopy as well as scanning and transmission electron microscopy were used to document its features. The swimming and perching behavior, nutritional mode (bactivory) and morphology including ultra-structure identify it as an aloricate bicosoecid. The presence of heteromorphic acronematic undulipodia, bilateral bipartite tubular mastigonemes, absence of a cytostome, absence of extrusomes, and presence of "Dauerstadien" (duration stages) distinguish this from other Cafeteriaceae bicosoecids. Cell division involves a closed intranuclear spindle. The unspecialized bicosoecid morphology and behavior juxtaposed with oomycete-like vesicles and mastigonemes suggest that this protist may be an extant descendant of a common ancestor of bicosoecids and other stramenopiles (e.g. labyrinthulids, thraustochytrids and oomycetes). A new genus and species, Acronema sippewissettensis, are proposed.

Non-NASA Center↗

Association of particulate air pollution and acute mortality: involvement of ultrafine particles?

Recent epidemiological studies show an association between particulate air pollution and acute mortality and morbidity down to ambient particle concentrations below 100 micrograms/m3. Whether this association also implies a causality between acute health effects and particle exposure at these low levels is unclear at this time; no mechanism is known that would explain such dramatic effects of low ambient particle concentrations. Based on results of our past and most recent inhalation studies with ultrafine particles in rats, we propose that such particles, that is, particles below approximately 50 nm in diameter, may contribute to the observed increased mortality and morbidity In the past we demonstrated that inhalation of highly insoluble particles of low intrinsic toxicity, such as TiO2, results in significantly increased pulmonary inflammatory responses when their size is in the ultrafine particle range, approximately 20 nm in diameter. However, these effects were not of an acute nature and occurred only after prolonged inhalation exposure of the aggregated ultrafine particles at concentrations in the milligrams per cubic meter range. In contrast, in the course of our most recent studies with thermodegradation products of polytetrafluoroethylene (PTFE) we found that freshly generated PTFE fumes containing singlet ultrafine particles (median diameter 26 nm) were highly toxic to rats at inhaled concentrations of 0.7-1.0 x 10(6) particles/cm3, resulting in acute hemorrhagic pulmonary inflammation and death after 10-30 min of exposure. We also found that work performance of the rats in a running wheel was severely affected by PTFE fume exposure. These results confirm reports from other laboratories of the highly toxic nature of PTFE fumes, which cannot be attributed to gas-phase components of these fumes such as HF, carbonylfluoride, or perfluoroisobutylene, or to reactive radicals. The calculated mass concentration of the inhaled ultrafine PTFE particles in our studies was less than 60 micrograms/m3, a very low value to cause mortality in healthy rats. Aging of the fumes with concomitant aggregation of the ultrafine particles significantly decreases their toxicity. Since ultrafine particles are always present in the urban atmosphere, we suggest that they play a role in causing acute lung injury in sensitive parts of the population.

NASA Discipline Environmental Health↗

Altered vestibular function in fetal and newborn rats gestated in space

Researchers evaluated vestibular development and function in rat pups flown during gestation on the NASA-NIH R1 and R2 missions. Fetal and postnatal vestibular function were examined. Altered vestibular-mediated responses in the experimental fetal pups are attributed to either direct effect of gravity on the vestibular system or indirect effects of microgravity transduced through the mother. The postnatal tests confirmed the hypothesis that the vestibular system continually adapts and responds to tonic stimulation.

Non-NASA Center↗

Rat pregnancy and parturition survive spaceflight challenge: new considerations of developmental consequences

Results of the NASA-NIH.R1 and NASA-NIH.R2 pregnant rat studies are reported and compared with results of Cosmos-1514 study. Similarities and differences between the Cosmos and STS flights are reviewed. STS rats were videotaped so that in-flight and post-flight behavior could be observed. Rats were observed during readaptation to 1-g and labor and delivery. Results indicate that pregnancy can proceed after exposure to microgravity and that vaginal delivery can occur despite readaptation to 1-g. Analysis of videotape revealed that flight dams experienced almost twice as many labor contractions as controls.

short duration↗

Effects of microgravity on circadian rhythms in insects

The desert beetle Trigonoscelis gigas Reitt. was used as a biological model in studies that examined the effects of space flight on the circadian timing system. Results from studies aboard the Bion-10, Bion-11, and Photon-11 missions are reported. The control study is an ongoing Mir experiment. The studies indicate that the free-running period in beetles may be longer during space flight.

NASA Experiment Number 9401698↗

Integration of vestibular and head movement signals in the vestibular nuclei during whole-body rotation

Single-unit recordings were obtained from 107 horizontal semicircular canal-related central vestibular neurons in three alert squirrel monkeys during passive sinusoidal whole-body rotation (WBR) while the head was free to move in the yaw plane (2.3 Hz, 20 degrees /s). Most of the units were identified as secondary vestibular neurons by electrical stimulation of the ipsilateral vestibular nerve (61/80 tested). Both non-eye-movement (n = 52) and eye-movement-related (n = 55) units were studied. Unit responses recorded when the head was free to move were compared with responses recorded when the head was restrained from moving. WBR in the absence of a visual target evoked a compensatory vestibulocollic reflex (VCR) that effectively reduced the head velocity in space by an average of 33 +/- 14%. In 73 units, the compensatory head movements were sufficiently large to permit the effect of the VCR on vestibular signal processing to be assessed quantitatively. The VCR affected the rotational responses of different vestibular neurons in different ways. Approximately one-half of the units (34/73, 47%) had responses that decreased as head velocity decreased. However, the responses of many other units (24/73) showed little change. These cells had signals that were better correlated with trunk velocity than with head velocity. The remaining units had responses that were significantly larger (15/73, 21%) when the VCR produced a decrease in head velocity. Eye-movement-related units tended to have rotational responses that were correlated with head velocity. On the other hand, non-eye-movement units tended to have rotational responses that were better correlated with trunk velocity. We conclude that sensory vestibular signals are transformed from head-in-space coordinates to trunk-in-space coordinates on many secondary vestibular neurons in the vestibular nuclei by the addition of inputs related to head rotation on the trunk. This coordinate transformation is presumably important for controlling postural reflexes and constructing a central percept of body orientation and movement in space.

Non-NASA Center↗

Concept Developed for an Implanted Stimulated Muscle-Powered Piezoelectric Generator

Implanted electronic devices are typically powered by batteries or transcutaneous power transmission. Batteries must be replaced or recharged, and transcutaneous power sources burden the patient or subject with external equipment prone to failure. A completely self-sustaining implanted power source would alleviate these limitations. Skeletal muscle provides an available autologous power source containing native chemical energy that produces power in excess of the requirements for muscle activation by motor nerve stimulation. A concept has been developed to convert stimulated skeletal muscle power into electrical energy (see the preceding illustration). We propose to connect a piezoelectric generator between a muscle tendon and bone. Electrically stimulated muscle contractions would exert force on the piezoelectric generator, charging a storage circuit that would be used to power the stimulator and other devices.

Lewandowski, Beth↗